Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.9 LAccepted-AOC | 1 | Accepted-AOC Lowest Rate | |
| 2 | Rejected-Technical | - | Rejected-Technical Opened. No documents recieved and hence the bid is rejected. | |
| 3 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹20.7 L
EMD Value
₹50,000
Closing Date
22 Apr 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
JAYAPRAKASH R
MANAGER REHABILITATION PLANTATIONS LTD KOOVAKKADU P O KULATHUPUZHA
RETENDER 2J ELECTRIFICATION
2025_RPL_737112_2
RPL/KE/A1/2836/2024
Open Tender
Electrical Works
Item Rate
90 days
KULATHUPUZHA
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
Yes
₹50,000
Yes
11 Jul 2025
28 Mar 2025
24 Apr 2025
29 Mar 2025
22 Apr 2025
29 Mar 2025
29 Mar 2025 - 7 Apr 2025
Amount
2.3.1 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
od89699/2024_2025 Supplying and fixing Sheet steel DP MCB enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.
od89702/2024_2025 Supplying and fixing FP sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
od99488/2024_2025 Supply of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes . 4 core 16 sq mm with factory made clamp
90.16.2.5 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class)
7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing masonry open duct as required. Upto 35 sq. mm
7.1.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required. Upto 35 sq. mm
7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
od101913/2024_2025 Supplying and fixing SMC junction box for cable termination (250MM x 200MM x 105MM) along with MCB channel , terminal connectors and all interconnections etc
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
90.6.10.2 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm
90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.5 sqmm
14.1 Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X4 sq. mm + 1 X 4 sq. mm earth wire
1.7.8 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 4 sq.mm + 2 X 4 sq. mm earth wire
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm
1.17.2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 4 x 1.5 sq. mm
1.17.20 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 2 x 4 sq. mm
1.17.22 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 4 x 4 sq. mm
od85596/2024_2025 Supply and installation of 10mm PVC stay wire for fixing service wire
od85597/2024_2025 Supplying and fixing of Anchor hook for service wire stay rope.
od109699/2024_2025 Supply and fixing Push Button Station with 1 set ( 3 Nos ) R,Y,B LED indication lamp AC, 22.5 mm cut out dia. inIncluding connections , terminations etc completed
1.23.1 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
od111741/2024_2025 Supplying and fixing 20 A, HRC Fuse Base with 2A HRC Fuse link.(4 Nos)
od111993/2024_2025 Supply, installation and commission of following Power Capacitors 3 phase delta connected in positon and giving connection 2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Box Type Capacitor suitable for direct connection to motors.
od116082/2024_2025 Supply, installation and commission of following Power Capacitors 3 phase delta connected in positon and giving connection 4 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Box Type Capacitor suitable for direct connection to motors.
od112131/2024_2025 Supply, installation and commissioning of single phase 1KVAR Capacitor Box type for Power Factor improvement
od84597/2024_2025 Earthing with G.I. earth pipe 1.5 metre long, 40 mm dia including accessories, and providing masonry enclosure without cover plate with charcoal/ coke and salt as required and filling the enclosure with 20mm stone aggregate
90.6.10.1 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 20 mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
od64357/2024_2025 Supplying and fixing Single Phase Energy Meter Box (metal type) on surface/ recess, complete with 32A Cut out fuse -1 No, SPN 32A MCB-1 No etc, interconnections, powder painted including earthing etc. as required.(But without Energy Meter)
od64358/2024_2025 Supplying and fixing Single Phase Energy Meter Box (metal type) on surface/ recess, complete with 32A Cut out fuse -1 No, DP 40A MCB-1 No etc, interconnections, powder painted including earthing etc. as required. (But without Energy Meter)
od89843/2024_2025 Supplying and fixing Single Phase Energy Meter Box (SMC type-Sintex) on surface/ recess, complete with 32A Cut out fuse -1 No, SPN 32A MCB-1 No etc, interconnections including earthing etc. as required. (But without Energy Meter)
od84343/2024_2025 Supplying and fixing Three Phase Energy Meter Box (metal type) on surface/ recess, complete with 32A Cut out fuse -3 Nos, TPN MCB 40A -1 No etc, interconnections, powder painted including earthing etc. as required. (But without Energy Meter)
od84404/2024_2025 Supplying and fixing Three Phase Energy Meter Box (SMC type-Sintex) on MS Iron Brackets fixed on 40mm medium class GI Pipe, complete with 63A Cut out fuses -3 Nos, TPN MCB 63A -1 No, 4P RCCB 63A, 30mA etc, interconnections, painted including earthing etc. as required. (But without Energy Meter)
od109673/2024_2025 Supplying and installation of SMC type( Sintex) Box suitable for Motor Starter enclosure, Power Capacitor and DB enclosure complete with Single Phase Motor Starter DOL type, upto 3HP etc. interconnections, painted including earthing etc. as required.(Without DB, Capacitor and accessories)
od109681/2024_2025 Supplying and fixing of Metal Structure for fitting single phase Energy Meter Box (SMC type-Sintex) and MC type Sintex Box suitable for Motor Starter enclosre and DB enclosure 40mm medium class GI Pipe, complete
od85600/2024_2025 Dismantling of old Main Switch board with accessories and its connection complete and shift the same to stacking space as per the direction of the in charge of the work
od85603/2024_2025 Dismantling of old energy meter board with accessories and its connection complete and shift the same to stacking space as per the direction of the in charge of the work
12.40 Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
12.41 Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. asrequired.
12.42 Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc.as required.
od109199/2024_2025 Documentation for energisation from KSEBL of following single phase connections including preparation of all documents required 1. Labour Quarters -72 Nos Typical wiring 2. Type -1&2 Staff Quarters-25 Nos 3. Type -3 Staff Quarters -5 Nos 4. Type -4 Staff Quarters -1 No 5. Others - 5 Nos
od85554/2024_2025 Documentation for energisation from KSEBL of following three phase connections including preparation of all documents required 1. Staff Quarters -1 Nos 2. Pump House -2 Nos
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .