Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical BORMURA MIRIPATHAR PO SAIKHOWAGHAT PS DHOLLA TINSUKIA PIN 786154 | TINSUKIA | ASSAM | 786154 | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | Sajal Kr Acharjee L1 |
|---|---|---|---|---|
| 1.00 | Civil Works:
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns etc. as directed and specified (A) Up to a depth of 2.00m below the existing ground level (a) In ordinary soil. | 176.98 | cum | 27,431.9 ₹27,431.9 Lowest |
| 2.00 | Earth / Sand filling in plinth in layer not more than 150mm thick including necessary carriage, watering etc. with silt by truck carriage including loadsing and unloading. | 188.53 | cum | 91,437.05 ₹91,437.05 Lowest |
| 3.00 | Raising low site around the building with approved soil (ii) Other than Guwahati municipality area. | 710.02 | cum | 2,13,006 ₹2,13,006 Lowest |
| 4.00 | PCC work with coarse aggr. Of size 13 mm to 32 mm in foundation bed etc.(in prop. 1:3:6) | 14.02 | cum | 84,470.5 ₹84,470.5 Lowest |
| 5.00 | PCC Floor base in prop. 1:3:6 …….. 50 mm thick | 207.32 | cum | 73,598.6 ₹73,598.6 Lowest |
| 6.00 | Pre construction anti-termite treatment at the bottom of foundation pits …… with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution | 116.8 | Sqm | 12,848 ₹12,848 Lowest |
| 7.00 | Pre construction anti-termite treatment in the back fill …… complete | 116.8 | Sqm | 12,848 ₹12,848 Lowest |
| 8.00 | Pre construction anti-termite treatment … in the entire levelled area after plinth filling …. Complete | 209.47 | Sqm | 23,041.7 ₹23,041.7 Lowest |
| 9.00 | Pre construction anti-termite treatment along the external perimeter of the building ……. Complete | 57.94 | Rm | 5,794 ₹5,794 Lowest |
| 10.00 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | 29.53 | Sqm | 7,530.15 ₹7,530.15 Lowest |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
22 Feb 2021, 12:00 pmClosed
Chief Engineer
Directorate of Agriculture, Assam, Khanapara, Ghy-22
Construction of Office Building of Executive Engineer(Agri), Silchar, Cachar
2020_DAASC_19712_2
AGRI/ENGG/4769/ Pt.III/2018-19/132 Dt.18/12/2020
Open Tender
Civil Works
Works
365 days
Silchar
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Directorate of Agriculture
₹3.4 L
Yes
Engineering Section of Directorate of Agriculture
3 Jun 2021
16 Feb 2021
22 Feb 2021
16 Feb 2021
22 Feb 2021
17 Feb 2021
17 Feb 2021
Civil Works: Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns etc. as directed and specified (A) Up to a depth of 2.00m below the existing ground level (a) In ordinary soil.
Earth / Sand filling in plinth in layer not more than 150mm thick including necessary carriage, watering etc. with silt by truck carriage including loadsing and unloading.
Raising low site around the building with approved soil (ii) Other than Guwahati municipality area.
PCC work with coarse aggr. Of size 13 mm to 32 mm in foundation bed etc.(in prop. 1:3:6)
PCC Floor base in prop. 1:3:6 …….. 50 mm thick
Pre construction anti-termite treatment at the bottom of foundation pits …… with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution
Pre construction anti-termite treatment in the back fill …… complete
Pre construction anti-termite treatment … in the entire levelled area after plinth filling …. Complete
Pre construction anti-termite treatment along the external perimeter of the building ……. Complete
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/ reinforced cement concrete works with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid I) Using mixture machine, M25 Grade In sub-structure below plinth
Providing and laying plain/ reinforced cement concrete works with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid I) Using mixture machine, M25 Grade In super-structure above plinth
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in a) Foundtion, footing, base of columns, pile cap, raft and mass concrete works etc. using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in Column, Pillars, Post 7 Strut, using 25 mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in Sides of tie beam, grade beam etc at or below ground level. (ii) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in c)Sides and soffits of beam, beam hunchings, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0m (i) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in e) Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies and the like. (a) Using 25mm thick plank.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in d) Staircase with sloping or stepped soffits including risers and stringers but excluding landing.(using 38mm thick)
Extra for each subsequent floor or part thereof above the First Floor level…
Providing brick soiling in foundation and under floor with stone/ best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub-grade as directed including all labour and materials, and if necessary dewatering, complete.
Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sud-structure upto plinth level.(a) In prop. 1:4
112mm thick 1st class brick nogged wall in cement mortar including out joints and curing complete as directed in super structure above plinth upto 1st floor (Protruding M.S rod/ Tor steel of column to be embedded in cement mortar and will be measured and paid for separately) (a) in cement mortar in prop. 1:4
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.
Providing wood work in frame (chowkhats) of door, windows clearstory and other similar works wrought, frammed and fixed and in position in contact with C.C or brick masonry walls including supplying, fitting with M.S flat hold fast (40mm x 3mm x 250mm) as design embedded in cement concrete block in prop 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. With 1st class timber(Hollock/ Sundi)
Providing, fitting and fixing factory made Santro Flush shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkhat) with necessary hinges, screws, bolts, etc. as specified and directed at all levels & glazing viewing is providing in door shutter as per dwawing. (Door fixtures and fittings to be measured and paid separately) (ii) 35mm thick.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rub) (a) 2 track sliding window. (ii) 5mm frosted glass.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for RCC work/ R.B walling including straightening, cleaning, ctting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (for all level). (I) TATA/ SAIL
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
Providing, fitting and fixing M.S grills/ MS Tube of required pattern for windows/ clerstory/ openings with M.S flats at required spacing and frame all round, square or ornamented grill. (a) Fixed to Brick/ P.C.C/ R.C.C
Providing and fixing in position collapsible MS shutters with vertical channels………….locking arrangements, stoppers, handles including applying and priming coat of red lead paint.
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirting risers and treads of steps over 15mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A Tile (Choksey/ Sika/ Pedelite/ Rouf) / white cement slurry mixed with approved pigment to match shade of a) Normal range (Size: 600mm x 600mm) i) Asian Made
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 including cutting where necessary finished with flush pointing with Fix-A tiles (Choksey/ Sika/ Pedelite/ Rouf) white cement slurry mixed with approved pigmnet to match shade of tiles complete at all level as specified and directed. (cement plastering to be measured and paid separately) Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls, means both interior and exterior walls) Normal range ( size: 200mm x 200mm and above), Orient made
Cement plaster skirting with cement mortar in prop. 1:3 finished with a floating coat of neat cement including rounding of junctions with floor. a) 15mm thick.
15mm thick cement plaster in single coat on rough side or single or half brick wall for (a) In cement mortar 1:4
Extra over items 6.2.1 to 6.2.5 for plastering on ceiling and soffits of stair up to 1st floor level (instead of platering on walls) including curing complete as directed.
Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed.
Providing surface preparation for walls, ceiling etc. using average 1.50mm thick plaster of Paris including clearing, rubbing with sand paper, filling gaps, depressions etc. where necessary, with chalk powder and plaster of Paris paste, making the surface even and smooth complete at all levels as specified and directed.
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Wall painting (two coats) with Plastic emulsion paint approved brand and manufacture (Asian/ Nerolac/ Berger) on new surface to give an even shade after throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic emulsion paint approved brand and manufactue (Asian/ Nerolac/ Berger paint/ CI paint/ J&N paint).
Applying one coat of cement primer of approved brand and manufacture on new surface to give an even shade after throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
Fininishing wall with water proofing weather coat smooh anti-fungal exterior painting of approved make of Dulux Paint………..comple as directed at all levels (two Coats)
Applying priming coat new wood and wood based surfaces over 100mm in girth/ width after and including preparing the surface by throughly cleaning oil, grese, dirt and other foreign matter, sand papering and knotting.
Painting two coat (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J&K paint/ Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter sand papering and stopping, (i) Surface over 100mm in width/ grith, General purpose (Asian paint/ Berger paint/ ICI paint/ J&K paint/ Nerolac)
Applying primary coat over new steel and other metal surface over 100mm in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed red-lead/ red oxide primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J&K paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width/ grith.a) General purpose (Asain paint/ Berger paint/ ICI paint/ J&K paint/ Nerolac).
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright natural Matt & satin finished). Handles, 150mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright natural Matt & satin finished). Tower bolt (i) 300mm x 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright natural Matt & satin finished). Lock, 100mm (Godrej with handle, 6-lever).
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright natural Matt & satin finished). Door stopper with rubber stopper
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright natural Matt & satin finished). Sliding door bolts (ii) 250mm x 16mm.
Preparing the RCC surface in roof slab, chajjas, terrace, sunken slabs, septic tank, overhead tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing the surface to dry complete as directed at all levels.
Providing and applying over roof/ raft slab two coats of water proofing slurry prepared with cement, fine sand inprop.1:1 admixed with modified acrylic polymer like cemflex of Sika India Ltd., by brush @ 0.25% of cement-sand mixture (by weight) after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified and directed by the department complete.
Supplying, providing, mixing and laying of concrete screed of average 20mm thick or as per drawing/ requirements in proportion 1:2:4 with 10mm and down well graded aggregates and admixed with a waterproofing plasticizer like Plastocrete plus of Sika India ltd. @ 0.2% by weight of cement and thereafter scoring the top surface of the concrete screed @ 200mm c/c as specified and directed by the Department.
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in prop. 1:4 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (i) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing corrugated galvanised Iron sheet roofing of TATA SHAKTEE/ SAIL including fitting and fixing necessary galvanised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (b) 0.50 mm thick.
Providing, fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S black-tubes conforming to relevant I.S code, as per approved design and drawings including providing M.S cleats, base plates, bolts and nuts and one coats of red oxide Zinc Choromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawings as directed.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) b) 29mm thick
Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels. Providing and fixing aluminium step edging with anodised aluminium angle to stairs at all levels. Providing and fixing aluminium step edging with anodised aluminium angle to stairs at all levels. (ii) With angles of size 57mm x12 mm x 3mm
Providing and fixing aluminium step edging with anodised aluminium angle to stairs at all levels. (ii) With angles of size 57mm x12 mm x 3mm
Extra over item 11.3.2 for cutting R.C.C./brick steps for fixing of aluminium strip edging and making good to match the surroundings.
Sanitary Works: Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm ii) Hindware make
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) ii) Hindware make
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.
Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified.
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.
Providing, fitting and fixing CP towel rail complete as directed and specified.
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified.
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified.
Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.
C.P. Grating
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Water Supply Works: Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches b) 40 mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches c) 32 mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches d) 25 mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches e) 20 mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches f) 15 mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (b) Long body bib cock with wall flange
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (i)15mm dia
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed.
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
Labour for erecting and placing PCVCTank over the stagging of 5.00m up to 8.00m complete as directed. (c) 1000 litre capacity
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. iv) Bore hole of 150mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. v) 110mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long. iv) 100mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE i) 25mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE ii) 32mm diameter
Flushing, clearing, washing and watering of the tube well
1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Electrical Works: Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. 1.1.1) Short point up to 3.00 metre. length.
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. 1.1.2) Medium point up to 6.00 metre. Length.
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. 1.1.3) Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Medium point up to 6.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in flat 25mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface with flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying and fixing of Call bell ( Buzzer ) including 6 amp capacity flush type bell push switch including connection as approved by the Deptt.)as required.
Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Supplying fiting and fixing of ceiling fan regulator includingconnections etc. complete as required. Electronic type
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) wiring system.
Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department.
For LT line & service connection
Dismantling & Demolishing Works: Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levels.
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels.
Demolishing plain cement concrete including disposal of debris as directed for all levels
Reparing of existing store room with old materials as directed
Reparing of existing open shed as directed
Repariring of Existing Gate as directed
Shifting of Office Materials as directed
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.37 MB
Drawings.pdf
Additional Documents • 2.29 MB
BD.pdf
Tender Documents • 0.97 MB
FOB.pdf
Additional Documents • 0.01 MB
BOQ_33185.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .