| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC C O MR M K BHOWMIK NEAR TAPAN VARIETIES JOYNAGAR 06 AGARTALA TRIPURA W 799001 | WEST TRIPURA | TRIPURA | 799001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹7.3 L+₹9,340 (1.30%)Rejected-AOC | L2 | Rejected-AOC HIGHEST BIDDER | |
| 3 | L3₹7.3 L+₹11,910 (1.66%)Rejected-AOC | L3 | Rejected-AOC HIGHEST BIDDER | |
| 4 | L4₹7.3 L+₹13,860 (1.94%)Rejected-AOC | L4 | Rejected-AOC HIGHEST BIDDER | |
| 5 | L5₹7.6 L+₹45,000 (6.28%)Rejected-AOC | L5 | Rejected-AOC HIGHEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
13 Nov 2020, 6:00 pmClosed
AGE (I) AGARTALA
AGE (I) AGARTALA PIN 901184 C/O 99 APO
REPAIR REPLACEMENT AND MAINTENANCE OF COOLING APPLIANCES INCLUDING REPLACEMENT OF WORN OUT ACCESSORIES OF WINDOW TYPE/SPLIT TYPE AIR CONDITIONER WATER COOLER REFRIGERATOR/DEEP FREEZER AND VOLTAGE STABILIZER AT MIL STN AGARTALA
2020_MES_387276_1
8125/E8
Open Tender
Civil Works
Item Rate
180 days
AGARTALA
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE (I) AGARTALA
₹14,000
Yes
14 Dec 2020
17 Oct 2020
16 Nov 2020
17 Oct 2020
13 Nov 2020
30 Oct 2020
Amount
Schedule'A' Part-I: Air Conditioner
Disconnecting electrical connection and taking down/removing unserviceable window type Air conditioner 1.5 or 2.0 Ton capacity of any make and transporting same to MES Yard for annual repair/ servicing / cleaning / maintenance. Dismantling the Air conditioner segregating unserviceable/worn-out parts, carryout repair including replacement of worn out parts, section and reaching line UNSV caliform dismantling and required new fixing, reassembling all components and transporting the same upto its original location, fittings/fixing and making electrical connection including testing for effective cooling all specified and directed. (Note : New spares shall be measured and paid as supply only separately under respective items given here-in-after. However minor spares not mentioned in this schedule and required for smooth functioning of AC are deemed to be included in the quoted rate)
Supply only new starting capacitor of capacity 80/100 mfd suitable for operating voltage 240 volt, 50 HZ all as specified and directed. Make : USHA / GODREJ / UNIVERSAL/L&T /Bajaj/Crompton Greaves
Supply only capacitor 6 mfd of blower motor suitable for operating voltage 240 volt, 50 HZ all as specified and directed. Make : USHA / GODREJ / UNIVERSAL /L&T/Bajaj/Crompton Greaves
Supply only new running capacitor of 36 to 45 mfd suitable for operating voltage 240 Volt, 50 HZ all as specified and directed Make : USHA / L&T / GODREJ / UNIVERSAL/Bajaj/Crompton Greaves.
Supply only new thermostat suitable for any type and make of window Air conditioner 1.5/2 ton capacity all as specified and directed. Make : GODREJ / RENUTROL / WHIRLPOOL/Universal/LG
Supply only new blower motor 0.5 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of window air conditioner of 1.5/2 ton capacity all as specified and directed. MAKE OF BLOWER MOTOR : GODREJ / BAJAJ / VIDEOCON / CARRIER/LG/Samsung
Supply only new swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of window air conditioner of 1.5/2 Ton capacity all as specified and directed. MAKE : GODREJ / VIDEOCON / CARRIER/LG/Samsung
Supply only new starting relay 3 or 4 terminal with connecting leads suitable for any type and make of window air conditioner of 1.5 Ton/2 Ton capacity all as specified and directed. MAKE : RENUTRAL / GODREJ / WHIRLPOOL/LG/Samsung
Supply only new sealed compressor suitable for 1.5 Ton air conditioner of carrier/Videocon/LG having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed. MAKE : KIRLOSKAR / TACHCOMS / CARRIER/LG/VIDEOCON / GODREJ
Supply only new sealed compressor suitable for 2.0 Ton air conditioner of carrier/Videocon/LG having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed. MAKE : KIRLOSKAR / TACHCOMS / CARRIER/LG/VIDEOCON / GODREJ
Taking out unserviceable window type air conditioner 1.5 ton of any type and make after opening the electrical connections, preparing the compressor for refilling and recharging the compressor and M&L for refilling the compressor oil in adequate quantity and recharging the R-134A gas in adequate quantity to achieve effective cooling and refixing the complete component of A/C including refixing the window A/C at its location and testing for effective cooling all as specified and directed.
Taking out unserviceable window type air conditioner 2.0 ton of any type and make after opening the electrical connections, preparing the compressor for refilling and recharging the compressor and M&L for refilling the compressor oil in adequate quantity and recharging the R-134A gas in adequate quantity to achieve effective cooling and refixing the complete component of A/C including refixing the window A/C at its location and testing for effective cooling in all as specified and directed.
Supply only PVC insulated, sheathed flexible multi stranded copper conductor 1100 Volt, 3 core cable of size 40/0.0076 for electrical connection of window A/C, voltage stabilizer and charging sets all as specified and directed. MAKE : FINOLEX / PLAZA / ASIAN
Material & Labour for rewinding of blower fan motor of window type of AC 1.5 TR capacity with proper gauge super enamelled copper wire not less than 300 gm/unit including testing etc all as specified and directed.
Supply only electronic (PCB) for circuit plate suitable for window/Split type AC 1.5/2 ton capacity.
Scrubbing down of old paint from 1.5/2 ton capacity window type AC with emery paper, cleaning, washing, filling cavities, welding, soldering, denting etc and M&L for spray painting to AC unit with two coats of synthetic enamel white paint and after drying writing MES No complete all as specified and directed.
Disconnection electrical connection and taking down/removing unserviceable single phase voltage stabilizer 4 KVA or 5 KVA capacity of any make and transporting same to MES Yard for annual repair/servicing/cleaning/ maintenance. Dismantling the stabilizer segregating unserviceable/worn-out parts, carryout repair including transporting the same upto its original location, fitting/fixing and testing for new spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of refrigerator are deemed to be included in the quoted rate.
(a) Supply only cut off Relay for any type of make voltage stabilizer 4/5 KVA of any type and make.
(b) Supply only electronic (PCB) for circuit plate for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type.
(c) Supply only volt meter for voltage stabilizer 0.5KVA capacity of any make and type.
(d) Supply only control transformer for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type.
Disconnection electrical connection and taking down/removing unserviceable single phase voltage stabilizer 2 KVA or 1 KVA capacity of any make and transporting same to MES Yard for annual repair/servicing/cleaning/ maintenance. Dismantling the stabilizer segregating unserviceable/worn-out parts, carryout repair including transporting the same upto its original location, fitting/fixing and testing for new spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of refrigerator are deemed to be included in the quoted rate.
(a) Supply only cut off Relay for any type of make voltage stabilizer 2/1 KVA of any type and make.
(b) Supply only electronic (PCB) for circuit plate for voltage stabilizer 2 KVA or 1 KVA capacity of any make and type.
(c) Supply only volt meter for voltage stabilizer 0.5KVA capacity of any make and type.
(d) Supply only control transformer for voltage stabilizer 2 KVA or 1 KVA capacity of any make and type.
Disconnection electrical connection and taking down/removing unserviceable single phase voltage stabilizer 0.5 KVA capacity of any make and transporting same to MES Yard for annual repair/servicing/cleaning/ maintenance. Dismantling the stabilizer segregating unserviceable/worn-out parts, carryout repair including transporting the same upto its original location, fitting/fixing and testing for new spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of refrigerator are deemed to be included in the quoted rate.
(a) Supply only cut off Relay for any type of make voltage stabilizer 0.5KVA of any type and make.
(b) Supply only electronic (PCB) for circuit plate for voltage stabilizer 0.5KVA capacity of any make and type.
(c) Supply only volt meter for voltage stabilizer 0.5VA capacity of any make and type.
(d) Supply only control transformer for voltage stabilizer 0.5KVA capacity of any make and type.
SCHEDULE 'A' PART - II ( REFRIGERATOR & DEEPFREEZER)
Disconnecting electrical connection and taking down/removing unserviceable refrigerator/Deep freezer of any capacity of any make and transporting same to MES yard for annual repair/servicing/cleaning/maintenance. Dismantling the refrigerator segregating, unserviceable/worn-out parts, carryout repair, including replacement of worn out parts, reassembling all components and transporting the same upto its original location fitting/fixing and making electrical connection and testing for effective cooling all as specified and directed. (Note: New spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of refrigerator are deemed to be included in the quoted rate in this item.
Supply only new sealed compressor suitable for following capacity of refrigerator having operating voltage 200 to 240 volts, 50 HZ, duly filled compressor oil and M&L for charging of R-134A gas in adequate quantity so that during testing effective cooling can be achieved including making all connections and all as specified and directed. Make : KIRLOSKAR / VOLTAS / GODREJ / WHIRLPOOL/LG
(a) 260 Ltrs Capacity
(b) 280 Ltrs Capacity
(c) 290/300 Ltrs capacity
Supply only new starting relay 3 or 4 terminal with connecting leads suitable for any type and make of refrigerator 300/290/280/260/165 ltrs capacity all as specified and directed. As per sample MAKE : USHA / BAJAJ / VOLTAS / GODREJ / WHIRLPOOL/LG
Supply only new thermostat suitable for any type and make of refrigerator 300/290/280/260 ltrs capacity all as specified and directed. As per sample. MAKE : USHA / BAJAJ / VOLTAS / GODREJ / LG/WHIRLPOOL
Supply only new OLP for any type and make of refrigerator 300/290/280/260 ltrs capacity all as specified and directed. As per sample MAKE : USHA / BAJAJ / VOLTAS / GODREJ / LG/WHIRLPOOL
Supply only new condensing unit suitable for refrigerator of make WHIRLPOOL/ GODREJ/ LG/ SAMSUNH of 300/290/280/260/165 ltrs capacity all as specified and directed. As per sample.
Supply only bio metal timer suitable for refrigeration 280/260/290 ltr capacity. As per sample (Make : Whirlpool/Godrej/Lg/Samsung)
Supply only frost free fan motor suitable for double door refrigeration 280/260/290 ltr capacity. As per sample. (Make : Whirlpool/Godrej/Lg/Samsung)
SCHEDULE 'A' PART - III (WATER COOLER)
Disconnecting electrical connection and taking down/removing unserviceable water cooler of any capacity/type/make and transporting same to MES Yard for annual repair/servicing/cleaning/maintenance. Dismantling the water cooler segregating unserviceable/worn-out parts, carryout repair including replacement of worn out parts, reassembling all components and transporting the same upto its original location, fitting/fixing and making electrical connection and testing for effective cooling all specified and directed by Engineer-in-Charge. Note :- New spares shall be measured and paid as supply only here in after separately. However spare not mentioned in this schedule and required for smooth functioning of water cooler are deemed to be included in the quoted rate.
Supply only new sealed compressor for water cooler of 120/60 ltrs capacity with filling of compressor oil and charging of R-134A gas including testing for effective cooling of water. MAKE : Kirloskar / SriRam / CG / Voltas / Tacmos/Usha/Blue Star
Supply only new sealed compressor for water cooler of 80/40 ltrs capacity with filling of compressor oil and charging of R-134A gas including testing for effective cooling of water. MAKE : KIRLOSKAR / SRIRAM / CG / VOLTAS / TACMOS/USHA/BLUE STAR
Supply only new blower fan motor including fan blade assembly complete in all respect, 240 volt, 50 HZ for any type and make of water cooler having 80/40 ltrs capacity. As per sample. MAKE : VOLTAS / USHA / BAJAJ / CG/BLUE STAR / Sri Ram
Supply only new OLP for water cooler for any type and make of water cooler 80/40 ltr capacity of make : Sriram/Voltas/USHA/Blue star/Kirloskar
Supply only new starting relay for any type and make of water cooler 80/40 ltr capacity . As per sample. MAKE : VOLTAS / USHA / BAJAJ / CG/Sri Ram/Bluestar
Supply only new hose pipe (of dia not less than inlet/outlet pipe) including clamps, check nuts complete all as specified and directed.
Supply only new float valve having brass rod, spindle and PVC ball for water cooler for any type and make of water cooler any make 120/60 or 80/40 ltr capacity as per site requirement all as specified directed . As per sample.
M&L for charging R-134A gas to sealed compressor unit of water cooler of any type and make of unit of water cooler 80/40 ltr capacity complete including testing against leakage and effective cooling all as specified and directed . As per sample.
Supply only new thermostat for 80/40 ltr capacity of water cooler. As per sample. MAKE : USHA / GODREJ / RANUTRIL/Bluestar/Sriram .
Supply only new capillary tube suitable for 120/60 or 80/40 Ltr capacity of water cooler all as specified and directed. As per sample.
Supply only push cook suitable for 120/60 or 80/40 Ltr capacity of water cooler all as specified and directed, As per sample.
Cutting the existing damaged body surfaces of water cooler, including repairing and making good to the surface with 20 gauge MS Sheet by welding, denting, soldering complete and spray painting with synthetic enamel paint of approved tint and after drying writing MES Nos for the following capacity of water cooler incl Unsv handle change with a new including replacement of steel stand complete all as specified and directed
(b) 120/60 Ltrs
Material and Labour for preparation of steel surface of water collar of following capacity by Scrubbing the existing paint with emery paper, washing, filling of cavities removing denting etc and carry out two coat of synthetic enamel paint of approved tint over a coat of red oxide primer including writing MES Nos all as specified and directed.
(b) 120/60 Ltrs
Supply only new capacitor suitable for 40/60 or 80/40 Ltr capacity of water cooler all as specified and directed. As per sample. (Make : Epcos/Maxy/Universal/Usha/Godrej/Bajaj)
Supply only new capacitor suitable for 10/15 or 80/40 Ltr capacity of water cooler all as specified and directed. As per sample (Make : Epcos/Maxy/Universal/Usha/Godrej/Bajaj)
M/S SANKAR GOPE
SHRI RAJESH DEY
SHRI CHANDAN CHANDA
M/S PAUL ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .