Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹28.9 L Quoted ₹29.0 L | L1 | Accepted-AOC Being 1st lowest |
| 2 | L2₹33.4 L+₹4.4 L (15.2%)Rejected-Finance | ₹33.4 L+₹4.4 L (15.2%) | L2 | Rejected-Finance Being 2nd lowest |
| 3 | L3₹41.1 L+₹12.1 L (41.8%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹41.1 L+₹12.1 L (41.8%) | L3 | Rejected-Finance Being 3rd lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not fulfilling the NIT criteria |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
20 Jan 2024, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
SPL REPAIR OF DG SET 400 KVA CAPACITY, EXTERNAL PLASTER AND WATER PROOFING TREATMENT OF 14 LEADING QTR, SUPPLY AND FIX CEILING FANS, TABLE FANS, EXHAUST FANS, GEYSERS AND PROVN OF SIGN BOARD AND ROAD SIDE FURNITURE AT NHO, DEHRADUN
2023_MES_634298_1
GE /CLT / of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat a(i) and b(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹94,000
Yes
15 Mar 2024
23 Dec 2023
27 Jan 2024
23 Dec 2023
20 Jan 2024
6 Jan 2024
Amount
Taking down cement plaster incl grit finish plaster of any description any thickness on brick work , stone masonry or concrete surfaces walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L 15mm thick rendering cement mortar (1:4) mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. (WPC shall be paid seperately)
M&L 5mm thick rendering in ceiling of cement mortar (1:3) on fair faces of brick work or concrete surfaces, finished the surfaces even and smooth without using extra cement including two coats of white wash complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacturer of paint and applying two coats of exterior anti fungal acrylic emulsion paint (weathercoat of Berger paint or Apex of Asian paint,equivalent in Nerolac etc) over a coat of exterior water based primer over external putty to have smooth surface of same make all as specified and prescribed by manufacture of paint and as directed at site by Engr-in-Charge. Note for item No. 01 to 05 :- The work is required to be carried out at non-accessible roof upto G+3 storey. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.)
Removal of existing roof treatment i.e. APP Membrane, brick tiling including concrete padding and benching and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material without damaging existing serviceable structure complete to receive new roof treatment including rubbish off the premises upto a distance exc 250 mtr but n.exc 500 mtr complete all as specified and directed by Engr-in-Charge. (Note : The work is required to be carried out at non-accessible roof upto G+3 storey. The contractor shall make arrangement of scoffolding , safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.)
M&L for PCC (1:2:4) Type B-0 (using 12.5mm graded stone aggregate) pedding mixed with liquid water proofing compound (as per manufacture direction and paid separately) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/mortar to old surface as per manufacturer direction and finishing the surface even and smooth (without usin extra cement) as in roof padding/Sunken floor, kerb/bencing alongwith parapet including rounded, chamfered on edges complete all as specified and directed by Engr-in-Charge. (Note : Proportion of mix and method of mixing of approved concrete admixture should be applied as per manufacturer's printed instructions) (Note : The work is required to be carried out at non-accessible roof upto G+3 storey. The contractor shall make arrangement of scoffolding , safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.)
M&L for rendering 10mm thick screed bedding in CM (1:3) mixed with acrylic bonding compound SBR Latex liquid polymer finished the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. (Note : Prpportion of mix and method of mixing of approved liquid water proofer admixture should be applied as per manufacturer's printed instructions) (Note : The work is required to be carried out at non-accessible roof upto G+3 storey. The contractor shall make arrangement of scoffolding , safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.)
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer's instructions with following course of description below :- (i) Applying one coat of bituminious primer evenly @ 0.30 Kg/Sqm till the surface is properly impregnated. (ii) Providing APP based 5 layer polymeric membrane minimum weighting 3.60 Kg/Sqm and minmum 3mm thick reinforced with polyester non-woven fabric matt (weight not less than 150 gms/Sqm) centre core laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75mm and end overlap of 100mm. All overlap joints shall br sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer. (iii) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP Membrance. (Note: the work in respect of water proofing treatment shall be carried out only by authorized/approved applicator of the manufacturer/firms of app membrane. The contractor shall submitted 10 year company back warranty before claiming payments complete all as specified and directed. (Note : The work is required to be carried out at non-accessible roof upto G+3 storey. The contractor shall make arrangement of scoffolding , safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.)
M&L for Cutting and opening cracks to a depth of 10mm x 10mm in V shape by mechanical means, cleaning all dirt and loose particles using Nitobond SBR/Sbr latex of Fosroc/Sika/CICO having specific gravity ranging from 1.015 to 1.040 @27 deg celsiusmixed in the ratio of 1(polymer) : 3(Cement) maintaining water/cement ratio 0.35 to achieve thixotropic consistency.
M&L for providing chemical injection treatment in the form of pressure grouting to the cold joint by injecting cement slurry(Preffered cement should have min blain value 300-500 sqmtr per kg) mixed with incl liquid water proofing compound to required consistency through the pre fixed PVC nozzle in the 18mm dia hole fixing of PVC nozzle with Renderoc Plug and final Cutting the projected nozzle and sealing off the PVC Nozzle after the injection operation is over with Renderoc plug non shrink rapid setting mortar compound finishing curing etc as per manufacturer specifications and as directed complete all as specified and directed.
Taking down existing PVC water tanks of any capacity and refixing the same after water proofing treatment including disconnecting and refixing of GI pipe of any dia with fittings complete all as specified and directed by Engr-in- Charge.
S&F Informatory Reflective sign board having High intensity prismatic tape base and font duly fixed on 2/3 mm thick aluminium sheet, matter to be laser cut and fixed on sheet. Matter to be in bilingual with logo as given incl boarder and arrow sign. Aluminum sheet to be fixed wtih and incl 25 mm SS304 grade frame around. Board incl frame to be fixed with and incl 50 mm round/ square SS 304 grade pipe (02 Nos) with 50 mm spacer pipe between board and post with SS fancy ball on top of each post. Height above ground 2.00 m and below ground 0.45 m, incl embedding in ground with PCC 1:2:4 complete all as specified and directed. Make of High Intensity reflective tape shall be 3M/DM. The size of board shall be as under:
1.20 m x 0.90 m Single side reflective
1.20 m x 0.90 m Both side reflective
1.20 m x 1.20 m Both side reflective
0.90 m x 0.60 m Single side reflective
S&F Informatory Reflective Side slanting sign board having High intensity prismatic tape base and font duly fixed on 2/3 mm thick aluminium sheet, matter to be laser cut and fixed on sheet. Matter to be in bilingual with logo as given incl boarder and arrow sign. Aluminum sheet to be fixed wtih and incl 25 mm SS304 grade frame around. Board incl frame to be fixed with and incl 50 mm round/ square SS 304 grade pipe (02 Nos) with 50 mm spacer pipe between board and post with SS fancy ball on top of each post. Height above ground 2.00 m and below ground 0.45 m, incl embedding in ground with PCC 1:2:4 complete all as specified and directed. Make of High Intensity reflective tape shall be 3M/DM. The size of board shall be as under:
1.80 m x 1.20 m Both side reflective
1.20 m x0.90 m Both side reflective
S&F Informatory/ Caution/ Parking/ Speed limit Reflective sign board having High Intensity prismatic tape base and font duly fixed on 2/3 mm thick aluminium sheet, matter to be laser cut and fixed on sheet. Matter to be in bilingual with sign as given incl boarder . Aluminum sheet to be fixed wtih and incl 25 mm SS304 grade frame around. Board incl frame to be fixed with and incl 50 mm round/ square SS 304 grade pipe with SS fancy ball on top of each post. Height above ground 2.00 m and below ground 0.45 m, incl embedding in ground with PCC 1:2:4. Make of High Intensity reflective tape shall be 3M/DM. The size of board shall be as under:- 600x900 mm with Both side reflective
S&F Convex mirror with ABS frame of size 60 cm dia fixed on MS Pipe and embedded in ground with PCC 1:2:4.
S&F Triangular Reflective sign board having High Intensity prismatic tape base and font duly fixed on 2/3 mm thick aluminium sheet, matter to be laser cut and fixed on sheet. Matter to be in bilingual with sign as given incl boarder . Aluminum sheet to be fixed wtih and incl 25 mm SS304 grade frame around. Board incl frame to be fixed with and incl 50 mm round/ square SS 304 grade pipe single post. Height above ground 1.2 m and below ground 0.45 m, incl embedding in ground with PCC 1:2:4. Make of High Intensity reflective tape shall be 3M/DM/ Avery Dennison. The size of board shall be as under:- 750 x450 mm with Both side reflective
S&F Informatory Reflective sign board having High Intensity prismatic tape base and font duly fixed on 2/3 mm thick aluminium sheet, matter to be laser cut and fixed on sheet. Matter to be in bilingual with logo as given incl boarder and arrow sign. Aluminum sheet to be fixed wtih and incl 25 mm SS304 grade frame around. Board incl frame to be fixed with and incl 75 mm round/ square cantilever MS pipe attached with and incl MS Pipe of 100 mm dia and height above ground 6.00 m and below ground 1.20 m with 6 mm base plate of 0.50x0.50 m, incl embedding in ground with PCC 1:2:4 and anchoring with side wall with MS angle complete all as specified and directed. Make of High Intensity reflective tape shall be 3M/DM/ Avery Dannison. The size of board shall be as under:- 2.10 m x 1.50 m both side reflective
Supply & Fixing in repair liner D 3 (modified) Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair PIST + GPIN + CRCLP D 3 -non EM ,Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair OILRING VIT -142X4-5, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair KIT PISTEN RING SET, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair BUSH -CONNROD -S/END, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair MAIN BERING SET NEW D. EN, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair CONROD BEARING SET NEW D EN, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair OILSEAL=110 X 90 X 12 MM THK , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair OIL SEAL (FLYWHEEL SIDE) , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair INLET VALVE KV 2995 , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair VALVE CONE OUTLET KV2996, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair INJECTOR SL Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair VALVE GUIDE -D 3/D 4 , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair V S INSERT INLET SEMIFINI, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair EXH V S INSET SEMIFINI, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair VALVE STEAM SEAL - TBD3 ENGINE, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair GASKET CYL HEAD (128DIA), Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair WATER PUMP ASSEMBLY D 3 , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair FUEL PUMP & INJECTORS CALIBRTION, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
HEAD REPAIR / REPLACEMNNT AND FACING CHARGES, for 400 KVA capacitie of DG Set complete all as specified and as directed.
TURBO REPAIR & SERVICE, for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair CRENK CASE LINE BOOR & GRINDING, for 400 KVA capacitie of DG Set complete all as specified and as directed.
MAJOR OVERHAULING CHARGES , for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair V BELT AX -65 COGGED, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair RADIATOR HOSE SET , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair OIL PUMP , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
REDIATOR REPAIAING WITH COOR, for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair SET OF JOINTS Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair SET OF O RINGS FOR TBD4IV12, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair FUEL PIPESET OF COPPER WASHER, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply FILLING And drain out ENGINE OIL, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair OIL FILTER , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair FUEL FILTER KIT 1.1 LTS. , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair OUTER ELEMENT , Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair INNER ELEMENT, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
Opening dismantling and fitting charges and LOADING / UNLOADING OR FRIGHT CHARGES for 400 KVA capacitie of DG Set complete all as specified and as directed.
Supply & Fixing in repair FUEL PIPE SET, Make : MICO / Kirloskar / Ruston/ Greaves cotton as required at site for 400 KVA capacitie of DG Set complete all as specified and as directed.
LOADING / UNLOADING OR FRIGHT CHARGES for 62.5 KVA capacitie of DG Set complete all as specified and as directed.
Disconnecting & taking out existing LT cable of any size form site and relaying in duct all as specified and directed.
Supplying, laying, commisioning,and testing of 1.1KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable ( conforming to IS7098) ISI marked in trenches/ducts/through GI pipes under roads of size 240 sqmm 3.5 core complete all as specified and directed .
Supplying ,laying, commisioning,and testing of 1.1KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable ( conforming to IS7098) ISI marked in trenches/ducts/through GI pipes under roads of size 70 sqmm 3.5 core complete all as specified and directed .
Supplying ,laying, commisioning,and testing of 1.1KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable ( conforming to IS7098) ISI marked in trenches/ducts/through GI pipes under roads of size 185 sqmm 3.5 core complete all as specified and directed .
Supply and fix in replacement change over switch 415V in sheet metal enclosures 4 pole of capacity 160 Amps complete all as specified and as directed .
Supply and fixing in replacement and charging maintenance free 12 Volt 180AH battery complete with initial charging including electrolite / distilled water etc and fixing as required at site to the concerned DG Set complete all as specified and directed. (Make: EXIDE model EL Plus/Amron/Luminious as approved by GE.)
All as per item No 62 above but of 12V 150 AH. (Make : EXIDE. Model -EL Plus/Amron/Luminious as approved by GE.)
Supply and fix in replacement change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps complete all as specified and as directed .
Supply and fix in replacement change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps complete all as specified and as directed .
Supply in replacement of 415 VAC 3 phase power contactor type MNX 650 AMP with 2NO+2NC for 400 kva DG set with new ones complete all as specified and as directed .
Taking out old painted surface and painting of two coats of synthetic enamel paint over one coat of red oxide of superior quality by spray painting machine for DG set cap 400 KVA in authorised workshop / painter complete all as specified and as directed.
Taking down old UNSV & supply fixing self motor of cap 400 KVA DG Set complete all as specified and directed.
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed
Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
Sand cushioning to underground cable provided with a layer of 8 cm deep before laying the cable and 15cm deep after laying and stretching the cable including hand punning and consolidating complete.Note: for payment purpose punned thickness shall be measured.
M&L for well brunt bricks sub class 'B' in old size as cable protection laid flat width wise complete all as specified and directed.
Supply, laid in trenches or fixed on wall pipe galvanised light grade with all fitting of size 40 mm dia
Supply, laid in trenches or fixed on wall pipe galvanised light grade with all fitting of size 80 mm dia
Removing of existing bruntout asbestos rope from silincer and replacement of new ausbrust rope / strips complete all as specified and directed.
Material and labor for supply,fabrication,installation,testing and commissioning Factory made LT panel board,indoor/outdoor type totally enclosed,dust and vermin proof,suitably ventilated, Wall/floor mounted, 415 volts, 3 phase and neutral 50 Hz AC/DC supply system,fully compartmentalized, both sides openable made out of 3.15mm thick CRCA sheet protection of enclosed IP54 as per IS 2147 of 1962 with 7 tank process pre-treatment and powder coated of approved color including suitable framework/support made out of suitable size angle iron/flat iron front opening type with provision for cable entry with proper ferrule and cable glands internal wiring with PVC insuleted multistandard copper conductor FRLS cable of adequate size (1.5sq mm ) including required civil works anchoring bolts for fixing, PCC foundation etc. with and including following complete all as specified and directed. (a) Bus bar chamber : electrically grade shredded alluminium bus bar of capacity 200 Amp for each phase and 200 Amp for neutral and current density 0.80A/sq mm. (b) Change over switch 100 Amp capacity- 01 No. (c) MCCB 4 Pole of capacity 100 Amp - 02 Nos
Material and labor for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick weld directly in ground. (earth pit not less then 2.25m depth below ground level at any tyoe of strata) with top edge of the earth plate not less then 1.5m below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate connected by 4.0 Sqmm mm GI strip As earth lead by means of brass nut and bolt thimbles checked nut , washer including concrete chamber of PCC 1:3:6 type C1 (using 20 mm graded stone aggregate ) with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx300mm 15mm thick plaster in cm 1:4 funnel with wire mesh RCC pit cover of 320x320x80 mm size ( 1:2:4) type d1(using 20mm graded stone aggregate) reinforced with xpm all as shown in electrical plate no. 3 of MES SSR part 1(2009) and specified including and provision of GI strip upto 7.5m long with 20mm dia light weight GI pipe protection and water pipe of 20mm bore medium grade including all excavation and earth work and connecting earth strip to panel including testing on completion complete all as specified and directed by engineer incharge. Note - RCC pit cover shall be precast of RCC (1:2:4) type d1 80 mm thick reinforced with xpm weighting not less then 4kg /sq m. in lieu of CI cover. 2. Cost of additional GI strip more then 7.5m will be measured and paid seprately under relevent items.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
S & F Table fan / Wall fan 400 mm sweep 230 V, complete all as directed. Make: Bajaj/Havells/Crompton
S & F exhaust fan 240 volts Ac 50 Hz 300 mm sweep matellic body (RPM will not be more then 900) including louvers and cutting as required size and shape complete all as directed. Make: Bajaj/Havells/Crompton
S & F exhaust fan 240 volts Ac 50 Hz 450 mm sweep matellic body (RPM will not be more then 900) including louvers and cutting as required size and shape complete all as directed. Make: Bajaj/Havells/Crompton
S & F electric water heater storage type geyser (ISI marked ) 5 star rated inner stainless steel body with steel inner tank and heating element upto 2 KW of capacity 25 Ltr complete grouting wall with suitable size of nut & bolts washer as required at site with cold water and hot water connection pipe as per required at site,complete all as directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
TRINITY CONSTRUCTION
Bedi Refrigeration Works
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .