Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC CHANGANACHERRY GENERAL ELECTRICAL WORK | ERNAKULAM | KERALA | 682001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹48.2 L+₹1.9 L (4.01%)Rejected-AOC | L2 | Rejected-AOC Second Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
6 Feb 2024, 5:00 pmClosed
Executive Engineer
O/O The Executive Engineer PWD Electrical division Thrissur
GENERAL Construction of Building for District Homeo Hospital Kakkanad Phase IV Balance work Electrification General Electrical Work
2024_PWD_642518_2
PWD/BLDG/12666/2023-2024
Open Tender
Electrical Works
Item Rate
180 days
Kakkanad
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,760
₹50,000
2 Apr 2024
30 Jan 2024
8 Feb 2024
30 Jan 2024
6 Feb 2024
30 Jan 2024
Amount
ELECTRIFICATION
OD106842/2023-2024:Supply, conveyance, installation, testing and commissioning of 160 K.V.A Indoor type unitized sub station comprising of H.T.panel trunked with cast resin Transformer with top entry cable box as per technical details furnished below. H.T. Side: (1) 1 No 11K.V, 630A Load break switch suitable for 3 phase,3wire,50 Hz system with suitable H.R.C. fuses of appropriate rating with earth inter lock with main switch and mechanical ON/OFF indication, shunt trip coil for the remote operation of the the load break switch, 2. TOD meter facility :a)3 Nos -/5A ,0.2S class accuracy,15VA cast resin CT(or as suggested by KSEBL), b)1 NO 3 phase 3 limb 11KV/110V ,100VA ,0.2 class cast resin PT with protective fuses c)1 No 3 phase 4 wire 11KV/110V,/5A 0.2 S class TOD meter (or as suggested by KSEBL) Transformer Portion consists of 160 K.V.A , 11 K.V, 50 Hz, Delta/Star connected cast resin copper wound transformer. The core shall be of laser scribed & Class 'F' insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap position of +5% to -10 % in steps of 2.5%. .Emergency push button with trip mechanism is to be provided. The transformer shall confirm to IS . All inter connection from HT load break switch to transformer and to LT breaker shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contacts, 250A microprocecer based MCCB at LT side with EFR & NCT and required indicators and meters. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclosure shall be powder coated over suitable primer after seven tank processing. The TOD meter compartment and CT/PT unit compartment shall be fabricated so as to enable the KSEBL authority to seal it. The USS shall be installed as per the directions at site.
OD106844/2023-2024:Supply, Conveyance, Installation, testing and Commissioning of 125 KVA DG set with standard accessories as per technical details given below on :- i. Engine a. Make of Engine : As per Specified in the List of Materials b. Type of Engine : Diesel Engine c. No. of Cylinders : Suitable to develop the required BHP as per manufacturers standard d. Method of Cooling: Water Cooling (with radiator) e. Aspiration : Tubro charged after cooled f. Design : Suitable for generator set application g. Output : BHP ratings specified by the respective manufacturers capable of delivering the required power for alternator. ii. Standard accessories with Diesel Engine a. Flywheel housing and flywheel to suit single bearing alternator (Close coupled arrangement) b. Air Cleaner c. Coolant Kit d. Fuel Pump e. Electronic governor with solid state potentiometer accepting digital pulse input from PLC(backed with mechanical governor supplied as standard with the set by the manufacturer) f. Fuel filter g. Lubricating Oil filter h. Residential type exhaust silencer iii. Engine Instrument Panel a. Starting switch with key or button b. Lubricating oil temperature gauge c. Lubricating oil pressure gauge Water temperature gauge e. RPM Indicator with hour meter f. Battery charging ammeter iv. Safety Controls for Engine a. Trip for low lubricating oil pressure b. Trip for high water temperature c. Providing necessary warning system and other safeties as contemplated in relevant ISS d. Fuel shunt off facility at over speed. iv. Fuel Pipe: Oil resistant flexible hoses & 25mm dial or nearest size MS pipe as per manufacturers requirement for fuel line extension with regulator valve. v. Alternator a. Make : As per Specified in the List of Materials . b. Type : Self exited and self regulated c. Capacity : 125 KVA at 0.8PF d. System of Voltage : 3phase, 415V e. Speed : 1500rpm f. Voltage regulation band : +1.00% of rated voltage g. Insulation : Class F/H h. AVR : AVR shall be provided with a motorized or solid state potentiometer. i. IP rating of enclosure : IP 23 j. Waveform distortion : No load < 1.5%, non- distorting, balanced Linear load <5% k. Telephone interference : Better than 50 l. Total harmonic factor : Better than 2% Standard control panel with suitably rated MCCB .m.12V,15A Automatic Battery charger suitable for 180Ah Battery, having . Full protection against battery overcharging & reverse polarity. Over voltage, overload & short circuit protection, reverse battery protection The alternator should confirm to IS 4722. Routine tests as per relevant ISS shall be conducted and test reports of the same shall be furnished at the time of delivery. vii. Fuel tank. Integral type fuel tank of adequate capacity viii. Battery: Required number of suitably rated fully charged battery with leads and terminals as required as per manufacturers requirement. ix Operation manual, service manual, list of spares etc x. Acoustic Enclosure with CPCB Norms a. The DG set shall be supplied along with specially designed, company fabricated (to be fabricated in the same company from where the DG set is delivered) acoustic enclosure to meet the CPCB norms of 75dBA @1m at 75%load under free field conditions. b. Sufficient space and clearance shall be maintained inside the enclosure to have optimum serviceability. c. Air inlet louvers shall be designed in such a way as to operate the set at rated load even at 50 degree Celsius enclosure temperature. d. The enclosure shall be with UV resistant powder coating capable to withstand extreme environment. e. Hardware used shall be of only stainless steel make. f. Insulation material shall conform to IS 8183 specifications for better attenuation. xi. Documents to be supplied. a. Engine manual. b. Spares parts book c. Warranty certificate d. Alternator manual & test certificate 1 set control wiring drawing xii. Installation It shall be installed in the pre-constructed concrete bed complying to relevant IS standards, IE rules and as per the direction of the departmental officials. xiii. Testing and Commissioning: xiv. During the 3 year Guarantee period comprehensive maintenance (excluding oil changes) and services as per manufacture recommendation and repairs shall be arranged from date of commissioning
OD189466/2023-2024:Providing and fixing following capacity Enclosed Automatic Transfer Switch (ATS) ( L&T make cat no-CK90163BSOO) , making connections, etc. as required. 200 Amp,415v,50Hz,4 pole AC
OD185295/2023-2024:Supply and filling of Diesel for Generator
OD185299/2023-2024:Charges for conducting load test of 125kva DG set at standardized factory bed as per standard norms and condition .ie in various steps load upto full load for 3 hours & 10% over load for 20 minutes and the rate includes hire and rent of test bed ,equipments, labour charge, loading and unloading and fuel etc
OD106845/2023-2024:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments
OD106846/2023-2024:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.12.13:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation200/174 mm or nearest size
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
OD106847/2023-2024:Supply and providing following size B class GI pipe with specials and flanged coupling in each full length of pipe, as additional exhaust piping, fixing the same firmly to the building/structure using necessary supports, such angle iron, MS clamp etc. Painting the pipe and accessories with synthetic enamel paint over a coat of zychromate primer etc as required 100 mm dia
OD106848/2023-2024: Supply and providing plate earthing with 1200x1200x12mm GI earth plate,50 mm GI(medium class) watering pipe,GI funnel with weld mesh,25x5 mm GI clamps,CI/MS cover plate with locking arrangements,charcoal/coke and salt etc including providing brick work masonry enclosure at the top (450x450x450mm inside)etc as required.
OD106849/2023-2024:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm tinned copper strip.
OD106850/2023-2024:Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
90.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip
OD106851/2023-2024:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 12 x 3 mm brass bolt & nut
OD106852/2023-2024:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 25 x 3mm brass bolt & nut
OD106853/2023-2024:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 30 x 10 mm Gi bolt & nut
OD106854/2023-2024:Supplying, threading, laying and jointing of the following sizes of 'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads. 40 mm dia
90.16.3.10:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm copper strip
90.16.4.9:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 6 mm copper strip
4.1.14:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 75 mm depth X 2.0 mm thickness
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD106855/2023-2024:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
90.14.24.68:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.71:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.74:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
OD106856/2023-2024:Supply & fixing the3 Pole Capacitor duty contactors for switching capacitor banks 7.5 - 10 kVAR with AC Coil,
OD106857/2023-2024:Supply & fixing the3 Pole Capacitor duty contractors for switching capacitor banks 20 kVAR with AC Coil
OD106858/2023-2024:Supply & fixing the3 Pole Capacitor duty contactors for switching capacitor banks 4 - 7 kVAR with AC Coil
OD106859/2023-2024:Supply and providing 8 stage 440 / 110 V 5A/1A , Intelligent Power Factor Controllers (IPFC)
OD106860/2023-2024:Supply and providing Panel mounting fresh air fan150 mm as required
OD106861/2023-2024:Supply and fixing Digital Multifunction meter to read: V, A, F, PF-3 phase accuracy class 0.5
OD106862/2023-2024:Supplying and fixing LED indicators for all Voltage ranges- Blue Colour
OD106863/2023-2024:Supplying and fixing LED indicators for all Voltage ranges- Red Green Black Yellow or Orange Colour
OD205943/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.5 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD205944/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.5 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD205955/2023-2024:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 2.5 sq mm with factory made clamp
OD205958/2023-2024:Supply, laying and clamping of 1 no. 2.5 sqmm 8 core PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE with the cables, spacing of clamps with factory made clamp not exceeding 60cms, making good the damages , colour washing etc. as required.
OD106865/2023-2024:Supply and fixing 150/5 A, 5VA, accuracy class 0.5, Tape wound Metering CT
OD106866/2023-2024:Providing and fixing Danger notice board 250x200mm enamelled in existing panel and giving connection complete
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
OD106867/2023-2024:Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required
OD205463/2023-2024:Supply ,installation,testing and commissioning of 700lm pressure die cast housing Bulk head with IP65 protection & IK 08 having efficacy not less than 105lm/W and giving connection with 3 core flex wire as required
OD106868/2023-2024:Supply, conveyance, installation , testing and commissioning of 225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
OD106869/2023-2024:Supply, conveyance, installation , testing and commissioning of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
OD106871/2023-2024:Supply and fixing shades of the following types of shades on existing batten / pendent/bracket fittings as required. 200 mm polished aluminium shade.
OD106872/2023-2024:Supply and providing the following types and power rated lamps in the existing fittings as required. B22 LED bulb 9W
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.8:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.10:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16A -100A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.14:MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.1.5:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG)
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
OD177188/2023-2024:250/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG)
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
OD206439/2023-2024: Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the outdoor cat walk plat form.
OD206491/2023-2024: Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required. 2.5 cm, 4 cm, 5 cm height
OD206501/2023-2024:72 OD23518/2023-2024 Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
OD206514/2023-2024: Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD206410/2023-2024: Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD106880/2023-2024:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
OD106881/2023-2024:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
LIGHTNING ARREASTER
OD106883/2023-2024:Providing and fixing of fully solid 3m Vertical Air terminal made up of Semi-hard (E-AlMgSiO5), 16mm rod tapered to 10mm. Cape-VAT 4
OD106884/2023-2024:Providing and fixing of fully solid 4m Vertical Air terminal made up of Semi-hard (E-AlMgSiO5), 16mm rod tapered to 10mm. Cape-VAT 4
OD106885/2023-2024:Providing and fixing of Interception Tip made up of Semi-hard (E-AlMgSiO5) to provide on the top of Vertical Air Terminal.Cape-ITVAT
OD106886/2023-2024:Providing and fixing of Stainless Steel SS 304 Wall Clamp to mount Vertical Air Terminal. Cape-WC 16 SS
OD106887/2023-2024:"Providing & fixing of Horizontal air terminal conductor (8mm solid aluminium alloy round conductor) made up of Semi-hard (E-AlMgSiO5). Cape-SRC 8-AL "
OD106888/2023-2024:Providing & fixing of Down conductor (8mm solid aluminium alloy round conductor) made up of Semi-hard (E-AlMgSiO5). Cape-SRC 8-AL
OD106889/2023-2024:Providing & fixing of whether resistant Nylon Parapet Conductor Holder for fixing horizontal air terminal & down conductors. The conductor holder has to fixed using fischer and SS Screws. Cape-PCH 8 including the Price of SS Screws + fischer including contractor margin
OD106890/2023-2024:Providing & fixing of Terrace Conductor Fibre Reinforce Concrete holder for fixing horizontal air terminal. Cape - MBPCH8
OD106891/2023-2024:Providing Adhesion glue for fixing terrace Conductor Fibre Reinforce Concrete holder. Cape - Adhesion Glue
OD106892/2023-2024:Providing and fixing of Aluminium Alloy Ferrule T Connector to avoid bimetallic corossion. Crimping has to be done minimum in 9 points for strong bonding. Cape-CJT 8
OD106893/2023-2024:Providing and fixing of Stainless Steel Clamping Shoe. Cape-CS 8-10
OD106894/2023-2024:Providing and fixing of Aluminium Alloy Expansion Piece to auto adjust climatic variations. Cape-EPC 8
OD106895/2023-2024:Providing and fixing of Aluminium Alloy Ferrule Straight Connector for Expansion Piece joints and other straight joints to avoid bimetallic corossion. Crimping has to be done minimum in 4 points for strong bonding. Cape-CJ 8
OD106896/2023-2024:Providing and fixing of Stainless Steel SS 304 Test Joint. The 8mm & 10mm Conductor has to be straightly connected to avoid risk of flash over and needs to have disconnection facility to measure values during testing. Minimum 4 screw/bolt joints required for strong bonding. Cape-TJR
OD106897/2023-2024:Providing and fixing of Outdoor Glass Fibre Reinforced Polycarbonate Enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm. Cape-Abox I 40
OD106898/2023-2024:Surge Protection Devices for Main Panel Building For Hospital Building ( Three Phase): DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 with Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 260KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV withstand for 120 Min : 442 V and with out Follow Current & Leakage Current in suitable enclossure
OD106899/2023-2024:Providing and laying copper coated steel solid round conductor 10mm diameter with copper coating thickness of 100microns for laying conductor after test link and for ring earthing at a depth of 0.5 meters from ground level. Needs to be routed inside heavy duty 20mm PVC pipe after test link @ a height of 2.5 meters from ground level. Cape- SRC 10-CU
OD106900/2023-2024:Supply of 20mm Heavy Duty PVC Pipe + 20mm Quick Clip including contractor margin
OD106901/2023-2024:Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor.
OD106902/2023-2024:Supply and installation of petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm for underground joints. Cape CT 5
OD106903/2023-2024:Providing and fixing of Stainless Steel SS 304 Earth Rod Connection Point to insert 10mm Copper bonded steel to 20mm Copper Bonded rod. The Connection has to be strongly bonded using strong bolt. Cape-CPES 10
OD106904/2023-2024:Providing and fixing of 1m earth rod (with 20mm diameter and copper bonding thickness of minimum 250 microns) with exothermically welded clamp on the top as per NBC 2016. Cape-CBR 2003 with Clamp
OD106905/2023-2024:Providing and fixing of 1m earth rod (with 20mm diameter and copper bonding thickness of minimum 250 microns) with with bore and peg arrangement. Cape-CBR 2003
OD106906/2023-2024:Providing and fixing of Impact Point for easy insertion of earth rod to soil. Cape-IP
OD106907/2023-2024:Providing Earth Enhancing Mineral Compund (12.5kg) for improving earth soil conductivity. It should be pollution free and hazardous substances and chemically inert. Resistivity of the compound has to less than or equal to 0.2 ohm meter. Cape-PRO SAN 12.5
OD106908/2023-2024:Providing Earth Enhancing Mineral Compund (5kg) for improving earth soil conductivity. It should be pollution free and hazardous substances and chemically inert. Resistivity of the compound has to less than or equal to 0.2 ohm meter. Cape-PRO SAN 5
OD106909/2023-2024:Supply and installation of Concrete Earth Electrode Inspection Chamber minimum dimenssion has to be 320x320x190mm. Cape-CEC 320
Kittu Electricals private limited
Bidder Name
Kittu Electricals private limited
ELCON ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1003003.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .