| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹1.0 Cr | L1 | Accepted-AOC Over all rates are reasonable and lowest. |
| 2 | L2₹1.1 Cr+₹6.0 L (5.81%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹1.1 Cr+₹6.0 L (5.81%) | L2 | Rejected-Finance Over all rates are higher than L1. |
| 3 | L3₹1.1 Cr+₹11.1 L (10.8%)Rejected-Finance | ₹1.1 Cr+₹11.1 L (10.8%) | L3 | Rejected-Finance Over all rates are higher than L1. |
| 4 | L4₹1.1 Cr+₹12.0 L (11.7%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | ₹1.1 Cr+₹12.0 L (11.7%) | L4 | Rejected-Finance Over all rates are higher than L1. |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
2 Jun 2020, 6:00 pmClosed
CWE (AF) Izatnagar
CWE (AF) Izatnagar
PROVN OF HARD STANDING AT CERTAIN PLACES INCLUDING ADDITION /ALTERATION OF SERVICING BAYS AT AIR FORCE STN BAREILLY
2020_MES_328480_2
PROVN OF HARD STANDING AT CERTAIN PLACES INCLUDING
Open Tender
Civil Works
Item Rate
180 days
Izatnagar
As per NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) Izatnagar
₹2.1 L
Yes
15 Jun 2020
3 Apr 2020
4 Jun 2020
3 Apr 2020
2 Jun 2020
19 May 2020
Amount
Excavation over areas n exc. 1.50 m deep and getting out in Soft/loose soil complete all as specified and directed.
Surface excavation n exc 30 cm deep and average 15 cm and getting out in soft / loose soil complete all as specified and directed.
Add to (or deduct from) from item No. 2 above for every 3 cm or part thereof above or below 15 cm average depth in soft/loose soil complete all as specified and directed.
Demolition of unreinforced cement concrete in hard standing & paving, of any description and in any position, by mechanical tools complete all as specified and directed.
Removing demolished and excavated material /soils (obtained under BOQ item No. 1 to 4 & 33) exc. 1.50 km but n exc. 5 km and depositing where directed, complete all as specified and directed.
Rolling and consolidating formation surfaces in cutting with 8 to 10 ton power rollar, complete all as specified and directed.
Material and labour for 150 mm thick dry lean concrete (DLC) (compacted thickness) shall be M-15 of seven days compressive strength as 10 N/Sqmm (10 MPA) design mix (using OPC 43 grade cement and content of cement minimum 250 Kg/Cum) including necessary form work, rolling and compaction complete all as specified and directed. Note : In the event of increase in cement content as per design mix formula nothing extra shall be admissible and quoted rates are deemed to include the same.
M&L for sand filling 25mm thick including spreading levelling complete and all as specified and directed.
Supply and lay transparent polythene film sheet of thickness 400 micron as per IS-2508 all as specified and directed. Note:- Side lap of 150mm and end lap of 300mm shall be provided wherever required. The rate quoted shall be deemed included for the laps. Clear area only shall be considered for payment and nothing extra shall be allowed for laps.
M&L for 250mm thick Design mix Plain Cement Concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre (using OPC 43 grade cement and content of cement minimum 400 Kg/Cum), thickness of concrete 25 cm or less and complete all as speified and directed. Note : In the event of increase in cement content as per design mix formula nothing extra shall be admissible and quoted rates are deemed to include the same.
M&L for finishing surface of concrete roads, pavements, hard standings by brooming while the concrete is still green complete all as specified and directed.
M&L for forming 12 mm wide expansion joint , filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'B' for 250 mm thick concrete slab and complete all as specified and directed.
M&L for Forming Construction joint 10mm wide and 30mm deep by cutting with diamond cutter and filled with sealing compound Grade 'B' complete all as specified and directed.
ML for forming Contraction(Dummy) joint 65mmx10mm wide by cutting with diamond cutter and filled by sealing compound grade 'B' complete all as specified and directed.
S&F Steel rolling shutters (1mm thick laths) , with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with bevel gear box and crank handle complete and all as spcified and directed.
M&L Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement concrete 1:2:4 Type B-1 and Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc one brick not exc. two brick complete all specified and directed.
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and direcetd.
S&F Ball bearing for rolling shutters complete all as specified and directed.
M & L for preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
Preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of white birla wall care putty thickness not less than 1 mm complete all as specified and as directed.
Preparation of old plastered surface and rubbing down of existing treatment of and applying two coats of oil bound distemper complete all as specified and as directed.
Preparation of old ceillings surface and rubbing down of existing treatment of and applying two coats of whitewash over a coat of white wall care putty complete all as specified and as directed.
M&L Brick work with using fly ash brick, straight or curved on plan to any radius, in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L Brick work with using fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) and complete all as specified and directed.
M&L Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work for fair finishing complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel deformed or twisted bars 6 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3 type A-1 (nominal mix), using 20 mm graded crushed stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
S & F aluminium powder coated sliding windows with shutter and frame made with frame of aluminium section two track which consists of following: (a) frame 61.85 x 31.75 x 1.2mm not less than @ 0.659 Kg/RM weight (b) Shutters 40x18x1.5mm (c) Grill Aluminium powder coated grill weighing not less than weight 1.0 Kg/Sqm) (d) Glass 4.8mm thick tinted/reflective with rubber gasket and suitable clip (e) Stainless steel wire cloth Make : Jindal/ Hindalco/NALCO
Demlition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M & L for 100 mm thick cement concrete type B1 1;2;4 using (20mm graded aggregate) finishing the surface even and smooth without using extra cement casted in panels and complete all as specified and directed.
M & L for flame proof point wiring for one light point / fan point / 5 Amp socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including ERW mild steel stove enamelled rigid steel conduit having wall thickness not less than 1.60 mm and dia not less than 25 mm with and including flame proof fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing specifications and sunk cast iron or 1.2 mm thick pressed steel flame proof terminal box including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
(a) One light point controlled by one way switch.
(b) One Fan point controlled by one way switch.
All as per item No 36 here-in-before but with copper conductor 2.5 sqmm for One 3/5 pin socket outlet, 16/25 Amps on independent board all as specified and directed.
S&F LED light fitting 1 x 20 W Flameproof type FLP-WP, IP-65 protection made of aluminium alloy LM6 complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make :- Crompton Model No EXTN2LT8-16/20W or equivalent in Bajaj/Sudhir .
S&F Flame Proof Exhaust Fan 450mm sweep (18 inch), 1440 RPM, 230 Volts, single phase, 50 Hz, AC supply totally enclosed heavy duty motor of Cap 0.50 HP with die cast aluminium rotor mounted on two ball bearing complete with louvers including cutting chases for fixing fan, connecting electrically using 3 Core 0.5 Sqmm PVC insulated FRLS flexible copper conductor cable overall sheathed all as required at site with connected accessories etc confirming to Cat Pat No EF/140 of make Sudhir or equivalent make in Crompton / Bajaj complete all as specified and as directed. Note :- Flexible copper conductor cable shall be covered with flame proof flexible pipe.
S&F Flame Proof Wall Mounting Fan 415 mm sweep (16 inch), Single Phase, 1440 RPM for speed and oscillation motor, complete fixing arrangement on wall and connecting electrically using 3 Core 2.5 Sqmm PVC insulated FRLS flexible copper conductor cable overall sheathed all as required at site with connected accessories etc confirming to Cat Pat No WMF/140 of Sudhir or equivalent make in Crompton/Bajaj complete all as specified and as directed.
S & F of flame proof, weather proof directly entry type rotary switch with cable terminal box in cast aluminium alloy LM-6 enclosure epoxy powder coated single pole 230 volts 16 Amp ON / OFF switch AC certified by CRMI for group II-A & II-B including compression glands complete all as specified and directed. Make : Sudhir/Crompton/Bajaj
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amp, 250V, 2P+earth complete all as specified and directed. Make : Sudhir/Crompton/Bajaj
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amp, 250V, 2P+earth complete all as specified and directed. Make : Sudhir/Crompton/Bajaj
Supply, laying & testing of LT Cable XLPE insulated, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 50 Sqmm 3.5 Core complete all as specified and as directed.
S&F MCCB 63 Amps capacity, 415 volts, 4 pole, 16 KA, thermal magnetic complete all as specified and directed.
M & L for horizontal boring under Road, pavement, hard standing complete with inserting GI pipe light grade of size 50/80mm dia all as specified and directed. Note :- GI pipe shall be measured and paid seperately
Supply and laying/fixing GI tubing light grade with all fittings and fixed complete to walls, ceilings and laid in floors, for cable protection of size 80mm dia all as specified and directed.
S & F of following factory made V TPN DBs-DPX-160 MCCB DB's 4 way, IP-43 protection-IK09 with metal door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and SP/TP MCB's as DPX 160 +12 outgoing etc complete all as specified and directed. Make :- Legrand/Schnieder/L&T
Supply and fix MCB SP (single pole) 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series all as specified and directed.
Supply and fix blanking plate complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts of galvanized iron or steel including 15mm dia GI pipe light grade upto 1.5 mtr below GL for protection pipe, excavation and earth work charcoal dust, common salt, PCC 1:3:6 type C-1 chamber with cover and RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both way with MS handle 12mm dia PGI funnel and wire mesh all as shown in electrical plate No 5 of SSR Part-I connected to ear thing test point all as specified or indicated including testing on completion all as directed by Engr-in-Charge.
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out all as required for laying of cables, all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (Soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for dry sand cushioning for protection of under ground cables (8cm before laying the cable and 15cm after laying the cable in trenches) complete, all as specified and directed. Note : Punned thickness of sand shall only be measured and paid.
M&L for well burnt Sub class 'B', modular bricks laid dry, flat, over the cable abutting each other, length of brick equal to width of brick, complete all as specified and directed.
M/s Arihant Builders
TEAM ACC INFRABUILD PRIVATE LIMITED
Shikhar ji Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .