Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.0 LAccepted-AOC D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹58.8 L+₹9.7 L (19.9%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹67.6 L+₹18.5 L (37.8%)Rejected-Finance 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | Rejected-Technical III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | - | Rejected-Technical Being Adverse Remark in WLR of HQ, CECC for QE Sep 2021 |
Tender Value
₹98 L
EMD Value
₹1.7 L
Closing Date
9 Mar 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs for Replacement of BER Lifts at Niveditha, Eklavya and HQ ENC Canteen Side Buildings Under GE Utility-I, Visakhapatnam
2022_MES_504785_1
82207 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
1365 days
Visakhapatnam
Class C
Category c ii
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Utility - I
₹1.7 L
Yes
31 Mar 2022
2 Feb 2022
16 Mar 2022
2 Feb 2022
9 Mar 2022
23 Feb 2022
2 Feb 2022 - 9 Feb 2022
Amount
PHASE - I SCHEDULE 'A' PART-I
[c] Battery operated emergency light [LED Ceiling Fitting] alarm [speaker for emergency alarm system to be fixed] and stop button in car with rechargeable arrangement for battery. [d] Designer Six sleek circular LED light fitting 5 Watts x 4 Nos. in false ceiling [e] Provision of one cross flow fan suitable for recessed mounting in false ceiling [f] Provision of premium quality Jet black Granite stone slab of 18-20 mm thick as in flooring for lift car (Not more than two parts) over 3 mm thick aluminium chequered sheet. [g] Nonstop button/ independent operation. [h] Over load warning indicator with both audio and visual type with overload protection/ tripping system having relays , etc. [j] Front landing door of stainless steel Mirror finish, operations with a minimum time of 10 sec and up to a maximum time of 30 seconds. [k] Stainless steel sliding doors with front opening for all Landings made of 16 gauge stainless steel sheet with Mirror finish with vision panel of size 200 X 800mm covered with 8mm thick toughened plain glass. [l] All the dimensions of the lift ad connected items shall be designed in conformity with IS 14665 standards and the contractor shall subit the design drawing to Accepting Officer for approval before commencementof work. The body shall be stainless steel of 16 gauge with Mirror finish with 38mm dia stainless steel hand rail with hairline finish. [m] Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. [n] Stainless steel hand rail 38mm dia with hairline finish. [o] Specification plate with complete details [p Full length display indicator panel.
[q] Provision of suitable phase reversal relays to the controller to protect lift/ equipment against phase reversal, phase failure and low voltage. [r] Intercom be conected with nearest security post. [s] Continuous earthing for machine and equipment [t] Steel Wire rope of adequate size as per relevant IS and as per manufacturers specification. [u] Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, car operational panel, governor, locks, power control and trailing cables complete all as per latest IS specifications. [v] Main drives and controls shall be high efficient and low power consumption. [w] Lift design, specifications, drawings, manufacturers instructions shall be got approval from Accepting Officer before placing order for procurement. [x] The contractor shall carry third party load testing for each lift installed once in every six months and shall submit staisfactory test results and the rate quoted shall be deemed to included for this provision.
All as described in serial item No. 1 herein before but 10 Passenger lift [680 kg capacity] 7 Floors i.e. G + 6 upper floors, speed 1.5 metre/ sec at NSB/ NIVEDITHA
All as described in serial item No. 1 herein before but 8 Passenger lift [544 kg capacity] 6 Floors i.e. G + 5 upper floors, speed 1 metre/ sec at Eklavya HQ
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. including taking down of existing earthing set complete all as specified.
S & F Aluminium Strip of size 25 X 4.0 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
Dismantling Existing earthing and providing new Maintenance Free Chemical Earthing complete with Copper plate 900mm X 600mm x 5 mm and 32 x 6mm Copper strip with 50 KG of Backfill Compound buried directly in ground [Rocky Soil] with earth pit not less than 2.25 m deep below ground level with top edge of Plate not less than 1.50 m below normal ground level connected to existing Copper Earth Strip by means of Stainless Steel bolts, nuts, check nuts and washers all as per IS – 3043 including testing on completion complete all as specified and as directed. The earth resistance shall be measured using fall of potential method as per Para 37 of IS – 3043 & combined resistance should be less than 1 Ohms. Note: The unit rate quoted shall be deemed to include for PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS handle 12mm dia, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S & F MCCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCCBs and including one MCCB, FP, 63 Amps, 16 KA, 415 Volts, 50 Hz complete all as specified and as directed.
Supplying, laying, testing and commissioning of XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
S & F On-Load Changeover Switch, FP, 100 Amps, 415 Volts, 50 Hz, AC, Front Operated Handle, in sheet steel enclosure, with Advance Neutral and conforming to IS – 13947 [Part – 3] & IEC:60947–3 including taking down old Change Over Switch of any description complete all as specified and as directed.
PHASE – II [Schedule "A" Part – II]: Comprehensive Maintenance of Passenger Lifts as Provided Under Schedule "A"/ BoQ Part – I for Three Years After Successful Completion of Defects Liability Period of Work under Phase – I]:
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 13 Passengers [884 KGs] Capacity, serving G+5 Floors, installed at HQ ENC Canteen side, catered under Serial Item No. 01 of BoQ / Schedule "A" Part – I for Third Year after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 10 Passengers [680 KGs] Capacity, serving G+6 Floors, installed at NSB/ Niveditha, catered under Serial Item No. 02 of BoQ / Schedule "A" Part – I for Third Year after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 8 Passengers [544 KGs] Capacity, serving G+5 Floors, installed at Eklavya HQ, catered under Serial Item No. 03 of BoQ / Schedule "A" Part – I for Third Year after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 13 Passengers [8847 KGs] Capacity, serving G+5 Floors, installed at HQ ENC Canteen side, catered under Serial Item No. 01 of BoQ / Schedule "A" Part – I for Fourth Year after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 10 Passengers [680 KGs] Capacity, serving G+6 Floors, installed at NSB/ Niveditha, catered under Serial Item No. 02 of BoQ / Schedule "A" Part – I for Fourth Year after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 8 Passengers [544 KGs] Capacity, serving G+5 Floors, installed at Eklavya HQ, catered under Serial Item No. 03 of BoQ / Schedule "A" Part – I for Fourth Year after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 13 Passengers [884 KGs] Capacity, serving G+5 Floors, installed at HQ ENC Canteen side, catered under Serial Item No. 01 of BoQ / Schedule "A" Part – I for Fifth Year after after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 10 Passengers [680 KGs] Capacity, serving G+6 Floors, installed at NSB/ Niveditha, catered under Serial Item No. 02 of BoQ / Schedule "A" Part – I for Fifth Year after successful completion of work under Phase-I complete and all as specified and as directed.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 8 Passengers [544 KGs] Capacity, serving G+5 Floors, installed at Eklavya HQ, catered under Serial Item No. 03 of BoQ / Schedule "A" Part – I for Fifth Year after successful completion of work under Phase-I complete and all as specified and as directed.
Escon Elevators Pvt Ltd
Omega Elevators
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .