Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
18 Mar 2021, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEEANDMWSCN
EEEANDMWSCN NEAR KANHIYA NAGAR METRO STATION DELHI-35
Renovation/ Electrification of Room no.106.316 at varunalaya phase-I and B building gallery and toilet and room no.120 at Varunalaya phase-II and other allied works.
2021_DJB_201438_5
NIT NO. 23 (2020-2021)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMWSCN
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
Exempted
31 Mar 2021
12 Mar 2021
18 Mar 2021
12 Mar 2021
18 Mar 2021
12 Mar 2021
120 days
Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc.as required.(DSR No.1.10.3Group C).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(DSR No.1.32)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(DSR No.1.31)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(DSR No.1.25)
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. (DSR No.1.14.2)
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2x4sq. mm+1x4sq.mm earth wire.(DSR No.1.14.3)
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 4X10sq.mm+2X6 sq.mm earth wire.(DSR No.1.14.10)
Supplying and fixing 4 way(4+12),Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board,415V,on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(DSR No.2.4.1)
Installation, testing and commissioning of pre- wired, florescent fitting/compact florescent fitting of all types, complete with all accessories and tube /lamp etc. directly on ceiling/wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.(DSR No.1.41)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.(DSR No.1.44)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450mm sweep.(DSR NO.1.50.1)
Supply and fixing call bell /buzzer suitable for single phase 230 V, complete as required.(DSR No.1.38)
Supply and fixing 5A to 32A rating, 10 KA, C, curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR No.2.10.1)
Supply of Ceiling fan 240 volt size 1200mm (make:-Crompton/ Havells/ orient).
Heavy duty Exhaust fan 300 mm. Make:-Havells/Crompton/orient.
Supply of recessed & surface LED Ceiling tile1X1 ft. 24 watt. Make:-Havells/Crompton/Vipro.
Supply of LED Batten 24 Watt. Make:-Havells/Crompton/DJB approved.
Supply of C series MCB 63 Amp. TPN 10 KA, C, curve 240/415 V,50 Hz. Make:-Havells/Standard/C&S.
S/o 15/16 Amp,3 pin Plug top ISI Mark. Make:-Havells/Anchor/Standard.
S/o 5/6 Amp,3 pin Plug top ISI Mark .Make:-Havells/Anchor/Standard.
P.K. Electricals
SHREE KRISHANA ENGINEERING
ISHIKA ASSOCIATES
Cantilever Engineers
HYDROCON ENGINEERS
Jal Dhara Engineers India
AQUA GASEOUS CONTROLS (INDIA)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .