Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.7 LAccepted-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | ₹95.7 L Quoted ₹96.6 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.1 Cr+₹9.4 L (9.72%)Rejected-Finance GATANGA MISSION CHARALI TEZPUR 784154 ASSAM | SONITPUR | ASSAM | 784154 | ₹1.1 Cr+₹9.4 L (9.72%) | L2 | Rejected-Finance Unsuccessful bidder |
| 3 | L3₹1.1 Cr+₹15.7 L (16.3%)Rejected-Finance VILL BAREGAON PO CHAK CHAKA BAZAR DIST BARPE | BARPETA | ASSAM | 781301 | ₹1.1 Cr+₹15.7 L (16.3%) | L3 | Rejected-Finance Unsuccessful bidder |
| 4 | L4₹1.1 Cr+₹16.3 L (16.9%)Rejected-Finance | ₹1.1 Cr+₹16.3 L (16.9%) | L4 | Rejected-Finance Unsuccessful bidder |
| 5 | L5₹1.1 Cr+₹17.3 L (17.9%)Rejected-Finance | ₹1.1 Cr+₹17.3 L (17.9%) | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
19 Mar 2024, 6:00 pmClosed
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
SPL REPAIR OF OFFRS, JCOs AND OR MD ACCN BLDG NO P-200, P-128, P-137, P-141 AND P-151 AT CERTAIN UNIT UNDER GE(S) TEZPUR
2024_MES_642509_1
CWE/TEZ(S)/T-61 of 23-24
Open Tender
Civil Works
Item Rate
270 days
GE(S) Tezpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE(S) Tezpur
₹1.9 L
Yes
8 May 2024
15 Feb 2024
21 Mar 2024
15 Feb 2024
19 Mar 2024
7 Mar 2024
Amount
Taking down cement plaster on brick/concrete surfaces of walls and ceiling including racking out jointing hacking for key, scrubbing down with water etc.
Taking down chowkhats incl shutterrs (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4 sqm each .
Taking down chowkhats incl shutterrs n exc 1.5 sqm
Taking down shutter of any description exc 1 Sqm but n'exc 2 Sqm each.
Dismantling water tanks of capacity exc 500 l & not exc 1000 litres and removing to store
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for
Demolition of RCC of any description and in any position.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Hacking Out Old Broken Glass (any thickness, size, quality or description) from Wooden Frames, Glazed with Putty or fixed with Beads, complete all as specified and as directed.
S&F 750 Ltrs capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) double layer, as per IS-12701 (latest revision) hoisted and fixed in position
S&F 1000 Ltrs capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) double layer, as per IS-12701 (latest revision) hoisted and fixed in position
S&F ball valve high pressure PTMT with epoxy coatyed aluminium rod & high density plastic ball screwed for iron pipe and fixed of size 25mm bore complete all as directed at site.
S & F in repairs 15 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete as specified and directed
M&L for RCC (1:2:4) type BI as in precast slab set in CM (1:4).
M&L for R C C 1:1.5:3 (20mm gradded agg) as in roof slab supported on wall, beam , landing ,deck slab etc.
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
S&F 10mm dia and over TMT bars as in reinforcement,cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90m dia.
Taking up or down steel tubing of size 15 mm and connections
Taking up or down steel tubing of size 20 mm and connections
Taking up or down steel tubing of size 25/32 mm and connections
S&F 15mm bore medium grade galvanished steel tube with all fitting & fixed complete to walls or ceiling & laid in floors
S&F 20mm bore medium grade galvanished steel tube with all fitting & fixed complete to walls or ceiling & laid in floors
S&F 25mm bore medium grade galvanished steel tube with all fitting & fixed complete to walls or ceiling & laid in floors
S&F 32mm bore medium grade galvanished steel tube with all fitting & fixed complete to walls or ceiling & laid in floors
S & F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed
S & F 25 x 3mm F1 hold fast conforming to Fe 410-0
M/L PCC 1:3:6 type C1 20mm grade aggregate as in padding, hold fasts/filling of chowkhats or similar work as directed.
S & F 35 mm thick flush shutter , solid core construction ,with block board core and plywood face panel ,commercial type on both side.
S & F in repairs 40 mm width of flap Continuous (piano) hinges, brass, bright finish or electro galvanised complete all as specified
S/F 35mm thick factory made glazed and skeleton shutters open rebated and prepared to receive glass gauge etc. Divided into squares with plain chamfered or rounded, rebated sash bars, sizes of the members of the shutters as specified in SSR Part I, section 8, clause 8.23(a).
S & F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified Note : Size of section shall be as directed.
S & F powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, EPDM rubber gasket packing, anodised aluminium snap beading, self locking type screws etc. complete all as specified
Materials and Labour for mid steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S/F 4mm thick ordinary quality sheet glass in squares exc 0.5 sqm in each pane fixed in aluminium frame complete.
S&F steel window without glazing bars but with FI/Z section for fixing of gauze and steel handle, peg stay complete all as specified and directed by Engineer-in-Charge
S/F steel window side hung shutters including box type hinges with steel handle and steel pegs stay complete with glazing bars complete
S&F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete
S/F 3mm thick ordinary quality sheet glass in squares n.exc 0.5 sqm in each pane glazing with oil putty complete.
S & F in repair 3mm thick figured glass n exc 0.5 sqm in each pane glazing with oil putty complete
S/F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm fitted with tinned tacks or galvanised wire staples complete all as specified and as directed.
S/F in repairs Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm fitted with tinned tacles or galvanised wire staples incl taking out old unserviceable wire cloth complete all as specified and as directed.
S/F 100mm size extruded aluminum alloy handles, fabricated type, anodized.
S&F 150mm long aluminium handle, cast type, anodised
S/F 100mm long aluminum anodized barred tower bolts of extruded section.
S/F 100mm size MS butt hinges, medium weight, cold rolled.
S&F 125 mm Butt hinges medium weight cold rolled mild steel and fixed.
S&F 125 mm aluminium anodised barrel tower bolt, of extruded section and fixed in position
S/F 300mm long M.S sliding door bolt, bolt type stove enameled black with bright bolt not less than 12mm dia and including a minimum of six bolts and nuts four on bolt plate & two on staple plate.
S & F Mortice lock of brass of four levers ,vertical type, size 100 mm, complete all as specified and as directed
S & F Floor door stopper 14cm long of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in repairs in floor
S & F in repair 300mm, ordinary rat tail rod pattern door springs including roller and roller plate complete
M/L for 2 coats of synthetic enamelled paint over coat of pink primer on wooden surfaces oves 10cm width or girth including preparation of new surface.
M/L for 2 coats of synthetic enamelled paint over coat of pink primer on wooden surfaces oves 10cm width or girth including preparation of old surface.
S&F Factory Made Solid PVC moulded Door Shutter (with wood free EPS) 28 to 30mm thick (style) with 2,4, or 6 raised panel design with 2mm thick moulded prelam sheet on the front face and 2mm prelam PVC sheet on back face Complete as per direction of Engineer-in-charge, manufacturer's instruction and drawing.
S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawing complete
S&F kitchen cabinet fabricated with PVC board/sheets of depth 300mm for Overhang Kitchen Cabinet to be made as per following specification- Main Outer body/carcuss on top, bottom, LHS and RHS including shutters shall be made using 18mm thick prelaminated PVC sheet with decorative finish on one face and other face white having density not less than 600 Kg/cum complete incl lipping & lining as required. 1 x shelves shall be provided using 18mm thick plain white solid PVC board of density not less than 550 Kg/cum. Backside of main body shall be fixed with 5 mm thick PVC plain white sheet. (i) The work shall be carried out by authorised rep of the manufacturer and documents in support shall be produced by the Contractor. Manufacturing test certificate with regard to the PVC sheets used in the work shall be produced for prior approval of GE. (ii) Necessary test certificate to be produced by contractor for prior approval of GE. (iii) Drg No CWE/TEZ/57/2024 Sheet No 1/1 attached herewith shall be referred for guidance.
S&F kitchen cabinet fabricated with PVC board/sheets of depth 700mm below kitchen platform to be made as per following specification- Main Outer body/carcuss shall be made using 18mm thick prelaminated plain white solid PVC board of density not less than 500 Kg/cum on top, bottom, LHS & RHS. Backside of main body shall be fixed with 5mm thick PVC plain white sheet. 1 x shelves shall be provided using 18mm thick plain white solid PVC board of density not less than 550 Kg/cum. 18mm thick prelaminated PVC sheet with decorative finish on one face and other face white having density not less than 600 Kg/cum shall be used for shutters on front including lining and lining as required. Backside of main body shall be fixed with 5mm thick PVC plain white sheet. (i) The work shall be carried out by authorised rep of the manufacturer and documents in support shall be produced by the Contractor. Manufacturing test certificate with regard to the PVC sheets used in the work shall be produced for prior approval of GE. (ii) Necessary test certificate to be produced by contractor for prior approval of GE. (iii) Drg No CWE/TEZ/57/2024 Sheet No 1/1 attached herewith shall be referred for guidance.
M&L 10mm thick rendering in cm (1:6) on other than fair faces of brick work finished even & smooth without using extra cement.
M&L 15mm thick rendering in cm (1:4) on fair faces of brick work with using WPC @ 3% finished even & fair.
M&L 5mm thick rendering in cm (1:3) on ceiling finished even of smooth without using extra concrete.
M&L 15mm thick plastering in cement mortar 1 :3 with integral water proofing compound @ 3% by wt of cement finished even & smooth over RCC roof/slab/Chajja/Sun shade etc with out using extra cement. (water proofing compound measured & paid separately) in single storie , double storie bldg including necessary scaffolding etc including taking down existing plaster
M&L for providing, cement concrete type B0, 1:2:4 (using 12.5mm graded aggt) in haunching of chajjas, roof kerbs or mud stops, rounded or chamfered on edges complete all as directed
M&L applying two coats of distemper over a coat of primer over a coat of 3mm thick a layer of wall care putty on walls.
M&L two coats of oil bound distemper over a coat of primer over 3mm thick layer of wall care putty after complete removal of existing treatment
M&L three coats of white wash to internal wall including preparation of new surfaces.
M&L one coat of white wash over old decorative surface internal wall including preparation of new surfaces.
M&L three coats of white washing to ceiling including preparation of new surfaces.
All as per item No above but one coat over old decorative surface –ditto-
M & L for two coats of exterior emulsion antifungus paint over a coat of primer over a coat of 3 mm thick wall care putty to wall including complete including preparation of surface as specified and directed
M & L for two coats of exterior emulsion antifungus paint over a coat of primer over a coat of 3mm thick wall care putty to wall including complete including preparation after complete removal of existing treatment as specified and directed
Supply only integral water proofing compound
M&L 25 mm thick P.C.C (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in floor finished rough.
M & L Screed Bed or Bedding Layer 15mm thick in Cement Mortar 1:4 for laying Floor Finishes/Tiles, complete all as specified and as directed
M & L for Rendering or Backing Layer 10mm thick in Cement Mortar 1:3 on Walls, etc. for fixing Tiles as Skirtings, Dados,risers etc, complete all as specified and directed.
M & L for pre-polished machine cut kota stone on flooring/staircase 20-25 mm thick over cement screed bed laid and jointed with grey cement slurry mixed and with pigment to match the shade of slab including rubbing/grinding and polishing complete
All as item No 76 here-in-before but on vertical surface such as skirting, risers etc
S&F non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile 600mmx600 mm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match
S&F non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile 600mmx600 mm, in vertical surface etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match
M & L for Virified Ceramic tiles of dark shade 10 mm thick (square/ rectangular) polished, area of each tiles lot exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
All as item no 80 above, but in vertical surfaces of walls in skirting/dado
S&F non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tileexceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match
M & L for glazed ceramic wall tiles of size 450 x300 x 7 to 8mm thick set jointed in neat cement slurry and pointed with white cement to match the tiles complete in skirting/dado.
M&L Granite (of any type) 20 mm thick work (table rubbed and polished) in steps, jambs, colts, pillars; window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M & L for Granite (of any type) 20 mmwork (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1 :3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S&F in repairs 20 mm dia decorative curtain rods of MS conduit with bright finish,including decorative side domes, brackets and a minimum of 8 Nos curtain rings in per RM of length complete all as directed by Engineer In Charge.
Demolition & bracking up 75/100mm bore AC/CI/PVC pipe set in cement mortor.
S/F 110mm bore P.V.C (S.W.R) pipe, single socketed in any length with rubber ring joints fixed to walls.
S/F 75 mm bore P.V.C (S.W.R) pipe, single socketed in any length with rubber ring joints fixed to walls.
S/F 110mm bore P.V.C (S.W.R) bend
S/F 110mm bore P.V.C (S.W.R)T junction equal or unequal.
S/F 110mm bore P.V.C vent cowl
S&F 110mm bore PVC (SWR) branch piece, single `Y’ equal or un equal.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms)
S&F in repairs vitreous China squatting pan, ‘Orissa’pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including lime concrete bedding 1:2
S&F in repairs padestal type bowl and cistern for couple closet (One piece) complete make : Jaquar EWC CNS-WHT-751SS & CNS-WHT-201 or equivalent
S&F in repairs 10 lits capacity PVC low level flushing cistern including pull chain & flush pipe, connection pipe etc complete all as specified & directed.
S/F in repairs 40 mm bore P.V.C pipe including bends and unions as and when required in any length with rubber ring joints fixed in position, as directed .
Supply and fix as in repair, PVC cabinet looking mirror with inner shelves for holding bath/saving kit of size 300x450mm complete all as specified and directed
S & F in repair health faucet with 1.00 mtr tube and hook complete all as specified and directed.
S & F in repairs 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed
S&F 15mm bore long body fancy type chromium plated bib taps with crutch or butterfly handle screwed down for iron pipes.
S&F 15 mm bore stop valve fancy type chromium plated with long shank and cup (concealed type) alloy, screwed down, high pressure, with crutel or butterfly handle, screwed both ends for iron pipe or for unions.
S & F 15mm Angle Stop valves cast copper alloy,fancy type with chromium plated for iron pipe or for unions and fixed
S&F 15mm bore 125/150/200mm size type brass chromium plated shower rose, complete all as specified.
S & F CP Soap dish of size 160x 160x90mm, any type, fixed to plugs with chromium plated brass screws
S & F CP Towel Rail 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats.
S & F CP Towel Rack 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats.
S & F CP Towel Ring fixed with and including Chromium plated brass screws and wooden/plastic cleats
S&F 15mm dia Basin Mixer cast copper alloy, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks complete all as specified and as directed.
S&F in repairs pillar taps fancy type with capstan heads, chromium plated, srewed down high pressure, with or without lettered `Hot' or `Cold' with long srewed shanks and fly-nuts, screwed for iron pipe and fixed in 15 mm bore
S&F in repair wall mixer , 3 in -1 system with provision for both telephone shower and over head shower, chromium plated, fancy type, 15 mm bore complete all as specified and directed
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x160mm
S & F in repairs vitreous china wash hand basin flat back of size 550 x 400 mm including brackets CP waste coupling 32 mm and PVC waste pipe and 15mm PVC connection complete.
M & L for mass concrete filling using PCC ( 1:5:10) type E2 in sunken floor using WPC @ 3% of cement used(Note: WPC Shall be paid separately)
M & L for average 25 mm thick cement concrete 1:2:4 type B-1 using 20 mm graded aggregate with integral wpc complies with in sunken floor and bathroom area(Make Dr fixit, pedilite, fosroc or equivalent)( Note: WPC shall be paid seprately)
S & F APP base polymeric membrane minimum weighing 3kg/sqm and 3mm thick reinforced with polyester non-wove fabric (wt not less than 150gms/sqm) laid on bitumen 85/25 grade primer surface by forced application complete all as specified.
Demolition and breaking up drain pipes 150 mm dia unserviceable salt glazed stone ware drain pipes set in cement mortar all as specified and directed.
M & L Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate concrete in bed to drain pipe including packing under and haunching against the sides pipes 150 mm internal dia after they are laid joined and tested complete
M & L salt glazed stone ware drain pipes grade A 150mm dia laid in trenches and jointed as specified.
M&L for taking down of existing Roof treatment from roof and fence and covering surface of old concrete roof by picking , sweeping clena and washing down with water remove dust, etc and applying roof treatement with the following specifications: (a) Rendering 15mm th in cm (1:4) fixed with water proofing compound as per manufacturers instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plaster surfaces for 7 days by ponding water over the roof (leveling coure) (b) Applying evenly one coat of cold bituminous primer conforming to IS- 3384-1088@ 0.30 litre per sqm on th cleaned plastered surfaces (c) Applying layer of APP based polymeric membrane 3mm th (minimum) weighing 3.50 kg per sqm (reinforced with polyster non woven fabric weighing not less than 160 gms per sqm by torch application . The overlap shall not less than 100mm onn the reverse direction and 75mm longitudinal direction and sealing overlaps. (d) Applying evenly one coat of aluminium paint of 0.10 ltr sqm over APP based polymeric membrane.
S & F of Fe-410 Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete.
M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with L type J type or cranked hook bolts as specified and directed
M&L for preparation old painted surfaces of steel and iron surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M&L for preparation new surfaces of steel and iron surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Supply and fix Plate rack made out of Stainless steel sheet 1 mm thick overall size 650(H)x650(W)x250(D) including brackets or fitted with existing shelves in repair complete all as specified and directed
M&L hard core of gauge n'exc 63 mm of broken boulder below Path.
Demolition of brick work built in cement mortar including all quions, arches pillars etc. all as specified and directed.
M & L Brick work built in CM 1:4 with sub class "B"old size bricks straight or curved on plan exceeding 6 m mean radius.
M&L brick work using sub class ‘B’ bricks (old size) straight or curved on plan to any radius in half brick work built in CM 1:4 complete all as specified.
M &L PCC (1:3:6) 40 mm graded aggregate type C-2 as in drain/surface channel and similar work .
M&L 15 mm thick plastering on other than fair faces of wall surfaces in cm (1:4) finished even and smooth without using extra cement complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete with fair finished with using extra cement.
M/L 75mm thick P.C.C 1:4:8 type D-2 using 40mm graded stone aggregate finished even and smooth without using extra cementas in plinth protection/sub base/ etc complete all as specified and directed.
Forming Constrution (Dummy) joints 30 mm deep x 10 mm wide, filled with sealing compound grade A
S&F pressed steel frame of size 105x60mm for doors with one or more vebates incl necessary fixing lugs, hingers, luck strick plate etc complete as specified.
M&L for glossy finish chequered cement concrete tiles 30cm x 30cm x 22mm thick set, jointed and pointed in neat cement slurry in floors
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches,ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
Material and labour point wiring for one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables (as per approved colour) in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, ISI marked with valid CML No including metal flush box suitable for modular cover plate with frame of suitable size 1 M to 8 M and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire (green colour) and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. Note: (i) Rate deemed to be inclusive of cutting chases and making good disturbed surface). (ii) Length or wiring 12 mtrs from switch board to be considered as one point wiring. (iii) Rate of circuit wiring of min size 2.5 Sqmm from DB to switch board is included in unit rate of item. (iv) Colour code of wire for Phase, neutral and earth should be as per IE rule.
All as per item No.139 above but One 3 pin 5 Amps socket out let points on independent board
All as per item No.139 above but 5 Amp socket on same board with other switches.
All as per item No.139 above but one light point controlled by 2 Nos. 2 way switches.
M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, medum grade, ISI marked with valid CML No including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, medum grade, ISI marked with valid CML No including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
Supply and fix Modular switch one way 6 Amp, 1 Module , 230 Volts complete as directed.
Supply and fix modular switch 2 way 10 Amp, 1 Module, 230 Volts complete as directed.
Supply and fix modular bell push , flush type, 6 Amp, 1 Module, 230 Volts complete as directed.
Supply and fix Ding Dong bell, AC, 230 volts, single pole complete as directed.
Supply and fix modular socket outlet 2 in 1, 3 pin 10 A, 2 Module, 230 Volts complete as directed
Supply and fix modular socket outlet 2 in 1, 3 pin 16 Amps, 2 Module, 230 Volts complete as directed
Supply and fix Modular switch one way 16 Amp, 1 Module, 230 Volts complete as directed
Material and labour for ceiling rose polycarbonate isolated body 3 ways terminals.
Supply and fix modular step type electronic fan regulator, 120 Watt, 2 Module complete as directed Note : All modular switch sockets , celing rose, holders, fan regulators and associated acessories should be of same colour (white colour) and modular switches, socket , fan regulator and, cover plates of same make and model. Contractor shall submit the sample and take approval of Engineer in Charge before procurment.
Supply & fixing in repair lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings to be fixed on PVC box complete all as specified and directed.
Supply and fixing in repiar modular white cover plate with frame 2 modules complete all as specified and as directed.
Supply and fixing in repair modular white cover plate with frame 3 modules complete all as specified and as directed.
Supply and fixing in repair modular white cover plate with frame 4 modules complete all as specified and as directed.
Supply and fixing in repair modular white cover plate with frame 6 modules complete all as specified and as directed.
Supply and fixing in repair modular white cover plate with frame 8 modules complete all as specified and as directed.
Supply and fixing in repair modular metal flush box 2 modules complete all as specified and as directed.
Supply and fixing in repair modular metal flush box 3 modules complete all as specified and as directed.
Supply and fixing in repair modular metal flush box 4 modules complete all as specified and as directed.
Supply and fixing in repair modular metal flush box 6 modules complete all as specified and as directed.
Supply and fixing in repair modular metal flush box 8 modules complete all as specified and as directed.
Supply & fixing in repair for Modular type 25 Amps power unit combine with on/off switch complete all as specified and directed.
Supplying and fixing in repair concealed Sub main wiring with two single core (Phase + Neutral), 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit medium grade, ISI marked, in concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete incl taking down u/s wiring all as specified and directed by Engineer in charge. Note : Two run of 4 sqmm wire (Phase + Neutral) with one run of 4 sqmm earth wire and one run of PVC conduit pipe shall be measured against one unit. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
Supplying and fixing in repair concealed Sub main wiring with two single core (Phase + Neutral), 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (min 25 mm) medium grade, ISI marked, in concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete incl taking down u/s wiring all as specified and directed by Engineer in charge. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). Note : Two run of 6 sqmm wire (Phase + Neutral) with one run of 6 sqmm earth wire and one run of PVC conduit pipe shall be measured against one unit.
Supplying and fixing in repair concealed Sub main wiring with four single core (3 Phase + Neutral), 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit, min 32 mm size, medium grade, ISI marked, in concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire incl taking down u/s wiring complete all as specifiedand directed by Engineer in charge. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). Note : Four run of 6 sqmm wire with one run of 6 sqmm earth wire and one run of PVC conduit pipe of min size 32 mm shall be measured against one unit.
Supply and fixed in repair 18 W LED light fitting wall mounted batten 4'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt, 6500K including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed complete all as specified and directed.
Supply and fixed in repair 10 W LED light fitting wall mounted batten 2'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 10 watt, 6500K including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directedconnection complete all as specified and directed.
Supply and fixed in repair security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
Supply and fixed in repair 12 W Surface panel mounted round LED downlight, aesthetically designed aluminium die-cast enclousers, with seperate replaceable constant current driver 12 watts, including necessary connection complete all as specified and directed.
Supply & fix in replacement of LED bulb 15 watt 6500 k complete all as specified and as directed.
Supply and fixing in repair LED decorative wall light made up of high grade engineering plastic material suitable for LED 20W complete as per manufacturer's instructions all as specified and directed.
S & F in repair DB box in sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cable management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing incl taking down u/s with all as specified and directed by Engr-in-charge. Note : (i) MCB and DB box shall be of same make.
S & F in repair DB Box in sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 12 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cable management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing, incl taking down u/s all as specified and directed by Engr-in-charge. Note : (i) MCB and DB box shall be of same make.
S&F in repair DB Box, in sheet metal enclosure VT DB TPN, MCB DB TPN 4 way, double door MCB as incomer (Vertical type double door),suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 200 Amp copper bus bar for each phase, with Neutralbar, Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, providing blanking plate on vacant outlet way including flushing and fixing DB box in neaty in wall complete incl taking down u/s all as specified and directed by Engr-in-charge. Note : (i) MCB and DB box shall be of same make.
Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts, ISI marked, as per IEC 60898-1 2002 and to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fixed in repairs MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts , ISI marked, as per IEC 60898-1 2002 and to be housed in DBs complete including necessry connection all as specified and directed.
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts, ISI marked, as per IEC 60898-1 2002 and to be housed in DBs complete including necessry connection all as specified and directed.
Taking down of AC ceiling / exhaust fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan, providing new nut bolts, split lock pin, rubber bush for hanging celing fan as directed by the Engr-in-Charge.
Taking down existing Geyser of any size and make upto 25 ltrs carefully, by diconnecting electrical and water pipe line connection and deposite at MES Yard/store for refixing.
Refixing of existing Geyser 25 ltrs as taking down under above item by making all electrical connection and water pipe line connection complete all as directed by Engineer in charge.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note : Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM)
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the IRC specifications shall be followed. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule "A" notes for details.
M/S MOHANPASARI
M/s DEBOJIT ROY
Sibson Constructions And Co
Chinmay Traders
MAKBUL HUSSAIN LLP
PURBANCHAL BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .