| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | ₹32.1 L Quoted ₹34.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹38.8 LRejected-AOC | ₹38.8 L | L2 | Rejected-AOC L2 |
| 3 | L3₹40.3 LRejected-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | ₹40.3 L | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Contractor has no Valid GSTR |
| 5 | Rejected-Technical 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | - | - | Rejected-Technical Does not meets the criteria |
| Sl No | Description | Qty | Unit | General Engineering and Constructions L1 | K.V.GEORGE AND COMPANY L3 | 3 VOLT ELECTRICALS ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil for laying pipes etc including forming bottom surface to required level complete all as specified and directed | 380 | Cum | 200 ₹76,000 | 300 ₹1.1 L | 295 ₹1.1 L |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soft/loose soil complete all as specified and directed | 342 | Cum | 100 ₹34,200 | 80 ₹27,360 | 195 ₹66,690 |
| 3.00 | Removing excavated material (soil) to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed | 38 | Cum | 100 ₹3,800 | 90 ₹3,420 | 85 ₹3,230 |
| 4.00 | Taking up DI water mains 300 mm bore (including all fittings) with spigot and socket ends and, lead joints including burning out joint complete all as specified and directed | 60 | RM | 100 ₹6,000 | 200 ₹12,000 | 299 ₹17,940 |
| 5.00 | All as per item No 4 here-in-before, but 250mm bore pipes complete all as specified and directed | 60 | RM | 100 ₹6,000 | 150 ₹9,000 | 198 ₹11,880 |
| 6.00 | All as per item No 4 here-in-before, but 200mm bore pipes complete all as specified and directed | 180 | RM | 100 ₹18,000 | 90 ₹16,200 | 144 ₹25,920 |
| 7.00 | All as per item No 4 here-in-before, but 150mm bore pipes complete all as specified and directed | 220 | RM | 100 ₹22,000 | 80 ₹17,600 | 99 ₹21,780 |
| 8.00 | All as per item No 4 here-in-before ,but 100mm bore pipes complete all as specified and directed | 200 | RM | 100 ₹20,000 | 70 ₹14,000 | 74 ₹14,800 |
| 9.00 | Re-laying in trenches DI pipes of size 300mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No. 4 here-in-before complete all as following size complete all as specified and directed .
(Note:- Tighten ring joint /run lead joints and DI specials/fittings shall be measured and paid separately) | 30 | RM | 300 ₹9,000 | 175 ₹5,250 | 890 ₹26,700 |
| 10.00 | Re-laying in trenches DI pipes of size 250mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No.5 here-in-before complete all as following size complete all as specified and as directed .
(Note:- Tighten ring joint /run lead joints and DI specials/fittings shall be measured and paid separately) | 30 | RM | 250 ₹7,500 | 125 ₹3,750 | 799 ₹23,970 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹90,220
Closing Date
1 Nov 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR AND MAINTENANCE OF WATER SUPPLY PUMPING LINES , SLUICE VALVES AND CONNECTED WORKS AT KATARIBHAGH AND NAVAL BASE KOCHI
2025_MES_723717_2
8513/E8
Open Tender
Civil Works - Water Works
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹90,220
Yes
12 Feb 2026
10 Oct 2025
4 Nov 2025
10 Oct 2025
1 Nov 2025
18 Oct 2025
Amount
Excavation in trenches not exc. 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil for laying pipes etc including forming bottom surface to required level complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soft/loose soil complete all as specified and directed
Removing excavated material (soil) to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed
Taking up DI water mains 300 mm bore (including all fittings) with spigot and socket ends and, lead joints including burning out joint complete all as specified and directed
All as per item No 4 here-in-before, but 250mm bore pipes complete all as specified and directed
All as per item No 4 here-in-before, but 200mm bore pipes complete all as specified and directed
All as per item No 4 here-in-before, but 150mm bore pipes complete all as specified and directed
All as per item No 4 here-in-before ,but 100mm bore pipes complete all as specified and directed
Re-laying in trenches DI pipes of size 300mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No. 4 here-in-before complete all as following size complete all as specified and directed . (Note:- Tighten ring joint /run lead joints and DI specials/fittings shall be measured and paid separately)
Re-laying in trenches DI pipes of size 250mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No.5 here-in-before complete all as following size complete all as specified and as directed . (Note:- Tighten ring joint /run lead joints and DI specials/fittings shall be measured and paid separately)
Re-laying in trenches DI pipes of size 200mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No. 6 here-in-before complete all as following size complete all as specified and as directed . (Note:- Tighten ring joint /run lead joints and DI specials/fittings shall be measured and paid separately)
Re-laying in trenches DI pipes of size 150mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No.7 here-in-before complete all as following size complete all as specified and as directed . (Note:- Tighten ring joint /run lead joints and DI specials/fittings shall be measured and paid separately)
Re-laying in trenches DI pipes of size 100mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos/steel rod effectively (pipe taken out/obtained from item No. 8 here-in-before complete all as following size complete all as specified and as directed . (Note:- Tighten ring joint /run lead joints and DI specials/fittings shall be measured and paid separately)
Supplying laying and testing in trenches centrifugally cast (spun) ductile iron pipes of 300 mm dia suitable for pressurized water delivery with spigot & socket end, class 'K-9' conforming to IS:8329/2000 (latest version) - blast furnace slag cement with Portland cement properties suitable for (push on) rubber gasket jointing with inside cement mortar lining and black bitumen external coating, duly ISI marked in any length complete all as specified and directed.
All as per item No 14 here-in-before but of size 250mm bore pipes complete all as specified and directed
All as per item No 14 here-in-before but of size 200mm bore pipes complete all as specified and directed
All as per item No 14 here-in-before but of size 150mm bore pipes complete all as specified and directed
All as per item No 14 here-in-before but of size 100mm bore pipes complete all as specified and directed
Material and labour for ISI marked ductile iron socketed fittings supplied as per IS: 9523/2000 of class K-12, PN-1.0 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 100mm dia to 300 mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch, cross collars, caps and plug set including rubber ring push on joints complete as specified and directed.
All as per item No 19 here-in-before but for flanged fittings complete all as specified and directed
Cutting the existing CI/ DI pipes in position for insertion of new collars/ Tees /branches/new pipes 300 mm dia CI Pipe complete all as specified and directed at site.
All as per item No 21 here-in-before but of size 250mm bore pipes complete all as specified and directed
All as per item No 21 here-in-before but of size 200mm bore pipes complete all as specified and directed
All as per item No 21 here in here-in-before but of size 150mm bore pipes complete all as specified and directed
All as per item No 21 here-in-before but of size 100mm bore pipes complete all as specified and directed
Material and labour for joint with tighten ring joint of 300mm bore DI spigot and socketed pipes pipes/fittings complete all as specified and directed.
All as per item No 26 here-in-before but of size 250mm bore complete all as specified and directed
All as per item No 26 here-in-before but of size 200mm bore complete all as specified and directed
All as per item No 26 here-in-before but of size 150mm bore complete all as specified and directed
All as per item No 26 here-in-before but of size 100mm bore complete all as specified and directed
Supply and fix in replacement of 300 mm bore cast iron sluice valve with flanged ends of type PN-1.6 conforming to IS-14846:2000 with cast iron wheel and brass spindle including taking down old unserviceable one complete all as specified and directed
All as per item No 31 here-in-before but of size 200 mm dia complete all as specified and directed
All as per item No 31 here-in-before but of size 150 mm dia complete all as specified and directed
All as per item No 31 here-in-before but of size 100 mm dia complete all as specified and directed
Supply and fix cast iron Air release valve with two air outlets 100 mm bore and fixing up in cast iron water supply mains including taking down old unserviceable one complete all as specified and as directed
Supply and laying in trenches 80 mm outer dia of CPVC pipes with CPVC Sch 40 pipes & plain Sch 80 fittings and jointed with CPVC primer & solvent cement including taking down old unserviceable GI tubing,, complete all as specified and as directed.
Supply and laying in trenches 50 mm outer dia CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings, including jointed with yellow solvents cement including taking down old unserviceable GI tubing complete all as specified and as directed.
Supply and laying in trenches 40 mm outer dia CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings, including jointed with yellow solvents cement including taking down old unserviceable GI tubing complete all as specified and as directed.
Supply and laying in trenches 25 mm outer dia CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings, including jointed with yellow solvents cement including taking down old unserviceable GI tubing complete all as specified and as directed.
Supply and fix, 50 mm outer dia of high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings and jointed with yellow solvents cement including taking down old unserviceable GI tubing fixed to walls /ceiling or laying in floors complete all as specified and as directed.
All as per item No 40 here-in-before, but 40 mm dia of pipes complete all as specified and directed
All as per item No 40 here-in-before but 25 mm dia pipes complete all as specified and as directed
Supply and fix in replacement CI Butterfly valve 300 mm bore with necessary fittings complete all as specified and as directed
Supply and fix in replacement CI Butterfly valve 100 mm bore with necessary fittings complete all as specified and as directed
Supply and fix in replacement CI Butterfly valve 80 mm bore with necessary fittings complete all as specified and as directed
Supply and fixing ,50 mm bore CPVC Ball valves Suitable for CPVC pipe with necessary fittings, including taking down old one complete all as specified and as directed.
Supply and fixing ,40 mm bore CPVC Ball valves Suitable for CPVC pipe with necessary fittings, including taking down old one complete all as specified and as directed.
Supply and fixing ,25 mm bore CPVC Ball valves Suitable for CPVC pipe with necessary fittings, including taking down old one complete all as specified and as directed.
Supply and fix in replacement of 100 mm cast iron equilibrium float valve double beat type rubber seated float valve with copper float with lever arm , Right angle pattern, compressed asbestos flanges, Class 125 FF (Drilled) including core cutting and fixing arrangement to the existing inlet pipe along with necessary support including taking down old unserviceable one complete all as specified and directed
All as per item No 49 here-in-before but of size 80 mm dia complete all as specified and directed
Supply and fix in repairs 40 mm bore float valve synthetic (PVC) high pressure with polythene ball of suitable size and flynut including taking out old one complete all as specified and directed.
All as per item No 51 here-in-before but of size 25 mm dia complete all as specified and directed
Supply and fix, in replacement of 50mm bore Gun metal Gate/Globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC pipe , complete all as specified and as directed .
All as per item No 53 here-in-before but 40mm dia complete all as specified and directed
All as per item No 53 here-in-before but 25mm dia complete all as specified and directed
Testing of water as per table 1 Organoleptic and physical parameters of IS - 10500-2012 in a Govt approved laboratory all as specified and directed. Note :- Quality of water shall be tested (routine test) and test certificate to prove the potability of water issued by a Govt approved laboratory shall be produced by the contractor. The water shall be tested for essential characteristics, Bacteriological examination for routine test as laid down in IS : 10500-2012 and conform to the requirements. Note :- (i) Sample of water shall be taken jointly once in a month by the representative of Engineer-in-Charge and contractor from any of the pump houses of Naval Base and Kataribagh Area on the guide lines given by Engr-in-Charge
Attending any type of leakage/shortage/overflow in water supply Pumping lines laid at various locations inside Kataribagh and Naval Base area for detection of nature of defect including carry out minor repairs to make the pumping line functional complete all as specified and directed Notes :- (a) The unit rate quoted shall be deemed to be included the elements of labour only for arresting the leakage and making the pumping line functional for minor repair releasing air locks, checking closed valves any, etc. If replacements of pipe/items is required to make the supply line functional, the cost of labour and material for the same shall be measured and paid as "Supply & fix/Material & labour in repairs" under relevant items of this schedule. (b) If leakage/shortage of water shall not be attended & rectified in the same day as received by the contractor except major break down, the recovery will be made @ Rs 500/- per breakdown per day and after 15 days of non functional of any pumping line, as specified for any reason, the recovery will be made @ 2000/- per day till the distribution line functional
Cutting the existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the disturbed surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Material and labour for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment any size for making cover for valve pits including nuts,bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape of size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of synthetic enamel paint (Black colour) including taking out old corroded plates complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 1.2 x1.2 x 0.9 Mtrs (internal dimensions) including excavation and earth work in any type of soil, PCC 1:2:4 type B-2 in foundation brick work in CM 1:4, 15mm thick plastering in CM 1:4 internally and flush pointing externally in same mortar as the work process angle iron frame work 40X40X6mm, with 6mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer including demolition of old valve pits complete all as specified and directed.
Supply and replace unserviceable water pressure gauge MS of dial size 2.5 inch any type of capacity 0 to 300 psi Including necessary GI pipe connection of existing size complete as per existing all as specified and as directed .
Material and labour for repairing of existing brick masonry of valve chamber of size (0.9mx0.9mx0.9m) to (1.2mx1.2mx0.9m) 50% (approx) including opening of valve cover,dewatering and cleaning the chamber thoroughly, cleaning and removing rust from valve body and moving parts using wire brushes/ emery paper.chamber repair work to inner walls/floor including removal of debris and plastering with CM 1:4, 15 mm thick. painting of visible surfaces of chamber with two coats of cement-based waterproof paint.sheet cover and frame shall be painted with two coats of synthetic enamel paint as per prescribed colour over a coat of red oxide primer including necessary surface preparation. Replacement of damaged locking arrangements,hinges,handle,(12mm dia) and fixing new lock with two keys if required. All tools,equipment,consumables,paints,labour and materials required shall be included.Work to be completed as per site condition and as directed.
3 VOLT ELECTRICALS ENTERPRISES (BID ID -3458264)
K.V.GEORGE AND COMPANY (BID ID -3465086)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
COMMONPAGES8513.pdf
Tender Documents • 0.58 MB
PS8513.pdf
Tender Documents • 0.42 MB
BOQ_822543.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid