| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹30.8 L+₹38,545.85 (1.27%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹31.6 L+₹1.3 L (4.15%)Rejected-Finance 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹39.3 L+₹8.9 L (29.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
14 Feb 2022, 6:00 pmClosed
CWE (NW) Kochi
CWE (NW) Kochi PIN-682004
REPAIRS TO SEWAGE LINE INCLUDING CLEANING OF SEPTIC TANK AND SEWAGE LINE, MANHOLE AND REPAIR TO DRAIN, HARD STANDING, PLINTH PROTECTION, PATH ETC AT DERA COMPLEX (PANAMPILLY NAGAR), DAD COMPLEX (THEVARA) VARSHA, VARUNA, FERSON, DAWSON VIHAR TARANGINI
2022_MES_502106_1
CWE(NW)KOCHI/81252
Open Tender
Civil Works
Item Rate
240 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹500
GE (NW) Kochi
₹91,000
Yes
10 Mar 2022
17 Jan 2022
16 Feb 2022
17 Jan 2022
14 Feb 2022
31 Jan 2022
17 Jan 2022 - 7 Feb 2022
Amount
M&L for opening/Lifting of Man hole cover and taking out waste soil,sludge, other sediments, solid waste, and liquid waste from septic tank/soak well/Manhole in any condition by SEWAGE SUCTION TRUCK or any other mechanical means,and refix the man hole cover on completion of work, complete all as specified and as directed. Notes for Item No 1 to 10 :- (a) No complaints will remains pending more than 06 hrs (Except major complaints) else necessary recovery will be made against contractor as per CA clause, Daily collection of complaint slip from complaint cell and returning back to complaint cell is the responcible of the contractor. (b) The night soil, other sediments, solid waste, and liquid waste in any condition removed from septic tank shall be taken away from respective vicinities Premises on closed containers / conveyance and disposed off out of defence land (c) Disposal of the same shall be the responsibility of the contractor with out any extra expenditure to government. Disposal of waste shall be made in accordance with the regulations of authorities concerned. d) The unit rate quoted shall be deemed to be inclusive of cleaning the neared MH & sewage line from that MH to septic tank
Labour only for clearing of blocked manhole of any size and any depth complete all as specified and directed.
Labour only for cleaning of blocked sewage line/soil pipes of any size and any depth complete all as specified and directed.
Cleaning of culverts and covered drains of any depth/width after removal of RCC cover slab and refixing the same in position after cleaning and removal of silt to outside the defence land. Note: clearing to be done pre monsoon and post monsoon items as per requirement and measure separatly complete all as specified and as directed.
Labour only for cleaning/clearing in multistory buildings for blockges of WHB, Kitchen sink, WC, etc pipes of dia 75 to 110 mm size including cleaning in bend T & Y junction in shafts/walls if required by opening the oval access door of the fittings and refixing the same without any leakage or seepage complete all as specified and directed. Note: The quoted rate shall be inclusive of necessary scaffolding in multistory buildings.
Labour only for cleaning/clearing of blocked GULLY TRAP / Floor TRAP / nahni trap, WC ‘P’ trap or ‘S’ trap and refixing the same after cleaning after cleaning the pipes making good damaged with non skid tiles / CM 1:3 and WPC etc., as required in site complete all as specified and directed.
M&L for destruction of growth of weed plants with roots on the roof of bldgs and on the wall of bldgs at any height with 2.40 'D' oil mixed veedicides or mixed with veedol chemical solution and sprayed in and around roots and at places of possible growth of weeds complete all as specified and as directed. Note:-(i) In case of plants that has trees like growth, the plant should be cut to avoid damages to roof/wall and rest to be treated with chemical solution (ii) The area after treatment shall be cleaned off all debris branches dead plant, (iii) Rate incl Height upto 12 storey building ,incl necessary scafolding seafty arragements etc.
Demolition of brick work built or stone /boulder masonry, built in cement mortar, including all quoins, pillars etc but ashalar facing , dressed stone work , precast concrete articles complete as specified and as directed .
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete as specified and as directed .
Demolition by breakingup drain pipes (salt glazed stone ware/AC/ RCC) 150 mm dia jointed in cement mortar and takinout of trenches and removing debris incl concrete bed haunching from the site to a distance n.exc . 100 mtr complete all as specified and as directed.
Demolition of PCC in ground floors and avings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of PCC any description and in any position not otherwise specifically provided complete all as specified and as directed.
Excavation in trenches not exc 1.5M wide and not exc 1.5M depth for foundation , etc for shafts , wells , cess pits , man holes , etc 10 sqm on plan and gettingout in loose soil.and getting out in soft/loose soil.complete as specified and as directed .
M&L for cement 1:3:6 type C2 with using 40 mm graded stone aggregate as in concrete bed to drain pipes 150 mm bore including packing under,and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed.
S & F 150 mm bore PVC (SWR) Pipes a single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed.
M & L for PCC Cement concrete in surface channels and drains type C2 (1:3:6) using 40 mm graded stone aggregate complete all as specified and as directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed.
All as per Item No 17 above but add or deduct for each 25 mm girth or part thereof over or under 30 cm complete all as specified and as directed.
M & L for 100 mm PCC path/hardstanding type C2 (1:3:6) using 40 mm graded stone aggregate finishing the surface even and smooth with out using extra cenment and spike rolling to surface or making impression of expand metal while the concrete is green complete all as specified and as directed.
M & L for PCC plinth protection 75 mm thick type C2 (1:3:6) using 40 mm graded stone aggregate finishing the concrete surface even and smooth with out using extra cement complete all as specified and as directed.
M & L for PCC in foundation filling and mass concrette type C2 (1:3:6) using 40 mm graded stone aggregate complete all as specified and as directed.
M& L for Brickwork built in cement mortar (1:4) with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work on concrete surface in CM 1:4 finished even and smooth without using extra cement complete complete all as specified and as directed.
S&F in repairs 100 mm dia cast iron branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with cement joints upto 4th storey complete all as specified and as directed.
All as per item No.24 above but 5th to 8th storey complete all as specified and as directed.
All as per item No.24 above but 8th to 12th storey complete all as specified and as directed.
S&F n repairs 75 mm dia cast iron branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches upto 4th storey building complete all as specified and as directed.
All as per item No.27 above but 5th to 8th storey complete all as specified and as directed.
All as per item No.27 above but 8th to 12th storey complete all as specified and as directed.
S & F in repairs Cast Iron Soil, 100 mm waste and vent pipes, in any length with or without ears, with cement joints ,fixed on wall
All as per item no .30 but 75 mm dia complete all as specified and as directed.
S & F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm Bore
All as per item no .32 but 75 mm dia complete all as specified and as directed.
M & L in repairs PVC (SWR) floor trap 75 mm dia plain with grating including jointining with solvent cement.
S & F in repairs PVC (SWR) junction single (single T ) equal or unequal provided with access door for 75 mm dia pipe including jointining with solvent cement.
All as per item No.35 above but 110 mm dia complete all as specified and as directed.
S & F in repairs PVC (SWR) bend any radius 75 mm dia including jointining with solvent cement. .
All as per item No.37 above but 110 mm dia complete all as specified and as directed.
S & F in repairs bends cast iron any radius 100 mm bore diminshing pieces or tapers (large bore measured).ncluding jointining with solvent cement.
All as per item no .39 but 75 mm dia complete all as specified and as directed.
S & F in repairs Cover of CI oval acess door with bolts and rubber gasket to make it water tight for 100 mm bore CI bends complete all as specified and directed by Engr-In-Charge .
All as per item no .41 but 75 mm dia complete all as specified and as directed.
S & F in repairs Cast Iron Soil, 100 mm waste and vent pipes, in any length with or without ears, with cement joints , laid in trenches or in floor complete all as specified and as directed.
All as per item no .43 but 75 mm dia complete all as specified and as directed.
S & F in repairs 110 mm dia PVC (SWR) branch piece single (single Y ) (equal or unequal) ordinary or inverted (spigot or socket type ) or with parallel branch up to 4 th storey complete all as specified and as directed.
All as per item No 45 above but 5th to 8th storey complete all as specified and as directed.
All as per item No 45 above but 9th to 12 th storey building complete all as specified and as directed.
S & F in repairs 75 mm dia PVC (SWR) branch piece , single (single Y) (equal or unequal ) ordinary or inverted (Spigot or socket type ) or with parallel branches up to 4th Storey complete all as specified and as directed.
All as per item No 48 above but 5th to 8th storey complete all as specified and as directed.
All as per item No 48 above but 9th to 12 th storey building complete all as specified and as directed.
M & L for Cutting into the manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete (1:2:4) type B1 smooth finished , and reforming benching as required of 150 mm bore complete all as specified and as directed.
M & L PCC (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate as in benching, coping etc including necessary form work complete all as specified and as directed.
M & L for pre-cast reinforced cement concrete cover for man hole with concrete (1:2:4) type B1 with using 20 mm graded stone aggregate set in CM (1:6) , including form work required complete all as specified and as directed. Note :- Reinforcement shall be measured and paid separately.
S&F 6 mm dia to 8 mm dai TMT deformed bars as in reinforcement cut to length, bent to shape required including cranking, bending and binding with mild steel (annealed) wire not less than 0.9mm dia complete all as specified and as directed.
Returning, filling including spreading levelling watering and well ramming in layers not exc 25 cm thick(soft/loose soil) complete all as specified and as directed.
Removal of excavated soil to a distance exc 50M and n.exc 100M and deposited at a level not exc 1.5M above the starting point complete all as specified and as directed.
Dismantiling Stone slabs and tiles of any description or thickness in floors, aprons etc laid dry complete all as specified and as directed.
S & F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 With Grey Cement pigment match to existing surface incl leveling and preparation old surface incl 50 mm sand cusion bed below paver block etc and pointing to match existing surface complete all as specified and as directed.
Re -fixing of stone slab and tiles obtained from demolition complete all as specified and as directed.
M& L Coarse aggregates of nominal size 6.3 mm and below as in paving under floor spreading and levelling in layers n exc. 25 cm thick well ramming including watering as required complete all as specified and as directed.
M & L for PCC sub base 75 mm thick type D2 (1:4:8) using 40 mm graded stone aggregate finishing the concrete surface even and smooth with out using extra cenment complete all as specified and as directed.
S & F Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors With grey cement no pigmentsincl screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes and pointing with cement mortar with existing surface etc complete all as specified and as directed.
MS BUILDERS
Anaswara Constructions
Chittoor Engineering Industries
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .