Loading…
Loading…
Tender ID
Tender Value
₹17.7 Cr
EMD Value
₹17.7 L
Closing Date
4 Feb 2026, 6:00 pmClosed
DY.CITY ENGINEER (SOUTH ZONE)
Proposed Construction of Swimming Pool at T.P.-128, F.P.-493 in Vatva Ward, South Zone, Ahmedabad
263440
Tender notice no 16/2025-26
Open
Civil Works - Others
Works
Ahmedabad
5 documents required · 5 mandatory
₹18,000
Yes
municipal commissioner
₹17.7 L
Yes
9 Jan 2026
9 Jan 2026
9 Jan 2026
4 Feb 2026
9 Jan 2026
Estimated cost put to tender : Rs. 17,68,87,111.46 Estimated cost put to tender : Rs.
Add_____% Above : Rs ___________ Add_____% Below : Rs ___________
Total : Rs___________ Total : Rs___________
In words : Rupees _______________________ In words : Rupees _______________________
The contractor should get the sample of material in respect of quality and source of supply or manufacturer approved by
Consultant / AMC in all cases. All such approved samples should be kept at site in the custody of EIC-CMC/PMC/AMC.
Note-1 The tests for the make in external laboratory in presence of CMC/PMC/AMC to be carried out by Contractor at his own
cost as per relevant latest codes. Reinforcement steel & cement original purchase bills shall be produced to
CMC/PMC/AMC as and when asked for.
Note-2 Rate includes for any height, any level, any lead & lift and as per directed by EIC.
Note-3 For Fire Fighting System Autoglow Mandatory Sinages and NOC Process and charges of NOC are included.
Signature of Contractor Additional City Engineer
Seal South Zone
Date Ahmedabad Municipal Corporation
Ahmedabad Municipal Corporation
Proposed Construction of Swimming Pool at T.P.-128, F.P.-493 in Vatva Ward, South Zone, Ahmedabad.
BOQ of Civil, Site Development & Plumbing Work
Item Description Unit Rate Amount
(A) Excavation & Earthwork
Clearing and grubbing road land including uprooting rank vegetation grass bushes,shrubs,sapling and trees girth up to 300 mm removal
1 of stumps of trees cut earlier and disposal of unserviceable materials Sqm 7,889.00 2.81
(C) By mechanical means in area of light jungle
Excavation for foundation for depth upto 1.5 m including sorting out and stacking of useful materials and disposing off the excavated
2 stuff upto 50 Meter lead. Cum 11,823.00 148.19
(A) Dense or Hard Soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the
3 excavated stuff upto 50 Meter lead. Cum 9,554.00 160.77
(B) Dense or Hard Soil
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the
4 excavated stuff upto 50 Meter lead. Cum 6,091.00 172.50
(C) Dense or Hard Soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth
consolidating each disposited layer by ramming and watering.
6 Filling in plinth with sand under floors including watering, ramming, consolidating and dressing etc. completed Cum 360.00 455.63
Filling in plinth with murrum or selected soil in layers of 20 cm. thickness including watering, ramming and consolidating etc.
Complete. (brought from out side)
Providing and laying rubble soling, 230 mm thick, in a compact manner,foudation, road, footpath etc. using 200 to 230 mm. cut size
8 stones including filling the gaps with 40mm metal and packing with stone chips with murrum covering and levelling the surface after Cum 1,964.00 2,035.00
filling the voids including watering, ramming well and consolidating each layer, as directed by EIC.
Conveyance charges of lime murrum building rubbish earth, manuar of sludge and excavated rock,fly ash & surplus excavated earth
9 from site as directed by etc. complete as directed by EIC. Cum 2,468.00 320.73
A) Upto 5.00 Km.
(B) PCC & RCC Work
Provdg. & laying cement concrete 1:2:4 (1cement:2 corse sand :4 broken stone aggregate 20 mm nominal size) and curing complete
11 including cost of form work in Cum 1,688.00 3,661.30
(A) Foundation and plinth
Providing, laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding reinforcement
for reinforced concrete work in: Up to Plinth Level. (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
Item Description Unit Rate Amount
Providing, laying controlled cement concrete M 300 and curing complete including the costExcavation
of form work&but excluding reinforcement
for reinforced concrete work in: Up to Plinth Level. (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
Providing, laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding reinforcement
14 for reinforced concrete work in: Column (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be paid) Cum 283.00 7,373.00
(1) Column up to Ground Floor slab
Providing, laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding reinforcement
15 for reinforced concrete work in: Column (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be paid) Cum 41.00 7,413.00
2) Column First Floor
Providing, laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding reinforcement
16 for reinforced concrete work in: Column (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be paid) Cum 13.00 7,453.00
3) Column Second Floor
Providing, laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding reinforcement
for reinforced concrete work in: Up to Plinth Level. (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
(A) Plinth beam
Providing and laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in: Beam (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
1) Floor beam Ground Floor
Providing and laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in: Beam (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
2) Floor beam First Floor
Providing and laying controlled cement concrete M 250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in: Beam (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
3) Floor beam Second Floor
Providing, laying controlled cement concrete M 300 and curing complete including the cost of form work but excluding reinforcement
21 for reinforced concrete work in:RCC wall (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be paid) Cum 229.00 7,344.00
1) RCC wall up to Ground floor slab
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in: Grade Slab
Item Description Unit Rate Amount
Providing and laying controlled cement concrete M-250 and curing complete including Excavation
the cost of&form
work but excluding
23 reinforcement for reinforced concrete work in:Slab (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be paid) Cum 169.00 6,177.00
1) R.C.C. slab Ground Floor
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
24 reinforcement for reinforced concrete work in:Slab (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be paid) Cum 15.00 6,216.00
2) R.C.C. slab First Floor
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in: Staircase (Design Mix or RMC can be use as directed by EIC/PMC. No Extra Rate can
1) Staircase Ground Floor
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in: Staircase (Design Mix or RMC can be use as directed by EIC/PMC. No Extra Rate can
2) Staircase First Floor
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in : Lintel (Design Mix or RMC can be use as directed by EIC/PMC. No Extra Rate can be
1) Lintel Ground Floor
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work in : Lintel (Design Mix or RMC can be use as directed by EIC/PMC. No Extra Rate can be
2) Lintel First Floor
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work: Chhajja (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
1) Chhajja Ground Floor
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding
reinforcement for reinforced concrete work: Chhajja (Design Mix or RMC can be use as directed by EIC/PMC.No Extra Rate can be
2) Chhajja First Floor
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per
approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to
Kms. having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work
including pumping of R.M.C. from transit mixer to site of laying in levels and pattern of bays as detail of architect and finished with
screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc., finishing and
31 reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve Cum 454.00 7,440.00
workability without impairing strength and durability as per direction of the Engineer in - charge. Without Fly Ash (Min cement level as
per latest IS 456 shall be maintained). The rate shall include cost of side shuttering with channels, rails, to form panels and groove
cutting etc. including filling the joint with glass strip/polysulphite complete to use. The rate shall also include the cost of reinforcement
approximate calculated at 5.14 kg/Smt. Rate for all lead & lift & as per directed by Engineer in - charge.
(Note: - Cement content considered in this item is @ 450 kg/cum.)
Item Description Unit Rate Amount
Providing and laying TMT Bar FE 500D reinforcement for R.C.C. work and bending, binding & placing in&position
Excavation completed upto any
floor any level as per I.S. Standard. complete.as directed by EIC.
(C) Masonry Work
Providing and laying Brick work using common burnt clay building bricks having crushing strength not less than 35 kg/Sq. cm. In
33 foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand) (B) Conventional. Up to Cum 90.00 3,981.21
1) Plinth level.
Providing and laying Brick work using common burnt clay building bricks having crushing strength not less than 35 kg/Sq. cm. In
34 Superstructure in cement mortar 1:6 (1 cement : 6 fine sand) (B) Conventional. Cum 668.00 4,253.46
2) Ground Floor.
Providing and laying Brick work using common burnt clay building bricks having crushing strength not less than 35 kg/Sq. cm. In
35 Superstructure in cement mortar 1:6 (1 cement : 6 fine sand) (B) Conventional. Cum 154.00 4,293.25
3) First Floor.
Providing and laying Brick work using common burnt clay building bricks having crushing strength not less than 35 kg/Sq. cm. In
36 Superstructure in cement mortar 1:6 (1 cement : 6 fine sand) (B) Conventional. Cum 10.00 4,333.04
4) Second Floor.
Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-
Cement : 4 -coarse sand ) in
(B) Conventional
(1) Ground floor
Providing & Fixing the Chikenmesh - 20 guage (Crimp Jali) of approved size applying between the RCC and masonry junction in proper
38 line, level and plumb with all material, labour, tools, tackles and equipment. Including providing and fixing the jali with nails, etc Sqm 1,949.00 285.00
complete as directed by the site-in-charge
(D) Plaster & Paint Work
Providing and laying 20 mm thick water proof cement plaster using water proofing powder 1 Kg / 1 bag of cement for all floors on brick
39 / concrete wall work using water proofing materials in C M 1: 4 (1 cement : 4 coasrse sand) including finishing with a flooting coat of Sqm 4,452.00 249.00
neat cement slurry etc complete for all floor.
Providing 15 mm. thick cement plaster in single coat on fair side of brick wall for interior plastering upto floor two level finished even
40 and smooth in [II] Cement mortar 1:4 (1 cement : 4 fine sand) For all levels, hights and leads of works. etc. complete as directed by EIC. Sqm 4,969.00 155.61
1) Ground Floor
Providing 15 mm. thick cement plaster in single coat on fair side of brick wall for interior plastering upto floor two level finished even
41 and smooth in [II] Cement mortar 1:4 (1 cement : 4 fine sand) For all levels, hights and leads of works. etc. complete as directed by EIC. Sqm 566.00 180.18
Providing 15 mm. thick cement plaster in single coat on fair side of brick wall for interior plastering upto floor two level finished even
42 and smooth in [II] Cement mortar 1:4 (1 cement : 4 fine sand) For all levels, hights and leads of works. etc. complete as directed by EIC. Sqm 33.00 203.34
3) Second Floor
Providing & laying 10 mm. thick cement plaster in single coat on fair side of brick concrete walls & ceilings for interior plastering upto
43 floor two level and finishing with smooth mala plaster. (i) Cement mortar 1:4 (1 cement : 4 sand) Sqm 1,328.00 114.66
1) Ground Floor
Providing & laying 10 mm. thick cement plaster in single coat on fair side of brick concrete walls & ceilings for interior plastering upto
44 floor two level and finishing with smooth mala plaster. (i) Cement mortar 1:4 (1 cement : 4 sand) Sqm 100.00 139.23
Item Description Unit Rate Amount
Excavation & Earthwork
Providing & laying 20 mm. thick Mala cement plaster on walls up to any height any lead and above ground level consisting of 12 mm.
thick backing coating of C.M. 1:3 (1 cement : 3 sand) and 8 mm. thick finishing coat in C.M. 1:1 (1 cement :1 sand) etc. complete.
Providing and applying 2mm thick Texture Plaster of Earthen Textures, Travertino Texture, Coral texture or equivalent make
incorporating fine filaments made of polymer and aggregating natural stone powder with making grooves on existing base coat of 20 mm
thick smooth mala plaster etc. Complete with two coat Exterior weather proof paint and one coat of primer in any shade As per drawings
and design supplied by architect and instruction given by authority and E.I.C. for all floor all height.
Providing 8 mm Luxture decorcem expose concerte or brick concerte coating and wall textured paint using base coat, tapping, durabond
47 expose RCC materials and finishing with decorsil two coat etc. complete. As per drawings and design supplied by architect and Sqm 439.00 1,582.48
instruction given by authority and E.I.C. for all floor all height.
Applying two coats of Birla or Asian acrylic lappy (putty) and two coats of primer of approved brand and manufacture on new wall
surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand
48 prepared smooth. (Putty shall have low-VOC (Volatile Organic Compound) and Wall painting (two coats) with plastic emulsion paint of Sqm 6,997.00 118.63
approved brand and manufacture on wall surfaces to give an even shade including thoroughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
Wall Painting (two coats) with weather proof extirior emulsion paint of approved brand and manufacture and of required shade on
49 exterior wall surface to give an even shade over and including a primery coat with alkaly resistance primer of approved brand after Sqm 4,388.00 113.40
thoughly brushing surface to remove all dirt and remains of loose powdered materials etc comp. for all height.
(E) Door & Window Work
Providing and fixing flush door both sides laminated and I.T.W. beading all around by using I.T.W. frame 120 m.m. x 80m.m.. shutter
fabricated from 35 mm thick solid core malemine faced three layered pre laminated flat pressed wood based exterior grade bonded
50 BWP/BWR synthetic resin having stamped IS 12823 grade I type II including three coats of lacquer polishing to exposed wooden Sqm 61.00 5,773.00
surfaces and Stainless steel decorative type designs fixtures / fastening 2Nos. Handles, 2Nos. Aldropes, towerbolt etc.including I.T.W.
triangular batten patti of size 30m.m.x30m.m.etc. as per architectural detailed drawing and as directed by engineer in charge..
Providing and fixing FRP FRAME size 100 x 50 mm & 28 mm thick FRP depress pannel shutter having extra reinfocement on sides and
edges in Gel coat finish. The core of the shutter & frame is to be filled up with injected fire retardant grade plyurethane foam done in situ
along with embedded wooden pices for stiffening & also for taking hinges and fixtures. The whole FRP frame and shutter is to be water
proof, weather proof, termite proof and resistance to mild acid/alkalis Rates are to be inclusive of S.S. hinges with necessary screws and
stainless steel fixtures and fastening with fastener & sleeve. Product should have 3 years perfomance guarantee & company have 9001-
2000 certificate. (For Toilet Purpose)
Providing and fixing All door partly glazed & partly pannelled door of approved colour Andised and standard extruded alluminium
frame 101.60 x 44.45 x 1.60mm @ 1.301 kg. with provided single door shutters having bottom rail 114.30 x 44.45 x 1.35 @ 1.19 Kg/
Rmt. Lock, Top & style 83.50 x 44.45 x 1.80 @ 1.50 kg ,Vartical rail 85.00 x 44.45 x 1.80 @ 1.301 Kg/Rmt and glazing clips 19.00 x
17.30 x 0.90 @ 0.124 Kg/Rmt with 5mm thick float glass,silicon gasket and 6mm Pre-lamineted board at bottom as per drawings 1-nos
of pivot/ Hinges 4 nos 125mm, D type 200, Alluminium handle 2 nos, lock of Apprvoed Quality 1 nos, Towarbolt 150mm 1 Nos, Floor
door stopper 1 Nos, including fixtures & Fastening etc. Complete.
Item Description Unit Rate Amount
Providing & fixing in position standard extruded Aluminium Partition with Colour anodizedExcavation
&frame of approved shade &
pivoted without shutter fabricated from alluminium standard section for outer frame size 101.60 x 44.45 x 1.60mm @ 1.301 kg. and
53 using Glasing Clips 19.00 x 17.30 x 0.90 @ 0.124 Kg/Rmt and providing rubber gasket around the glass allover including providing 6 Sqm 46.00 3,063.00
mm th. transparent float glass of copper/ gray tint (Structural Glass) fixed with transparent silicon gasket and in bottom panel 6mm thick
compact sheet bothside including all required materials labours and equipments as per detailed drwg. as directed.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS :
54 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment Nos. 24.00 2,815.00
with necessary accessories and screws etc. complete.
Providing and fixing window having extruded aluminum Colour anodized section frame main outer size 63.50 x 38.10 x 1.95 mm,@ Wt
1.094 Kg / Rmt, horizontal two track member size 61.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical member of size
mm x 31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm @ wt.of
0.456Kg/mt, vertical member of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm thick transparent
bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as
per details etc complete for window.
Providing and fixing standared extruded of alluminium section of size 63mm x 38.10mm x 1.2mm @ Wt. 0.643 Kg/mt with colour
anodized alluminium frame for ventilation with 5 mm thick frosted glass as details etc complete for Ventilation
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length
and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and
arragements for inside and outside locking with push-pull operation including the cost of hood cover and spring etc. complete.
(A) Shutters having width below 3.5 M.
Proving and fixing 12mm thk fixed toughned glass with required SS fitting complete in all respect. Note :- (i) Rate to include all
necessary supports & U channel at bottom and as per details.
(F) Structural Steel Work
Providing and fixing M.S. grill of required pattern for windows etc. with M.S.. flats at required spacing and frame alround square or
59 round headed bolts and nuts or by screws.including applying a priming coat of red lead paint and two coats of oil painting etc complete Kg 1,164.00 107.00
(A) Plain grill
Providing, supplying, fabricating and erecting in position the structural steel for colums, grill, gates, bars, truss, purlins, runners, cleats,
insert plate, base plate etc for all structural elements as per detail, made up from closed structural steel hollow sections (RHS/SHS
including rolled section) or angle or chanel with weather resistant of Tata Structural / sections or an approved equivalent as per details /
60 drawings/instructions including cutting, bending, jointing, connecting, welding and / bolting and / riveting and fabricating and erecting Kg 1,553.00 86.00
in position etc complete for all levels as directed. The rate to include all necessary fixtures, fastening including welding rods of standard
approvded quality etc for complete the job. The rate shall also include the two coats of synthetic enamel paint with priming coat &
necessary scaffolding etc. complete as directed
(G) Flooring Work
Providing and laying Bare Foot flooring tiles over 20 mm. average thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and laid
over and jointed with grey cement slurry including rubbing and polishing complete. 18 mm Thick Bare Foot Tiles
Providing and laying Granite stone slab flooring over 20 mm. average thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and
laid over and jointed with grey cement slurry including rubbing and polishing complete. 18 mm Thick
Providing and laying polished granite stone slab 18 mm thick in risers of steps, dedo and pllars laid on 10 mm thick cement mortar 1:3 (1
cement : 3 coarse sand) and jointed with gray cement slurry including rubbing & polishing etc. complete.
Item Description Unit Rate Amount
Providing & fixing Granite for Door Jamb, Sill and the like similar location of 18mm thick,Excavation
from 1050 to & Earthwork
2105mm in length and width
150mm /250mm in cement mortar 1:2 [1 white cement : 2 marble dust] with an admixture of pigment to match the marble shade
64 including fixing with copper pin 7.5cm long of 6mm diameters in cement mortar 1:2 (1 cement : 2 fine sand) including making rebate for Sqm 85.00 3,254.00
door shutter in Granite, edege polishing and moulding etc. completed as directed by EIC / Consultant.(Clear measurement will be taken
on sqmt basis for both Jamb)
Providing and fixing Granite sand which type platform including supplying and fixing granite stone 18 mm thick mirror polished 1st
quality Granite stones in top and side posiition and vertical strip at front over 25 mm thick polished kotah stone platform fixing in top
and sides and itermediates supports fixing with cement mortar and adhesivee and finishing including providing & cutting of kitchen sink
(as directed) 600 mm x 450 mm x 200 mm size stainless steel sink (as directed by engineer incharge) at required position etc complete.
Providing and laying broken chine mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement
66 mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off Sqm 1,060.00 739.89
junctions and extending them upto 15 cm along the wall,clearing with water and oxalic acid etc. as directed.
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1cement : 6-coarse sand)
or L.M. 1.1.5 (1-Lime putty :1.5 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of
slab including rubbing and polishing etc. complete.
Providing and laying polished kota stone slab 25mm thick in risers of steps, skirting Dedo and pillars laid on 10mm thick cement mortar
68 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and Sqm 14.00 1,176.03
polishing etc. complete.
Providing and laying coloured glazed tiles of the size 300 mm x 450 mm x 8 mm in skirting, risers of steps and dedo on 10 mm. thick
cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with white cement slurry.
Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid in
one layer and finished with a floating coat of neat cement. (B) 50mm thick.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4
71 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments Sqm 361.00 1,104.73
etc., complete.
Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by
manufacturer), with water absorption less than 0.08 % and conforming to I.S 15622, of approved make, in all colours & shade, in
72 skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm 24.00 1,181.24
sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 (1 cement : 6 coarse sand) on new
73 surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement Sqm 303.00 1,383.99
slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit
Providing and laying IPS cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid
in one layer and finished with a floating coat of neat cement. (B) 50mm thick.
Providing and laying chemical coating masterseal 550 El (BASF or equivalent) in existing swimming pool area with clening surface with
brush or other material as instruction, approved by architect engineer in charge.
Item Description Unit Rate Amount
Excavation & Earthwork
244 x 119 x 9 mm FINA approved vitrified tile in white or sky blue colour and lane marking as per FINA in dark blue or black Sqm 1,870.00 1,950.00
Fixing Specialized Tiles: Tile size 244 x 119 mm x 9 mm thickness (6mm spacer between tiles) of Orient Blue / New Blue / Dark Blue
Shade complete as per suggested by Architect. Following is the Laying procedure of tile in Olympic Size Swimming Pool: 1) Laying of
77 tiles by keeping spacers between two tiles with L111 Crete Filler Powder + L73 Crete Admix. Company suggest L111+L73 for vitrified Sqm 1,870.00 2,400.00
body tile. 2) After laying of tiles, will do pre-grouting with white cement and then epoxy grouting with SP100 latapoxy. 3) After epoxy
grouting, will clean swimming pool with mild acid. So total thickness after plaster with tile will be 13mm.
78 244 x 119 FINA approved Hand Grip tile on the top wall between pool & overflow channel Nos. 633.00 750.00
79 244 x 119 FINA approved anti skid tile on the top wall between pool & overflow channel Nos. 633.00 750.00
Fixing hand grip and anti skid tiles: Tile size 244 x 119mm (6mm spacer between tiles) Following is the Laying procedure of tile : 1)
Laying of tiles by keeping spacers between two tiles with L111 Crete Filler Powder + L73 Crete Admix. Company suggest L111+L73
for vitrified body tile. 2) After laying of tiles, will do pre-grouting with white cement and then epoxy grouting with SP100 latapoxy. 3)
After epoxy grouting, will clean swimming pool with mild acid.
(H) Miscellaneous Work
81 Providing cement vata (10cm. x 10 cm. size) quarter round in cement mortar 1:1 including neat cement finishing, watering etc. complete. Rmt 216.00 23.45
82 Providing and laying throttling or plaster and molding to RCC Chhajja. Rmt 216.00 41.25
Carring out plinth treatment to post construction /existing structure by spraying chemical solution for termite control treatment including
labour and material consistment with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration
Weight one percent is recommended i.e one litre 20 EC chemical emulsion with 19 liter give 1 % concrentration inclusive of one litre
chemical emulsion appication at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S
Providing and fixing Structural Glazing with using the 17 Micron anodised of approved colour alluminium section as transium, mullium
of size 63.5mm x 38.1mm x 2 mm with using 5 mm thick reflective structural glass and fixed with silicone sealant and spacer tap and at
corner sealed neoprene foam dust and Air sealed gasket mirred including scaffolding etc.complete with all necessary fitting and fixtures
for openable window as per Architectural drawing and as directed by Engineer-in-charge.
Providing and laying rough kota stone machine cut size 2' x 2'with spacer flooring over 20 mm (average) base of cement mortar 1:5 (1
85 cement : 5 coarse sand) or L.M. 1.1.5 including pointing with cement mortar 1:2 (1 cement : 2 stone dust) etc.complete. Sqm 58.00 544.03
Making holes upto any RCC members by diamond Core Cutting machine of HILTI or equivalent including disposing the debries.
Item Description Unit Rate Amount
Excavation & Earthwork
Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on
the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible as
per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation . The
Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe having
NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot
dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at
joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’
of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to
form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to
be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter
wall angle pre-coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm
centre to centre with 25mm long dry
Pro. And fixing single layer water proof gypsum board 12.5 mm thick sections using water proof board of size 1220 mm x 1830 mm x
8.0 mm suspended by GI suspender channel of size 25 mm x 3 mm with intermediate channel og size 18 mm x 40 mm x 0.8 mm at
90 mm center to center ceiling section of size 40 mm x 35 mm x 0.55 mm at 457 mm c/c and perimeter channel A of size 20 mm x 27 mm x Sqm 953.00 600.94
30 mm x 0.5 mm at edges & drops incl.paper tap sand sofit cleat, anchor fastener, scoch bolt connecting cleat,joining compound top coat
on ceiling incl.making necy.opening for light fitting,diffuser etc. comp. as per detail drawing as directed
Drilling hole of required diameter and depth` as directed for fixing of rebars,using hammer drill, cleaning the hole using mechanical air
91 flower, water etc,providing and fixing rebar in the drilled hole using RE 500 V4 or Equivalent approved make Cementetious chemical Each 86.00 631.00
grout and sealant with necessary scaffolding, staging, labour, tools and equipment etc. complete as directed by Engineer-in-charge.
(A) 8 mm dia bar (160 mm depth)
92 (B) 10 mm dia bar (200 mm depth) Each 86.00 906.00
93 (C) 12 mm dia bar (240 mm depth) Each 86.00 1,261.00
94 (D) 16 mm dia bar (320 mm depth) Each 86.00 2,166.00
95 (E) 20mm dia bar (400 mm depth) Each 86.00 4,212.00
96 (F) 25mm dia bar (500 mm depth) Each 86.00 8,659.00
97 (G) 32mm dia bar (640 mm depth) Each 86.00 15,981.00
Fabricating, supplying and fixing in position SS railing for staircase and Swimming Pool etc,. with brush finish and 304 grade as per
98 Indian Standrd and detailed drawing including grinding, cleaning and filling the welded spots with SS finish (Only Length will be paid Rmt 38.00 2,425.00
for payment heigth max.1.0 mt.). The Work to be executed as per consultant drawing .
Fabricating, supplying and fixing in position SS daso for staircase and balcony with brush finish and 304 grade as per Indian Standrd
99 and detailed drawing including grinding, cleaning and filling the welded spots with SS finish (Only Length will be paid for payment ). Rmt 37.00 1,365.00
The Work to be executed as per consultant drawing .
Item Description Unit Rate Amount
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thickExcavation
with grade&ofEarthwork
concrete M300 pnumatic
compressed / vibrated mechanically and as per approved design Confirming to IS 15658 : 2006 including 35 mm Sand layer for levelling
and filling the joint with sand in proper line and level as per guidlines of IRC : SP 632018 etc. Complete.(Alcock,Vyara or equivalent
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 35cm length,30cm height and 15cm thick of
101 M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 Rmt 428.00 358.06
(1cement:3fine sand) etc complete.
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under
ground structures as directed by Engineer-in-Charge and consisting of :
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement :
3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course
(leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd
Using rough kota stone. (Horizontal)
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to
25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of
20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing
compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement
punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
Using rough Kota stone. (Vertical)
Providing, laying and fixing 200 mm wide PVC water stop of approved make and grade thickness in concrete work for water
104 tightstructures like retaining walls of pound water body and underground water tank including cleaning and placing in line level etc. Rmt 912.00 508.00
complete, as directed.
Supply of HDP (High Density PVC) Locker made out of 12mm & 18mm thick board, size 300w x 450ht x 400 dt mm with 18mm thick
106 Providing & Fixing AUTOGLOW Signages in Block / Small Letters of Specified Sizes Fire lift size: 4" X 12" Each 46.00 298.93
Providing and fixing cast iron steps of size 500 mm x 150 mm x 22.5 mm and painting with two coat, coats of anticorrosive paint etc.
108 Providing and Fixing C.I. Cover with Frame: 600mm X 850mm Each 9.00 3,840.18
109 Supplying and fixing, water level controller for the over head tanks of approved make complete, as directed Each 2.00 5,011.61
Item Description Unit Rate Amount
Excavation & Earthwork
Providing and fixing beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to
wooden cleats with C.P. brass screws and washers complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including
adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken
bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5
coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and
treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper
curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass
fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making
pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two
weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge
:With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (Terrace)
(Only plan area should be measured)
Constructing Under Ground water tank with Providing and laying controlled cement concrete M250 mix for R.C.C. work including
reinforcement, boxing, centering, vibrating, , PVC water stopper, curing and mixed with approved water proofing cement compound or
"CEMWET" or "PIDICRETE LW" integral water proofing admixture as water proofing agent to be mixed with 50 kgs. bags shall be as
recommended by the manufacture of the water proofing material, concrete work for top, bottom slab & side pardi for underground water
112 tank item incl. Necessary excavation & refilling the available earth, 15 cm thk 1:2:4 for bedding of concrete, 20 mm thk. water proofing Litre 82,500.00 15.00
cement plaster in C.M. 1:3 with smooth finishing & Glazes tile Dedo, vata, watering etc. Comp. to all face of tank . including locking
arrangement outlet, inlet, overflow and washout outlet pipe arrangement as necessary & C.I. Cover 0.60 x 0.45 weight not less then 35 kg
with locking arrangement. etc. comp as per structural drawing Including Reinforcement TMT-FE 500D as directed by Engineer in-
Constructing RCC Overhead water tank with Providing and laying controlled cement concrete M250 mix for R.C.C. work including
reinforcement, boxing, centering, vibrating, , PVC water stopper, curing and mixed with approved water proofing cement compound or
"CEMWET" or "PIDICRETE LW" integral water proofing admixture as water proofing agent to be mixed with 50 kgs. bags shall be as
recommended by the manufacture of the water proofing material, concrete work for top, bottom slab & side pardi for Overhead water
tank item incl. 20 mm thk. water proofing cement plaster in C.M. 1:3 with smooth finishing & Glazes tile Dedo, vata, watering etc.
Comp. to all face of tank . including locking arrangement outlet, inlet, overflow and washout outlet pipe arrangement as necessary & C.I.
Cover 0.60 x 0.45 weight not less then 35 kg with locking arrangement. etc. comp as per structural drawing Including Reinforcement
TMT-FE500D As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(J) Percolation Well
Item Description Unit Rate Amount
114 Boring and Sinking 30 cm. Diameter. Percolation well Excavation & Earthwork Rmt 184.00 760.00
115 Soak well around 3.0 m. dia. X 5.0 m. liquid depth including brick masonary for well Nos. 2.00 1,30,400.00
116 Brick masonry collection cum filtration tank around soak well Nos. 7.00 34,500.00
117 15 cm. diameter strainer pipes (Johnson make) having slot size 1.5 mm x 57 mm (72 slots in one line) in the casing pipe Rmt 81.00 1,830.00
Supplying, fitting, fixing and lowering 30 cm. diameter strainer pipe 1.2 m long (Johnson make) having slot size 1.5 mm x 57 mm (72
slots in one line)
119 Providing and lowering 15 cm size M.S. (3 m long) bail plug to the bore hole. Set 7.00 3,800.00
120 Supplying, lowering, fitting, fixing and joining with Strainer, 15 cm. diameter M.S. Pipe of minimum 5.40 mm wall thickness Rmt 78.00 1,175.00
121 Cement ceiling the saline zone as per logging report and as directed by the employer. Job 2.00 10,265.00
Supplying, washing and shrouding with approved gravel, the annular gap between the casing pipe and the remaining annular space to be
filled in with puddle clay (for which no measurement with be taken and paid for ).
123 Hire and labour charges for necessary tools and plants for conducting proper tests for percolation water, Nos. 2.00 14,945.00
(J) Plumbing Work
Supplying and fixing reinforced concrete heavy duty nonpressure pipes with collars for culverts including setting and joining the pipes in
124 C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Class NP4 of following internal diameter. Rmt 380.00 344.64
(I) 300 mm dia.
Providing & Laying & Jointing glazed stoneware pipes incl. excavation up to 2.0 mt.,refilling, trasporting the pipe to work site,
unloading, lowering in trenches, laying and jointing the pipes in c.m. 1:1 incl. all jointing materials such as cement, sand, hemp, bitumen
125 as dire. testing the pipe line to a head of 1.5 mt. and hydraulic test as dire incl. watering trenches, spreading ,and carting away of surplus Rmt 99.00 344.64
earth within 100 mt.lead as dire. etc.comp
(A) 230 mm dia.
Providing & laying cement concrete 1:5:10 (1- Cement,5- fine sand,10 - graded stone aggregate 40mm Nominal size ) bedding for
128 stoneware pipes of following internal diameters with necessary formwork & curing complete. Rmt 380.00 550.00
Providing & laying cement concrete 1:5:10 (1- Cement,5- fine sand,10 - graded stone aggregate 40mm Nominal size ) bedding for
129 stoneware pipes of following internal diameters with necessary formwork & curing complete. Rmt 99.00 355.48
Providing & laying cement concrete 1:5:10 (1- Cement,5- fine sand,10 - graded stone aggregate 40mm Nominal size ) bedding for
130 stoneware pipes of following internal diameters with necessary formwork & curing complete. Rmt 200.00 211.59
Item Description Unit Rate Amount
Providing & laying cement concrete 1:5:10 (1- Cement,5- fine sand,10 - graded stone aggregate 40mm&Nominal
Excavation size ) bedding for
131 stoneware pipes of following internal diameters with necessary formwork & curing complete. Rmt 132.00 125.90
Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to SI 14735-1999 of approved make for drainage system pipe line, pipe
132 shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 Rmt 141.00 822.99
mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such
as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe
133 shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 Rmt 132.00 826.88
mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such
as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 75 mm diameter with jali of the following nominal diameter of self
cleansing design with S.S. scread down or hinged grating including the cost of cutting and making good the walls.
Constructing brick masonry chamber for under ground C.I. Inspection chamber and bends with bricks having croshing strength not less
than 35 Kg. Cm2 in C.M. 1:5 C.I.cover with frame (Lightduty) 455mm x 610 mm intenal dimensions total weight of cover with frame to
be not less than 38 Kg. (Wt. of cover 23Kg.) and Wt.of frame 15Kg.) (R.C.C.top slab with 1:2:4 mix (1- cement:2 coarse sand:4-graded
stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15 mm thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete etc. complete.
(i) Inside dimensions 455 mm x 610 mm and up to 850 mm deep
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:3 (1Cement : 3-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-
Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size
900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing
strength not less than 35Kg. /Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand)
(1) A type depth 0.90 Metre
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:3 (1Cement : 3-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-
Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size
900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing
strength not less than 35Kg. /Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand)
(2) B type depth up to 1.50 Metre
Item Description Unit Rate Amount
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1cement :2-coarse sand : 4-graded stone aggregate
Excavation 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:3 (1Cement : 3-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-
Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size
900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing
strength not less than 35Kg. /Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand)
(3) C type depth 2.25 Metre
Providing and fixing Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete. (A) White earthen
ware flat back or corner type size 430mm x 260mm x 350mm
Providing and fixing 15mm dia C.P. bib cock of approved make like jaquar or Essess or any other type and make specified by the
140 Architect. All pillar cocks, stop cock, angle cock etc to be Jaquar or EssEss make with quarter turn disc ceramic cartridge and chrome Each 42.00 750.00
Providing and fixing C.P. brass angle valve for basin mixer of approved quality conforming to IS:8931 of Approved make as approved
141 by engg. in charge all complete. Each 78.00 1,041.00
15 mm Nominal Bore Dia
Providing and fixing C.P. brass shower rose with 15mm or 20mm inlet Shower Arm.
(A) 100mm dia. Each
Provdg. & laying S.W. Gully trap with C.I. garting brick masonry chamber & water tight C.I. cover with frame of 300 mm x 300 mm
size (inside) with standard weight. sqare mouth trap size 150 x100 mm P Trap
Providing erecting and fixing double coated ISI water tank of required capacity each with all necessary fittings and connection etc.
complete on terrace.
P/F PVC . (span) nahni trap and all of the following nominal dia of self cleanising design with C.I.Screw down or hinged greeting
inclusive cost of cutting and making good the walls and floors for drain 75 mm dia. etc. comp.
Provding and fixing to wall, ceiling & floor in true line and level UPVC pipe Schedule- 40 of Prince , Supreme , astral , finolex or
equivalent make as approved by engg. incharge. pipe shall be fix on wall with the help of clamp at every twi meter center to center of
146 shall be concealed as directed in cluding neccesarry fitting etc. in cluding testing of pipe and jointd and fixing the same with Rmt 132.00 71.93
adhesive solvent , including cost of all materials of following nominal bore.
Provding and fixing to wall, ceiling & floor in true line and level UPVC pipe Schedule- 40 of Prince , Supreme , astral , finolex or
equivalent make as approved by engg. incharge. pipe shall be fix on wall with the help of clamp at every twi meter center to center of
147 shall be concealed as directed in cluding neccesarry fitting etc. in cluding testing of pipe and jointd and fixing the same with Rmt 99.00 90.93
adhesive solvent , including cost of all materials of following nominal bore.
Provding and fixing to wall, ceiling & floor in true line and level UPVC pipe Schedule- 40 of Prince , Supreme , astral , finolex or
equivalent make as approved by engg. incharge. pipe shall be fix on wall with the help of clamp at every twi meter center to center of
148 shall be concealed as directed in cluding neccesarry fitting etc. in cluding testing of pipe and jointd and fixing the same with Rmt 99.00 117.97
adhesive solvent , including cost of all materials of following nominal bore.
Item Description Unit Rate Amount
Provding and fixing to wall, ceiling & floor in true line and level UPVC pipe Schedule- Excavation
40 of Prince , &
Supreme , astral , finolex or
equivalent make as approved by engg. incharge. pipe shall be fix on wall with the help of clamp at every twi meter center to center of
149 shall be concealed as directed in cluding neccesarry fitting etc. in cluding testing of pipe and jointd and fixing the same with Rmt 99.00 146.65
adhesive solvent , including cost of all materials of following nominal bore.
Provding and fixing to wall, ceiling & floor in true line and level UPVC pipe Schedule- 40 of Prince , Supreme , astral , finolex or
equivalent make as approved by engg. incharge. pipe shall be fix on wall with the help of clamp at every twi meter center to center of
150 shall be concealed as directed in cluding neccesarry fitting etc. in cluding testing of pipe and jointd and fixing the same with Rmt 99.00 193.73
adhesive solvent , including cost of all materials of following nominal bore.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling
& testing of joints complete as per direction of Engineer in Charge.
Item Description Unit Rate Amount
Provding And fixing to wall ,ceiling and floor 10.00 kg. F/Sq.Cm working pressure polythelene Excavation & Earthwork
pipes of the following outside
158 diameter, low, density, complete with special flange compression type fittings, wall clips etc. making good wall ceiling and floor. Rmt 66.00 274.68
Provding And fixing to wall ,ceiling and floor 10.00 kg. F/Sq.Cm working pressure polythelene pipes of the following outside
159 diameter, low, density, complete with special flange compression type fittings, wall clips etc. making good wall ceiling and floor. Rmt 190.00 332.91
Providing & fixing Wall-mounted European Closet SuiteCera 'Clair' model No 2035 P-Trap (White/Light Coloured) with Dual Flush
Tank , PVC pan connector, seat & lid (heavy duty) including C.I. Brackets,C.P. Flush cock, C.P. brass hinges, All Internal fittings
complete with rubber buffers, C.P. nuts, bolts, ChaKi, etc making holes in walls & floors, & finishing for ready to use.The rate includes
160 Providing & fixing 15mm Angle Valve as per product detail with braided hose pipe as per product detail, jet spray as per product detail Each 23.00 5,688.00
including cutting and making good the wall where required.( Ewc wall hung-p :Cera. (white/light coloured) Classic no.2037 or
equivalent, Chair bracket : Cera no:2434 or equivalent brand make, rag bolts, Dual Flush Cistern : Cera ( white/light coloured) no:
or equivalent, Angle cock: Jacquar no 051 continental or equivalent, Braided hose: Jaquar-Allied-803B-CP)
HANDICAP TOILET
Providing and Fixing Handicap Toilet set including EWC, Cistern, Seat Cover, Fittings, Washbasin,, Hinged Rail, Grab Bar and Faucet
with Spatula Lever including Cast Iron chair backed and necessary bolts and nuts complete, including painting of fittings and brackets,
cutting and making good the walls and floors wherever required to the satisfaction of Engineer-In-Charge. Special Needs Toilet Set:
Jaquar - CNS-WHT-755SN + Cistern Set CNS-WHT-207, Wash Basin CNS-WHT-811 & Grab Bar 2 No. - WAC-WHT-BG0800 &
WAC-WHC-BR0600 - 2 nos.+ or Equivalent approved Make. Rates includes all lead & lift as directed by EIC.
Providing and fixing metropole flush valve (jaquar catlog No FLV-1089) (self closing spring loaded) at any floor, level and height.
Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets painted white including sutting holes and
163 making good the same but including fittings. Nos. 26.00 3,513.00
(A) Vitreous China: (ii) Flat Back washbasin 550mm x 400mm size. (i) In White Colour.
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to wooden plugs with C.P. brass scews.
(B) 600mm x 20mm size.
Providing and fixing pillar tap, capstan head, screw down high pressure with screws, shanks and back nuts.
Providing and fixing screw down bib taps of following size.
166 (A) Brass screw down bib tap polished bright. Each 42.00 212.68
Supply,Installing, tesitng and commissioning concealed forged brass lever operated ball valve of full flow with forged brass ball
(Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum
167 working pressure of 16 kg/cm2 etc. including providing of connectors, flanges, nuts, bolts, gaskets, etc as per drawings, specification and Each 13.00 1,133.93
as directed by the EIC.
Supply,Installing, tesitng and commissioning concealed forged brass lever operated ball valve of full flow with forged brass ball
(Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum
168 working pressure of 16 kg/cm2 etc. including providing of connectors, flanges, nuts, bolts, gaskets, etc as per drawings, specification and Each 13.00 2,267.86
as directed by the EIC.
Item Description Unit Rate Amount
Supply,Installing, tesitng and commissioning concealed forged brass lever operated ball Excavation
valve of full & flow with forged brass ball
(Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum
169 working pressure of 16 kg/cm2 etc. including providing of connectors, flanges, nuts, bolts, gaskets, etc as per drawings, specification and Each 11.00 3,574.11
as directed by the EIC.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
Constructing Bombay Pattern Type Catch Pit of size 0.60 x 0.60 depth up to 1 mt including excavation, B.B.C.C. (1:5:10), 23 cms thick
173 brick maso. wall in the prop. of CM (1:6) with 40 mm thick IPS flooring in the prop M15 at bottom and 15 mm thick cement plaster Nos. 13.00 3,125.00
inside the catch pit in the proportion of CM (1:3) with out jali etc. comp. as directed.
174 CatchPit Jali Fixing P/F FRC catch pit jali with frame 600mm x 600mm clear opening etc. comp.. As directed by engineer in charge. Nos. 13.00 1,383.93
Total Amount of Civil, Site Development & Plumbing Work
Total Amount of Civil, Site Development & Plumbing Work
Ahmedabad Municipal Corporation
Construction of Swimming Pool at T.P.-128, F.P.-493 in Vatva Ward, South Zone, Ahmedabad.
BOQ - Electrical, ELV & Heating Ventilation & Air - Conditioning Work
SR. No. Item No. Description of Work Unit Rate Amount
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected
concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories
and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered
with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Wiring for the light points as above but with IP66 Switch board with IP 66 Box and 6 Amp / 16 amp
2 E-2 Switch. 250 Volt one 6 A IP66 switch located on IP 66 box board of Legrand cat. No. 673000 & 684638 2.00 Nos. 2,040.00
3 E-3 Primary light point controlled by one SP MCB ( Same as above item but controlling with SP MCB ) 2.00 Nos. 525.00
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected
concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with
4 E-4 primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / 135.00 Nos. 131.00
Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as
(a) with medium class Rigid PVC pipe and accessories
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both
are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to
be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following
5 E-5 type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / 2.00 Nos. 562.00
metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle
holder or ceiling rose or H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories
6 E-6 Do as above but for Secondary light point controlled by same two way switch 2.00 Nos. 192.00
SR. No. Item No. Description of Work Unit Rate Amount
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in /
flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type
electronic fan regulator with separately mounted and accessories with earth continuity of following type
erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as
(a) with medium class Rigid PVC pipe and accessories
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box,
8 E-8 single mounting base frame covered with textured / metallic front plate modules erected on / in wall / 35.00 Nos. 255.00
ceiling with following type accessories
Do - As - Above but for 6 A x 5 pin 250 Volt switched socket outlet point at convenient location. ( Plug &
Switch can be together or at different location )
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on
surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box
10 E-10 covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following 20.00 Nos. 704.00
type of accessories.
[II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories
Wiring for the 250 volts single phase and neutral 16 amps switched socket outlet with 4.0 sq.mm
FRLS flexible copper conductor 1100 volts grade wires of approved make with concealed or surface
11 E-11 mounted 25 mm dia medium gauge PVC Conduit including providing and fixing of 16 amps 5 pin switch 12.00 Nos. 829.00
socket outlet of approved quality color make & design in 2 mm thick GI box and earthing of fixtures
and the outlet box with 2.5 sq.mm PVC insulated copper conductor stranded flexible "FRLS" wire.
Wiring for the UPS / Comp. / Raw Power outlet with 2 nos. of 250 volts single phase and neutral 16 amps
switched socket outlet with 2.5 sq.mm x 3 core FRLS flexible copper conductor 1100 volts grade
wires of approved make in concealed or surface mounted Prelaid 25 mm dia medium gauge PVC
Conduit / Race ways including providing and fixing of 2 no's of 16 amps 5 pin switch socket outlet of
approved quality color make & design in 2 mm thick GI box and earthing of fixtures and the outlet
box. ( Maximum 3 nos. of Plugs can be looped in 1 Circuit )
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in approved manner as directed
Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness
14 E-14 Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness 350.00 Rmt 52.00
15 E-15 Supply and laying of 40 mm rigid PVC pipe of 1.6-1.8 mm thickness 200.00 Rmt 64.00
SR. No. Item No. Description of Work Unit Rate Amount
MAINS : ( not for Point wiring )
Supplying and Laying of mains with Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/
1100 V with earth wires of Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth
wires with Suitable dia rigid PVC Pipe of Heavy Gauge ( Scope Also includes Supply of pipe. )
Supplying and Laying of 4 nos. of 10 sq mm Cu. FRLS flexible wires with 2 nos 4 sqmm Cu. FRLS
flexible wireswith 40 mm dia Pipe
Supplying and Laying of 2 nos. of 6 sq mm Cu. FRLS flexible wires with 1 nos 2.5 sqmm Cu. FRLS
flexible wires with 40 mm dia Pipe
Supplying and Laying of 2 nos. of 4 sq mm Cu. FRLS flexible wires with 1 nos 2.5 sqmm Cu. FRLS
flexible wires with 25 mm dia Pipe
Supplying and Laying of 2 nos. of 2.5 sq mm Cu. FRLS flexible wires with 1 nos 1.5 sqmm Cu. FRLS
flexible wires with 25 mm dia Pipe
Supplying and Laying of 2 nos. of 1.5 sq mm Cu. FRLS flexible wires with 1 nos 1.5 sqmm Cu. FRLS
flexible wires with 25 mm dia Pipe
Distribution Board
Supply, Assembling, grouting, leveling Connecting & testing D.B of IP 54 of specified make.
Distribution Board-VTPN
Supply, Erecting, testing and commissioning of only VTPN D.B. with space for FPMCCB / FPMCB as
incoming and 4 TPMCB / SPMCB as outgoing per phase (i.e. 4 way VTPN D.B.) of Legrand Make Cat.
Distribution Board-TPN
Supply, Erecting, testing and commissioning of only TPN D.B. PPI type with space for FPMCB as incoming
and space for DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way per phase D.B.) of Hensel Make
Distribution Board-SPN
23 E-23 Supply, Erecting, testing and commissioning of SPN D.B. PPI type with space for DPELMCB as incoming 2.00 Nos. 3,860.00
and 8 SPMCB as outgoing per phase (i.e. 12 way D.B.) of Hensel Make KV9112M
Supply, Erecting, testing and commissioning of SPN D.B. PPI type with space for DPELMCB as incoming
and 4 SPMCB as outgoing per phase (i.e. 8 way D.B.) of Hensel Make KV7109M
All MCB's, ELMCB's, ELCB's should be of 10 KA only
25 E-25 providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and having breaking capacity 8.00 Nos. 268.00
10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
SR. No. Item No. Description of Work Unit Rate Amount
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking
32 E-32 capacity & confirms to IS :8828 in existing box having following capacity 5.00 Nos. 582.00
(a) 6 to 32 Amp. Cat.III
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking
33 E-33 capacity & confirms to IS :8828 in existing box having following capacity 5.00 Nos. 641.00
(b) 40 Amp. Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having following capacity
6 to 32A FP MCB
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity
ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic
release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing. .
ICS= 100% of ICU only.
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate
battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A
with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised
permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary connection erected as directed.
Supplying & erecting power contactor ,AC3 duty for time switch complete erected as per direction Cat III
(B) 2 pole 250V 32 Amp.
Supplying & erecting power contactor ,AC3 duty for time switch complete erected as per direction Cat III
(D) 4 pole 440V 40 Amp.
41 E-41 SITC of IP65 Polycarbonate enclosure for DP MCB 2.00 Nos. 1,882.00
42 E-42 SITC of IP65 Polycarbonate enclosure for FP MCB 2.00 Nos. 1,995.00
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the
run and backfilling the same and making the surface proper. Providing and erecting iron clad cable route
marker duly marked with ELE.CABLE of size 23 cms.X 12 cms. Flushed with ground in cement foundation
as directed by Engineer in charge. The width shall be as per requirement
SR. No. Item No. Description of Work Unit Rate Amount
Covering of cable with second class bricks laid cover the cable crosswise & also on both sides with covering
of 7. 5 Cms. layer of sand above & below cable (cable shall be laid in 0.9mtr.deep & 0.4 Mtr.wide trench).
44 E-44 Where there are more than one cable in the trench on either side of the cable, 5 Cms. over lapping of bricks 200.00 Rmt 139.00
shall be provided.
Construction of brick masonry pulling chamber 600 mm x 600 mm inside clear size and depth up to
meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM
proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum
45 E-45 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame 3.00 Nos. 10,423.00
and 600 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling &
clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of
the Engineer In charge complete in all respect.
Construction of brick masonry pulling chamber 750 mm x 750 mm inside clear size and depth up to
meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM
proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum
46 E-46 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame 3.00 Nos. 13,138.00
and 750 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling &
clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of
the Engineer In charge complete in all respect.
Construction of brick masonry pulling chamber 1000 mm x 1000 mm inside clear size and depth up to
meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM
proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum
47 E-47 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame 12.00 Nos. 16,746.00
and 900 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling &
clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of
the Engineer In charge complete in all respect.
Fabricating the box type items made from M.S. Sheet with A.I. supports, wings, doors, handles other
48 E-48 hardware materials as per requirement design with finishing by three tank powder coating processed inside 500.00 Kg 179.00
and outside painted, erected as directed including minor civil work.
Supply, Installation, Testing, Laying, Commissioning of following 1100 volt grade XLPE insulated PVC
sheathed aluminum / Copper conductor armored cables as per (IS:7098)(I)-88 ISI marked & specification in
trenches, cable trays, ducts, over bed of sand, clamped to wall with suitable clamps including, saddles fixing
bolts, connecting testing and commissioning with identification tags at every 10 mtr. & Both ends. with All
the fixing accessories, excavation Back filling & Cable protection with Bricks as per the drawing ( If
70 sq.mm x 3.5 c Al. XLPE Arm. Cable
50 E-50 50 sq.mm x 3.5 c Al. XLPE Arm. Cable 50.00 Meter 282.00
SR. No. Item No. Description of Work Unit Rate Amount
51 E-51 25 sq.mm x 4 c Al. XLPE Arm. Cable 80.00 Meter 189.00
52 E-52 16 sq.mm x 4 c Al. XLPE Arm. Cable 500.00 Meter 152.00
53 E-53 10 sq.mm x 4 c Al. XLPE Arm. Cable 200.00 Meter 139.00
54 E-54 6 sq.mm x 4 c Cu. XLPE Arm. Cable 100.00 Meter 505.00
Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand copper conductor for 1.1 KV.
To be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following
55 E-55 size cable. 50.00 Meter 392.00
6 sq.mm x 3 c cu. XLPE Arm. Cable
Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand copper conductor for 1.1 KV.
To be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following
56 E-56 size cable. 80.00 Meter 282.00
4 sq.mm x 3 c cu. XLPE Arm. Cable
57 E-57 Supply & Laying of 1.5 sq mm x 3 core round flexible wire in prelaid pipe / Raceway. 50.00 Meter 46.00
58 E-58 Supply & Laying of 2.5 sq mm x 3 core round flexible wires in prelaid pipe / Raceway. 75.00 Meter 77.00
59 E-59 Supply & Laying of 4 sq mm x 4 core round flexible wires in prelaid pipe / Raceway. 30.00 Meter 175.00
Cable Termination
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor
60 E-60 armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, 4.00 Nos. 197.00
double compression type Brass glands with earthing.
70 sq.mm x 3.5c Al. XLPE Arm. Cable
61 E-61 50 sq.mm x 3.5c Al. XLPE Arm. Cable 2.00 Nos. 150.00
62 E-62 25 sq.mm x 4 c Al. XLPE Arm. Cable 2.00 Nos. 111.00
63 E-63 16 sq.mm x 4 c Al. XLPE Arm. Cable 44.00 Nos. 107.00
64 E-64 10 sq.mm x 4 c Al. XLPE Arm. Cable 10.00 Nos. 90.00
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor
armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs,
65 E-65 double compression type Brass glands with earthing. 6.00 Nos. 62.00
6 sq.mm x 4 c Cu. XLPE Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor
armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs,
66 E-66 double compression type Brass glands with earthing. 4.00 Nos. 51.00
6 sq.mm x 3 c Al. XLPE Arm. Cable
SR. No. Item No. Description of Work Unit Rate Amount
SITC of Cable end termination of the following XLPE insulated PVC sheathed aluminum/copper conductor
armored cables of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs,
67 E-67 double compression type Brass glands with earthing. 6.00 Nos. 51.00
4 sq.mm x 3 c Al. XLPE Arm. Cable
SITC of Round Flexible wire end termination of the following insulated PVC sheathed copper conductor
Wires of 1100 volt grade including supplying and fixing of bimetallic Long neck crimping lugs, IP66 / 67 -
3 mm thick Thermoplastic long entry glands of Hensel / Spelsberg with Strain relief and Lock nut.
1.5 / 2.5 Sq. mm x 3 / 4 core round flexble wire or Similar dia wire
69 E-69 4 / 6 Sq. mm x 3 / 4 core round flexble wire or Similar dia wire 4.00 Nos. 51.00
MV Switchgear & Power Panels
Supply, Unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, &
Commissioning main L.T. panel board, fabricated from M.S. sheet & folded channel totally enclosed
cubical type compartmentalized. Scope Covers Unloading at Site, Store in Weather Proof Condition, Shift to
the Location Basement / GF / FF, Grouting, Installation, Testing & Commissioning complete in all respect
& As per the instruction of Architect / Consultant / Engineer Incharge. Scope also covers Co ordination with
Panel Manufacturer.
Design, fabrication, assembling, supply, installation , testing of Panels for 415 V, 3 phase, 50 Hz, 4 wire
power supply system.
Panels shall be fabricated out of 2 mm thick CRCA sheet steel in cubical formation, compartmentalized in
Form 4b Construction, floor mounted, free standing and shall be dust and vermin proof. 3 mm thick cable
gland plate, shall be provided both at the top and the bottom of the panel.
All large panels shall be provided with lifting hooks. Distribution panels shall be fabricated in accordance
with the specifications.
Note : Panel vendor has to provide Surge Protection at every stage of the Distribution.
1) Supporting rigid steel framework.
2) Cubicle type, 14 gauge CRCA sheet steel enclosed.
3) Complete with interconnections and distribution bus bars.
4) Proper bonding to earth.
5) Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram.
6) Providing cable clamps / supports within distribution boards cable alley.
7) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.
8) All MCB’s shall be of minimum 10 KA breaking capacity.
9) The breaking capacity of MCCB’s are mentioned panel wise.
10) All motor feeders MCCBs shall be of motor duty.
11) Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.
SR. No. Item No. Description of Work Unit Rate Amount
12) Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.
a) IP 52 for indoor panels.
b) IP 54 for kitchen and laundry panels.
c) IP 55 for outdoor panels.
13) All MCCB’s shall be provided with operating mechanism for door interlock & with the roraty handle.
14) Current density of aluminium shall be 1 sq mm for 0.8 amps for rated current of bus bars and current
density of copper shall be 1 sq.mm for 1 amps for rated current of bus bars.
15) Tinned copper earth bus as specified in the BOQ / SLD shall be provided through out the length of each
16) All measuring instruments (Meters) shall be of digital electronic with LED of approved make and
compatible with BAS.
17) All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
18) All panels shall have provision of the following:
a) IP 55 for outdoor panels.
b) Pad locking of MCCB’s handles in “OFF” Position.
19) Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided
for BAS including space required for various transducers in Main Switch Board sections. Only transducers
shall be supplied by BAS contractor.
20) All the C.T.s should be auto short link type.
21) All the MCCB's should be with rotary handle.
22) All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and
inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type
D characteristic.
23) All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single
tier formation.
24) All PTs / control transformer shall be provided with centre tap earth secondary.
25) If Any descripancy found in SLD & BOQ, it should be brought in the notice of the Client / Consultant,
Client / Consultant's decision will be final in case of any descripancy.
26) G.A. Drawing should be checked & Finalised by consultant before fabrication.
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity
ICU of 35 KA. at 415 V. having Normal current rating 200A.with variable Thermal & magnetic release
70 E-70 suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete 2.00 Nos. 16,061.00
erected in existing 16 G.M.S.housing
ICS=100% of ICU only Cat III
SR. No. Item No. Description of Work Unit Rate Amount
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity
ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic
71 E-71 release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & 1.00 Nos. 6,112.00
complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III
Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet, dust &
vermin proof having hinged door with rubber gasket and necessary busbar supports with COPPER busbar
having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped
72 E-72 with colour insulation tape for phase sequence, three phase & neutral each suitable for following current 5.00 Rmt 4,378.00
capacity with necessary painting mounted on wall or pedestal frame of required size with necessary
(A) Suitable for 63/100 Amp. capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four
equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm (Rated current / cross section
area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing
cubical panel with necessary connections.
(E) Suitable for 200 Amp. capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal
Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section
area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in existing cubical
panel with necessary connections.
(A) Suitable for 100 Amp. Capacity
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, complete erected
with necessary connections.
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden erected
in existing CRCA box duly secured with insulating materials connected to the meter
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display,
77 E-77 0 to 750 AC Volts range erected on existing panel board with all connection, wiring etc .with 4.00 Each 1,263.00
manufacturers calibration certificate.
Supplying and erecting approved make panel mounting type Digital Ammeter having 3 digits LED
78 E-78 display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate on 500 Volt AC , erected on 4.00 Each 1,543.00
existing panel board with all connection, wiring etc .with manufacturers calibration certificate.
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to
following size of moulded case circuit breaker having CT ratio & MCCB rating as following along with
shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing..
SR. No. Item No. Description of Work Unit Rate Amount
Providing and erecting multifunctional meter suitable for application of Power monitoring and showing
measurement of following Voltage, Frequency, Apparent energy, Apparent power, Active and reactive
energy, Active and reactive power, Average voltage Vavg, Peak demand power PM, QM, SM, Demand
power P, Q, S, Apparent power S, S1, S2, S3, Unbalance current, Power factor and displacement PF (signed,
four quadrant), Calculated neutral current, Active, reactive, apparent energy (signed, four quadrant), Active
power P, P1, P2, P3, Voltage U21, U32, U13, V1, V2, V3, Phase currents, Average current Iag, Peak
demand currents, Reactive power Q, Q1, Q2, Q3, Demand current I1, I2, I3, [Us] rated supply voltage
40...300 V AC 45...65 Hz, 40...300 V DC, Network frequency 50 Hz, Type of network 3P, Display type
segments LED, Display colour Red, Messages display capacity 3 fields of 4 characters, Display digits
digit(s) - 14.2 mm in height
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical
panel board necessary IP-42 and above protection as per approval from engineer incharge made from
SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions
with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding,
riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with
erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-
82 E-82 aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & 8.00 Sqm 14,755.00
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating. (The rates
excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters,
Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with
following approved manufacturers with following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory
(i) with 350mm depth
83 E-83 (ii) with 550 mm. Depth 5.00 Sqm 19,196.00
84 E-84 (iii)with 750 mm. Depth 8.00 Sqm 33,230.00
SR. No. Item No. Description of Work Unit Rate Amount
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical
panel board necessary IP-42 and above protection as per approval from engineer incharge made from
SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions
with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding,
riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with
erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-
aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating. (The rates
excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters,
Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with
following approved manufacturers with following size.
(C) The standard companies switch gear shall be used and only manufacturers as per IEC 61439 for
beneficial use.
(iii)with 750 mm. Depth
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%, CCT 3000 K to 6500K,
86 E-86 Luminaire efficacy> 85 lumens/watt ,LED LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 18.00 Nos. 370.00
Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet, Cat-III
SR. No. Item No. Description of Work Unit Rate Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED LED driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet, Cat-III
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to 270V,Power Factor more than 0.9,
THD < 15 %, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting
clips complete.IP20
(i) 5-9 watts,Surge-2 KV
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to 270V,Power Factor more than 0.9,
THD < 15 %, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting
clips complete.IP20
(iii) 16-20 watts, Surge-2 KV
SR. No. Item No. Description of Work Unit Rate Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
90 E-90 Luminaire efficacy> 85 lumens/watt , 5.00 Nos. 1,777.00
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing
(vi) 36 watts, 24" x 24", Surge- 2KV
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
91 E-91 ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 22.00 Nos. 4,948.00
& LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
over-voltage protection.
(ii) above 48 to 60 Watts
Providing and erecting PVC body surface or pendent mounting LED Bulk type 9 watt Lighting Fitting with
electronic driver. And lumen output from luminaire 720lm , input voltage range 90-300VAC , 50Hz cool
white(3000 to 6500k), inbuilt driver, -20degC to +60degC working temperature, AL frame with Beam Angle
SR. No. Item No. Description of Work Unit Rate Amount
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
93 E-93 ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 2.00 Nos. 5,917.00
& LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
over-voltage protection.
(iii) Above 60 to 90 watts
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
94 E-94 ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 2.00 Nos. 6,501.00
& LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
(iv) above 90 to 120 watts
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
95 E-95 ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 2.00 Nos. 8,370.00
& LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
(v) above 120 to 160 watts
SR. No. Item No. Description of Work Unit Rate Amount
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
96 E-96 ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 46.00 Nos. 10,711.00
& LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
(vii)above 200 to 250 watts
97 E-97 Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM 2.00 Nos. 1,687.00
with square frame ABS body with inbuilt lowers & square frame.
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring
mounted low noise operation suitable for medium duty having following dia size and maximum speed in
[A] 305 mm dia 900 RPM
99 E-99 Providing suitable M.S. louver shutter of the Exhaust fan. 20.00 Nos. 365.00
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser
100 E-100 volt A.C.50 Hz. 1200 mm sweep complete having 4 blades Aluminium body and blade sets having 32.00 Nos. 2,335.00
ornamental design shanks, canopy erected with earthing [ Make shall be approved by Engineer in Charge]
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted
101 E-101 for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing. 32.00 Rmt 107.00
SR. No. Item No. Description of Work Unit Rate Amount
Supply of approved make FRP Pole having following specifications: FRP Light Pole made by CNC
filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass
content. The pole should be in one piece and tapered round in shape, having smooth finish and should be
totally free from corrosion as well as non conductive & shock proof Pole should be provided with FRP
Anchor Base and it should be heavy duty, or MS Material duly painted with Epoxy paint. Pole should be
flame retardant as per IS 6746. Resin used shall be UV resistance and pigmented. A highly weather resistant
polyurethane coating shall be applied to the pole after applying suitable primer system that ensures proper
adhesion of the paint. Minimum coating thickness shall be 80 to 100 micron. Deflection of the pole shall not
exceed more than 10% of the length of pole for the given load“ Pole should be generally made as per the
dimensional data, performance criteria and some interchangeability features of poles as per standard ANSI
C 136.20 latest version or ASTM D 4923/01 including cable termination box with necessary accessories .
The size of pole and type of installation with foundation as per manufacturer details and site requirement are
(2) Suitable for base plate mounting Double arm Bracket.
[C] Overall length of 6 Mtr. Average Thickness: 8mm.
Top/ Bottom OD Dia A/F 114/174 mm ± 2mm approx. approx. Weight of Pole 38 kg approx. (Without
Base) Anchor Base (Size 300X300 & 18mm th.)
Supply of approved make FRP Pole having following specifications: FRP Light Pole made by CNC
filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass
content. The pole should be in one piece and tapered round in shape, having smooth finish and should be
totally free from corrosion as well as non conductive & shock proof Pole should be provided with FRP
Anchor Base and it should be heavy duty, or MS Material duly painted with Epoxy paint. Pole should be
flame retardant as per IS 6746. Resin used shall be UV resistance and pigmented. A highly weather resistant
polyurethane coating shall be applied to the pole after applying suitable primer system that ensures proper
adhesion of the paint. Minimum coating thickness shall be 80 to 100 micron. Deflection of the pole shall not
exceed more than 10% of the length of pole for the given load“ Pole should be generally made as per the
dimensional data, performance criteria and some interchangeability features of poles as per standard ANSI
C 136.20 latest version or ASTM D 4923/01 including cable termination box with necessary accessories .
The size of pole and type of installation with foundation as per manufacturer details and site requirement are
(2) Suitable for base plate mounting Double arm Bracket.
[G] Overall length of 8 Mtr. Average Thickness: 8mm, Top/ Bottom OD Dia A/F114/195 mm ± 2mm
approx. approx. Weight of Pole 54 kg approx. (Without Base) Anchor Base (Size 350X350 & 20mm th.)
Providing Aluminium arm bracket of having 2 sets of suitable SS304 hardware for fixing the brackets &
104 E-104 spread of 1.2 Mtr (Suitable for 89 to 114 mm pole top dia) 18.00 Nos. 2,212.00
(A) Single arm bracket
SR. No. Item No. Description of Work Unit Rate Amount
105 E-105 (B) Double arm bracket 4.00 Nos. 3,416.00
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of
M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding &
finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge
with necessary grouting, cementing, plastering & finishing complete.
Providing cement concrete.for foundation or for concrete filling in 1:2:4 ratio with 20 to 25 mm stone metal
duly plastered with necessary curing for pole muffing or any other purpose.
108 E-108 TMT Bar for Pole Foundation 150.00 Kg 75.46
Supplying & erecting funnel type earthing having earth plate of following size burred in specifically
prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt,
20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover
109 E-109 complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 2.00 Nos. 7,797.00
6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to
the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS (As
per drawing) with following specification
60 x 60x 0.315 cms. Copper earth Plate
110 E-110 45 x 45 x 0.35 cms. C.I. earth plate 2.00 Nos. 2,543.00
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or approved make Safe Earthing
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having
Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250
Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of applications.
For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant &
Sensitive Computer System(like Automation, SCADA)i.e. independent Earthing located in other
than normal soil i.e. Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
Earth wire/strips :
Supply and laying cu. earthing strips for interconnecting the earthing stations, panels, DB's etc. in built up
trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with :
fixing accessories
Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes.
Providing and erecting HOT deep Galvanized strip iron wire 8 to 16 S.W.G.
115 E-115 No.8 gauge bare cu. earth wire 25.00 Kg 815.00
116 E-116 Earth Link : 40mm x 6 mm earth link fixed by necessary screws on wall. 2.00 Meter 370.00
SR. No. Item No. Description of Work Unit Rate Amount
SITC of Water Tight Junction Box With necessary clamp for mounting of the J.B. ( All the cable / wire
117 E-117 connections to the JB shall be with the Water tight Glands only ) 14.00 Nos. 2,940.00
Telephone Outlet Point
SITC OF PowerCat 6 DataGate Jack, 568A/B - Yellow with Dust Cover / Blank/ One Telephone Point to be
118 E-118 done with Cat -6 Information outlet Socket, Back Box, Face Plate for all telephone point. Average Length to 8.00 Nos. 159.00
be considered as 50 Meter. Cable Laying, Labling, Ferrule, Testing, Certification to be included in cost.
Years of Certification is required. Test reports of Level-4 Scanners only.
SITC OF DG+ Jack (Diecast)Cat6A 568A/B, Shtd- Black (Information Outlet for Data) with Faceplate,
back box CAT-6A standards. Cable Laying, Labling, Ferrule, Testing, Certification to be included in cost.
20 Years of Certification is required. Test Reports of Level-4 Fluke Scanners Only.
SITC of Jack Panel, fully loaded with 24 nos. UTP ports for PCB based IO Jacks (RJ45, TIA-568C
Category-6, Installation and Termination of all 24 nos. Catergory-6 UTP , unloaded with individually
120 E-120 replaceable 24 nos. Category-6 I/O Jacks complying with TIA-568.C.2, as per given jack specification Shall 1.00 Nos. 4,357.00
be suitable for loading unshielded & shielded jacks for different category systems (CAT 6 & CAT 6A)
Supply and laying of PowerCat 6A U/FTP CM 4 Pair Cable, LSZH Sheath - Violet of specified make to be
done in prelaid PVC pipe of 25 mm dia / raceway of specified make, but without the cost of raceway or
121 E-121 pipe ( the wire is to be drawn from HUB \ Switch of respective area to outlet point ) with the cost of the 500.00 Meter 190.00
crimping with material of make Legrand / Molex/ Systimax / Panduit / Siemon
Fire Detection System
Supply, Installation, Testing And Commissioning of UL864, 10th Edition Microprocessor based 1 loop,
True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 50 characters LCD
display, 2000 event plus 500 alarm log history events, QWERTY keypad for programming. The panel
should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each
loop shall have a capacity of minimum 50 analog addressable devices. The panel shall work in degrade
mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels,
122 E-122 flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries 1.00 Nos. 35,000.00
sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be compatible with
Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation
Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of
supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU
shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having
minimum 5 Telephones in conference in multiple FFT Risers.
SR. No. Item No. Description of Work Unit Rate Amount
Supply, Installation, Testing And Commissioning of UL Listed Graphics User Interface for Monitoring &
Control of complete Fire, Voice Evacuation & Telephone Talkback System. The GUI based main network
software shall network with other panels on True Peer-to-Peer network. It shall be capable of graphically
representing each facility being monitored with floor plans and icons depicting the actual locations of the
various systems, and / or sensors’ locations. It shall have the facility to change the sensitivity of any
123 E-123 detector. The software shall be capable of monitoring 100 Nodes with 100 Mbps Transmission rate on Fibre 1.00 Nos. 35,000.00
Optics Network and 12 Mbps Transmission on cable and 1,00,000 network points. The software shall be
capable to Monitor & Control all the Digital Voice Evactuation as well as 2 way communication from main
control room using voice signals over Fire Network along with the Fire detection signal. The Graphic
workstation shall act as an independent node communicating on the peer to peer network and shall not be
dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of GUI.
Supply, Installation, Testing And Commissioning of Automatic printer capable for interface with NCS and
provided with RS 232/RS 485 protocol port. It shall be standard cartage with 80 characters per line as per
all requirements of technical specifications & contracts works.
Supply, Installation, Testing And Commissioning of UL268, 7th Edition Addressable Multi-criteria Photo-
Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device
shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric
signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to
125 E-125 distinguish between a fire condition and a false alarm condition by examining the characteristics of the 30.00 Nos. 5,344.00
thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive
phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user
friendly rotary decimal switches.
Supply, Installation, Testing And Commissioning of UL listed Addressable Manual Call Point (Pull down /
Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on
activation to monitor the heath status of the device.
Supply, Installation, Testing And Commissioning of UL Listed Sounder cum Strobe rated at 80 dBA @ 3m
127 E-127 for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed 1.00 Nos. 7,061.00
Supply, Installation, Testing And Commissioning of Addressable Control Module for Sounders / Strobes /
Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The
device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath
status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be
supplied with mounting plate from OEM for ease of installation & maintenance.
SR. No. Item No. Description of Work Unit Rate Amount
Supply, Installation, Testing And Commissioning of UL Listed Isolator Module for Isolating short / dewired
/ loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that
case needs to be considered with each detector & module. The device shall have an LED which shall blink
in normal state & get steady on activation to monitor the heath status of the device. Module shall be
supplied with mounting plate from OEM for ease of installation & maintenance.
Supply, installation, testing & Commissioning of Battery pack suitable for back up of 4 hours with charger
130 E-130 in case of Alarm condition. 1.00 Nos. 36,316.00
Supply, installation, testing & Commissioning of response indicator
Supply, installation, testing & Commissioning Fire Exit Signage boards with 3hrs battery backup
Supply & laying of 2 Core X 1.5 sq.mm. FRLS Armoured PVC Insulated copper cable
Supply & laying of 4 Core X 1.5 sq.mm. FRLS Armoured PVC Insulated copper cable
Supply, Installation, Testing & Commissioning of Network TDN IR Mini Dome Camera, 1/2.9" CMOS,
MP @ 25fps, Triple stream, Min. Illumination required 0.25 lux @ color, WDR 120dB, Min. Pixels 2560 x
1920, Shutter Speed 1/30000 - 1/5; Adavance Video Compression technology such as H.265 / H.264 /
MJPEG, 3mm~8mm, MFZ lens, HLC, 3DNR, Minimum Edge Intelligence Video Analytics: Motion
Detection, Camera Tampering, Intrusion/Object enter area; 4 nos Privacy Mask, Smart IR with upto 30m IR
distance, AES-128/256, PCI Data Security Standard compliance, 128GB SD card support, DC12V, PoE
(IEEE 802.3af) (Class 2), IP 66, IK10, Having Operating temp range : –10°C to 50° C. Certifications:
ONVIF Profile S, G compliant, UL, CE/EN, FCC Part 15 & RoHS compliant along with mounting brackets
suitable for Cieling / Wall mounting & required accesories as per site requirement.
SR. No. Item No. Description of Work Unit Rate Amount
Supply, Installation, Testing & Commissioning of 5MP IP Network TDN IR Bullet Camera, 1/2.8" CMOS,
5 MP @ 25fps, Triple stream, Min. Illumination required 0.05 lux @ F1.4 (color), WDR>120dB, Min.
Pixels 2560 x 1920, Shutter Speed 1/30000 - 1/30; Adavance Video Compression technology such as H.265
HEVC / H.264 / MJPEG, Smart Codec, 2.7-13.5 mm 5X motorized focus & zoom lens, P-IRIS, HLC,
3DNR, Minimum Edge Intelligence Video Analytics: Motion Detection, Video Tampering, Intrusion,
Loiter, Line crossing, Unattended object, Missing object, Face detection; 5 nos Privacy Mask, 4 IR LEDs
Smart IR with upto 60m IR distance, Stream encryption, AES-128/256, PCI Data Security Standard
compliance, FIPS Chipset Built-In, 256GB SD card support with SD card encryption, Dual channel Audio
G.711a / G.711 Mu / G.726, Alarm: 2 In/ 1out, In-built Heater; PoE+ (802.3 at) and 12V DC/24V AV; IP
/ IP 67 / NEMA 4X, IK10, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S,
G compliant, UL, CE (EN 50130-4 & EN 55032) , FCC Part 15 & RoHS compliant along with mounting
Brackets suitable for Pole / Wall mounting & required accesories.
SITC of 32 Channel NVR having features smart H.265+/H.265/ Smart H.264/H2.64/MJPEG, Max
137 E-137 Mbps incoming Bandingwidth, support min 2 SATA HDDs Slot - each slot supporting min 8TB, Up to 12 1.00 Nos. 64,975.00
MO Resolution for Preview and Playback and with 8 TB Survellance Hard Disk
Supply, Installation, testing and commissioning of Intel Core i5 12C Processor 25M Cache, up to 4.90 GHz
138 E-138 / 16GB DDR5 / 512 SSD / Win 10 Pro Operating System / No Monitor / DVD RW / 3 Yrs NBD / PS 500W/ 1.00 Nos. 75,900.00
NVIDIA T600 4 GB GDDR6 Workstation Graphics Card including 4 mDP to DP adapters
SITC of 32 Inch 500 NTS Brightness professional Display with Direct-Type LED, Viewing Angle :
Degree Verti, 178 Degree Hor. Operation 27x7, Native Resolution 3840 x 2160 (16:9) - UHD, 4 x USB (2 x
2.0, 1 x 2.0 internal, 1 x Type C), 0-40°C, ≤0.5 W, HTML 5 Browser Opera(4.9), Yes(internal) IEEE
802.11 a/b/g/n Dual
WiFi certificated, BIS, YES CLASS A 3dB margin. (Including Five year free maintenance with
Networking Enclosures & Accessories Supply, Installation, Testing & Com mission ingot 24U Wall mount
closed rack with front glass door, fan tray on top, perforated rear doors, keyboard tray with shelf. Casters &
2 nos vertical power strip with std etc as required.
Supply, Installation, Testing And Commissioning of Layer 2 Managed Gigabit POE switch with 24 #
10/100/1000BaseT ports and 2 # Gigabit Combo ports(RJ45/SFP), 2 # Gigabit SFP Port.
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction
143 E-143 Supply and laying of Cat-6 STP LSZH UV outdoor cable in PVC conduit with termination as per TIA 200.00 Meter 113.00
SR. No. Item No. Description of Work Unit Rate Amount
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured / metallic/white front plate , modules erected with necessary
144 E-144 connections as per site situation directed by Engineer In charge. 1.00 Nos. 159.00
(4) TV Co-axial Socket outlet
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-
boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The charger
having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load
145 E-145 power factor with battery, over/under voltage output with over load & short circuit protection equipment. 1 Nos. 1,28,815.00
The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted
batteries stand, 10% Overload capacity for momentary load.
(D) 5 KVA with 1Hr Backup
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete.
For 4.5 Kg Capacity, including maintaining/ renewal validity of all Co2 fire extinguisers up to the
completion of O&M period
Supplying rubber matting of following thickness as per IS : 15652/IEC61111
Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be
148 E-148 erected as per IS. 2.00 Nos. 69.00
Providing printed instruction chart both in English and Gujarati and duly framed with front glasses, for
149 E-149 treatment of person suffering from Electric shock 2.00 Nos. 129.00
Providing & laying. Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )
Anti Rodent type with necessary connecting accessories of same material at required depth for laying of
150 E-150 cable. below ground / road surface for enclosing cable and backfilling the same to make ground as per 400.00 Meter 62.00
SR. No. Item No. Description of Work Unit Rate Amount
Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @
an ambient temp of 45˚ C. The outlet temp. of the water should drop by 15˚C within a hour, The water
153 E-153 cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank 1.00 Nos. 55,340.00
surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection.
The body of water cooler will be made from Stainless Steel.
Supplying and erecting water filter cum purifier with ultra violate technology. (Aquaguard / waterdoc model
or equivalent symphony/ crystal/videocon model)
S.I.T.C. of single phase submersible pump set suitable for 100 mm size or more dia bore well having motor
capacity and discharge as under with necessary panel box. Lifting and Lowering taken extra.
(c) Motor rating 2 HP (17 stage) pump having capacity of 106 LPM at 40 mtr head suitable for 32 mm dia.
Supplying & erecting approved make Automatic liquid level controller 6A. with sensor testing as per
156 E-156 instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper 1.00 Nos. 2,332.00
conductor from pump to upper and lower tank.
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Submersible copper cable
157 E-157 approved make of following Size. 20.00 Meter 103.00
(B) 3 Core x 2.5 Sq. mm.
AIR-CONDITIONERS
Providing and erecting approved make split air-conditioning unit consisting of copper condensing unit with
fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected
evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper
tubing,drain PVC pipes suitable for ( cost includes powder coated Stand, Eco Friendly green gas charging,
15A plug top & Remote Control) with necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99) Premium Category
(b) for 1.5 ton capacity
Providing and erecting approved make split air-conditioning unit consisting of copper condensing unit with
fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected
evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper
159 E-159 tubing,drain PVC pipes suitable for ( cost includes powder coated Stand, Eco Friendly green gas charging, 4.00 Nos. 58,706.00
15A plug top & Remote Control) with necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99) Premium Category
(c) for 1.7 to 2.0 ton capacity
SR. No. Item No. Description of Work Unit Rate Amount
Providing and erecting approved make Cassette type split air-conditioning unit consisting of condensing
unit with fan motor, hermetically sealed scroll/rotary compressor with accessories etc. duly connected
separately erected evaporating unit and blower motor with its accessories by Eco friendly Green gas
charging & Internal copper wiring & Remote control ( 3 star and above of current year) with necessary core
(E) for 4 ton capacity- 1/3Phase
Supplying & installing MS standard type stand mounting for outdoor unit of Split A.C. upto 4 TR capacity
erected with necessary hardware materials as directed.
Supplying and erecting insulated pair of soft copper tubing open or concealed including power and control
cable,necessary PVC drain pipes for Cassette / Split AC machine up to 4 TR capacity
Liason / Follow UP with Supply Co.
Filling the necessary application to supply co. following up and getting the supply filling the necessary test
report to the supply co. inclusive. All official fees including security deposits will be paid by the client and
out of pocket expenses shall be of contractor.
Total Cost of Electrical, ELV & Heating Ventilation & Air - Conditioning Work
Ahmedabad Municipal Corporation
Construction of Swimming Pool at T.P.-128, F.P.-493 in Vatva Ward, South Zone, Ahmedabad.
BOQ - Filtration Work
Item Description Unit Rate Amount
Supply, installation, testing and commissioning of Short coupled, CED coated, Centrifugal
Horizontal Back-pull-out industrial type pump set with cast iron body, bronze impeller, carbon-
ceramic mechanical seal, stainless steel shaft, with 7.5kW, IE3, TEFC 1450 RPM prime mover
1 suitable for 415V, 50Hz, 3 phase AC power supply, with base-frame, 125 x 250mm stainless 4.00 Nos. 4,25,000.00
steel escentric pre-filter with stainless steel basket, 100mm NRV, 250mm ball type foot valve,
100mm isolation valve and pressure gauge in accordance with technical specification. (2 working
+ 2 standby = 50% standby). Design flow rate 159m3/hr @ 12-14 meter head for each pumpset
Supply, installation, testing and commissioning of 2000MM dia and 3000MM long Horizontal
Bobbin Wound FRP filters 1200mm bed depth. The inner distribution system and under bed
draw off system shall be of hub and lateral type. The filter shall be equipped with man-hole,
2 manometer, air drain, water/sand draining hole, inlet/outlet with flanges and minimum working 2.00 Nos. 14,00,000.00
pressure of 2.5 Kg/ cm2 with 160mm frontal piping with 5 (five) butterfly valves, manometer,
pipe supports and media complete in accordance to the manufacturers specifications. Design flow
159m3/hr each filter. Max permissible velocity 30 M3/ M2/HR
(B) Disinfection System
Supply, installation, testing and commissioning of direct cylinder mounted type gaseous
chlorinator, with vacuum regulator, integrated safety valve, filter and pressure gauge, flow meter,
ejector, non-return valve, PE tubing, ammonia bottle and spanner. Capacity 0-4 kg/hr with
Booster pump, piping, control valves and pressure gauge.
4 Supply of 100 kg filled chlorine gas cylinder in accordance to the specifications 4.00 Nos. 26,945.00
5 Supply of Safety test kit for chlorine gas cylinder in accordance to the specifications 1.00 Nos. 35,000.00
Supply of Double state self contained open circuit compressed air breathing apparatus in
Accordance to the specifications
Item Description Unit Rate Amount
(C) Pool Basin Equipments
7 Regulable floor inlets. 57.00 Nos. 1,000.00
8 Vaccum / Suction inlets 5.00 Nos. 1,000.00
9 Stainless Steel Main drain grills 500 x 500mm. 2.00 Nos. 45,000.00
10 Stainless Steel Main drain grills 300 x 300mm. 1.00 Nos. 24,000.00
(D) Maintenance & Cleaning Equipments
Self Priming Pumpset with built-in pre filter with transparent lid, carbon-ceramic mechanical
seal, stainless steel shaft, rated speed 3000 RPM 440V, 50Hz. Rated flow 30m3/hr
90cm Stainless Steel vacuum head with hooks for attaching towing ropes and 60 mtrs towing
13 Self floating hose 30 mtrs, 50mm dia 1.00 Nos. 15,000.00
14 Telescopic pole 9 mtrs 1.00 Nos. 11,000.00
15 Aluminum reinforced Deep Net, clip type 1.00 Nos. 3,500.00
16 90cm aluminum reinforced curved brush with plastic bristles, clip type 1.00 Nos. 5,500.00
17 450mm Aluminum reinforced curved brush with SS bristles, clip type 1.00 Nos. 4,500.00
18 Providing hand held electronic ORP tester. 1.00 Nos. 15,000.00
19 Providing hand held electronic pH tester. 1.00 Nos. 5,000.00
20 Providing reagent based Residual/Free Chlorine & pH test kit. 1.00 Nos. 2,500.00
(E) Stainless Steel Ladders
Supply, installation, testing and commissioning of Stainless Steel 2 treads ladder with anti skid
Supply, installation, testing and commissioning of Stainless Steel 3 treads ladder with anti skid
Supply, installation, testing and commissioning of Stainless Steel 4 treads ladder with anti skid
Supply, installation, testing and commissioning of Stainless Steel 5 treads ladder with anti skid
(F) Overflow Grating
25 Providing & fixing pool overflow modular grating 345 x 23mm as per specifications 100.00 Rmt 1,640.00
26 Providing & fixing pool overflow modular grating 240 x 23mm as per specifications 41.00 Rmt 1,475.00
27 Gating corner piece 90 deg 345 x 345 4.00 Nos. 3,500.00
Item Description Unit Rate Amount
28 Gating corner piece 90 deg 240 x 240 4.00 Nos. 2,500.00
Supply, installation, joining and testing PVC pipe confirming to IS : 4985 class IV 10Kg/cm2
including all fittings such as such as bends, elbows, reducers, tees, union, coupler, tail piece
flange etc. Cost shall be inclusive for providing supports as per specifications and making good.
Pipes shall be connected to pumps, equipments, valves etc through tail piece flange.
Providing & Fixing sluice Valve of 12" with extended spindle accordance with technical
specifications.
Providing & Fixing sluice Valve of 4" with extended spindle accordance with technical
specifications.
Providing & Fixing 90mm dia PVC double union ball valve to the suction sweeper line in plant
Supply, installation, joining and testing 10" dia Cast Iron D/F pipe as per pump manufacturers
recommendations for pump suction confirming to IS : 1538 including fittings.
(H) Control Panel
Design, manufacture, supply, installation, testing and commissioning of integrated, cubical type
34 dead front, extensional, 16 SWG CRCA sheet steel control panel to the foundation. The control 1.00 Nos. 2,50,000.00
panel should be suitable for 440 volts, 50 Hz, 4 wire supply.
(I) Competition Equipment
35 Providing & fixing S.S. anchors for Anti-wave racing lanes in pool etc.complete. 18.00 Nos. 3,500.00
Providing & handing over of 50 mtrs. anti-wave racing lanes in red, white and blue coloured
floats with Stainless Steel cable, fasteners and hooks.
Providing SS reels/ roller for lane storage. Each roller should be capable to accommodate
(three) 50 meters racing lanes
Item Description Unit Rate Amount
Providing and handing over of 450mm starting platform with a slip resistant top surface, a slip-
38 resistant step and anchors. Platform assembly can be removed by unscrewing fasteners as and 10.00 Nos. 1,25,000.00
when required. The same will be in accordance to the specifications.
(J) Operation & Maintenance
OPERATION & MAINTAINENCE - After commissioning of the filtration plant, the contractor
will run the plant for ONE YEAR. Electricity, water and chlorine gas shall be provided by the
AMC. The work includes operation of filter plant on daily basis and ensuring clean and healthy
water at all times. Maintaining chemical control of water as per standard quality levels, operating
suction sweeper for floor cleaning etc. The client reserves right to renew the said contract for a
further period on a mutual agreeable time and cost.
(K) Office Furniture for Operator
40 Wooden office Table of size 1200mm length x 600mm width 1.00 Nos. 5,000.00
41 Steel Office Chair 3.00 Nos. 3,000.00
42 Steel Cupboard (4 feet H x 3 feet W x 1 feet 4 inch D) 1.00 Nos. 16,000.00
Total Amount of Filtration Work
Total Amount of Filtration Work
Ahmedabad Municipal Corporation
Proposed Construction of Swimming Pool at T.P.-128, F.P.-493 in Vatva Ward, South Zone, Ahmedabad.
BOQ - Self Supporting Roofing Work
Item No. Item Description Unit Rate Amount
Providing, Fixing, Installation of Proflex - Self Supported Galvalum Roofing of Proflex from
M&B Engineering Ltd or Equivalent with proper overlapping and seaming between different
sheets without making holes or preventing the overturning the roof by wind addition made up
from superior quality, structural grade steel. Base metal width 914 mm with tolerance of +/-
mm, Steel Grade : Grade D Regular Modified Polyster Imported Color Coated Galvalume
Steel having Profiled width of 625 mm +/-10 mm. Design, supply, & fabrication of self
1 supported single span arch roof fabricated from mechanically seamed manufactured by
American Hydraulic Machines to profiles of Imported Galvalume Cold Rolled Structural Steel
coils as per standard ASTM A792, Steel Sheet, Aluminum-Zinc Alloy Coated by Hot-Dip
Process. The work should be carried out by specilialize and approved agency only. The rate of
item is including fitting as per standerd specification. The vendor shall give windload End
Reaction before start of the work and the vendor shall be entirely responsible for the damage
of the same during transport, installation and even after installation upto 1 years.
Thickness 1.60 mm BMT, 1.65 mm APT with tolerance of +/- 0.02 mm, Coil Width 912 mm
tolerance of +/- 0.04 mm, for upto 31 Mtr Span Length 63 Mtr
Thickness 1.00 mm BMT, 1.05 mm APT with tolerance of +/- 0.02 mm, Coil Width 912 mm
tolerance of +/- 0.04 mm, for upto Span: 16 Mtr and Length 20 Mtr
Providing and fixing of hangers/clamps as per requirement for laying of cables and hanging Piece
of bulbs from Self Supported Proflex Systems Roofing. (Nos)
Total Amount of Self Supporting Roofing Work
Total Amount of Self Supporting Roofing Work
Ahmedabad Municipal Corporation
Proposed Construction of Swimming Pool at T.P.-128, F.P.-493 in Vatva Ward, South Zone, Ahmedabad.
BOQ - Fire Fighting Work
Sr.No. Item Description Unit Rate Amount
Supplying, installing, testing and commissioning of electrical operated end suction, back pull out type,CI closed casing, SS shaft & Bronze
impeller, mechanical seal, booster pump of capacity 900 LPM and gainst head of 35m with a pressure of 4.5 kg/cm2 at the nearest & top
most hydrant with Booster starter. M.S. frame & clamps as necessary for fixing the pumps on the top of slab as per site condition and
instructions of site enGIneer in charge .
Supplying, installing, testing and commissioning of Control Panel for Booster Pump to start the booster pump with cabling from
Booster Pump to Panel at Terrace Level.
3.0 3.Core x 10 Sq.mm Copper armoured cable for pump to panel 30.00 Meter 907.40
4.0 Providing, fixing, testing and commissioning of Pressure Gauge with Ball Valve 2.00 Nos. 3,200.00
Providing and fixing, testing and commissioning of C.I.Butterfly valve PN16 with Flanges. conforming to I.S:13095, Nut bolts, Gaskets
completed as required.
Providing, fixing, testing and commissioning of C.I. Dual plate type Non-Return Valve class PN 16 rating with fittings, flanges, nutbolts,
washers, gaskets etc.of sizes:
7.0 Providing and fixing, testing and commissioning of Y Type Strainer.
Providing, fixing, testing and commissioning of Above Ground MS C Class Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS:
3589 (upto 200 mm dia. And above) including cutting, screwing, welding etc. and providing all fittings like flanges, bends, tees, elbows,
reducers, clamps, hangers etc. with painting of one coat of primer and 2 or more coats of synthetic enamel paint of approved make / shade
complete as per specification.
8.2 80mm dia. 6.00 Meter 1,943.00
8.3 50mm dia. 6.00 Meter 1,237.00
8.4 25mm dia. 6.00 Meter 595.00
Providing, fixing, testing and commissioning of Under Ground MS C Class Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS:
9.0 3589 (upto 200 mm dia. And above) with IWL/pypecoat, 4mm thickness wrapping and coating and providing all fittings like flanges, tees,
elbow, fasteners with all required.
Fire Fighting Equipement
Providing, fixing, testing and commissioning of SS Single Headed Oblique Pattern Hydrant Landing Valves as per IS: 5290 with 80 mm
dia flanged inlet & 63 mm dia female outlet complete with cap and chain etc.
Providing, fixing, testing and commissioning of SS Branch Pipe with nozzle of 25 mm nominal bore outlet suitable to fit with standard
instanteneous type 63 mm dia coupling. As per IS:903
Providing, fixing, testing and commissioning of 63 mm dia 15m long RRL Hose Pipe with 63 mm dia.Type A Male and female Stainless
Steel couplings duly binded with GI wire, rivets etc. conforming to IS 636 as required.
Providing, fixing, testing and commissioning of weather proof standard fire Hose Cabinet wall mounting type 18 Guage. (750 x 600 x 250)
having Double Opening with M.S. fabricated stand, necessary locking arrangement by allan key.
Sr.No. Item Description Unit Rate Amount
Providing, fixing, testing and commissioning of Wall mounting swing type first aid Fire Hose Reel with drum, hanGIng bracket, 30 M x
25 mm dia high pressure hose reel tubing as per IS:884 with shut nozzle and ball valve and all required accessories.
15.0 Providing, fixing, testing and commissioning of CI Two way Fire Brigade Inlet for system filling from Fire Brigade Tender. 2.00 Nos. 12,480.00
Fire Extinguisher.
Providing & fixing of 6 Kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge,
16.0 Controllable discharge mechanism Class A Rating 3A & Class B rating 21B as per IS 15683 ISI MARK (ABC Dry Chemical Powder - 20.00 Nos. 2,118.00
Providing & fixing of CO2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 Gas as per IS 15222 with controll discharge
17.0 mechanis, fitted with Hose & Horn applicable on Class B fire rating 21B confirms to IS 15683 bearing ISI mark. Co2 cylinder as per IS 20.00 Nos. 4,810.00
Providing & fixing of Mechanical Foam 9 Ltrs. Stored Pressure Type Controllable discharge mechanism applicable on Class A & B Fire
Rating 2A & 21 B
Manual Fire Alram System. 0.00
19.0 Providing, fixing, testing and commissioning of Manual Call Point. 4.00 Nos. 518.00
20.0 Providing, fixing, testing and commissioning of Hooter 4.00 Nos. 658.00
Providing, fixing, testing and commissioning of Fire Alarm Panel
22.0 Providing, fixing, testing and commissioning of 2 Core X 1.5 Sqmm Flexible Cable with PVC Conduit. 250.00 Meter 160.00
On - Off Pump Trigger System.
23.0 Providing, fixing, testing and commissioning of On -Off Switch. 6.00 Nos. 890.00
24.0 Providing, fixing, testing and commissioning of 3 Core X 1.5 Sqmm flexible Cable with PVC Condiut. 500.00 Meter 210.00
Providing, fixing, testing and commissioning of 25 mm dia Air Release Valve and Ball Valve assembly on top of each riser for Air release
Providing, fixing, testing and commissioning of below Auto Glow Signages.
26.0 Emergency Exit 4” X 12” 15.00 Nos. 450.00
27.0 Fire Hydrant 4” X 12” 2.00 Nos. 450.00
28.0 Fire Hose Reel.4” X 12” 2.00 Nos. 450.00
29.0 " ABC" Extinguisher 8"x 4" 20.00 Nos. 550.00
30.0 "CO2 " Extinguisher 8"X 4" 20.00 Nos. 550.00
32.0 Supply, Installation of Steel Structure Support. 500.00 Kg 145.00
Sr.No. Item Description Unit Rate Amount
Fire Rated Steel Doors with steel frames as per BS:476 (20&22), IS 3614 (Part-2) for stability and integrity. pressed Galvanized steel
conforming to IS 277 with the following specification. recommended fire door shell have doors tested at CBRI for maximum rating of
Door frame shall be Single rebate profile of size 105 x 57 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet.
Frames shall be mitered and field assembled with self-tabs. All provision should be mortised, drilled and tapped for receiving appropriate
hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor
fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry
necessary for fire doors on the clear masonry opening.
33.0 Door leaf shall be 46mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick 3.00 Sqm 33,500.00
galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The
infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided
with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair
of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be
provided as per manufacturer's recommendation with a beading and screws from inside. The glass should be 6mm clear borosilicate fire
rated glass of relevant rating of the door.
All doors and frames shall be finished with polyurethane aliphatic grade paint of approved color. The door leaf and frame shall have passed
minimum 250 hours of salt spray test. Rate should include supply and installation of door and hardware set as mentioned in the door.
Hardware Fittings Make :- Doorma , Geze , Hafales
APPROVAL FIRE SYSTEM FROM LOCAL FIRE AUTHORITY
34.0 Getting of Fire Fighting System Approval from local fire authority with all other charges and documentations for getting No Objection 1.00 Job 1,80,000.00
Non Comprehensive Quarterly Maintenance service charge for Fire Fighting System including servicing of fire fighting system with
cleaning ,oiling and Greasing of fire fighting equipment's, give live demonstrations And performing live mock drill once in a year of the
system after completion of DLP.
Quarterly servicing and maintenance will be done for Fire Fighting systems.
a) To check & Maintain the Fire Fighting System as per Installation done.
b) Checking of Butterfly valve , NRV, Ball valve for smooth operation.
c) Checking of Fire Brigade Inlet.
d) Visually check of Sprinklers for Leakage.
e) Fire Extinguisher to be checked physically.
f) Testing of Main Pump, Sprinkler Pump & Jockey Pump, Fire Panel.
g) Physical checking of each Fire fighting Equipment's. (Like Hydrant Valve , Hose Reel,Hose Box , Hose pipe And Branch Pipe etc..)
h) Checking of Pump room in active working condition.
I) Refilling of Fire Extinguisher will be in contractor scope as per client requirements.
J) Including Charges for fire New / Renewal NOC, for Fire Fighting System.
K) Videography , Photo graphy , numburing & Pendrive etc. as per norms for New / Renewal NOC.
35.1 First Year 4.00 Job 36,158.40
35.2 Second Year 4.00 Job 45,198.00
35.3 Third Year 4.00 Job 54,237.60
Total Amount for Fire Fighting Work
Total Amount for Fire Fighting Work
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Document
Document
Volume - III Financial Bid (1).pdf
00. VATVA - SWP - TENDER FINAL.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .