| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC KANDATHIL VEEDU VALAKODE P O PUNALUR | PUNALUR | KOLLAM | KERALA | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.9 L+₹80,480 (4.71%)Rejected-AOC PANNAVAM ADINADU SOUTH KATHIKADAVU PO KARUNAGAPPALLY KOLLAM | KOLLAM | KOLLAM | KERALA | L2 | Rejected-AOC L2 |
Tender Value
₹20.7 L
EMD Value
₹50,000
Closing Date
11 May 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
KWA, PH Division, Kottarakkara
Deposit work- Punalur Municipality- Extension of pipe lines in various places of Bharanikkavu ward in PUNALUR Municipality
2023_KWA_574474_1
WRD/KWA-CE(SR)/TR/1407/9
Open Tender
Civil Works - Water Works
Item Rate
90 days
Punalur Municipality - Bharanikkavu Ward
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,760
Yes
₹50,000
16 Jun 2023
3 May 2023
12 May 2023
3 May 2023
11 May 2023
3 May 2023
Amount
EXTENSION OF PIPE LINES IN VARIOUS PLACES OF BHARANIKAVU WARD IN PUNALUR MUNICIPALITY
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.3:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 3m but not exceeding 4.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
100.98.222:Supply of PVC Pipe, 8kg/cm2, 75mm Dia.
100.98.223:Supply of PVC Pipe, 8kg/cm2, 90mm Dia.
100.98.226:Supply of PVC Pipe, 8kg/cm2, 160mm Dia.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD228541/2022-2023:Shifting the existing dismantled water supply service connections/ tap connections from old line to the new line by supplying and providing saddle piece of adequate size, 20 mm full way valve, 20mm nipples, 20 mm unions, 20 mm ASTM pipes, 20 mm elbows and all other specials needed and connecting to the existing consumer
OD228542/2022-2023:Interconnection work from the newly laid line to the existing lines
PRASANNAKUMAR.R
Bidder Name
PRASANNAKUMAR.R
VARGHESE CHACKO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_848085.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .