Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹37.0 L+₹2.4 L (6.99%)Rejected-AOC | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹41.6 L+₹7.0 L (20.4%)Rejected-AOC 401 7 32 CIVIL LINES ROORKEE HARIDWAR UP 247 667 | ROORKEE | HARIDWAR | UP | 247667 | L3 | Rejected-AOC Rejected being not L1 |
Tender Value
₹42.9 L
EMD Value
₹85,800
Closing Date
18 Jun 2022, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee
SPECIAL REPAIRS TO BLDG NO P-62 MDC SEWAGE SYSTEM INSIDE GR LINES OR MD ACCN AND PROVN OF ONE VERTICAL ROPE HORIZONTAL ROPE AND CHIN UP BAR NEAR PT GROUND OF 288 MED REGT IN THE AREA OF AGE BR I UNDER GE ROORKEE
2022_MES_525552_1
8392/177/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (MES) ROORKEE
₹85,800
6 Oct 2022
21 May 2022
20 Jun 2022
21 May 2022
18 Jun 2022
4 Jun 2022
Amount
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for brick work in CM 1:4 using Sub class ‘B’ Bricks straight or curved on plan any radius in half brick complete all as specified and directed .
M & L for brick work in CM 1:6 using Sub class ‘B’ Bricks straight or curved on plan exc 6 m mean radius including demolition of Brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articlescomplete all as specified and directed.
Material and Labour for rendering 15 mm thick cement plaster in cement mortar (1:6) on fair faces faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement complete all as specified and directed.
Material and Labour for rendering 15 mm thick cement plaster in cement mortar (1:4) on fair faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of New Plaster surfaces of walls, and applying two coat of oil bound distemper over a coat of 1mm thick wall care putty, complete all as specified and directed.
M & L for preparation of New Plaster surfaces of walls, and applying two coat of cement base paint over one coat of white wash over a coat of 1mm thick wall care putty, complete all as specified and directed.
M & L for complete removal of existing treatment on walls, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl preparation of old decorated surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M & L for complete removal of existing treatment on walls, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl preparation of old decorated surfaces of walls and applying 1.00mm thick wall care putty of approved makes as on wall surfaces and two coats of oil bound distemper (White or tinted) complete all as specified and directed.
M & L for complete removal of existing treatment on ceiling, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl preparation of old decorated surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for providing PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in floor, hard standing, plinth protection etc 75 mm thick finished even and smooth without using extra cement laid in alternate bays n'exc 2.50 Sqm and joints filled with with mastic filling complete all as specified and directed.
M & L for glazed ceramic colour joint free tiles in vertical surface 450X 300X 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed.
S&F vitrified ceramic tiles double charge 10mm thick (square/ rectangular) polished, light shade, area of each tiles not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including 15mm thick screed bed in CM 1:6 including dismantling floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
M&L for providing 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate), as in sub base complete all as specified and as directed.
Demolition of reinforced cement concrete of any description in ground floors and pavings n.exc 15 cm thickness (below or above ground level) including cutting reinforcement (if required) to facilitate demolition complete all as specified and directed.
M & L for precast reinforced cement concrete type B-1 1 : 2 : 4 in landings, cover slabs for manholes, kitchen platform etc and similar articles with plain faces, with plain fair faces, including chamfers, weathering, throating etc and setting in mortar complete with joints to match set in CM 1:6 complete all as specified and directed.
M & L TMT bars 10 mm dia and over cut to length, bent to shape required incl cranking, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Taking down chowkhat with shutter n.exe 1.50 sqm (without taking off shutters) each complete all as specified and directed.
Taking down chowkhat with shutter .exe 1.50 sqm and nexe 4 sqm (without taking off shutter) each complete all as specified and directed.
M&L powder coated Anodised aluminium frame for doors, windows, ventilators, partition walls etc with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including 01 no mortice lock, necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, door stoper, hinges, mortice lock, if required, anodised aluminum snap beading screws, etc. hungs/ sliding type including particle board as required complete all as specified and directed.
S&F powder coated aluminium glazed/ guazed window and ventlators sliding/hung type as required; aluminium section weighing 0.55 kg/ m, incl necessary lock system/ tower bolts, necessary cleats glzing clips anodised, alum snap bidding screw and rubber lining at sides for air locking ,aluminium mongry and without glazing bar complete all as specified and directed.
S&F sheet glass 4 mm thick ordinary quality and glazing with neoprane beading to aluminium frame complete exc 0.5 sqm in each pane complete all as specified and directed.
S&F aluminium grill 2"x2" aparture fixed in aluminium windows complete all as specified and directed.
M & L for 600x600x4mm thick designer ceiling board as in false ceiling, colour & pattern as approved by Engr-in- charge /GE including GI frame work using main tee of size 24x38x0.5 mm and cross tee 24x28x0.5 mm made out of PGI sheet 0.30 mm thick doubled at web and single at flange. Flange covered with powder coated sheet 0.25 mm thick and angle 24 x24x0.4 mm covered with powder coated sheet 0.25 mm , thick for ceiling, suspended with GI wire 4 mm dia and upto 02 mtr long complete including plugging in brick wall/concrete surface with steel rawl plugs @ 600 mm c/c including dismantling unserviceable false ceiling complete all as specified and directed.
M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty including repairs of Mortic lock in aluminium door complete all as specifies and as directed.
M&L framed work such as grills etc with ends of bars shouldered and or riveted or forged into spike; framed guard bars and similar work conforming to Fe 410-0 0r Fe 310-0 complete all as specified and directed.
M&L in repair for 18/19 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice & other side balancing white lamination, fixed with screws to frame work as in cupboard shutters, shelves incl wooden beading at ends and sides complete all as specified and directed.
S & F Continuous (piano) hinges, Width of flaps 30mm(when open) in mild steel, bright finish or electro galvanised complete all specified and directed.
M & L for 100MM Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all specified and directed.
S & F Extruded aluminium alloy handles, 125mm long bolts fabricated type, anodised and fixed complete all as specified and directed.
M & L for fixing of magnet best quality suitable for cupboard shutters, shelfs etc complete all as specified and directed.
S&F MS framed work such as grills, gratings, hold fast etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bar, barred iron door, ladders, framed balusters, walk way, railings frame work of water tank and similar work confirming to Fe 290 Gde E165 complete all as specified and directed.
Taking down alluminium door/ window complete shutter with/ without frame as per requirement and repair to hinges (any type) / screw/frame (incl S&F hinges/pivot hinges/ screw/ rubber biding/ suiatale aluminium section if required) and fixed to frame / wall complete all as specified and as directed.
M & L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)complete all as specified and directed.
M & L for precast reinforced cement concrete type B-1 1 : 2 : 4 in landings, cover slabs for manholes, kitchen platform etc and similar articles with plain faces, with plain fair faces, including chamfers, weathering, throating etc and setting in mortar complete with joints to match set in CM 1:6 complete all as specified and directed.
M & L for reinforced cement concrete 1:2:4 Ty B-1 using 20mm graded stone aggregate (nominal mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F vitreous china wash basin , white, Oval type, size 630x450mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe fixing only in repairs complete all specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15mm bore complete all as specified and directed.
S&F PVC connection 450mm long with 2 Nos brass check nuts suitable for 15mm bore of pipe with washer complete all as specified and directed.
S&F in repair Curtain rod Aluminium coloured powder coated fancy type curtain rod 20 to 25mm dia including mild steel fancy type brackets & end caps (Knobs) matching to colour of rod, stops, in suitable size, complete all as specified and directed.
S & F in repairs towel rail 600 mm long 20 mm dia Brass chromium plated fixed to wall with CP steel screws etc, complete all as specified and directed.
S&F 15mm bore GI tubing (ISI marked), medium grade with all fittings and fixed to walls and ceilling or laid in flooring including connection etc including taking down old tubing complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as vent pipe and similar work including taking down old existing pipe complete all as specified and directed.
S&F in repair 75mm PVC (SWR) bends any radius complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm dia complete all as specified and directed.
All as per item No 50 above but 200mm dia pipe.
Excavation in trenches n.exc 1.50 m wide & n.exc 1.50 m in depth for foundation or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
Excavation in trenches n.exc 1.50 m wide & exc 1.50 m but n.exc 3 m in depth for foundation or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
Excavation in trenches n.exc 1.50 m wide & exc 3.00 m but n.exc 4.50 m in depth for foundation or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
M&L PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation of manholes, filling and mass concrete etc complete all as specified and directed
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregrate) as in bed to 150mm internal dia SGSW drain pipes including packing under and haunching against sides of pipes after they are laid and tested complete all as specified and directed by Enginner-in-Charge.
M&L for brick work with old size sub class ‘B’ bricks in cement mortar (1:4), straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for brick work with old size sub class ‘B’ bricks in cement mortar (1:4), curved to plan mean radius n.exc 6 m with bricks roughly cut to radius or bricks with wedge shape joints complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in cills, coping, bed plates, bed blocks for hold fasts, apex stones and the like with plain fair faces including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed.
M&L for precast reinforced cement concrtete (1:2:4) type B-1 (using 20mm graded stone aggregate) in manhole covers including necessary form work and fixing in postion in cement mortar (1:4) complete all as specified and directed.
S&F mild steel TMT reinforcement bars 6 mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:3) mixed with water proofing liquid on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Supply only WPC complete all as specified and directed.
M&L for SGSW drain pipe of 150 mm internal dia, grade `A', laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed by Enginner-in-Charge.
M&L for SGSW drain pipe of 200 mm internal dia, grade `A', laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed by Enginner-in-Charge.
M&L for 300mm bore reinforced concrete pipes, class NP2, laid and jointed with collars complete all as specified and directed by Enginner-in-Charge.
Returning filling in with excavated soil including spreading, leveling, watering & well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for cleaning of blocked/chocked sewer pipe line of 150 mm dia sewage line ( n.exc 3.00 m in depth from top of manholes to bottm of pipe line) by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and burrying the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers in cement mortar 1:4 complete all as specified and directed.
M&L for cleaning of blocked/chocked sewer pipe line of 200 mm dia sewage line (exc 1.50 m and n.exc 3.00 m in depth from top of manholes to bottm of pipe line) by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and burrying the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers in cement mortar 1:4 complete all as specified and directed.
M&L for cleaning of blocked/chocked sewer pipe line of 250 mm dia sewage line (exc 1.50 m and n.exc 3.00 m in depth from top of manholes to bottm of pipe line) by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and burrying the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers in cement mortar 1:4 complete all as specified and directed.
M&L PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed
M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts.posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., complete all as specified and directed.
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F 40mm bore GI tubing (ISI marked), medium grade with all fittings and fixed to walls and ceilling or in flooring complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for concealed Point wiring with 1.5 Sqmm(Nominal area) PVC insulated, unsheathed FRLS multi stranded copper conductor single core cable 1100 Volt grade drawn through and including PVC conduit of 20 mm dia ISI marked with complete accessories, including modular type galavanised iron steel sunken boxes suitable for modular type switches, sockets, also including PVC insulated and unsheathed single core multi stranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly, CONTD....
including taking down of existing point wiring and their connected fittings & fixtures like switches, sockets, Ceiling rose, fan regulator etc and making good disturbed surface with white wash or any type distemper as per existing colour of building complete all as specified and directed for the following :- Note for Point wiring:- (i) The quoted rate is deemed to be include the price of G I sunken box suitable for modular type switches, sockets etc of any module size & shape. (ii) The quoted rate is also deemed to be include the rate of cover plate, blank plate of any type and any module. (iii) The quoted rate is deemed to be included rate of dismantling of existing point of any type including fittings & fixtures complete.
One light point controlled by one, one way modular type switch complete all as specified and directed.
One Ceiling/exhaust fan point controlled by one, one way modular type switch complete all as specified and directed.
One 3/5 pin socket outlet 5/6 Amp on the same board with other modular type switches complete all as specified and directed.
One 3/5 pin 5/6 Amps modular socket outlet on independent modular board complete all as specified and directed.
One bell/buzzer point controlled by one modular type bell push button complete all as specified and directed.
All as per item No 77.00 & 77.01 above here in before but concealed wiring with 2.5 Sqmm (nominal area) multi-stranded copper conductor PVC insulated, unsheathed FRLS cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLS cable, green colour as earth continuity wire, controlled by one, one way 16 Amp modular switch complete all as specified and directed.
Supply and fix modular type white colour switch 6Amps one way, AC 230 volts in one modules complete all as specified and directed.
Supply and fix modular type white colour 6 Amp 5 pin shuttered socket, 230 volts in 2 module complete all as specified and directed.
Supply and fix modular type white colour shuttered socket 6/16 Amps 230 volts in 2 module complete all as specified and directed.
Supply and fix modular type white colour switch with indicator 16 Amps, 230 volts in 1 module complete all as specified and directed.
Supply and fix modular stepped type 4 Step Energy Saving electronic Fan Regulator suitable for 2 module, white colour AC 230 V, including connecting complete all as specified and directed.
Supply and fix modular type bell push switch in one module 10 Amp AC 230 volts complete all as specified and directed.
M&L for Ceiling rose in poly carbonate 3 terminal brass flush type 6 Amps,250 volts AC ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed.
Supply and fixing Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed.
S&F In replacement of old unserviceable light fittings LED tube light fitting 1x20 Watt industrial batten box type with bipin holders connector block complete with all accessories internally prewired and incl connecting up three core single wire incl 01 no. 20 watt retrofit LED tube rod T8 polycarbonate to be fixed at any height of wall/ceiling complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2/1 feet, 10/9 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F recess mounting light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for 600 x600 mm POP false ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and directed.
S & F Sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 4.0 sqmm LT, 1100V grade, down trhough and incl adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 4.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be include and shall not be measured separately. Earth wire shall run inside the conduit pipe including taking down old sub main wireing complete all as spd and directed. Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.
All as per item No 95 above but 6.00 Sqmm copper conductor and 6.0 Sqmm as earth continuity conductor complete all as spd and directed.
S & F in replacement of old unserviceable Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,single pole and neutral 250 volts ,flush to wall complete all as spd and directed.
S & F in replacement of old unserviceable MCBs single pole,6 to 32 Amp 240 volt C-curve 10 KA, complete all as spd and directed.
S & F In replacement of old unserviceable MCBs double pole , 40 Amp 240 volt C-curve 10 KA complete all as spd and directed.
Supply and fixing single pole and neutral metal sheet enclosure with a two pin and earth plug and socket suitable for AC connection socket complete with one single pole MCB 240V 32Amps complete all as specified and directed.
M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I CONTD....
and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) (chamber size not less than 300x300x300mm interier diamentions), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. and chamber shall be made 0.5 mtr away from the earthing pit.
Bharat Bhoomi Construction
KHANDELWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .