Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.7 L
EMD Value
₹6,755
Closing Date
8 May 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE LSGD
AE LSGD
Annual Plan Project NO 195 Perumannur mullankattil road last portion RenovAnnual Plan Nadapuram GP Motor and electrification of Parakunnath Drinking water projectation ward 3 General Civil Work
2023_LSGD_573231_4
01/23-24/AE/LSGD/NDPM
Open Tender
Electrical Works
Item Rate
180 days
NADAPURAM GP
Please refer Tender documents.
9 documents required · 9 mandatory
₹600
₹6,755
Yes
9 May 2023
28 Apr 2023
9 May 2023
28 Apr 2023
8 May 2023
28 Apr 2023
Amount
Motor and electrification of Parakunnath drinking water
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD417961/2022-2023:Supply and fixing 50mm ASTM socket 80 Sch
OD417962/2022-2023:Supply and fixing 65mm (2 1/2") GI Flange in the existing suction/delivery pipe using required leak proofing materials etc. as required.
OD417963/2022-2023:Supply and fixing 50mm (2") GI flange in the existing suction/delivery pipe line using required leak proofing materials etc. as required
OD417964/2022-2023:Supply, laying and fitting 50 mm 80 Sch ASTM pipe with suitable type solvent etc. as required at site,
OD417965/2022-2023:Supply and fixing 50mm 80 Sch ASTM Tee
OD417966/2022-2023:Supply and fixing 50mm 80 Sch ASTM Union Code
OD417967/2022-2023:Supply and fixing 50mm 80 Sch ASTM Threaded Adaptor Male
OD417968/2022-2023:Supply, installation, testing and commissioning of 2 1/2" Cast Iron Non Return Valve in the existing PVC/ ASTM pipe
OD417973/2022-2023:Supply and providing32 A 2 way neutral link on existing meter board using suitable nut.bolt etc as required.
OD417974/2022-2023:Supply and providing the following types and power rated lamps in the existing fittings as required 9 w, LED bulb
OD417975/2022-2023:Supply and fixing 50mm B class GI pipe as support for hanging submersible motor pump set in open well
OD417976/2022-2023:Supply and fixing 50mm 80sch ASTM bend
OD417977/2022-2023:Supply and fixing 50 mm ( 2'') GI flange in the existing suction/delivery pipe line using required leak proofing materials etc as required
OD417978/2022-2023:Supply and fixing 75x63 mm PVC reducer
OD417979/2022-2023:Supply and fixing 50 mm GM Ball valve in the existing ASTM pipe Zoloto make or equivalent
OD417980/2022-2023:Supply and providing 6 mm stranded steel rope for hanging submersible motor pump set
OD417981/2022-2023:Supply and providing 20-63A offset staggered HRC fuse link
OD417984/2022-2023:Supply and installation of dust and vermin proof, 3 phase Syntax meter Board (GS-MB-6535) and to fix KSEB meters, fuse units,CT etc as required including fixing it on wall , making good the damageds colour washing et as required.
OD417985/2022-2023:Supply and providing 25x6 mm brass nut bolt etc. as required
OD417986/2022-2023:Supply and providing 2x25x3 mm GI strip as test joint on the existing watering pipe of earthing includeing bending and giving connections
OD417987/2022-2023:Providing and fixing 25 mm x 3 mm GI Strip on surface or in recess for connections etc as required.
OD417988/2022-2023:Supply and providing Danger 415 V, 150x100mm Enameled danger plates
OD417989/2022-2023:Painting letters or figures with enamel paint as identification mark to SB,DB panel board etc as required
OD417990/2022-2023:Supply and providing LEDindicator lamp(Blue colour) in the existing panel board and giving connection
OD417991/2022-2023:Supply and providing LED indicator lamp (Red, Green, Black, Yellow, Orange colours)in the existing panelboard and giving connectionRed ,Green, Black, Yellow, Orange
90.14.24.43:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.4 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.
OD418179/2022-2023:40 A bakelite fuse holder with fuse link and necessary bolt and nut
OD418241/2022-2023:Supply installation testing and commissioning of 3 phase , 10 HP , open well vertical submersible pump set with maximum head of 213 metre, discharge 13500 litre per hour at 127 mtr head, 11 stage pump using chain block suitable tools and plants. (Head range 53 to 213 metre) (Deccan make 10DLM/11 model or equivalent make).
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
Bidder Name
gopakumar.kv
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .