Loading…
Loading…
Tender Value
₹4.8 Cr
EMD Value
₹9.7 L
Closing Date
22 May 2026, 3:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SNT TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where, V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Any RI or EI or CLS or ABS or IBS work involving indoor & outdoor work (Cable laying & termination)
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Checklist for Tenderer: The Tenderer shall submit signed copy of Check-list placed in documents attached with tender. The Tenderer shall also submit relevant documents of compliance of the checklist if any.
I/We have read the tender notice (NIT)detail, schedule of material and works and Tender document along with all the conditions attached/referred to, in this tender document and agree to abide by the said conditions.
It is certified that i am the authorized person to represent the firm and I am authorized to sign the tender and all the document on behalf of the firm.
I/We hereby agree to abide by the Indian Railway Standard General Condition of contract (GCC) with all correction slip up to date and to carry out the work according to the special conditions of contract and specification of material and works as laid down by Railway as mentioned in the tender document.
Bhavnagar Division: Supply, Installation, Programming, Testing and Commissioning of Electronic Interlocking (E.I) system along with outdoor S&T work and provision of MSDAC in connection with Vadal- Developing new loading lines in new Goods Shed at Vadal statin of Bhavnagar Division.
DRMSnT-BVP-Sig05Rof26-27
DRMSnT-BVP-Sig05Rof26-27
Open
Works - General
12 Months
Bhavnagar, Gujarat
₹0
₹9.7 L
22 May 2026
30 Apr 2026
8 May 2026
305 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,35,28,042.54 | ||
| — | 220.00 | — | — | ||
| Design, manufacture and supply of Hot Standby Architecture Electronic Interlocking (EI) system i.e. Distributed or Centralized as per requirement of zonal railway, complete as per RDSO specification and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment, Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks, fuses, screw less disconnecting type terminals, fixture mounting arrangements, Industrial grade maintenance Terminals (32'' LED or higher size with UPS minimum 1 hr back up with Printer) and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2. 3. Non vital I/O- can be used only for accessories where SIL-4 condition required. 4. Station less than 200 routes- RDSO/SPN/192/2019 Ver.2.0 with latest amendment. Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC-DC Convertors, Moxa switch, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note: Rate does not include cost of VDUs and Embedded PC. Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. (Unit Read as Per Functional Vital Bit). | — | — | — | 1,83,12,401.8 | |
| — | 2.00 | — | — | ||
| Supply of Smart Cabinet/Rack for Housing of Various S&T equipments like KLCR, Reset Box, IPS Indication Panel, CA VA Unit for FACS, SP AU for Point Reversal, Crank Handle, Quad Cable Earth Sensing Unit along with Fixing of KLCR (KLCR will be provided by Railway) as per instruction of Site Engineer, Make RITTAL, SANTEL, VERO, PRESIDENT, APC Schneider or similar reputed make. | — | — | — | 1,16,061.54 | |
| — | 500.00 | — | — | ||
| Rubber Mat for Power Equipment room. (5mm thick). | — | — | — | 60,815 | |
| — | 2.00 | — | — | ||
| Monitoring Unit for Multi Section Digital Axle counter (MSDAC) as per RDSO Specification No. RDSO Specn. No. RDSO/SPN/176/2013ver.3 or latest. Prior approval to be taken from railway for make. | — | — | — | 2,15,232 | |
| — | 8.00 | — | — | ||
| Supply of Axle counter cable conductor's Earth resistance Sensing unit. Microcontroller based for 12 nos conductors with metering facility for one conductor at a time. Installation as per instruction of Engineer in charge. | — | — | — | 2,67,082.88 | |
| — | 4.00 | — | — | ||
| DC-DC Converter for HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3 or latest. Note: DC-DC converter will be compatible with existing system. Prior approval to be taken before supply. | — | — | — | 1,03,840 | |
| — | 2.00 | — | — | ||
| New Reset Box RB 259A for HASSDAC as per RDSO Specn. No. RDSO/SPN/177/2012 ver. 3 or latest. Note: Prior approval to be taken from Railway for make of MSDAC. | — | — | — | 1,13,280 | |
| — | 1.00 | — | — | ||
| Remote monitoring unit with following specification. Core i-5 10 th Generation Processor, 8 GB (DDR4) RAM, 1TB HDD, 256GB SSD, 15.6 inches FHD Display, Wireless LAN, Port available: USB, HDMI, RJ45 Ethernet, Windows 10 professional and MS Office both licensed, Licensed Quick Heal/Kaspersky/Norton Antivirus for 03 years, 03 years OEM onsite warranty and carrying bag. It should be of reputed make - HP or Lenovo or Dell only. Prior approval of Engineer in charge to be taken before supply. | — | — | — | 68,700 | |
| — | 4.00 | — | — | ||
| Supply of Surge protection device (SPD) 4- Pole, 5 V versions similar to model no MDP- 4 D-5-T of OBO make. Make OBO, Phoenix, ABB or DEHN. | — | — | — | 19,399.2 | |
| — | 1.00 | — | — | ||
| Data logger system for Railway S&T installation as per spec. IRS: S-99 2006 (Amdt-3) or latest. Central Monitoring Unit with UPS minimum 06 hrs battery backup and required Software tools. This also includes the supply of one no composite computer & printer table (Godrej workstation table) for keeping the Processor module and one no Godrej make operator chair model PCH7001. 1024 digital and 32 Analog inputs. | — | — | — | 6,30,312.5 | |
| — | 1.00 | — | — | ||
| Failure Analysis System or Central Monitoring Unit with Printer. As per technical specification IRS: S-992006 (Amdt-3) or latest. The specification of Failure Analysis System should be got approved from the Engineer in charge before supply. The Specification of Failure Analysis System shall be as per technical specification given in Contract Agreement or higher version as approved by Engineer In-Charge. | — | — | — | 2,87,336.91 | |
| — | 1.00 | — | — | ||
| Failure Analysis & Fault Diagnostic software for data logger of 1024 digital inputs /4096 digital inputs. As per RDSO Guide line. | — | — | — | 52,451.4 | |
| — | 1.00 | — | — | ||
| Supply of LED based Indication & Announcement system / Unit having six indications, Buzzer, Acknowledgment Button and with digitized announcement of the fault message with interface facility to existing Data Logger and Modification of data logger embedded software when a station master fails to set the point against the occupied line within stipulated time after arrival of the train and transfer of the Safety Point Alarm Unit Health status to the existing CMU at central location through the data logger network. | — | — | — | 47,484.74 | |
| — | 4.00 | — | — | ||
| Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028. [Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. | — | — | — | 1,04,997.68 | |
| — | 3.00 | — | — | ||
| Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | — | — | — | 72,024.36 | |
| — | 5.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4B Contact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 27,880.2 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq. mm. (85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 33,366.21 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm). 101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 1,36,063.55 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 1,32,505.12 | |
| — | 10.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 55,485.4 | |
| — | 300.00 | — | — | ||
| Supply of 35 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 74,322 | |
| — | 300.00 | — | — | ||
| Supply of 10 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 31,701 | |
| — | 3.00 | — | — | ||
| Extinguisher CO2 type (capacity 4.5 kg. or above) As per instruction of Engg in charge. | — | — | — | 25,574.88 | |
| — | 8.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 2,37,949.04 | |
| — | 2.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in Signalling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 1,03,907.56 | |
| — | 300.00 | — | — | ||
| Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 19,290 | |
| — | 2000.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 46,760 | |
| — | 100.00 | — | — | ||
| Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. | — | — | — | 5,721 | |
| — | 5.00 | — | — | ||
| Miniature, Plug in Type, M to C, DC Neutral, Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec: BRS :939-A & 966 (Appx-F2) & IRS: S-23, S-23, S-34 & 60. | — | — | — | 24,394.5 | |
| — | 5.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral, Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec: BRS:933A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 27,107 | |
| — | 5.00 | — | — | ||
| Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 17,616.35 | |
| — | 5.00 | — | — | ||
| Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic moulded base). | — | — | — | 4,892.3 | |
| — | 15.00 | — | — | ||
| Track Lead Junction Boxes as per C. Rly Drg. No. RST 11509 made from fibre glass/SMC/FRP along with terminal blocks. | — | — | — | 16,809.75 | |
| — | 5.00 | — | — | ||
| GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. | — | — | — | 340.85 | |
| — | 15.00 | — | — | ||
| Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split- Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement). | — | — | — | 20,188.95 | |
| — | 10.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer in charge as per requirement. | — | — | — | 97,439.7 | |
| — | 15.00 | — | — | ||
| Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377 Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys. | — | — | — | 2,34,166.05 | |
| — | 5.00 | — | — | ||
| Apparatus Case half NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A fitted two nos E Type lock of (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys. | — | — | — | 49,469.95 | |
| — | 15.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet 1000x1000x8. | — | — | — | 80,830.05 | |
| — | 500.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | — | — | — | 29,265 | |
| — | 30.00 | — | — | ||
| Supply of 4 connection points single potential through screw less terminal block for 6 Sq.mm - 35 Sq.mm, 4 connection points 284-621/624 or superior, suitable for power cable connection. | — | — | — | 8,125.2 | |
| — | 30.00 | — | — | ||
| Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | — | — | 332.1 | |
| — | 20.00 | — | — | ||
| Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | — | — | 217.2 | |
| — | 10.00 | — | — | ||
| Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 1,138.8 | |
| — | 4000.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec Nos/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 3,00,000 | |
| — | 30.00 | — | — | ||
| Pad locks Godrej makes, Hardened Navtal 7 lever, 65mm Dia with common key or similar product having same feature & technical data. | — | — | — | 5,903.7 | |
| — | 500.00 | — | — | ||
| Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type. | — | — | — | 2,17,760 | |
| — | 30.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die, & 103.5 mm inner dia. One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | — | — | — | 57,366 | |
| — | 72.00 | — | — | ||
| Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 84,260.16 | |
| — | 8.00 | — | — | ||
| Colour Light Signal Complete. This includes: - (1). Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA- 24625 (Advance). (2). CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3). Pinnacle. (4). Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. (5). Signal Front Staging Complete Assembly for CLS Unit. (6). Signal back staging as per extent WR Practice. Note: Height of the Post shall be 5.5 Long. | — | — | — | 1,11,950.32 | |
| — | 5.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway Signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 1,42,888.6 | |
| — | 4.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway Signalling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 1,19,295.64 | |
| — | 2.00 | — | — | ||
| Junction route indicator unit 2 way as per Drg. No. RDSO SA 23402 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest. | — | — | — | 41,981.52 | |
| — | 4.00 | — | — | ||
| Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. | — | — | — | 22,458.48 | |
| — | 25.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs / bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197with latest Amd. | — | — | — | 2,60,077 | |
| — | 40.00 | — | — | ||
| Earth Electrode as per Drg. No. CSTE / 6091. | — | — | — | 1,11,959.6 | |
| — | 30.00 | — | — | ||
| Supply of copper strip for earthing (25mm x 3mm). | — | — | — | 17,194.8 | |
| — | 100.00 | — | — | ||
| Supply of GI flat for earth (50 X 6 mm). | — | — | — | 20,667 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS11.pdf
ATTACHMENT
Scheduleandtendercondition.pdf
ATTACHMENT
GCC-2022-uptoACS10_merged_compressed.pdf
ATTACHMENT
CHECKLISTFORTENDERERmorethan50Lacs.pdf
ATTACHMENT
TentativeSIP.pdf
ATTACHMENT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged..pdf JPO digging
ATTACHMENT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged..pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .