| 1 | L2₹1.8 L+₹460 (0.26%)Qualified Make: NA
Model: SFCA4 16 1ST FLOOR CHUNAWALA BUILDING NEAR AL SADIQ HOSPITAL MOHAMMAD ALI ROAD MANDVI MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Make: NA
Model: SFCA4 | L2 | Qualified | |
| 2 | Qualified Make: Foamtech Brand
Model: Current Model 153 K L SECTOR 53 EPIP KUNDLI SONEPAT SONIPAT HARYANA 131028 | SONIPAT | HARYANA | 131028 | Make: Foamtech Brand
Model: Current Model | - | Qualified | |
| 3 | L1₹1.8 LDisqualified Make: FIRECHEM
Model: FC-144 153 K L SECTOR 53 EPIP KUNDLI SONEPAT SONIPAT HARYANA 131028 | SONIPAT | HARYANA | 131028 | Make: FIRECHEM
Model: FC-144 | L1 | Disqualified | |
| 4 | Disqualified Make: intime
Model: INTIME CLEAN AGENT 4 KG 00 BEHIND ISHA HOSPITA CHITRAGUPT COLONY UMARPUR HARIBANDAHANPUR JAUNPUR UTTAR PRADESH 222002 | JAUNPUR | UTTAR PRADESH | 222002 | Make: intime
Model: INTIME CLEAN AGENT 4 KG | - | Disqualified | |
| 5 | Disqualified Make: SWIFGO FIRE
Model: SWIFGO FIRE IS BASED STORED PRESSURE PORTABLE FIRE EXTINGUISHER 4CA 52 2ND FLOOR AMARWADI NATH MADHAV PATH C P TANK MUMBAI MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | Make: SWIFGO FIRE
Model: SWIFGO FIRE IS BASED STORED PRESSURE PORTABLE FIRE EXTINGUISHER 4CA | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
20 Jul 2018, 10:00 amClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Clean Agent Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media HFC - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire Extinguisher Capacity (Kg) 4 1
2
NA Carbon Dioxide Based Fire Extinguisher NA 2
3
4.5
NA 1/4 Capacity (Kg) Water Based Fire Extinguisher Capacity NA 2
NA Clean Agents Fire Extinguisher Capacity (Kg) 4 4 Weight of Filled Portable Fire Extinghuisher (Kg) 17 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -20° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar
Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 18 Fire Rating for Class -A Fire Extinguisher 2A - Fire Rating for Class -B Fire Extinguisher 21B - 2/4 Certification BIS Marking Yes - CM/L No.* with Validity Period - - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Siddhartha Raha 500078
CISFFSTI hyderabad 20 15
334478
GEM/2018/B/47415
Portable Fire Extinguishers IS 15683
15 days
Telangana; Medchal Malkajgiri
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Clean Agent Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media HFC - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire Extinguisher Capacity (Kg) 4 1 | - | - | - |
| 2 | - | - | - |
| NA Carbon Dioxide Based Fire Extinguisher NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA 1/4 Capacity (Kg) Water Based Fire Extinguisher Capacity NA 2 | - | - | - |
| NA Clean Agents Fire Extinguisher Capacity (Kg) 4 4 Weight of Filled Portable Fire Extinghuisher (Kg) 17 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -20° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar | - | - | - |
| Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 18 Fire Rating for Class -A Fire Extinguisher 2A - Fire Rating for Class -B Fire Extinguisher 21B - 2/4 Certification BIS Marking Yes - CM/L No.* with Validity Period - - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Siddhartha Raha 500078 | - | - | - |
| CISFFSTI hyderabad 20 15 | - | - | - |
Exempted
20 Jul 2018
15 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_334478.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .