Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹20.9 L+₹99,822.90 (5.00%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
28 Nov 2020, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR TO HANGER HALIPAD RUNWAY TAXI TRACK HARDSTANDING PATH DRAIN AND ATC BLOCK AT 23 I AND 39 I R AND O UNDER GE EAST BAREILLY
2020_MES_390841_1
C/8878/E8
Open Tender
Civil Works
Item Rate
180 days
GE EAST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE EAST BAREILLY
₹60,000
Yes
15 Dec 2020
29 Oct 2020
30 Nov 2020
29 Oct 2020
28 Nov 2020
16 Nov 2020
29 Oct 2020 - 11 Nov 2020
Amount
Demolition of Brickwork built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Demolition of concrete ( unreinforced ) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engineer-in-Charge.
Demolition of bricks (laid flat or on edge) or brick tiles in floors , channels, kerbs, aprons, etc. complete all as specified and as directed by the Engineer-in-Charge.
Demolition of RCC of any description and in any position not other wise specically provided for cement concrete reinforced (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling galvanised sheet (corrugated or semi corrugated etc) sheets in roof covering etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of wall and ceiling boards/ fibre, pulp, insulation etc or insulation boards/ slabs/blankets any thickness incl cover fillets complete all as specified and as directed by the Engineer-in-Charge.
Dismantling timber in fillets, rails, posts, rafters, purlins, etc under 40 sq. cm in (unframed work) section complete all as specified and as directed by the Engineer-in-Charge.
Dismantling structural steel work including doors, gates incl framed truss etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed by the Engineer-in-Charge.
Dismantling fencing wire mesh, any type complete all as specified and as directed by the Engineer-in-Charge.
M & L for PCC 1:3:6 Type C2 (using 40 mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and as directed by the Engineer-in-Charge.
M&L for providing precast cement concrte (1:2:4) type B1 ( using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face complete all as specified and as directed
M&L for Providing precast ce- ment concrete in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and as directed
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex tra cement, including forms, moulds, mitred/stopped ends etc etc complete all as specified and as directed
M & L for providing cement concrete 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth, string, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates,bed blocks for Air field Light, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
M&L for brick work sub class B laid flat in floors/drain etc old size bricks bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S&F in repair Stainless Steel decorative droppery rod (DDR) 25mm nominal dia having wall thickness not less than 1mm thick fixed in repairs incl necessary holder / brackets, curtain rings complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc. 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc. 1.5 sq. m each complete all as specified and as directed by the Engineer-in-Charge
Taking down shutters of any description area exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by the Engineer-in-Charge
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F second class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed
S/F 2nd class HW Factory made 35 mm thick Glazed and skeleton shutter, open rebated and prepared to receive glass, wire gauze, etc. divided into squares, with plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
Ditto all as per item no 30 above but 6 to 8 mm dia complete all as specified and directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; gates,ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L glazed ceramic coloured tiles in vertical surfaces 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including rendering 10mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L glazed ceramic coloured designer tiles in vertical surfaces area exc 0.11 Sqm but nexc 0.16 Sqm each ,7-8 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match over nd including rendering 10mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge
M & L for Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inlcuding 15mm thick screed bed or bedding layer in CM (1:4) for laying tiles in floors etc. complete all as specified and as directed by the Engineer-in-Charge
M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0. 38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specifed and as directed.
M&L 100mm thick cement concrete (1:2:4) type B-2( using 40mm graded crushed stone aggregate) as in pavement , floors including all complete all as specified and directed
M&L 75mm thick cement concrete (1:3:6) type C2( using 40mm graded crushed stone aggregate) as in sub base of floors and pavings complete all as specified and directed
M&L 100mm thick cement concrete (1:4:8) type D-2 ( using 40mm graded crushed stone aggregate) as in sub base of floors including all as specified and directed
M&L for rubber moulded chequered cement concrete tiles of size area exceeding 0.04Sqm but nexc 0.09 Sqm each of 25mm thick, set with grey cement and no pigment jointed and pointed in neat cement slurry in floor path,laid over & including 100mm thick PCC(1:4:8) type D-2( using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M & L for Vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36sqm but n exc 0.72 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thick screed bed in CM (1:6) complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M& L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces with using WPC @ 2% by weight of cement & finished the surface even and smooth with out using extra cement complete all as specified and directed. (NOTE:- WPC will be measured and paid separately as "SUPPLY ONLY" ).
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces & finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coat of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for preparation of new plaster surfaces of wall & applying two coat of oil bound distemper over a coat of putty complete all as specified and directed.
M&L for preparation of old treated wall surfaces & applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of old wall surfaces & applying one coat of Oil Bound Distemper complete all as specified and directed.
M&L for preparation of old plaster surface & applying two coat Oil Bound Distemper on ceiling complete all as specified and directed.
M&L for complete removal of old existing treatment from wall surface and applying two coats of oil bond distemper over one coat of primer over a coat of wall care putty complete all as specified and directed
M&L for preparation of old wall surfaces including complete removal for existing treatment & applying two coat of Exterior Emulsion paint (Apex ultima or Equivalent) over a coat of external wall care putty complete all as specified and directed.
M&L for preparation of old wall surfaces or Fascia including complete removal for existing treatment applying two coat of Exterior Emulsion terracotta red or any colour (Apex ultima or Equivalent) complete all as specified and directed.
M&L Preparation of New wooden surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coats of pink primer.complete all as specified and directed.
M&L Preparation of New steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coats of red-oxide zinc chrome primer complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth including knotting and stopping and applying one coat of synthetic enamel paint (any tint/shade) complete all as specified and directed
M&L for preparation of old painted steel surfaces of any description and applying one coat of synthetic enamel paint (any tint/shade) to the hanger building, watch tower, gates, windows etc of any height , including necessary scafolding complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from Metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
M & L for sheet glass 3.5 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
M & L for sheet glass 6 mm thick, ordinary quality and glazing with oil putty in square area exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
M & L for frosted glass of 5 mm thick and glazing with oil putty or rubber beading in squares area exc 0.50 sq m complete all as specified and as directed by the Engineer-in-Charge
S&F for toughened glass tinted 12 mm thick, superior quality area exc 1 sq m using Stainless steel fittings such as peg stay, handle 100mm long and floor Spring in each complete all as specified and as directed by the Engineer-in-Charge
S&F in repair Box type Venetian blind coloured strips with design width of the strip 75mm x 1mm thick top rod inches at brackets included type complete all as specified and as directed by the Engineer-in-Charge
S&F in repair PVC hollow interlocking wall paneling of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 kg / cbm density manufactured by an ISO-9000 certified company. The strips should two PVC strips. The PVC strip shall be fixed to the wall using 65mm long M.S screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement.etc complete all as specified and directed.
S&F aluminium alloy powder coated aluminium door frame fixed with side hung shutters and glazing fixed with and including 5.50mm thick tinted glass fixed with rubber gasket with aluminium heading, clips frame made with aluminium box sec as appended below complete all as specified and directed :- (a) Frame 100x44x1.48mm thick with rawl plug (b) Middle and lock rail : 150x44x1.48mm thick (c) Bottom rail : 150x44x1.48mm thick (d) Top rail/style : 85x44x1.48mm thick (e) Aluminium beading : 0.7mm thick (f) Aluminium handle D type 150mm long, aluminium tower bolt 9.9mm dia shoot 200mm long brass mortise lock 100mm 4 leaver aluminium stopper, cleat double action floor spring hydraulically regulated made of n.less than 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other part of steel heavy duty ( Make Sandhu ISI marked or its equivalent approved make) (g) Making good of wall surface to match with existing surface complete.( Make of Aluminium section ;- INDALCO/JINDAL or equivalent as approved by GE)
S&F sliding windows of aluminium alloy powder coated, window and frame with movable shutter ( sliding on minimum two PVC roller of best quality, for each shutter ) on tracks ( three tracks ) and glazzing with and including 5.00 mm thick tinted glass fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame : 95x35mm X 1.48 mm thick for three tracks (ii) Top/bottom rail and style / rail of shutter : 19x38x1.48mm thick and over. (iii) Aluminium beading - 0.7mm thick (IV)Aluminium wire cloth0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium wire staples complete. (iv) Aluminium fittings such as peg stay, aluminium hinges, aluminium handle 100mm long , aluminium tower bolt 100mm long (v) Making good of wall surfaces to match with existing surfaces complete all as specified and directed..( Make of Aluminium section ;- INDALCO/JINDAL or equivalent as approved by GE)
S&F sliding windows of aluminium alloy powder coated, window and frame with movable shutter ( sliding on minimum two PVC roller of best quality, for each shutter ) on tracks ( Two tracks) and glazzing with and including 5.00 mm thick tinted glass fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame :63x35mm X 1.48 mm thick for two tracks. (ii) Top/bottom rail and style / rail of shutter : 19x38x1.48mm thick and over. (iii) Aluminium beading - 0.7mm thick (IV)Aluminium wire cloth0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium wire staples complete. (iv) Aluminium fittings such as peg stay, aluminium hinges, aluminium handle 100mm long , aluminium tower bolt 100mm long (v) Making good of wall surfaces to match with existing surfaces complete all as specified and directed..( Make of Aluminium section ;- INDALCO/JINDAL or equivalent as approved by GE)
S & F partition wall of powder coated aluminium hollow sections members of size 63.50 mm x38mmx 1.48 mm thick with distance of vertical hollow section 1.2M to 1.8 M and 1.2 mtr height wall having top rails ,bottom rails and middle rail of size 63.50 mm x38mm x 1.48 mm and upto middle rail wall panels shall be covered by 12mm thick prelaminated particle board ,interior grade both sides with decorative choice laminations , fixed into the wall with aluminium clip and bolt, top hight of middle rail shall be 1 meter from floor and portion above middle rail shall beprovided with figured glass 5 MM thick fixed with aluminium stiprs/beadings with rubber gasket, sketch plan of wall as per existing or as provided by the Engineer-in-Charge compelte all as specified and directed.( Make of Aluminium section ;- INDALCO/JINDAL or equivalent as approved by GE)
S&F aluminium Alloy powder coated windows , ventilators frame with side hung shutters and glazing with and including 3.8 mm thick tinted glass fixed with rubber gasket with aluminium beading, clips , frame made with aluminium section as appended below:- (i) Frame : 65x40x1.48mm thick (ii) Top/bottom rail and style / rail of shutter : 44x47x1.48mm thick (iii) Aluminium beading - 0.7mm thick (iv) Aluminium fittings such as peg stay, aluminium hinges, aluminium handle 100mm long , aluminium tower bolt 100mm long (v) Making good of wall surfaces to match with existing surfaces complete all as specified and directed. ( Make of Aluminium section ;- INDALCO/JINDAL or equivalent as approved by GE)
M & L powder coated aluminum window/ doors grills fixing along with frame of following specification, grills with opening 69.4mm X 78.2mm grills thickness shall be of 6.4mm X 5.8mm having weight not less than 2.306 Kg/per sqm shape as ordered with frame channel of 34 X 11mm X1.7mm thick fixed with screw inside of the window all as directed by Engr-in-Charge and all as specified and as directed.
M&L for E-board false ceiling consisting of powder coated GI wall angle, main T and cross T of 25mmX 25 mm X 1.40 mm thick grid frame work, joist, angle/ Tee as directed and mild steel wire hook not less than 6 mm dia with arrangement for adjusting height of ceiling and including provn of 4 mm thick E- Classic board in pannel of size 600X600mm with necessary off cut including taking down and refixing of Electric fitting carefully complete all as specified and directed.
M& L for preparation of newly plastered wall surfaces and appltying three coats of texture (Domasc ) finished painting with the following process the surfaces should be completely dry and free from loose particles including preparing the surface with emry paper 180 nos and wipring clean and applying one coat of primer and allow drying for 6 to 8 hours then smoothen the surface by filling dints with thin coat of acrylie wall putty after drying for 4 to 6 hours and preparing the surface with emry paper and clean and applying another coat of primer and allow drying for 6 to 8 hours and then emulsion 1 Ltr with 500 ml water and applying with brush follwed by rolling with sponge roller or filter roller, applying three coat with brush and roller with and interval of 3 to 4 hours between successive coat all as per manufactures instruction complete all as specified and directed
M& L for preparation of newly plastered wall surfaces and appltying three coats of texture (Rustic) finished painting with the following process the surfaces should be completely dry and free from loose particles including preparing the surface with emry paper 180 nos and wipring clean and applying one coat of primer and allow drying for 6 to 8 hours then smoothen the surface by filling dints with thin coat of acrylie wall putty after drying for 4 to 6 hours and preparing the surface with emry paper and clean and applying another coat of primer and allow drying for 6 to 8 hours and then emulsion 1 Ltr with 500 ml water and applying with brush follwed by rolling with sponge roller or filter roller, applying three coat with brush and roller with and interval of 3 to 4 hours between successive coat all as per manufactures instruction complete all as specified and directed
M& L for preparation of newly plasted wall surfaces and appltying three coats of texture (Super fine) finished painting with the following process the surfaces should be completely dry and free from loose particles including preparing the surface with emry paper 180 nos and wipring clean and applying one coat of primer and allow drying for 6 to 8 hours then smoothen the surface by filling dints with thin coat of acrylie wall putty after drying for 4 to 6 hours and preparing the surface with emry paper and clean and applying another coat of primer and allow drying for 6 to 8 hours and then emulsion 1 Ltr with 500 ml water and applying with brush follwed by rolling with sponge roller or filter roller, applying three coat with brush and roller with and interval of 3 to 4 hours between successive coat all as per manufactures instruction complete all as specified and directed
Providing & fixing 10mm thick plaster of paris false ceiling bending as required shape with two coats of plastic emulsion paint over a coat of primer on decorated surfaces of ceiling including 26 gauge galvanished iron sheet 'C' shaped main member @750 mm C/C cross member 'U' shaped @450 mm c/c and perimeter of 'C' shaped GI wire mesh having aperture 6.5 mm with 26 gauge wire GI wire 6mm dia or more or FI 40x4mm thick for hanging arrangement with MS suspension.fastner spaced @ 450mm c/c in both direction the 'C' member shall be made out of not less than 90mm wide GI sheet strip and side tray as required of approximate size 3.5 Mtr height as required at site complete all as specified and directed.
M&L for sand filling under floor or paving lading layer 50mm thick spread levelled and rammed including watering complete all as specified and directed.
M& L for Machine pressed precast conctete interlocking paver block any shape and size coloured confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed.
Material and labour 20-25 mm wide expansion joints upto full depth of concrete slab (250mm) filled with preformed compressible filler board (Silfex supremen base) precut of specified depth provision of closed cell polythene back up rod 25 mm dia (minimum depth over back up rod shall be 14 - 15mm) 02 coats of priming the vertical side of joints and sealing the joints (Top 12mm with and using cold applied polyurethane sealent confirming to requrement of BS - 5212 type FB and applying masking tape on edge at joints to prevent accidental spillage of sealant and removing the masking tape after sealent is applied Sealent should have MAF minimum -+ 30% and manufacturers warrenty for 10 (ten) years complete all as per manufacturer instructions and directed complete as in repair work. Note :- (Rate included for taking out all existing filling material including cleaning preparation surfaces for filling new sealing material.)
Material and labour 8 to 15mm wide 22-25 mm deep construction joints 02 coats of priming and providing a back up rod 10mm dia and sealent with using cold applied polyurethane sealent (Top 10 mm leaving 2-3 mm recess) confirming to requrement of BS 5212 type FB and applying masking tape on edge at joints to prevent accidental spillage of sealant and removing the masking tape after sealent is applied Sealant should have MAF minimum + 30% and manufacturers warrenty for 10 (ten) years complete all as per manufacturer instructions complete all as specified and directed complete as in repair work. Note :- (Rate included for taking out all existing filling material including cleaning preparation surfaces for filling new sealing material.)
S&F in repairs Aluminium Composite (ALCO) panel exc 3 mm thick ,jointed with screw , cutting , edging, and grooves finished using epoxy silicon composite Resin compound of any colour, fixed on flat or curved surface complete all specified and as directed by Engineer in charge.
M&L for repair to steel window shutter, steps of ladder of Observation Post and like with necessary welding and cutting including any replacement of minor parts such as hinges, cleats etc complete all specified and as directed by Engineer in charge.
S & F in repairs for Vitreus China wash basin white flat back size 580x450mm including waste chain & plug but excluding taps complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs for Vitreus China counter wash basin ( cascade basin ) coloured of size 550x480mm including MS brackets, waste chain & plug but excluding taps complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repairs for 15mm bore, fancy type brass chromium plated bib tap of cast copper alloy capstan head ,screwed down, screwed for iron pipe or for brass ferrule , chromium plated, with wall flange Fixed in repairs complete all as specified and as directed by the Engineer-in-Charge
S & F in repairs for of ISI marked swan neck Pillar Tap of 15mm bore dia, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs for Stop/ Angle valve cast copper alloy screwed down high pressure with capstan head, fancy type chromium plated (Bore dia of pipe in 15mm) with wall flange fixed in repairs with long shank and cup complete
S & F in repairs brass chromium plated concealed stop valve fancy type (Bore dia of pipe in 15mm) with wall flange fixed with long shank and cup complete all as specified
S&F in repairs PVC pipe connection 450mm long 6kg F/sqcm pressure rating with flare nuts on both ends suitable for 15mm dia pipe complete
M & L for dismantling water tanks exc 250 but not exc 500 Litres, and removing to store complete all as specified and as directed.
M & L for dismantling water tanks exc 500 but not exc 1000 Litres, and removing to store complete all as specified and as directed.
M & L for 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multilayered, hoisted and fixed in position all as specified in SSR Part-I and as directed by the Engineer-in-Charge
M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multilayered,hoisted and fixed in position all as specified in SSR Part-I and as directed by the Engineer-in-Charge
Refixing only 500 Litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multilayered,hoisted and fixed in position all as specified in SSR Part-I and as directed by the Engineer-in-Charge
S & F in repair for ISI Marked 20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal complete all as specified and as directed by the Engineer-in-Charge
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal complete all as specified and as directed by the Engineer-in-Charge
S&F for 15mm bore `medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge
Refixing only 15mm bore `medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge
S&F for 20 mm bore `medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge
Refixing only 20 mm bore `medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge
S&F for 40mm bore `Medium grade` GI tubing in short lenght and fixed complete to walls or slab as in spouted pipe and casing to pipe complete all as specified and as directed .
Cutting chases in brick work in cement mortar for fixing 15mm bore GI pipe including making good the surface filled with cement mortar complete all as specified and directed.
S & F of 32mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed, complete all as specified and directed.
S&F in repairs for 75mm bore dia PVC ( SWR ) floor trap, with grating including jointing to waste pipe with solvent cement & fixed in cement concrete( 1:2:4) type B1 complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs for PVC (SWR ) gully trap 125/110 mm, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed by the Engineer-in-Charge
S & F Vitreous China bowl urinal flat back, of size 465 x 355 x 265 mm white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed in repairs complete all as specified and as directed by the Engineer-in-Charge
S & F in repairs vitreous China floor mounted Water closet cat NO-0213 Athena Closet of Parryware or equivalent with Flushing Cistern including making good to floor complete all as specified and directed.
S & F in repairs vitreous China squatting pan, `Orissa` pattern, size 580 x 440 mm white, with integral foot rests including making good to floor complete all as specified and as directed by the Engineer-in-Charge
Supply only 'P' or 'S' trap of 100mm bore complete all as specified and as directed
S&F in repair 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and dierected
S&F in repairs chromium plated Towel rail 60cm long complete all as specified and directed.
Dismantling of old unserviceable soil,waste pipes of any size and description all as specified and directed
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Refixing only 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Refixing only 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) 110mm bore bendsn complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends with access door complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends with access door complete all as specified and directed.
S&F in repair stainless steel plate rack 0.8mm thick of capacity carrying minimum 10 plates and minimum size 900mm x 600mm x 250mm deep with plate racks, spoon holder, shelves etc complete all as specified and directed
S&F in repairs stainless steel sink made out of 1.0mm thick sheet or kitchen or laboratory with plug washer pipe, cast iron cantilever brackets connecting union over all size 495x460mm with bowl 410mm x 330mm x 160mm complete all as specified and directed
S&F Stainless steel wire gauge / wire cloth of size 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with s s tacks, or s s wire staples complete all as specified and directed
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410 -W (GdeE- 250) quality A complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire complete all as specified and directed
Supply only 4mm dia galvanised steel wire,chain link any size, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed
M/L for repairing to existing aluminium doors of any size by straightening of frame / shutter, replacing the detoriated member with new, replacing the broken / non funcional hinges with new, replacing decayed rubber gasket with new, replacing the broken glass pane of any size with new 5.00mm thick tinted glass, replacing unserviceable handle, tower bolt, lock, floor spring, foundation box with governing pivot, top pivot, peg stay etc with new and including taking down and at same place after making the door / window smooth functional complete all as specified and directed.
M/L for repairing to existing aluminium window of any size by straightening of frame / shutter, replacing the detoriated member with new, replacing the broken / non funcional hinges with new, replacing decayed rubber gasket with new, replacing the broken glass pane of any size with new 5.00mm thick tinted glass, replacing unserviceable handle, tower bolt, lock, floor spring, foundation box with governing pivot, top pivot, peg stay etc with new and including taking down and at same place after making the door / window smooth functional complete all as specified and directed.
M&L Road marking paint for painting lines, dashes, arrows,letters etc on roads, pavements and like etc with thermoplastic paint 2.0mm thick ,white or golden yellow after cleaning surfaces complete all as specified and directed.
M&L for Cutting out concrete blocks, slabs, brickwork or stone masonry (in alter nate course), forming tooth-ings for and bonding new work in mortar into old work, including new materials entering old wall with neat cement slurry and PCC (1:2:4) Type B1 (using 20 mm graded crushed stone aggregate) and finishing the surface in CM (1:4) complete all as specified and direted .
S&F in repairs Vitreous China Urinal Flate back of large size 590X390X 375 mm including Waste pipe complete all as specified and direted .(Make:- Cat NO 60002 of Hindware or equivalent as approved by GE )
M&L for taking down existing roof treatement and wire brushing and cleaning top surfaces of tile or cement concrete over roof slab including flashings and junctions of parapets etc sweeping, cleaning and washing down with water etc complete all specified and directed.
M&L for rendering 20mm thick in CM (1:4) on roof surface with WPC finished the surface even and smooth without using extra cement complete all specified and directed. (NOTE:- WPC will be measured and paid seperately as "SUPPLY ONLY")
M&L for preparation of roof surfaces , applying a coat of bituminous primer @ 0.30 Kg/Sqm ,applying a coat of bitumen grade 85/25 @ 1.2 Kg/Sqm over primer , laying of modified polyermric water proofing membrane of approved make (weight not less than 3.0 Kg/Sqm) and instructions including two coat of aluminium paint complete all as specified and directed.
Supply only Integral water proofing compound complete all specified and directed. ( NOTE:- Tenderers may note that amount of credit will be deducted from the total amount arrived at the time of Acceptance of contract.)
M/S Quality Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .