Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.3 L+₹67,000 (5.30%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.4 L+₹72,051 (5.70%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L3 | Rejected-Finance L3 |
Tender Value
₹15.1 L
EMD Value
₹30,200
Closing Date
10 May 2024, 11:00 amClosed
Asst GM EE
AAI Calicut International Airport
Replacement of Outlived Air conditioners and Water Coolers installed at Calicut International Airport - Phase I
2024_AAI_193617_1
AAI/CL/EE/226/NIT-02/24-25
Open Tender
Electrical Works
Works
90 days
AAI Calicut Airport
please refer tender document
12 documents required · 12 mandatory
₹1,120
₹30,200
23 Oct 2024
18 Apr 2024
13 May 2024
19 Apr 2024
10 May 2024
19 Apr 2024
19 Apr 2024 - 25 Apr 2024
Amount
Supply, Installation , Testing and Commissioning of 2 TR Split type 5 star rated energy efficient,(minimum EER 4.50) invertor type, single phase, wall mounting type split Air conditioner unit, consisting of indoor unit with copper coil , out door condensing Unit with copper coil unit, cordless remote control, non CFC refrigerant gas, standard length of refrigerant pipe, drain pipe, power cable etc. and suitable for operation on 230 V, 50 HZ, single phase AC supply etc. as per OEM standard and complete as required as per technical specifications comprising the following including first charge of refrigerator , complete as required. a) Suitable Insulated Copper pipe for liquid or as per OEM specification for length upto 5 Metre b) Suitable Insulated Copper pipe for suction or as per OEM specification of length upto 5 Metre c) Suitable FR insulated , PVC sheathed Unarmoured multi strand Copper cable or as per OEM specification for length upto 5 metre. d) Supply & Fixing of Heavy Duty rigid PVC pipe / PVC trunking suitable size for covering in the liquid line , suction line and multistrand cable or as per OEM Specification for length upto 5 Metre. e) Voltage Stabilizer of approved make suitable for 2TR AC f) Necessary Supports for out door Unit and Indoor unit as required at site.
Supply of 1.5 TR Split type 5 star rated energy efficient,( minimum EER 4.50) invertor type, single phase, wall mounting type split Air conditioner unit, consisting of indoor unit with copper coil , out door condensing Unit with copper coil unit, cordless remote control, non CFC refrigerant gas, standard length of refrigerant pipe, drain pipe, power cable etc. and suitable for operation on 230 V, 50 HZ, single phase AC supply etc. as per OEM standard and complete as required as per technical specifications comprising the following including first charge of refrigerator , complete as required. a) Suitable Insulated Copper pipe for liquid or as per OEM specification for length upto 5 Metre b) Suitable Insulated Copper pipe for suction or as per OEM specification of length upto 5 Metre c) Suitable FR insulated , PVC sheathed Unarmoured multi strand Copper cable or as per OEM specification for length upto 5 metre. d) Supply & Fixing of Heavy Duty rigid PVC pipe / PVC trunking suitable size for covering in the liquid line , suction line and multistrand cable or as per OEM Specification for length upto 5 Metre. e)Voltage Stabilizer of approved make suitable for 1.5 TR AC f) Necessary Supports for out door Unit and Indoor unit as required at site.
Supply of 4 TR Cassette type 5 Star energy efficient,split Air conditioner unit, consisting of indoor unit with copper coil , out door condensing Unit with copper coil unit, cordless remote control, non CFC refrigerant gas, standard length of refrigerant pipe, drain pipe, power cable etc as per OEM standard and complete as required as per technical specifications comprising the following including first charge of refrigerator , complete as required. a) Suitable Insulated Copper pipe for liquid or as per OEM specification for length upto 5 Metre b) Suitable Insulated Copper pipe for suction or as per OEM specification of length upto 5 Metre c) Suitable FR insulated , PVC sheathed Unarmoured multi strand Copper cable or as per OEM specification for length upto 5 metre. d) Supply & Fixing of Heavy Duty rigid PVC pipe / PVC trunking suitable size for covering in the liquid line , suction line and multistrand cable or as per OEM Specification for length upto 5 Metre. f) Necessary Supports for out door Unit and Indoor unit as required at site.
Supply and fixing of following for interconnection between evaporator unit and condensor unit mentioned in Item No. 1, 2 & 3 ( if extra additional length is required other than standard 5 Metre mentioned in the BOQ dor Item No.1,2&3) Suitable Insulated Copper pipe for liquid line or as per OEM specification for the item 1,2 & 3
Supply and fixing of following for interconnection between evaporator unit and condensor unit mentioned in Item No. 1, 2 & 3 ( if extra additional length is required other than standard 5 Metre mentioned in the BOQ dor Item No.1,2&3) Suitable Insulated Copper pipe for Suction line or as per OEM specification for the item 1,2 & 3
Supply and fixing of following for interconnection between evaporator unit and condensor unit mentioned in Item No. 1, 2 & 3 ( if extra additional length is required other than standard 5 Metre mentioned in the BOQ dor Item No.1,2&3) Suitable FR insulated , PVC sheathed unarmoured multi strand copper cable or as per OEM specification for Item 1,2 & 3
Supply and fixing of following for interconnection between evaporator unit and condensor unit mentioned in Item No. 1, 2 & 3 ( if extra additional length is required other than standard 5 Metre mentioned in the BOQ dor Item No.1,2&3) Supply and Fixing of Heavy duty Rigid PVC Pipe/PVC trunking of suitable size for covering the refrigerator pipes , drain line , copper cable etc as required.
Supply & Fixing of 32 mm Dia Medium class PVC Pipe as drain pipe for the AC Units installed as per Item 1,2 & 3
SITC of Hot, Cold & Normal water dispensor with stand alone unit water purification system complete as per the sopecifications as required. The unit shall have a minimum tank capacity of (a) 30 Litres Normal Water (b) 40 Litres Cold Water (c) 4 Litres Hot Water, minimum flow rate of 250 Litres/hr with SS body and shall be suitable to connect to existing water outlet system at Various locations including all required connections. The compressor / heater / filter unit shall be suitable to work with 230V, 50 Hz AC Power Supply.
jaydeep agency corporation
VOLKS ENERGIE PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .