Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC 30 74 BLOCK NO EXTRA 30 TRILOK PURI DELHI EAST DELHI 110091 | DELHI | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC Selected | |
| 2 | L2₹45.9 L+₹3.4 L (7.96%)Rejected-AOC | L2 | Rejected-AOC Selected | |
| 3 | L3₹47.4 L+₹4.9 L (11.5%)Rejected-AOC E76 LGF KALKAJI BHAIRAV MANDIR NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L3 | Rejected-AOC Selected |
Tender Value
₹51.3 L
EMD Value
₹1.0 L
Closing Date
9 Aug 2019, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Renovation of Conference hall including refreshment area at 13th floor, Vyapar Bhawan, New Delhi.
2019_PWD_177376_1
138 /EE (E)/PWD DHC and ND/Central /2019-20
Open Tender
Electrical Works
Works
60 days
New Delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹1.0 L
20 Oct 2020
30 Jul 2019
9 Aug 2019
30 Jul 2019
9 Aug 2019
30 Jul 2019
Amount
SH - 1 : EI Works Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C.
wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pins 5/6 & 15/16 ampers modular socket outlet and 15/16 ampers modular switch, connection etc as required.
Supplying and fixing of following size/modules, GI box alongwith modular base and cover plate for modular switches in recess etc as required. a) 8 Module (125mm X 125mm)
b) 12 Module (200mmX150mm)
Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. a) 15/16 ampers switch
b) 6 pin 15/16 ampers socket outlet
Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 36W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system Lumen of 34W to 36W LED should be ≥ 3600 system efficacy of ≥ 100 lumen/watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>80, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
Supplying & fixing of energy efficient 15 watts LED down lighter luminaries in the surface including connection, testing etc. as required The Total minimum system efficacy of luminaries should be minimum 80 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying and fixing of following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4 + 24), Double door
Supplying and fixing of 5 ampers to 32 ampers rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Providing and fixing of following rating and breaking capacity and pole MCCB in existing TPN DB including making connections, etc. as required. a) 125 Ampers, 16 KA breaking capacity TP MCCB (Icu=100% Ics)
Supplying, Installation, testing & commissioning of metal body wall fan of 400 mm sweep size including making connection, etc. complete as required.
Supplying and laying of following size XPLE armoured aluminum Power cable of 1.1KV grade on existing surface etc as required. a) 3.5x35 sq.mm
SH - 2 : FIRE FIGHTING Works Supplying, installation, testing & commissioning of Optical type Smoke Detector SR 65 with LED Indicator and with base and circuit complete etc as required.
Providing and fixing of flexible joint for sprinkler of 1.0 Meter Length having male inlet of 25 mm. diameter at one end and female out let of 15 mm diameter at other end (U.L. listed, F.M. approved) together with G.I. sootter 25 mm diameter, G.I. Nipple 25 mm diameter and Rosetter of stainless steel duly polished for 15 mm diameter sprinkler head etc as required
Providing & Fixing of Brass Sprinkler heads pendent / upright type 15mm diameter to operate at 680º C etc as required
Providing & laying / fixing, testing and commissioning of "C" class heavy duty MS pipe conforming to IS 1239 / 3589 in existing surface including accessories like elbows, tees, flanges, tapers, nut bolts, gaskets angle iron frame work etc. with the help of dash fastner including anticorrosive treatment complete as required including dismantling of existing M.S. pipe etc as required a) 150 mm diameter
b) 100 mm diameter
c) 65 mm diameter
d) 25 mm diameter
SH:-3 : AUDIO VIDEO WORKS Supplying, installation, testing & commissioning of compact 2-way LCR loudspeaker System for Main foh sound & Delay Speakers with minimum 10” LF, HF - 1" exit (2” VC), Max SPL(peak) : 122db / 1m, RMS Power :250-300 watt (EIA), Nominal Impedence : 8 ohms, Nominal Dispersion : 90 x 60, 7 Integrated flying points, Wedge cut for Monitor use etc as required.
Supplying, installation, testing & commissioning of high quality Subwoofer with 1x 17" or above (3" VC), Max SPL : 132db / 1m, RMS Power : 700 - 800 W (AES) RMS, Nominal Impedence 4 ohms etc as required.
Supplying, installation, testing & commissioning of Dual Channel Power Class H amplifier for Subwoofer & Main Speakers , 2x1500W @ 2 ohms, 2x1100 W @ 4 ohms, 2x750W @ 8 ohms, Damping factor > 450, etc as required.
Supplying, installation, testing & commissioning of Dual Channel Class H Power amplifier for Delay Speakers 2 x 350 W @ 8 ohms, 2 x 500W @ 4 ohms, 2 x 1000W @ 2 ohms, with Damping factor > 350, etc as required.
Supplying, installation, testing & commissioning of Professional 20-channel Compact Mixer with onboard effects and USB I/O, 16 low-noise, high-headroom Mackie mic preamps with easy LED metering, 32-bit RMFX™ processor with 16 “Gig-Ready” reverbs, choruses and delays, Precision 7-etc as required.
Supplying, installation, testing & commissioning of 3x6 Loudspeaker Management System w/ Display, Impedance 120 ohms, sample rate 48kHz, THD 0.002%, etc as required.
Supplying, Installation, testing & Commissioning of Gooseneck cardioid Microphone for podium & dial stage table , polar pattern Cardioid, Frequency Range 70-18000 Hz, Sensitivity18mV/Pa, Impedance >2000 ohms etc as required.
Supplying, Installation, testing & Commissioning of main SYSTEM RACK ( 24u ) - M.S. Rack with Power indicator, power sockets and isolator fitted duly prewired to accommodate Control Room equipments e.g. Amplifiers, Controller, Equalizer etc as required.
Supplying, Installation, testing & Commissioning of Wall mountable Speaker Brackets with X and Y axis rotation, Cast Iron with Powder Coated paint finish etc as required.
Supplying, Installation, testing & Commissioning of PATCH CORDS ( for SYSTEM INTERCONNECT ) - High grade professional low-noise bable, 2-Core High conductivity PVC insulated in PVC jacket,shielded Copper Cable with di-electric insulator to prevent RF interference with necessary XLR male/female connectors EP Jacks / RCA Jacks etc as required.
Supplying, laying & Fixing of Microphone Lines High grade, profeional, Low-noise, 2-Core High conductivity PVC insulated in PVC Jacket, Shielded, Copper Cable with di-electric insulator both end with XLR m/f connector etc as required.
Supplying, laying & Fixing of Speaker Lines: 2-Core, 2.5 sq mm High definition Speaker Cable, PVC insulated in PVC jacket laid in existing conduits etc as required.
Supplying, installation, testing & commissioning of Micorphone Connector Stage Junction Box – made out of M.S. sheet connector box, openable lid finished in stove enamelled paint accomodating connectors etc as required.
Supplying, installation, testing & commissioning of DLP Lazer technology projector For Center Main Projection with wuxga resolution 1920 x 1200 with 6000 Ansi lumens brightness minimum or above with contrast ratio of 15000:1 ; with standard lens etc as required.
Supplying, installation, testing & commissioning of HDMI cable of 20 meter length for projector etc as required.
Supplying, installation, testing & commissioning of av with 2inputs & 4 outputs switcher for laptop connectivity & av mixing etc as required.
Supplying, installation, testing & commissioning of Led Professional Display panel with 60 inch size for Side walls Display with Full HD Resolution of 1920 x 1080 ; with all necessary accessories etc as required
Supplying, installation, testing & commissioning of 10 fts x 8 fts Motorized screen for Center Projection with remote control etc as required
SH:-4 :VRF AIR CONDITIONING Works Supplying, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, low noise condenser fan, auto check function for connection error as per specifications. 1. The COP of the outdoor units at 100% load should not be less than 3.7 (at 35 Deg C ambient conditions). 2. Each outdoor unit shall have multiple compressors etc as required. a) 24 HP
Indoor Units Supplying, installation, testing & Commissioning of Ceiling suspended cassette type indoor units with evaporator coil, fan and fan motor drain pan and inbuilt drain pump, air filter etc as required. a) 4 Way cassette/ 3 TR
b) 4 Way cassette/ 2 TR
Supplying, Installation, Testing & Commissioning of Y-joints ( Suction + Liquid = complete set) for Indoor Unit of sizes as required to suit various capacity of Indoor Unit as specified above etc as required.
Supplying, Installation, testing and commissioning of Interconnecting refrigerant pipe work with (19mm/13mm thickness) closed cell elastomeric nitrile rubber tubular insulation, between each set of indoor & outdoor units and as per specifications, all piping inside the building & shaft shall be properly supported with MS hanger etc as required. a) 34.9 mm diameter (1.10 mm thickness)
b) 31.8 mm diameter (1.10 mm thickness)
c) 28.6 mm O.D.(1.0 mm thickness
d) 22.2 mm O.D.(1.0 mm thickness)
e) 19.1 mm O.D.(1.0 mm thickness)
f) 15.9 mm O.D.(1.0 mm thickness)
g) 12.7 mm O.D.(0.8 mm thickness)
h) 9.5 mm O.D.(0.8 mm thickness)
Supplying & Installation of heavy duty PVC drain pipe with insulation. Insulation shall be of 6 mm thickness sleeve of nitrile rubber etc as required at site. a) 25 mm
Supplying and fixing of following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A
Supplying and installation of following size of perforated Hot Dipped Galvanized Iron cable tray (galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. a) 300 mm width X 50 mm depth X 1.6 mm thickness
b) 450 mm width X 50 mm depth X 2.0 mm thickness
SH:-5 : UNINTERRUPTED POWER SUPPLY Work Supplying, installation, testing and commissioning of uninterrupted power supply system of 10 KVA capacity 3 phase input to 1 phase output in configuration for 220Volts + 15%, Single phase, 50Hz, AC supply input and output 220 Volts, single phase, 50 Hz, 4 wire, AC supply output with Pulse width Modulated Insulated gate Bipolar Transistor (PWM IGBT based rectifier & inverter) technology capable for continuously delivering the 100% rated power, with proper Microprocessor based LCD display indication panel for various parameters display & LED indication for alarm for major status parameters, inbuilt static by pass switch with minimum 30 minutes power backup time on connected load for each UPS, with suitable capacity, battery bank of minimum VAH 12 050 SMF battery with MS battery racks, isolation transformer inbuilt @ I.P. side suitable battery circuit breaker, battery interconnection cable with computer communication etc. as required. (Certification : 62040-1, 62040-2, 62040-3, CE, BIS)
Classic Refrigeration Works
SKYLINE AIR CONDITIONING ENGINEERS PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .