Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹24.0 LAccepted-AOC 58 NEW MARKET CLOCK TOWER DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | I | Accepted-AOC First Lowest | |
| 2 | II₹28.8 LAccepted-AOC | II | Accepted-AOC Second Lowest |
Tender Value
Refer Docs
Closing Date
4 Jan 2022, 5:00 pmClosed
Executive Engineer
Executive Engineer, Mechanical Division, Uttarakhand Peyjal Nigam, Haldwani -263139
Dumkabangar Umapati Tubewell Water Supply Scheme of Distt Nainital Supply Installation Testing Commissioning and One month operation and maintenance of pumping plants and all other E and M Appurtenant works
2021_MDPEY_40350_1
2717/E-Tender/80 Dated 16.12.2021
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
90 days
Haldwani block
Pleasa refer tender documents
3 documents required · 3 mandatory
₹2,360
Executive Engineer, Mechanical Division. UPJN, Hal
Exempted
Haldwani
25 Jun 2025
18 Dec 2021
6 Jan 2022
18 Dec 2021
4 Jan 2022
28 Dec 2021
27 Dec 2021
Amount
S.I.T.C. of Submersible Pumping Plant with Accessories for Proposed Tubewell
Supply of Submersible pump and motor set: 1000 L.P.M. discharge at 100 mts. NEH.
Supply of Submersible pump and motor set: 1000 L.P.M. discharge at 100 mts. NEH. as spare.
Supply of Fully automatic start delta Starter cum panel of Suitable of above pump Set as per spacification and site Requirment.
Supply of Main piping and valves as per specification and site Requirment
Supply of of 25 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable
Supply of 100KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirment
Supply of chain pulley 5 tonne capacity with 4.5mt.lift .
Supply of Electronic type liquid chlorine dosing system
Supply of Chlorine Testing Kit
Supply of Liquid Chlorine (50 Kg Cane)
Supply of Gauges as per specification
Supply of Earthing materials as per specification and site Requirment
Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr.
Supply of 160 Amp. TPN Main Switch
Tools and Spanners –
Installation, commissioning and Testing of all pumping plant & Accessoriees complete
Internal & External Electrification of pump house for Proposed Tubewell
Wiring for light point/fan point, exhaust fan point, call bell point with15.sq.mm FRLS PVC insulated copper conductor single core cable in surface, recessed medium class PVC conduit , with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc, as reuired.
Wiring for circutit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2x2.5 sq. mm +1x2.5sq.mm earth wire
2x4 sq. mm +1x4sq.mm earth wire
supplying and fixing following piano type switch/scoket on the existing switch box/cover including connections etc. as required.
5/6amps switch
3pin 5/6 amp socket outlet
supplying and fixing metal box of 150mm x75mm x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front incuding providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
supplying and fixing metal box of 180mm x100mm x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front incuding providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
S/F 3 pin , 5 amp celling rose on the exting junction box/wooden block including connection etc, as required.
S/F brss batten, angle holder including connction etc, as requird.
supplying and fixing 6 way Double door, single pole and neutral, sheet steel, MCB distribuiton board, 240v, on surface/recess, complete with tinned copper bus bar , neutral bus bar, earth bas, din bar, interconnections, power painted indulding earthing etc. as required (But without MCB/RCCB/Isolator)
S/F 5 amps to 32amps rating, 240/415 volts, "C" curve, mainature circuit braker suitable for inductive load of follwing poles in the existing MCBDB compete with connection, testing and commissioning etc. as required.
Single Pole
Double Pole
S/F Security light LED Type, 40 watts with bracket, clamp, connection etc compete in all respect
S/F 23 watts CFL
S/F of LED T_5, 18 watts tubelight fitting connection etc, compleat in all respect
S/F of exhaust fan (i.s.i mark) with jali, 450mm sweep, including making hole for exhaust fan and connection etc, complete in all respect.
Automation of Centrifugal Pumping plant
GSM based Intelligent Remote Terminal Units (IRTU) with Analog and Digital parameters and features as specified to store and transmit data on GSM backbone to LMS. And also compatible to communication for pumps (2x1).
GSM Based wireless communication system capable to transfer data from remote sites control station with antenna (2x1).
Intelligent Energy Meter(2x1).
Valve actuator size 150mm(2x2).
Actuator panel (2x2).
Isolation transformer (2x1).
Cables
2 Core 1.5sq.mm. (2x100).
4 Core 2.5 sq.mm. (2x40).
10 Core 1.5 sq.mm. (2x30).
PVC conduit Pipe.
AC& DC, Relay lugs etc.
Electromagnetic Insertion type Flow Meters for line sizes 80mm (2x1).
Erection, commissioning and Testing & customization of iRTU/PLC & software
One month Trial Running operation, Maintenance including watch & ward.
shyam engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .