| # | Company | Status |
|---|---|---|
| 1 | Admitted-PreQual/Technical | Admitted-PreQual/Technical |
| 2 | Admitted-PreQual/Technical 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | Admitted-PreQual/Technical |
| 3 | Admitted-PreQual/Technical 464 465 SURESH NAGAR THATIPUR GWALIOR MADHYA PRADESH 474011 | GWALIOR | MADHYA PRADESH | 474011 | Admitted-PreQual/Technical |
| 4 | Admitted-PreQual/Technical 434 ALAGAPURAM POST PERUMAL MALAI ADIVARAM SALEM 636004 | SALEM | SALEM | TAMIL NADU | 636004 | Admitted-PreQual/Technical |
| 5 | Admitted-PreQual/Technical A 1526 27 GREEN FIELDS COLONY FARIDABAD HARYANA 121 001 | FARIDABAD | FARIDABAD | HARYANA | 121001 | Admitted-PreQual/Technical |
Tender Value
₹64.4 Cr
EMD Value
₹1.3 Cr
Closing Date
17 Jan 2026, 5:10 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CGM(S and P) MPPKVVCL Jabalpur
CGM(S and P) MPPKVVCL Jabalpur
ENGAGEMENT OF A SYSTEM INTEGRATOR (SI) FOR IMPLEMENTATION UPGRADATION OF SCADA, ITS INTEGRATION WITH OTHER SYSTEMS, AND ASSOCIATED WORKS FOR JABALPUR CITY AT MPPKVVCL, JABALPUR UNDER RDSS
2025_PKVVC_462900_3
TS 1639 ENGAGEMENT OF A SYSTEM INTEGRATOR SCADA
Open Tender
Miscellaneous Services
Item Rate
1825 days
CGM(S and P) MPPKVVCL Jabalpur
As per TS
3 documents required · 3 mandatory
₹11,800
Yes
₹1.3 Cr
Yes
12 May 2026
12 Jan 2026
19 Jan 2026
12 Jan 2026
17 Jan 2026
12 Jan 2026
Engagement of an Agency
Form: 1- Project Management Cost
Form: 2- SCADA/DMS Control Centre Cost
Form: 3-SCADA/ Disaster Recovery Control Cost
FORM-4 Substation scada equipment
FORM 5 FRTU
FORM 6 Communication system
Form 7 AUX POWER SUPPLY
Form 8: RMU/SECTIONLIZER/FPI/ETC
Form 9: Training
Form 10: FMS
Name of the Bidder/ Bidding Firm / Company :
Form: 1- Project Management Cost
Installation, Testing and Commissioning Cost to Integrate Entire SCADA & IT (relevant to SCADA) Infrastructure
Integration with legacy applications & Data Migration
Total 1+2
Bidder shall specify make & model of proposed items by adding two columns by utility in price proposal between column : equipment” and Column “ Unit” in all forms Form 2 -10
Sum of cost of FMS/year shall match with FMS cost indicated /year in Form 10 . Bidder shall ensure the same.
Cost of basic unit price of RTU in Form 11 and basic unit price FRTU in Form 12 comprising of panel , rack , DI,DO,AI , CPU ,PS , COMM card shall match with Form 4 (row 1) & Form 5 (row1 )
Bidder may club functions in common server as per their architecture. Indicative quantity is given in Table 9 of Chapter 19. However , they shall mention the same in remark in Form about the same . However, bidder shall be solely responsible for meeting CONFIGURATIONAL ,FUNCTIONAL, PERMFROMANCE , SECURITY AND SLA requirement as per SBD .Bidder shall provide hardware and software
Name of the Bidder/ Bidding Firm / Company :
FORM 2 SCADA/DMS Control Centre Cost
SCADA Server
DMS Server
OMS Server
FEP server with interface switches
ISR server
NMS server
DTS server
Developmental server
Commnuication Server
Web/Directory server
SMS gaterway
Workstation with dual TFT Monitors (S/S monitoring)
Workstation with dual TFT Monitors (Network monitoring)
Developmental console with one TFT
DTS/Workstation Console with dual TFTs
DLP based Video Projection system with 2x4 Module configuration with each module at least 67" diagonal with common projector
Storage & Backup Devices
External RAID Mass storage device (for 24 months online backup)
External DAT drive
Switches
Layer II switch (SCADA/DMS LAN)
Layer II switch (Planning & Development system LAN)
Routers
Router for interfacing IT system & SCADA/DMS DR centre
Security system (DMZ)
Web server with load balancing
Router
Firewall & network IDS/IPS
Layer II switch
Other Active Devices
GPS Time synchronisation system
Time, day & date digital displays
Printers
Color inkjet printer
B/W Laser printer
Any other items required to meet functional /Performance requirement as per MTS
Sub-Total A (Hardware)
SCADA software
ISR Software
DMS software
OMS Software
DTS software
Developmental software
Network Management Software
WEB /Network security software
RDBMS package
GIS Adaptor/Engine for importing data from GIS system under IT system
Web Enablement
Mobile Application S/W
Anti-Virus S/W
Any other software to meet functional /performance requirement of MTS:
Sub-Total -B2 (Software)
Mandatory spares
Sub -Total C spares
Grand Total = A+B+C
Name of the Bidder/ Bidding Firm / Company :
SCADA/ Disaster Recovery Control Cost
SCADA Server
DMS Server
OMS Server
FEP server with interface switches
ISR server
NMS server
DTS server
Other Active Devices
Developmental server
Commnuication Server
Web/Directory server
SMS gateway
Workstation with dual TFT Monitors (S/S monitoring)
Workstation with dual TFT Monitors (Network monitoring)
Developmental console with one TFT
DTS/Workstation Console with dual TFTs
Storage & Backup Devices
External RAID Mass storage device (for 24 months online backup)
Exteranl DAT drive
Switches
Layer II switch (SCADA/DMS LAN)
Layer II switch (Planning & Development system LAN)
Routers
Router for interfacing IT system & SCADA/DMS DR centre
Security system (DMZ)
Web server with load balancing
Router
Firewall & network IDS/IPS
Layer II switch
Other Active Devices
GPS Time synchronisation system
Time, day & date digital displays
Printers
Color inkjet printer
B/W Laser printer
Any other items required to meet functional /Performance requirement as per MTS
Sub-Total A1 Hardware
SCADA software
ISR Software
DMS software
OMS Software
DTS software
Developmental software
Network Management Software
WEB /Network security software
RDBMS package
GIS Adaptor/Engine for importing data from GIS system under IT system
Any other software to meet functional /performance requirement of MTS
Sub-Total A2 Software
Mandatory spares
Sub -Total A3 spares
Grand Total A1+A2+A3
Name of the Bidder/ Bidding Firm / Company :
FORM-4 Substation scada equipment
RTU base equipment comprising panels, racks, sub-racks, Power Supply modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi
Multifunctuions transducers
Contact Multiplying Relays (CMRs)
Heavy duty relays for Control
Dummy Breaker Latching Relays
Single TFT PC for LDMS
Weather transducer - wind speed
Weather transducer - rainfall
Weather transducer - Humidity
Weather transducer -Temperature
Weather transducer -Wind Direction
DC voltage Transducers
Any other hardware to meet functional /performance requirement of MTS
Sub - Total (Hardware) -A
LDMS software
Any other software to meet functional /performance requirement of MTS
Sub - Total (SOFTWARE) -B
RTU Database Configuration & Maintenance Software tool
Master Station cum RTU Simulator & Protocol analyser software tool
Laptop PC for above software tools along with interfacing hardware including Hub
Sub - Total (test equipment) -C
Sub - Total (mandatory spare) -D
Grand total A+B+C+D
Name of the Bidder/ Bidding Firm / Company :
form 5:- FRTU
Mini pole mounted FRTU base equipment along with enclosure suitable to work in open environment (Adequate protection from water & dust) , racks, sub-racks, Power Supply modules with power backup , I/o modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi
Contact Multiplying Relays (CMRs)
Heavy duty relays for Control
Multifunction trnasducer
Any other hardware to meet functional /performance requirement of MTS
Sub- Total A
FRTU Database Configuration & Maintenance Software tool
Master Station cum FRTU Simulator & Protocol analyser software tool
Laptop PC for above software tools along with interfacing hardware including Hub
Sub-Total B
5% of above F1
Sub-Total A3
Grand Total (A1+A2+A3)
Name of the Bidder/ Bidding Firm / Company :
Form 6 communication
2 MBPS MPLS VPN LINK FOR CONNECTIVITY OF S/S WITH SCADA CONTROL CENTER
Router/ Switch for RTU communication with CC
MPLS BW charges at SCADA Master Data Center for (30 MBPS)
ILL at SCADA Master Data Center 20 MBPS
Any other hardware to meet functional /performance requirement of MTS
Sub-Total A
Modems (4G/5G DUAL SIM)
4G /5G SIM charges (SECURED GPRS)
Any other hardware to meet functional /performance requirement of MTS
Sub-Total C
5% of above A
Sub-Total A3
Grand Total (A+A2+A3)
Name of the Bidder/ Bidding Firm / Company :
FORM 7 AUX POWER SUPPLY
UPS with suitable rating running in parallel redundant mode*
VRLA type Battery banks for above UPS for minimum 30 min. backup duration
Sub - Total A (1+2)
UPS with suitable rating running in parallel redundant mode*
VRLA type Battery banks for above UPS for minimum 30 min. backup duration
Sub - Total B (1+2)
48V DC POWER SUPPLY SYSTEM BASED ON SMPS FOR RTU & COMM. EQUIPMENT WITH 80AH BATTRY
2KVA UPS (FOR LDMS) WITH 160 AH, 72 V Battery set
Sub - Total B (1+2)
5% of above A TO C
Sub-Total D
Grand Total (A+B+C+D)
Name of the Bidder/ Bidding Firm / Company :
11 KV SF6, Motorized, SCADA Compatible RMU 1 Iso+1 Br (2way)
11 KV SF6, Motorized, SCADA Compatible RMU 2 Iso+1 Br (3way)
11 KV SF6, Motorized, SCADA Compatible RMU 2 Iso+2 Br (4way)
Foundation for placement of RMU.
End termination & heat shrinkable jointing kit with lugs for 3X 300 sq.mm 33 KV XLPE Cable kit
Outdoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 300 sq mm for RMU
11 KV 300 sq. Mm. 3 core XLPE cable
Sub-Total A (Hardware)
11 KV SECTIONALISER
11KV AUTORECLOSURE
Sub-Total A (Hardware)
11 KV STAND ALONE FAULT PASSAGE INDICATOR COMPLETE WITH GPRS ENABLED MODEM (SCADA COMPATIBLE)
Sub-Total A (Hardware)
Control /power cable
Unarmoured copper control cable 2.5 sqmm 2 core
Unarmoured copper power cable 0.5 sqmm 2 core
Unarmoured copper control cable 2.5 sqmm 4 core
SHEILD CABLE FROM CONTROL PANEL TO RTU PANEL (17 core*1.5sqmm)
Numerical relay
Master Trip relay (Aux relay (30v DC 4 NO + 4 NC))
Sub-Total A5
Mandatory spares
Sub -Total A4 spares
Grand Total = A1+A2+A3+A5
Name of the Bidder/ Bidding Firm / Company :
Form 9: TRAINING
Description
Operator for SCADA/DMS Control Centre
Instructor for DTS
Computer Hardware & System Software
Application Software (SCADA/DMS)
RTU & FRTU
Database & display development
Auxiliary Power Supply
Communication System including NMS
Total Cost
Name of the Bidder/ Bidding Firm / Company :
Form 10: FMS
FMS charges for SCADA/ DMS system (maintaining overall system availability as per TS)
FMS charges for SCADA/DMS system (maintaining availability individual hardware & software application as per TS)
FMS for Legancy System (RTU ,FRTU and associated equipments )
Total FMS charges Five Year
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.21 MB
Tenderdocument16393rdtime.pdf
Tender Documents • 22.36 MB
BOQ_558519.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .