| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC VILLAGE BHANGEDI MAHAVATPUR POST MILAP NAGAR ROORKEE HARIDWAR 247 666 | HARIDWAR | UTTARAKHAND | 247666 | L1 | Accepted-AOC 1st lowest and reasonable | |
| 2 | L2₹6.5 L+₹830 (0.13%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.6 L+₹11,450 (1.76%)Rejected-Finance 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹6.8 L+₹30,075 (4.63%)Rejected-Finance C 23 CC | L4 | Rejected-Finance L4 | |
| 5 | L5₹7.0 L+₹49,670 (7.65%)Rejected-Finance 133 SADAK DUDHLI SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹19,500
Closing Date
20 Aug 2021, 6:00 pmClosed
AGE(I) Raiwala
AGE(I) Raiwala Raiwala Cantt Dehradun (U.K)
REPAIR / REPLACEMENT AND CLEANING OF WATER STORAGE TANK GI /CI/PVC PIPE TO MD / OTM ACCN IN ZONE A AND B AND OTHER LOC AT MIL STN RAIWALA
2021_MES_464258_1
8858/E8
Open Tender
Civil Works
Item Rate
180 days
Raiwala
As per tender documents
8 documents required · 8 mandatory
₹5
AGE(I) Raiwala
₹19,500
Yes
9 Sept 2021
31 Jul 2021
23 Aug 2021
31 Jul 2021
20 Aug 2021
6 Aug 2021
Amount
Cleaning of storage water storage tank of RCC/PVC of exc 250 but n. exc 500 Ltrs capacity staged over RCC roof/floor slab or similar place inside /outside buildings by removing float valves inlet and outlet carefully, thoroughly cleaning the entire surface (internal & external), mouth of pipes etc scrubing with bleaching powder, to make the tank totally dirt free and finally cleaning the water tank with fresh water till water becomes clear to the entire satisfaction of Engineer-in-charge and as specified in particular specifications and refixing of float valves all as specified and directed by Engineer-in –Charge
All as per above item here in before but water tank of capacity exc 500 but n. exc 1000ltrs
All as per above item here in before but water tank of capacity exc 1000 but n. exc 2000ltrs
Dismantaling of old water tanks and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, ISI marked, double layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
Dismantaling of old water tanks and S&F new rotational moulded polyethylene water storage tank 500 liters capacity, ISI marked, double layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
S & F in repair for PVC water tank covers, circular type with suitable nut and bolts complete for water tanks of 500 to2000 litres capacity all as specified and as directed.
S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule and fixed.
Writing letters “TANK CLEANED ON DD MM YYYY” of not exceeding 7.5cm high each letter, painted with black letters on sufficient white back ground on external visible face of water tank with synthetic enamel paint complete all as specified and as directed. Note:- Complete set of letters on each tank will be measured as one unit/ Job.
Taking up or down steel water tubing of 15 mm bore and connections including cleaning for refixing or removing to store. .
Taking up or down steel water tubing of 20 mm bore and connections including cleaning for refixing or removing to store. .
M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work , medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs.
S & F in repairs 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F in repair Stop Valve 15mm bore of standard PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms/20mm- 125gms).
S&F bib taps 15mm bore of standard PTMT any colour ahigh pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms/20mm- 125gms).
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F pillar taps 15mm bore of standard PTMT any colour ahigh pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms/20mm- 125gms).
S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe.
S&F in repair for PVC Connections 15mm size with PTMT nuts of length 600 mm
S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union
S&F in repairs 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kg f per Cm Cm Square fixed to walls, ceilings or in floors etc.
Taking down eves, gutters and soil waste pipes (any size or pattern) incl all fittings,heads, shoes,bends and swan neck etc incl cleaning for refixing or removal
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 75 mm bore PVC (SWR) bends of any radius
S & F 75 mm bore PVC (SWR) bends of any radius with access door
S & F 110 mm bore PVC (SWR) bends of any radius
S & F 110 mm bore PVC (SWR) bends of any radius with access door
S & F PVC (SWR) reducers of size 110 mm x75 mm
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 75 mm bore PVC (SWR) Vent Cowl
S&F in repair stack clamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stamp including bolts and nuts and securing ends of stays to walls or roof for 110 mm pipe, complete all as specified and directed.
Ditto as per above item but 75 mm bore pipe.
M & L for for shifting aside of MS monkey case of any size & weight for repair / replacement of water tank, GI pipe, tank staging & refixing the same as required at site and as directed by Engr-in-Charge
DIKSHA CONSTRUCTION CO
AJAY KUMAR CONTRACTOR
RAMAN CONSTRUCTION CO.
ANKIT KUMAR
TARUN ENGINEERING WORKS
M/s RP AGRAWAL
SWASTIKA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .