| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L1 | Accepted-AOC Lowest Bidder, hence accepted | |
| 2 | L2₹13.7 L+₹1.9 L (16.0%)Rejected-AOC 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L2 | Rejected-AOC Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹13.8 L+₹2.0 L (16.9%)Rejected-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-AOC Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹15.7 L+₹3.8 L (32.5%)Rejected-AOC 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-AOC Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
22 Jul 2021, 6:00 pmClosed
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
REPAIR/MAINT OF SECURITY LIGHTS, HIGH MAST LIGHTS AT TECH AND DOMESTIC AREA AT AF STN PHALODI
2021_MES_454294_1
8345/A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AF STN PHALODI
All contractors enlisted with MES in Class E and above and category b(i) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority. -
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹30,000
Yes
9 Sept 2021
24 Jun 2021
29 Jul 2021
24 Jun 2021
22 Jul 2021
10 Jul 2021
24 Jun 2021 - 5 Jul 2021
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in hard/dense soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose or hard dense soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line, making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type B1 complete all as specified and directed.
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with & including necessary angle iron support, clamp, nut , bolts etc and including taking down old unserviceable cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 6.10 & 6.20 :- Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ.
Cross Sectional area of cable 10 Sqmm, 4 core
Cross Sectional area of cable 10 Sqmm, 2 core
M & L for dry tibba sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover to cable all as per standard schedule rates Part-I (2009) complete all as specified and directed. Note:- Thickness after punning shall be considered for payment.
Supplying and laying in renewal of un-reinforced precast cement concrete cable cover, Class LV, Type-I, flat, size 250 mm x 150mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
M & L for PVC insulated and sheathed weather proof flat two core cable of size 2.5 Sqmm single strand aluminium conductor for connection and confirming to latest IS, ISI marked & including taking down old unserviceable cable complete all as specified and directed.
M & L for PVC insulated and sheathed weather proof flat two core cable of size 4 Sqmm single strand aluminium conductor for connection and confirming to latest IS, ISI marked & including taking down old unserviceable cable complete all as specified and directed.
M & L for PVC insulated and sheathed weather proof flat two core cable of size 6 Sqmm single strand aluminium conductor for connection and confirming to latest IS, ISI marked & including taking down old unserviceable cable complete all as specified and directed.
Supply and fixing in renewal of garden lights with LED landscape luminaires 10 Watts pressure die cost powder coated housing with PC diffuser, efficient high output COB for garden, Pathway lightining, IP 66 protection and including with all accessories & incl connecting with twin core copper conductor FR-LSH cable size as per existing etc complete all as specified and directed. Note :- Earth work, PCC Foundation etc shall be measured and paid separately under respective items of this BOQ.
Supply and fixing in renewal of 35 Watt LED Post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection and including with all accessories & incl connecting with twin core copper conductor FR-LSH cable size as per existing etc complete all as specified and directed.
S & F in renewal of MCCB, four pole, 415 Volts, 100 Amp, ultimate breaking capacity 16 KA, Ics = 100% lcu, 50 Hz, confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and magnetic release complete all as specified and directed.
Supply and fixing in renewal of reflection tape (tape colour shall be as directed by Engr-in-charge) in altternate coloured (04 Step) of width 6" on LT/HT poles between 1.5 to 1.8 Mtr above the ground level complete all as directed.
Supply and fixing in renewal of Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Astronomical time switch, high voltage and low voltage protection, 3 pole/230V for 12 KW load equally distributed over 3 phases, minimum IP-54 degree of protection complete all as specified and directed.
Supply and fixing in renewal of Flood light luminaire of HPSV/MH with LED Floodlight fitting consist of PDC aluminium houseing in powder coated die costing powder coated in grey finish, high power LED with die cast body with heat resistant tempered glass having IP 66 protection level with and including 5 kV surge protection of 150 Watts LED complete all as specified and directed.
Supply and fixing in renewal of Flood light luminaire of HPSV/MH with LED Floodlight fitting consist of PDC aluminium houseing in powder coated die costing powder coated in grey finish, high power LED with die cast body with heat resistant tempered glass having IP 66 protection level with and including 5 kV surge protection of 120 Watts LED complete all as specified and directed.
Material and labour in renewal of circuit main wiring for junction box to street light fitting with 1.5 sqmm 3 core PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial cable 1100 V grade and drawn through PVC conduit in street light poles with and including fixing arrangement and disconnection of street light fittings and refixing the same complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for connection to street light fittings etc shall be deemed to be included in the unit rate quoted.
S & F in renewal of LT cable junction box outdoor shall be made out of polycarbonate with glass fiber reinforced and size should be not less than 225mm X 295mm X 122 mm (upto cable size 35/50 Sqmm) and polycarbonate junction box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The junction box shall be rated for degree of ingress protection IP 66/69 in accordance with IEC 60529, weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be polyurethane and the gasket shall be internally embedded. The junction box shall be complies with requirements of the standards IEC 60998-1, IEC 60670-22 & IEC 60670-2-5. The junction box with connectors or terminal Trip or bus bar. The manufacturer of junction box/enclosure shall submit a copy of IEC certificate, for better safety the polycarbonate enclosure and shall be fire retardant & self -extingguishing in accordance with IEC 60695-2-11, DIN VDE 0304 Part-3, UL subject 94 for flammability V-2. It should be tested at glow wire test for 960 degree centigrade & current carrying capacity upto 102 Amps. The impact strength of polycarbonate enclosure/boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 including one No 4 pole connector and incl one no MCB SP 'B' curved 6-32 Amp and chromium plated clamps and nut bolts, Glands as per manufacturer's instructions complete all as specified and directed.
Supply and fixing in renewal of Solar batteries for Solar Street Lights of rating 12 V, 200 Ah, with conatainer and lids made of Polypropylene Co Polymer with positive plate of tubular low antimony and negative plate flat pasted with Ah effciency of above 90% and Wh efficiency above 80% complete all as specified and directed.
Disconnecting the electric supply from existing solar panel, dismantling and taking down solar PV Module of solar assembly and open up for cleaning, dismantling and servicing complete fittings system and check the all mechanism/electrical assembly housed on pole, checking of battery and battery charging circuit and if battery found fully discharged, it has to be fully charged fro market and re-assembling the all electricaly/ mechanism parts and testing on completion complete all as specified and directed. Note :- Renewal of items /spares such as wire, fuse, welding if required nuts, bolts & washers shall be deemed to be included in the above item.
Supply and fixing in renewal of Solar Street Light - Luminary of wattege 30 W LED, with epoxy powder coated pressure die-cast aluminium housing with weather proof gasket and heat resistant toughened clear glass cover fixed with SS screw with in-built charge controller and auto switch from dusk to dawn operation with ingress protection IP:65 and suitable for side entery bracket of 20-30 MM OD complete all as specified and directed.
Supply, installation, testing and commissioning in renewal of Lithium based Solar LED Security light System with built in Battery and PV Panel and LED lamp in FRP/Aluminium body and including taking down of old unserviceable light fitting of any size/capacity complete system comprises followings :- (i) PV Panel 30 W Monocrystalline. (ii) Lithium Cell for back up Min15.4AH with inbuilt BMS. (iii) High brightness W-LED lamp Min 16W, CRI>700, CCT6500K. (iv) Microcontroller based charge controller cum driver with automatic dimming function, Dusk to Dawn Operation. (v) Working temperature: (-) 10°C to (+) 55°C. (vi) System shall be supplied with adjustable MS clamp and 40mm dia arm suitable for pole/wall mounting complete with satisfaction of Engineer-in-Charge.
Disconnecting the electric supply from existing high mast panel, dismantling and taking down laltern carriage of high mast assembly and open up for examination of Engr-in-charge of high mast, dismantling and servicing complete lifting and lowering system and check the all mechanism assembly is housed in a chasis, pulley, flexible marine grade stainless steel wire rope, trailing cable, lubricating in bearings, cable connection, power tools, fidder pillar box and re-assembling the all mechanism and testing on completion complete all as specified and directed. Note :- (i) Renewal of items /spares such as bearing, foundation nuts, bolts, washers, fresh grease, pulley, chain, belt shall be deemed to be included in the above item. (ii) Cost of necessary tools and plants such as ladders, hydra for repair of high raised high mast light fittings etc shall be deemed to be included in the unit rate quoted.
Supply and fixing in renewal of flexible marine grade stainless steel wire rope without any intermediate joints and shall consists of only non corrodible as per existing size/grade (304 or 316) in flexible 7/19 breaking capacity of rope is 2350 kg x 2 complete all as specified and directed.
Supply and fixing in renewal of double drum winch mechanism system & including 140/90 SAE lubricant as per existing Make and capacity and safe working load 750 Kg complete all as specified and directed.
Supply and fixing in renewal of trailing cable flexible EPR insulated PCP sheathed round copper conductor power cable of size 5 core, 4 sqmm copper complete all as specified and directed.
Taking out from high mast winch/power tool and repairs, servicing and re-winding with super enameled copper conductor of existing size, testing on completion to electric motor 1/1.5 HP complete all as specified and directed.
M & L for rectification of LT cable, fault existing/as and when occurs with diagonising equipments as applicable and by joining with suitable LT cable joint kit complete all as directed. Note :- (i) Diagonising equipments, Skilled labour, Machinaries for excavation and re-filling earth work are to be provided/ arranged by the contractor at his expenses. (ii) If LT cable fault occurs in Road crossing then road cut surface to be made good after rectification work.
S & F in renewal for surge protector 10 kA with IP 65 protection, ISI marked, suitable for LED light fitting complete all as specified and directed.
S & F in renewal of electronic driver suitable for 45 Watts LED light fitting with IP 65 protection, ISI marked complete all as specified and directed.
S & F in renewal of electronic driver suitable for 60 Watts LED light fitting with IP 65 protection, ISI marked complete all as specified and directed.
S & F in renewal of electronic driver suitable for 90 Watts LED light fitting with IP 65 protection, ISI marked complete all as specified and directed.
S & F in renewal of electronic driver suitable for 120 Watts LED light fitting with IP 65 protection, ISI marked complete all as specified and directed.
S & F in renewal of electronic driver suitable for 150 Watts LED light fitting with IP 65 protection, ISI marked complete all as specified and directed.
Note for Srl Item Nos. 30 to 36 :- (i) Contractor will depute Electrician and helper as required for attending the complaints all as directed by Engineer-in-charge. The quoted rate of items shall be deemed to be inclusive of this aspect. (ii) Contractor/Supervisor will collect electrical complaints from concern JE on daily basis and will complete on same day and submit the performance silip duly signed by User's/complaintant. (iii) Contractor will provide suitable transportation for attending daily basis complaints on site like cycle/Motorcycle etc to each electrician/helper with proper driving licence/Halmet etc and keep permission of vehicle for inside premises by competent authority. (iv) Contractor will provide equipments like Hydra, excavation tools, discharge rod, Tester, Test lamp, Multi meter, cutting/side plier, screw driver, plier, electric hammer, drill machine, electrical wall cutting machine, wiring steel wire, industrial safety helmet, hand gloves, safety materials and related essential tools etc on his own arrangement for rectifying the complaint and also screws, nut, bolt, insulation tape, as per site requirement and no other payment will be made for the same.
S & F in renewal of energy effcient LED street light fitting of 45 Watt, epoxy poweder coated pressure die cast alumminium housing to act as heat sink for effcient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for beter throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fittinng should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting & including making electrical connection and including bracket of suitable size/ as per existing upto 1.5mtr long & MS flat clamp of suitable size/as per existing complete all as specified and directed.
S & F in renewal of energy effcient LED street light fitting of 60 Watt, epoxy poweder coated pressure die cast alumminium housing to act as heat sink for effcient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for beter throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fittinng should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting & including making electrical connection and including bracket of suitable size/ as per existing upto 1.5mtr long & MS flat clamp of suitable size/as per existing complete all as specified and directed.
S & F in renewal of 45 watt inverter LED street light with complete fittings with IR sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90 mins power backup in case of power failure, housing of fixture shall be pressure die cast and system efficency >100 LPW, CRI>70, CCT 5700K, PF>0.9, THD<15% complete all as specified and directed.
M/S SOLANKI GENERAL SUPPLIERS
KRISHNA CONSTRUCTION COMPANY
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .