Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.6 Cr+₹17.7 L (12.4%)Admitted-Finance | ₹1.6 Cr+₹17.7 L (12.4%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Joshi Enterprises L1 | Saklani electrical works L2 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C | 524 | Point | 664 ₹3,47,936 Lowest | 753 ₹3,94,572 |
| 2.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell poin.t with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed medium class PVC conduit, and with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C | 602 | Point | 520 ₹3,13,040 Lowest | 589 ₹3,54,578 |
| 3.00 | Wiring for twin control light point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable etc. as required. | 9 | Point | 712 ₹6,408 Lowest | 807 ₹7,263 |
| 4.00 | Wiring for light/ power plug with 2X4 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required (for power plug and A.C.s). | 1,350 | Metre | 150 ₹2,02,500 Lowest | 170 ₹2,29,500 |
| 5.00 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (for power plug and A.C.s). | 900 | Metre | 119 ₹1,07,100 Lowest | 135 ₹1,21,500 |
| 6.00 | Wiring for light/ power plug with 4X4 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required (for Power Plugs). | 300 | Metre | 2 ₹600 Lowest | 288 ₹86,400 |
| 7.00Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required | |||||
| 7.01 | 2x1.5 sqmm+1x1.5 sqmm earth wire (CKT wiring + wiring for light plugs) | 3,300 | Metre | 120 ₹3,96,000 Lowest | 180 ₹5,94,000 |
| 7.02 | 2x6 sqmm+1x6 sqmm earth wire | 150 | Metre | 204 ₹30,600 Lowest | 232 ₹34,800 |
| 7.03 | 4x6 sqmm+2x6 sqmm earth wire | 100 | Metre | 360 ₹36,000 Lowest | 408 ₹40,800 |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
5 Apr 2021, 3:00 pmClosed
DGM HQ
Head Office Avasthapna Bhavan, 583-TH, Oppo. Govt ITI, Niranjanpur, Majra Saharanpur Road, Dehradun-248001
Balance Electrification work at Administrative and Academic Building for IHM Ramnagar Distt. Nainital
2021_BRID2_31463_1
508/BRIDCUL/721/2021 Dated 19.03.2021
Open Tender
Electrical Works
Item Rate
365 days
RAMNAGAR NAINITAL
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹2.9 L
BRIDCUL DEHRADUN
12 Apr 2021
23 Mar 2021
5 Apr 2021
23 Mar 2021
5 Apr 2021
31 Mar 2021
30 Mar 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell poin.t with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed medium class PVC conduit, and with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required (for power plug and A.C.s).
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (for power plug and A.C.s).
Wiring for light/ power plug with 4X4 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required (for Power Plugs).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2x1.5 sqmm+1x1.5 sqmm earth wire (CKT wiring + wiring for light plugs)
2x6 sqmm+1x6 sqmm earth wire
4x6 sqmm+2x6 sqmm earth wire
4x10 sqmm+2x10 sqmm earth wire
4x16 sqmm+2x16 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC conduit as required.
2x1.5 sqmm+1x1.5 sqmm earth wire in existing conduit
2x6 sqmm+1x6 sqmm earth wire in existing conduit
4x6 sqmm+2x6 sqmm earth wire in existing conduit
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5sqmm (for computer electrical supply)
Supplying and drawing following pair, 0.5sqmm FR PVC insulated copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25 mm (for LAN cable / telephone wire / elect. Supply for computer)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
200 mm x 300 mm x 60 mm deep (in elect.ducts)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Telephone socket outlet
Bell push
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmx75mm) (for telephone / LAN supply)
6 Module (200mmX75mm) (for computer elect. Supply)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6A modular socket outlet and 5/6A modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan / fresh air fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep / wall fan
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2+12 way / 14 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4+12), Double door
6 way (4+18), Double door
8 way (4+24), Double door
Supplying and fixing 5A to 32A rating, 240/415V, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole (32A)
Triple pole and neutral (32A)
Supplying and fixing 20A, 240V, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30A, 415V, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200mmx150mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm widthx50 mm depthx1.6 mm thickness
450 mm widthx50 mm depthx2.0 mm thickness
600 mm widthx50 mm depthx2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm widthx50 mm depthx1.6 mm thickness
450 mm widthx50 mm depthx2.0 mm thickness
600 mm widthx50 mm depthx2.0 mm thickness
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600mmx600mmx6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600mmx600mmx3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection FRLS om earth electrode with 6 SWG dia G.I. Wire in 15mm dia G.I. pipe FRLSom earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mmx5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mmx5 mm copper strip on surface for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sqmm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½x25 sqmm (28mm)
3½x35 sqmm (32mm)
3½x50 sqmm (35mm)
3½x70 sqmm (38mm)
3½x95 sqmm (45mm)
4x16 sqmm (28mm)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 100 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Design & casting of foundation with M20 cement concrete & steel reinforcement suitable for installation of 7m octagonal pole.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drawings (not exceeding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
All kinds of soil (size 0.7m x 0.7m x 1.65m = 0.81cum (18 nos. X 0.81cum + 0.5) (for flood light) = 15.08cum
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutterin - All work upto plinth level.
1:5:10 (Cement : Lime Sand : Graded stone aggregate 40mm nominal size) (18Nos. X 0.049 =0.88)+ 0.06 (for flood light) = 0.94cum
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars) 2 vertical bars 12mm dia = 4nos. X 1.55 = 6.5rmt @0.89kg per mtr = 5.52kg 3Horizontal Ring 8mm dia =11nos. X 2 = 22 rmt @0.39kg per mtr = 8.56kg Total (5.52 + 8.58 = 14.1 + 5% = 14.8 Wastage = 18nos x 14.81 = 266.58)
Reinforced cement concrete work in walls (any thickness), including attached plsters, buttresses, plingth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. Centering, shuttering, finishing and reinforcement.
1:1:5:3 (cement : coarse sand : graded stone aggregate 20mm nominal size) Size 0.5x0.5x1.55 = 0.388 cum Total (18nos. X 0.388 = 3.49 cum) + 0.4 = 7.38cum
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, fottings, basses of columns, etc. For mass concrete Size 0.5x0.5x1.55 = 0.388 cum Total (18nos. X 3.88 = 34.92 cum) + 0.4 = 70.24cum
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm x 200 mm, made mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm x 5 mm G.I. strip on surface or inrecess for connections etc. as required.
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 120 sqmm
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ x 95sqmm (45mm)
3½ x 300sqmm (70mm)
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
S/I/T/C of fancy wall bracket of shape design as approved by architect including cost of lamp and erection of the same on wall with cost of screws etc.
Fancy wall light single bracket Philips make model 30897/43
fancy mirror light Crompton Make Cat. No. LCL-10-CDL
Supply and carriage of surface mounting LED Batten fitting 1x 18 watt, (4 feet long), made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230 Volts, 50 HZ supply, complete in all respect. (Philips make TMC501 1x TLED18W or its equivalent Wipro / Crompton make only).
Supply and carriage of surface mounting LED Batten fitting 2x 18 watt, (4 feet long), made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230 Volts, 50 HZ supply, complete in all respect. (Philips make Baton TMC501 P2xT-LTD 22W P3241 or its equivalent Wipro / Crompton make only).
Supply and carriage of surface mounting LED Panel fitting 36watt size 4'x1' Crompton make cat. No. (Aura 2) LC PL - 36 - CDL / TL (1x4) or its equivalent Philips / Wipro make).
Supply and carriage of 12W LED 1'x1' fitting surface mounted Crompton make LCDSPL S-12 CDL or its equivalent Wipro / GE.
Supply and erection of 36W - 38W LED 2'x2' fitting recess mounted (Philips make (Sereno) RC 380 B LED 30-6500 PSU OD WH or its equivalent Crompton / Wipro make only). The job is includes cutting of false to fix the fitting and making connection to the nearest point with copper wires.
Supply and erection of Foot Lights NXC101 1xa60-60WCL Philips make or its equivalent Crompton/Wipro). The job includes the fixing of fitting in wall and cost of lamp, making connection to the nearest point with copper wires and all petty material required. .
Supply and carriage of A.C. ceiling fan double ball bearing complete in all respect with fan regulator. The fan should consume less power (Havell's / Usha / Crompton make only).
Size 48" sweep (1200mm)
Supply and Carriage of Fresh air fan 250mm complete with guard. The fresh fan fan is to be fixed in ventilator with 12mm thick wooden board after making hole in board. The board is to be fixed screws etc. including painting of board with matching colour of fresh air fan. The job includes connection from nearest light point with PVC Cu wire including cost of all material (Havell's / Usha / Khaitan make).
Fresh Air fan 250mm
Supply and carriage of 380mm sweep A.C. Exhaust fan (ISI Marked Havell's / Chrompton / Bajaj make) suitable for single phase A.C. 230 Volts, 50 HZ capacitor, 900 RPM (Heavy Duty) complete with mounting ring frame with four fixing holes and automatic louver shutter but without regulator. The exhaust fan is to be fixed in the existing glazing with suitable MS frame of required thickness as per site including its painting etc. as per site requirement.
S/I/T/C of LED street light light fitting in 6800 lumens & 70W / 72W power consumption Philips make Cat. No. BRP 410 LED CW072 MRFG S1 PSU GR or its equivalent Wipro / GE make complete in all respect. The fitting is to be fixed on existing bracket mounted on 8m high pole. The job includes cost of fitting, wiring connection etc. required to complete the job.
Supply, carriage and erection of 7m long hot dipped galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm complete with the base plate of minimum size 200mm x 200mm x 12mm alongwith inbuilt lockable in box operated with single key with connectors of Elmax make for the cable termination and two or three terminals and one no. 6A SP MCB for each luminaire. The diameter across from the dimensions of the base and top should be minimum 130mm and 70mm A/F (Across face). The size of the poles and foundation bolts shall be suitable to withstand the maximum wind speed / pressure as per IS-875.
There should be no any circumferential welding on pole. The method and material shall comply with as BSEN-10025 grade S355 or equivalent poles should be not dipped galvanized in single dip to 65 microns min. confirming to IS 2629-1966. The street light poles shall be erected in the existing RCC foundation with 4Nos. special founation bolts 'J' type minimum 700mm long galvanized MS rod of duly threaded of minimum 20mm dia in existing RCC foundation of suitable size as per the approved drawing. The material of steel foundation belts shall be confirming to grae EN-8 exposed threaded portion of foundation bolts shall be not dipped galvanized. The make of ple shall be BPP / Bajaj / Surya / Philips as approved by the Engineer-in-charge of work
Supply, fabrication and erection of GI (B-class) ISI marked Jindal make street light bracket 2" dia 0.9m overhang L shaped with angle of inclination 1050 and lower side of 80mm GI pipe 0.45m long slipped over the pole fixed with 2 Nos. 12mm dia nut-bolts. The top end of the 80mm GI pipe is to be covered with 2mm thick MS sheet and conical MS sheet 3mm thick is to be welded between 2" and 3" GI pipe to give mechanical strength. The job includes cost of all abovesaid material including painting of all MS parts.
Single arm bracket
Double arm bracket
S/I/T/C of LED flood light fitting in 10700 lumens & 105W power consumption P107W LED floor light Philips make BVP 410 LED 107C W HENV FG S3 XT or its equivalent Wipro / GE make complete in all respect. The fitting is to be fixed on existing bracket mounted on 8m high pole. The job includes cost of fitting, wiring connection etc. required to complete the job.
Supply and erection of PVC junction box Hensel make size 200x160mm with openable cover and 2 nos. clamps and 4 Nos. terminals. A kit-kat 16A 240V is also to be provided in box. The box is to be fixed along existing wall with provision of incoming and outgoing cables. The job includes cost of all material and labour required.
Supply, erection, testing and commissioning with electronic time switch suitable for 3 Phase system comprising of 1 No. timer clock with battery 1 No. ML-3 contactor of L&T / BCH / Indoasian make, bypass toggle switch, MCB fuse and complete wiring with PVC copper wire. The time switch sheet and enclosed in 16G sheet MS enclosure with front hinged cover. The time switch is to be fixed on existing MS frame of outdoor pedestal with nut-bolts and making connections to street lighting circuit with cost of PVC copper wire of required size.
Supply and erection of modular type 25A Switch with indication and 25A Socket with modular box and sheet complete in all respect (Legrand/North-west /Crabtree /MK make). The box is to be recessed in wall complete with cost of petty material required to fix the same and labour involved.
Supply and erection of MCCB / MCB 4/3/2pole in the existing enclosure including making connections.
MCCB 63A 3pole 25kA capacity
MCCB 100A 3pole 35kA capacity
MCCB 125A 3pole 35kA capacity
Supply and erection of sheet metal enclosure suitable for 4way MCB / MCB TPN. The enclosure is to be fit in the existing electric niche with suitable screws etc.
Supplying, fabrication and installation testing and commissioning of triple pole and neutral copper busbar in sheet steel enclosure of 16G with top cover suitable for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply and of following rating, complete with cost of copper strips suitable to take full load current fixed on insulators in the busbar enclosure. The busbar is to be painted with 2 coats of paint after primer coat. The busbar is to be fixed on existing wall with anchor fasteners complete with cost of all petty material required.
100 amps TPN busbar 2 feet long
Supply, fabrication and carriage of cubical type panel compartmentalized fabricated out of 14G CRCA sheet with internal member of 16G complete with erection of incoming and outgoing switchgear, supply and erection of busbars meters, indicators, cable end boxes as required. The panel shall be either floor standing type or wall mounted as per drawing and site. The panel shall be totally enclosed dust and vermin proof construction with square sections rubber gaskets. The floor mounted panels shall be strictly as per specifications. The busbar will be wrought aluminium E91E grade suitable for 50KA fault level for one second (The fabricator will have to give manufacturer's certificate of E91E grade wrought aluminium busbar). All four busbars should be insulated with colour should PVC heat shrinkable sleeves.
The panel should be complete as per the drawing and includes all internal wiring with PVC copper cable of requisite size complete with name plates of each feeder, danger plate, solid bus connections, cable alleys, busbar chamber etc. including cost of LT CT electronic three phase energy meter with their CTs and all connections. and other petty material The panel will be powder coated after chemical treatment. The degree of protection panel should be IP54 and should be extendable on both sides. All MCCBs are to be provided with extended rotary handles, spreaders and Phase Barriers for proper termination of cables. All MCBs are to be 'C' series except for capacitor bank which are to be 'D' series.
MAIN LT Panel (In LT Room)
INCOMER
630A 4P MCCB with thermal magnetic release 35KA = 1No.
S/E of Bus bar 800A TPN with GI strip electrolytic grade with DMC insulators and heat shrink sleeve with extendable provision to connect to second future panel = 1No.
OUTGOING
320A TP MCCB 36KA = 1 No.
200A TP MCCB 36KA = 2 No.
100A TP MCCB 25KA = 3 No.
63A TP MCCB 25KA = 6 No.
MAIN DG Panel (In LT Room)
INCOMER
400 A 4P MCCB with thermal magnetic release 35KA = 1No.
400 A 4P ON load change over switch = 1 No.
S/E of Bus bar 500A TPN with GI strip electrolytic grade with DMC insulators and heat shrink sleeve with extendable provision to connect to second future panel = 1No.
OUTGOING
200 A TP MCCB 36KA = 1 No.
125A TP MCCB 36KA = 1 No.
100A TP MCCB 25KA = 3 No.
63A TP MCCB 25KA = 3 No.
63A 4P MCB 10KA = 5 No.
32A 4P MCB 10KA = 2 No.
Elect.Duct-1 NS GFL
INCOMER
100A 4P MCCB with thermal magnetic release 25KA = 1No.
OUTGOING
100A 3P MCCB with thermal magnetic release 25KA = 1No.
63A 4P MCCB 25KA = 1Nos.
63A 4P MCB 10KA = 3Nos.
Elect.Duct-2 NS GFL
INCOMER
200A 4P MCCB with thermal magnetic release 35KA = 1No.
OUTGOING
125A 3P MCCB with thermal magnetic release 25KA = 1No.
100A 3P MCCB with thermal magnetic release 25KA = 1No.
63A 4P MCCB 25KA = 2Nos.
Elect.Duct-4 NS GFL
INCOMER
200A 4P MCCB with thermal magnetic release 35KA = 1No.
OUTGOING
100A 3P MCCB with thermal magnetic release 25KA = 4No.
Supply & carriage of LT cables 1.1KV grade, aluminium LT XLPE armoured ISI marked of approved make as per following sizes.
3.5x300 mm2 LT XLPE Al Conductor Cable
3.5x95 mm2 LT XLPE Al Conductor Cable
3.5x70 mm2 LT XLPE Al Conductor Cable
3.5x50 mm2 LT XLPE Al Conductor Cable
3.5x35 mm2 LT XLPE Al Conductor Cable
3.5x25 mm2 LT XLPE Al Conductor Cable
4x16 mm2 LT PVC Al Conductor Cable
4x6 mm2 LT PVC Al Conductor Cable
Supply and erection of PVC Copper cables 4Core flexible 1100V grade PVC insulated and PVC sheathed as per IS694-1990. The cable is to be laid in existing tray / duct fixed with suitable clamps as per site requirements including their cost. The cable should be as per brand list attached.
25 Sqmm 4Core
Supply and laying of 16sqmm single core copper conductor cable in 25mm dia PVC conduit for bonding to earth for computer rooms. The pipe is to be laid in ground/floor/wall as per site requirement complete with cost of pipe / bend / socket / thimbles etc. required to complete the job.
Supplying and laying of the following sizes of DWC pipe of reputed make complete with bend, socket etc. to be laid 2feet below ground level after excavating the earth / RCC floor and covering the pipe with dug out earth and repairing the floor etc. as per site requirements.
120/103.5mm dia
63/50mm dia
Supply and laying of GI earth strip of size 50x5mm hot dipped from earth to panel / transformer. The strip is to be laid in ground / on surface as per site requirement including termination.
Supply and erection silent genset 160KVA for 415V 3phase A/C supply complete with Engine water cooled turbochared afted cooled complete with alternator, control panel, accoustic enclosure, exhust pipe upto required height including its insulation, fuel tank and battery charger with battery complete in all respect. The accoustic enclosure should be able to reduce the sound level to 70-75db at a distance of 3m. The enclosure should be anti-corrosive duly powder coated / Epoxy paint and have enough space to house panel and fuel tank inside it include cost of panel and fuel tank. The cost of first filling of fuel in the tank and fuel used in testing is also included in it. The job also includes S/E/T/C of Automatic Main Failure Panel suitable for 160 KVA DG set fabricated out of CRCA steel 14/16 SWG sheet totally enclosed dust, damp and vermin proof, free standing, floor mounted type and front operated with antivibrating pads. The panel structure shall be of cubical from in suitbale sections, with sheet steel work. All doors and joints will be suitable gasketed to form dust and vermin proof. The panel would be powder coatd to minimum thickness of 50 microns. The cubical will have stove enameled paint finished after elaborate pre-treatments to form a long lasting characteristic. The Control Panel will be complete in all respects with fuses, wiring and labels etc. and such will be ready for operating when reaches the site.
Following instruments and equipments will be incorporated in the AMF panel :
Contactor for Mains = 1 No.
Contactor for Alternator = 1 No.
Under Voltage Relay for mains = 1 No.
Three attempt engine start Relay = 1 No.
On delay timer for load change over = 1 No.
On delay timer for engine shut off = 1 No.
Enginer Cranking Relay = 1 No.
Battery charger consisting of transformer, rectifier, choke for boost and trickle charging arrangement = 1 No.
Metering
Digital Frequency meter
DC Voltmeter and Ammeter for Battery charger
Set of Indicator Lamps - 1 No.
Engine fail to start
Batter Charger ON
Load on Mains
Load on DG Set
Auxilliary contators / Relays for circuitary requiremens = 1Set
Push Button = 1 Set
Acknowledge / reset / test for fault failure
For manual operation of DG set
For test of DG set
One set of Busbars for interconnection of incomer, feeder and load
Two set of HRC fuses for two incomers
AMF Operation
Automatic Start / Stop in case of Mains failure / restore
Alternator Protection
Under / Over Voltage
Under Frequency
Short Circuit
Over Load
Reverse Power
Over Current
Speed / Frequency Mismatch
Loss of Excitation
Phase Rotation
Digital Display of Electrical Parameter
Current in 3 Phases
Voltage in L-N & L-L
Parallel Bus Voltage [3 Phase, line-to-line]
Power Factor
Kilowatt
Kilowatt Hour Energy
Frequency
Analog Meters
KW Meter
Frequency Meter
AC Voltmeter
AC Ammeter
Supply, fabrication and carriage of cubical type panel compartmentalized fabricated out of 14G CRCA sheet with internal member of 16G complete with erection of incoming and outgoing switchgear, supply and erection of busbars meters, indicators, cable end boxes as required. The panel shall be either floor standing type or wall mounted as per drawing and site. The panel shall be totally enclosed dust and vermin proof construction with square sections rubber gaskets. The floor mounted panels shall be strictly as per specifications. The busbar will be wrought aluminium E91E grade suitable for 50KA fault level for one second (The fabricator will have to give manufacturer's certificate of E91E grade wrought aluminium busbar). All four busbars should be insulated with colour should PVC heat shrinkable sleeves. The panel should be complete as per the drawing and includes all internal wiring with PVC copper cable of requisite size complete with name plates of each feeder, danger plate, solid bus connections, cable alleys, busbar chamber etc.
and other petty material The panel will be powder coated after chemical treatment. The degree of protection panel should be IP54 and should be extendable on both sides. All MCCBs are to be provided with extended rotary handles and spreaders for proper termination of cables. All MCBs are to be 'C' series
MAIN PCC (in Sub Station)
INCOMER
1250A 4P ACB microprocessor based suitable for 415V 50Hz AC manualy draw out type with 6.A Rel i.e. O/L, S/C & E/F Prot. + Safety Shutter (Inbuilt), Control MCB, Neutral Links = 1 No. (as Incomer).
S/E of Bus bar 1500A TPN with GI strip electrolytic grade with DMC insulators and heat shrink sleeve with extendable provision to connect to second future panel = 1No.
OUTGOING
630A TP MCCB 36KA = 1 No.
400A TP MCCB 36KA = 1 No.
320A TP MCCB 36KA = 1 No.
250A TP MCCB 36KA = 4 No.
100A TP MCCB 25KA = 1 No.
Supply, carriage and erection of standard APFC panel for 175KVAR complete in all respect enclosed in cubical panel floor mounted complete with MCCB, contactors, capacitor APFC relay, indicators, wiring and other required accessories of L&T make etaSYS - MIH1 or its equivalent of Siemens make having capacitor bank of 2x50 + 2x25 + 2x12.5.
Supply, installation, testing and commissioning of outdoor two pole 11KV HT structure as per State electricity board specifications of 9m Height complete with following equipment inter connections and all hardware, consumables, welding rods etc.
400A, 11KV, 3Phase GOD with GI operating rod & handle with padlocking arrangement = 1 Nos..
11KV, dropout fuse mounting complete with 200A DO fuses, 200A fuse holders etc.=1 set of 3 Nos.
Two pole structure of PCC pole comprising of 2Nos. 9m high poles to accommodate the equipments mentioned above complete with supply and erection of MS channels, MS angle iron, strip, flat etc. required to fix the abovesaid material as per state electricity board requirement. The work has to be executed as per drawing and specifications and directions of consultant. This shall include interconnection with electricity board 2 pole structure for supply of power (upto a distance of 5mtrs) complete as per state electricity board requirements.
Supply and erection of dry type 11KV CT/PT metering panel of ratio 50/5-5A consisting of trivector meter (L&T make) (suitable for 750KVA 11kv transfomer) having accuracy class 0.5 and burden 15VA PT with voltage ratio 11KV/110V, 3Phase having burden 100VA per phase for 3phase 4 wire system with 11KV energy meter (L&T make) and conforming to relevant ISS and as per state electricity board specifications and requirements complete enclosed in 14/16G CRCA sheet enclosure including making all the necessary connections to the satisfaction of Engineer-in-charge.
S / I /T / C of 11 KV HT VCB Panel comprising of 1 No incoming cum outgoing VCB panel Normal system Voltage 630 Amp for incoming Highest system Voltage, 630 Amp for outgoing feeders, 50 HZ rated frequency, 3phase, 3 wire,350 MVA at 11 KV rated continuous current rating at ambient temperature as specified in IS: 13118-199175kV peak) . The 11 kV Switchgear panel shall comprise of 11 kV Vacuum Type circuit breaker, control relay panels, instrument panel and instrument Transformers complete in all respect etc. suitable for indoor use. The equipment shall be totally enclosed, single bus bar, floor mounting metal clad, indoor extensible type, flush fronted horizontal drawout vertical isolation type vacuum circuit breaker,cubicle, dust and vermin proof with necessary isolation arrangement. Panel shall be easily extensible on either side and should be complete with necessary copper connections, small wiring, fuses, and framework with bolts to secure it to the floor & panel shall be provided with heater, door switch with lamps and 15-Ampere power receptacle.
1. Standards
The Switchgear panels shall comply in all respects the requirement as laid down in the latest editions of IS-3427, IS-3231, IS:2705, IS: 3156 & IS- 13118-1991
2. Climatic conditions:
The equipment is required to operate satisfactorily under the following conditions:
Max .Ambiant Température: 50°C
Min. Ambiant Température: -2°C
Max. Relative humidity: 100 %
Min. Relative humidity: 26%
Average no. of rainy days per annum: Nearly 120 days
Average annual rainfall: 900 mm
Average number of dust storm days per annum: 35
Max. Wind pressure: 19kg/Sq.mt
3. Type and ratings:
The breakers shall have the following ratings:
Type: 11kV
No. of .poles: 3
Normal system Voltage 800 Amp for incoming
Highest system Voltage 630 Amp for outgoing feeders
Rated frequency 350 MVA Rated continuous current rating at ambient temperature as specified in IS: 13118-199175kV (Peak)
Symmetrical breaking capacity 28kV (rms)
Microprocessor based protective relays shall contain all protections as necessary for safe operation of VCB such as over current, earth fault, and short circuit etc. shall be provided.
Master Trip Relay, Trip Supervision Relay,
Impulse with stand test voltage: Not less than 18.4 kA for 1 Second
General design of Switchgear Panel Operating mechanism:
Power Pack 220 V AC
The VCB shall be trip free and the breaker control shall be draw out type. The VCBs shall be suitable for operation from 220 V AC. The operating mechanism shall be motor operated spring charged type & there shall be provisions for manual charging of closing spring and emergency hand trip. The motor used for the purpose will be suitable for 220 V AC.The operating mechanism shall work satisfactorily at 85 -110 % of rated supply voltage.
Supply erection testing and commissioning of 750KVA 11/0.433KV distribution transformer outdoor type oil immersed (Crompton / Reychem / Sudhir / Voltamp / Siemens make), natural cooled having following specifications confirming to IS 2026 latest.
Rate Supply frequency -50Hz per second
No. of phases - 3
No. of winding - 2
Winding connection - Primary Delta, Secondary star with fully insulated neutral brought out to secondary terminals.
Material of Winding - Copper wound
Voltage taps - OFF load taps on primary for ± 5% in steps of 2.5%
Primary side connections- Suitable for XLPE 11KV cable with cable end box
Secondary side connections - Suitable for 4 No. three phase (3.5C) LT cable with cable end box
Buchholz Relay with shut off valve
Under carriage - Suitable under carriage with rollers with edges designed so as to permit sliding without damaging the floor and 2 Nos. lifting lugs.
Marshalling box - To facilitate connections of all protection devices like oil temp. indicator etc.
Fitting & Accessories - As per IS specifications, such as filica get breather, conservator, bare-bushing for HT & LT sides, 2 Nos. earthing terminals, explosion vent drain valve, with plug including first filling of oil, Radiator, oil temperature indicator with A/T contacts etc. The transformer is to be erected on existing platform and making all incoming & outgoing connections including control wiring. The job includes cost of transformer & painting of all MS parts & as per HVPNL terms.
Supply & laying of 12mm thick and 1 mtr wide rubbermat for panel board.
Supply & fixing shock treatment charts in Hindi and English language in LT rooms of Sub-stations with wooden frame and glass frame.
Supply of first Aid Box complete with first fill of medicines as per IE rules
Supply and erection of 1 set of 3 nos. fire buckets of 9 ltr capacity each complete with MS stand made of 50x50x6mm angle iron including painting complete and buckets filled with sand.
Supply & laying of 3C x 95sqmm HT XLPE cables 11KV (E) grade aluminium conductor armoured ISI marked of approved make as per following sizes. The cable to be laid 1m deep after excavating the earth and covered with sand and bricks as per CPWD specifications. The scope includes supply & laying of cable including cost of sand bricks and labour required for excavation, carriage of cable and other petty material required to complete the job.
Supply and laying of GI earth strip of size 50x5mm hot dipped from earth to panel / transformer. The strip is to be laid in ground / on surface as per site requirement including termination.
Saklani electrical works
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
SBDIHM.pdf
Tender Documents • 1.84 MB
BOQ_37300.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .