Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹20.6 L Quoted ₹21.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.7 L+₹93,943 (4.31%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹22.7 L+₹93,943 (4.31%) | L2 | Rejected-Finance L2 |
| 3 | L3₹23.6 L+₹1.8 L (8.46%)Rejected-Finance | ₹23.6 L+₹1.8 L (8.46%) | L3 | Rejected-Finance L3 |
| 4 | L3₹24.5 L+₹2.7 L (12.6%)Rejected-Finance | ₹24.5 L+₹2.7 L (12.6%) | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
1 Sept 2020, 6:00 pmClosed
GE (AF) JAMNAGAR N0.1
Garrsion Engineer (AF)No.1 Military Engineer Services Air Force Station Jamnagar 361003
REPAIR/MAINTENANCE OF EXTERNAL ELECTRIFICATION AND CONNECTED ITEMS AT AFS SAMANA UNDER GE (AF) JAMNAGAR NO.1
2020_MES_362028_2
8745/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
SAMANA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR NO.1
₹48,000
26 Sept 2020
18 Aug 2020
2 Sept 2020
18 Aug 2020
1 Sept 2020
18 Aug 2020
Amount
Taking out LT underground cable from trenches etc, aluminium conductor of size 10 sqmm 2 / 4 core complete all as specified and directed by Engr-in-Charge.
Taking out LT underground cable from trenches etc, aluminium conductor of size 25 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Taking out LT underground cable from trenches etc, aluminium conductor of size 16 sqmm 2 / 4 core complete all as specified and directed by Engr-in-Charge.
Taking out LT underground cable from trenches etc, aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Taking out LT underground cable from trenches etc, aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Taking out LT underground cable from trenches etc, aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Taking out LT underground cable from trenches etc, aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Taking out LT underground cable from trenches etc, aluminium conductor of size 185 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Taking out HT underground cable from trenches etc, aluminium conductor of size 120 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Note for item No 01 to 09:- earth work, removal of cable cover will be measured and paid seprately under respective items of this schedule.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 35 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 120 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 185 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel or wire heavy duty,HT underground cable(earthened grade) with aluminium conductor 11000 voltgrade of size 120Sqmm 3 core laid in trenches/duct passing through pipe/duct or fixed on pole and connecting and testing etc complete all as specified and directed by Engr-in-Charge.
Note for item No 10 to 19:- (i) Earthwork sand cushioning cable cover will be measured and paid seprately under respective items of this schedule. (ii) Straight through joint will be measured and paid seprately.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2 core, 16 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 4 core, 16 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 50 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70 to 95 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 185 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 300 to 400 Sqmm all as specified and as directed by Engineer-In-Charge.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soft / loose soil complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance exc 50 m but n.exc 100 m and depositing where directed at a level n.exc 1.5m above the starting point.
Taking out old PCC cable cover of any type / any size from trenches acomplete all as specified and directed by Engr-in-Charge.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. (Note: for measurement purpose any punned thickness of sand will be considered.)
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed by Engr-in-Charge.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class HV , Type I , flat size 300 mm X 180 mm X 40 mm in trenches as protection of HT UG cable complete all as specified and directed by Engr-in-Charge.
Laying only PCC cable cover for LT UG cable, of any description retrieved from item No.30, all as specified and directed by Engr-in-Charge.
Supply, fix in repair digital programmable Time Switch 24 HOURS of supply voltage 220-240 Volts AC, 50/60 HZ. Make :- Havells DHTDD15016 or equivalent of make Siemens / legrand
Supply and fix in repair contactor 170 amps for 200 KVA voltage Stabilizer of input voltage 340-480 Volts AC 3 Phase and output voltage 400-430 Volts AC 3 Phase. Make: Siemens Catpat No.3TF52 or equivalent of ABB/L&T.
S&F in repair 07 Watt LED underwater / Fountain Light water proof enclosure along with its DMX controller, colored effects, fixed in position & connecting complete all as specified and directed by Engr-in-Charge. Make:- CG Cat NO LUWH2-07-RGB or equivalent of make mentione Appx B
S&F in repair 5 Watt LED spike Light water proof enclosure, off white color, fixed in position & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair sealed maintenance free battery, 12 volt & 75 AH, suitable for solar type street light fitting.
Supply & fix in repair LED 18 Watt luminary assembly suitable for solar type street light fitting & connecting complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair complete circuit board (PCB) suitable for 11/18 Watt LED solar type street light fitting & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC battery box suitable for 12 volt & 75 AH battery of solar type street light fitting.
Supply & fix in repair brass lugs for lead acid battery for solar type street light fitting.
M&L for preparation of old painted surface of steel tubular pole 9 meter long & applying one coat of aluminium paint on exposed surface, painting of band in alternate strip of 0.25 meter each with yellow & black synthetic enamel paint up to 1.5 meter height above PCC coping, including writing pole No with black synthetic paint complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MCCB 40 Amp, four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MCCB 63 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 100 Amp, Four Pole, breaking capacity 16 / 18 KA, 415 V - 50 Hz, with adjustable thermal and magnetic setting fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 160 Amp, Four Pole, breaking capacity 16 / 18 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 200 Amp, Four Pole, breaking capacity 35 /36 KA, 415 V - 50 Hz,with adjustable thermal and magnetic setting fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 400 Amp, Four Pole, breaking capacity 50 KA, 415 V - 50 Hz,with adjustable thermal and magnetic setting fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
S&F in repair LED Street Light / building security light fitting 15 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing pipe bracket on pole, and connecting with electric connection including taking down old light fitting complete all as specified and directed by Engr-in-Charge.
S&F LED Street Light / building security light fitting 25 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing pipe bracket on pole, and connecting with electric connection including taking down old light fitting complete all as specified and directed by Engr-in-Charge.
S&F LED Street Light / building security light fitting 45 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing pipe bracket on pole, and connecting with electric connection including taking down old light fitting complete all as specified and directed by Engr-in-Charge.
S&F LED Street Light / building security light fitting 70-72 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing pipe bracket on pole, and connecting with electric connection including taking down old light fitting complete all as specified and directed by Engr-in-Charge.
S & F in repair LED Flood Light fitting 200 watt, High Efficiency IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting including taking down old light fitting of any description complete all as directed by Eng-in-charge.
Note for Item No 51,52,53,54 & 55 :- (i) The Defect liability of LED light fitting provided under this contract shall 3(three) year from the certified date of completion of work.
(ii) Contractor shall furnish guarantee bond on non judicial stamp and submit it to GE for guarantee of LED light fitting provided under this contract.
(iii) Contractor shall submit security deposit @ 5% amount of these items (in addition to performance security) calculated as per quantity actually executed at site. security deposit amount shall be retained out of the contractor’s bill as security deposit for guarantee period of 03 year which shall be refunded to him after expiry of guarantee period satisfactorily. Alternatively, the contractor may give a separate interest bearing security deposit or Bank Guarantee Bond to GE valid for 03 years for this amount.
Supply & fix in repairs round, 2 core cable, PVC insulated and PVC sheathed, copper conductor of size 2.5 Sqmm, for electric connection from feeder / looping box / street light over head line to street light fitting.
S&F in repair Sheet moulding compound (SMC) junction box of size 280 mm x 170 mm x 130mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps C type, fixed on pole with mild steel clamps, nuts and bolts complete all as specified and directed by Engr-in-Charge.
S&F in repair 70 watt MH lamp, 2 pin , 230 V, 50 HZ suitable for Landscape luminarie.
S&F in repair 150 watt MH lamp, 2 pin , 230 V, 50 HZ suitable for Landscape luminarie.
S&F in repair 18 watt CFL , 2 pin/4 pin , 230 V, 50 HZ suitable for garden bollard light.
Supply and fix in repair ballast vacuum impregnated consisting of silicon steel laminated super enamelled copper wire core suitable for 70 watt MH/HPSV 220/ 240 volts 50 Hz lamp &connecting complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair ballast vacuum impregnated consisting of silicon steel laminated super enamelled copper wire core suitable for 150 watt MH/HPSV 220/ 240 volts 50 Hz lamp &connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair electromagnetic ballast, for 18 watt CFL, 230 V, 50 HZ .
S&F in repair electronic drivers suitable for 25 watt LED street light fitting, fixed in position & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair electronic drivers suitable for 45 watt LED street light fitting, fixed in position & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair electronic drivers suitable for 70 watt LED street light fitting, fixed in position & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair electronic drivers suitable for 120 watt LED street light fitting, fixed in position & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair Surge protection devices of rating 5KV, compatible with industrial & outdoor LED fixtures with rated power up to 75 W fitting, fixed in position & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair Surge protection devices of rating 5KV, compatible with industrial & outdoor LED fixtures with rated power 75 W to 150 W fitting, fixed in position & connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair HT 11 KVA drop out fuse element for transformer protection of rating 10/20 amps
S&F in repair Automatic battery charger for DG set from commercial supply of input AC 170-270 V and output 12 V DC.
S&F in repair DG power contactor 4 pole of Auxiliary contact NO + NC , of capacity 80 Amps. Make:- Schneider Electric / ABB / C&S / Siemens
S&F in repair phase failure relay of auxiliary supply 415 V AC, 50 Hz. Make:- Minilec VSP D2 , Sr. No 2U1078 or equivalent of make approved by the GE
M/s SK Traders
Sagathiya Builders
ambika electric co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .