Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹5.7 L+₹5,960 (1.05%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹5.9 L+₹21,230 (3.75%)Rejected-Finance | L3 | Rejected-Finance Third lowest |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
15 Feb 2021, 6:00 pmClosed
Major Sameer Wadekar
Holta Camp Palampur GE Palampur Pin 176061
REPAIR/MAINTENANCE OF SOLAR WATER HEATER AND GEYSER AND REPLACEMENT OF ALL CONNECTED ITEMS MCBs DBs SUB MAIN WIRING IN OTM AND MD ACCN AT ALHILAL MIL STN
2021_MES_416086_1
GEP - 2020-21
Open Tender
Civil Works
Item Rate
180 days
Alhilal
As per Tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹15,000
Yes
26 Mar 2021
25 Jan 2021
17 Feb 2021
25 Jan 2021
15 Feb 2021
1 Feb 2021
Amount
Taking down sub main wiring any type and any capacity with casing caping /concealed conduit/batten conduit complete all as directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Serviceing of geyser of 25 ltrs capacity storage type electric water heater by disconnecting & opening inspection , taking down opening (dismantantling), descaling, brushing cleaning of storage tank and painting internally with one coat of proprietary bituminious compositions not liable to impart taste or oudour or otherwise contaminate the water, examine water tightness of storage tank after cleaning, carry out operation of all stopcocks, pressure-reducing valves etc to ensure free movement of the working parts, replace washers and glands of all taps and ball valves to ensure wtare tightness, Inspect overflow /vent pipes and remove blockages obstructions if any, Check and correct earth continutity, checking of plugs, descaling of the immersion type heating element and cleaning with diluted gydrochloric acid or clear pedette, replacement of neon indicating lamps if required , replacement of the rubber PVC gaskets to ensure water tightness etc and change effective parts as required complete all as specified and directed. Note:- All defective or unserviceable spare parts change during serviceing shall be measure and paid saperately as supply only
Serviceing of geyser of 50 ltrs capacity storage type electric water heater by disconnecting & opening inspection , taking down opening (dismantantling), descaling, brushing cleaning of storage tank and painting internally with one coat of proprietary bituminious compositions not liable to impart taste or oudour or otherwise contaminate the water, examine water tightness of storage tank after cleaning, carry out operation of all stopcocks, pressure-reducing valves etc to ensure free movement of the working parts, replace washers and glands of all taps and ball valves to ensure wtare tightness, Inspect overflow /vent pipes and remove blockages obstructions if any, Check and correct earth continutity, checking of plugs, descaling of the immersion type heating element and cleaning with diluted gydrochloric acid or clear pedette, replacement of neon indicating lamps if required , replacement of the rubber PVC gaskets to ensure water tightness etc and change effective parts as required complete all as specified and directed. Note:- All defective or unserviceable spare parts change during serviceing shall be measure and paid saperately as supply only
Supply only heat collector strip (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of heat collector strip (as per existing make and size) for solar water heater of 300/400 litre capacity complete all as specified and directed.
Supply only tank mixture valve (as per existing make and size) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement of tank mixture valve (as per existing make and size) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
Supply only heat exchanger (as per existing make and size) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement of heat exchanger (as per existing make and size) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
Supply only tubing collector (as per existing make and size) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement of tubing collector (as per existing make and size) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F cover sheet for protection of hot water tank for solar water heater of 200 litres capacity including taking down old un-serviceable cover sheet complete all as specified and directed.(as per existng size and make)
Supply only cover sheet for protection of hot water tank for solar water heater of 200 litres capacity complete all as specified and directed.(as per existng size and make)
Supply only cover sheet for protection of hot water tank for solar water heater of 300 litres capacity complete all as specified and directed.(as per existng size and make)
S&F cover sheet for protection of hot water tank for solar water heater of 300 litres capacity including taking down old un-serviceable cover sheet complete all as specified and directed.(as per existng size and make)
Supply only siphon assembly for electric storage type geyser including connection and testing complete all as specified and directed. (As per existing holes)
S&F in replacement siphon assembly for electric storage type geyser including connection and testing complete all as specified and directed. (As per existing holes)
S&F in replacement glass wool for electric geyser storage type complete all as specified and directed.
S&F in replacement PVC sheathed three core copper conductor flexible wire of size 40/0.0076 complete all as specified and directed
Supply only outer body of electric geyser storage type 25 litre capacity duly white painted complete all as specified and directed.
S&F in replacement outer body of electric geyser storage type 25 litre capacity duly white painted complete all as specified and directed.
Supply only outer body of electric geyser storage type 50 litre capacity duly white painted complete all as specified and directed.
S&F in replacement outer body of electric geyser storage type 50 litre capacity duly white painted complete all as specified and directed.
Supply only 1.50 Kw heating element for electric storage type geyser including connection and testing complete all as specified and directed.
S&F in replacement 1.50 Kw heating element for electric storage type geyser including connection and testing complete all as specified and directed.
Supply only 2.0 Kw heating element for electric storage type geyser including connection and testing complete all as specified and directed.
S&F in replacement 2.0 Kw heating element for electric storage type geyser including connection and testing complete all as specified and directed.
Supply only copper geyser tank 25 litre capacity for electric storage type geyser including leakage testing complete all as specified and directed.
S&F in replacement copper geyser tank 25 litre capacity for electric storage type geyser including leakage testing complete all as specified and directed.
Supply only copper geyser tank 50 litre capacity for electric storage type geyser including leakage testing complete all as specified and directed.
S&F in replacement copper geyser tank 50 litre capacity for electric storage type geyser including leakage testing complete all as specified and directed.
Supply only thermostate for electric storage type 25 ltrs capacity geyser including connection and testing complete all as specified and directed.
S&F in replacement thermostate for electric storage type 25 ltrs capacity geyser including connection and testing complete all as specified and directed.
Supply only thermostate for electric storage type 50 ltrs capacity geyser including connection and testing complete all as specified and directed.
S&F in replacement thermostate for electric storage type 50 ltrs capacity geyser including connection and testing complete all as specified and directed.
S&F in replacement 15mm bore non return valve for electric geyser storage type complete all as specified and directed.
S&F in replacement 20mm bore non return valve for electric geyser storage type complete all as specified and directed.
Supply only pressure release valve/Safety valve for electric geyser storage type complete all as specified and directed.
S&F in replacement pressure release valve/Safety valve for electric geyser storage type complete all as specified and directed.
S&F in replacement 450mm long stainless steel flexible water connection pipe for electric storage type geyser including leakage testing complete all as specified and directed.
S&F in replacement 15mm bore brass cromium plated stop cock for electric geyser storage type complete all as specified and directed.
Supply only top cover for 25 ltrs capacity geyser complete all as specified and directed.(as per existng size and make)
S&F in replacement of top cover for 25 ltrs capacity geyser complete all as specified and directed.(as per existng size and make)
Supply only top cover for 50 ltrs capacity geyser complete all as specified and directed.(as per existng size and make)
S&F in replacement of top cover for 50 ltrs capacity geyser complete all as specified and directed.(as per existng size and make)
S&F in replacement 3 pin plug top of capacity 15 Amp AC 240 Volts 50 Hz complete all as specified and directed.
Taking down old unserviceable electric storage water heater any type/size, supply and installation of electric storage water heater (vertical type geyser minimum 5 star rating, 50 ltr capacity 240 V, AC single phase having stainless steel inner tank incl heavy duty pin type fasteners 4" long and PVC flexible connection pipe as per site requirement incl plug in top 15 amp and making necessary inlet/outlet water connection and making good disturbed surface of walls to match with existing surface complete all as specified. Note-old unserviceable electric water heater to be deposited in MES store yard.
Taking down old unserviceable electric storage water heater any type/size, supply and installation of electric storage water heater (vertical type geyser minimum 5 star rating, 25 ltr capacity 240 V, AC single phase having stainless steel inner tank incl heavy duty pin type fasteners 4" long and PVC flexible connection pipe as per site requirement incl plug in top 15 amp and making necessary inlet/outlet water connection and making good disturbed surface of walls to match with existing surface complete all as specified. Note-old unserviceable electric water heater to be deposited in MES store yard.
S&F in replacement sheet metal enclosures two pin and earth plug and socket complete with one single pole MCB 20 Amps C type 240 Volts complete all as specified and directed.
M&L Wiring for circuit / submain wiring in PVC casing caping along with 4.00Sqmm earth wire with 2 x 4.00 Sqmm FRLS-H PVC insulated unsheathed 1100 volts grade multi-stranded copper conductor, single core cable complete all as specified and directed.
S&F Factory made DB SPN 8 way double door,240 Volt with 200 Amps rated bus bar concealed in wall IP42/ 43 protection for fixing MCB complete all as specified and directed.
S&F MCB SPN ‘C’ curve, 10KA 40 to 63 amps including necessary connection complete all as specified and directed.
S&F MCB SPN ‘C’ curve, 10KA 6 to 32 amps including necessary connection complete all as specified and directed.
Disconnecting & opening of solar water heater storage type of 200/300/400 capacity, desclaing with chemical and pressure pump, change the un-serviceable parts, re-assembling the same,testing complete all as specified and directed. Note:- All defective or unserviceable spare parts change during serviceing shall be measure and paid saperately as supply only
Supply only tuffen glass of heat collector for solar water heater 200/300/400 litre capacity including taking out old un-serviceable or brocken glass complete all as specified and directed.
S&F in repair tuffen glass of heat collector for solar water heater 200/300/400 litre capacity including taking out old un-serviceable or brocken glass complete all as specified and directed.
Supply only hot water tank suitable for solar water heater of 200 litres capacity complete all as specified and directed.(as per existng size and make)
S&F in repair hot water tank suitable for solar water heater of 200 litres capacity complete all as specified and directed.(as per existng size and make)
Supply only hot water tank suitable for solar water heater of 300 litres capacity complete all as specified and directed.(as per existng size and make)
S&F in repair hot water tank suitable for solar water heater of 300 litres capacity complete all as specified and directed.(as per existng size and make)
Supply only hot water tank suitable for solar water heater of 400 litres capacity complete all as specified and directed.(as per existng size and make)
S&F in repair hot water tank suitable for solar water heater of 400 litres capacity complete all as specified and directed.(as per existng size and make)
Supply only rubber hose pipe of existing size, length and make for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement of rubber hose pipe of existing size, length and make for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
Supply only heating element 3 Kw of existing make for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement heating element 3 Kw of existing make for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
Supply only rubber flange of 25mm dia with nut, bolt and washer for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement rubber flange of 25mm dia with nut, bolt and washer for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
Supply only flange gasket (as per sample) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement of flange gasket (as per sample) for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
Supply only thermostat 0 to 80 degree 11'' long of existing make for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
S&F in replacement thermostat 0 to 80 degree 11'' long of existing make for solar water heater of 200/300/400 litre capacity complete all as specified and directed.
M&L soldering to copper pipe / hot water tank to rectify the leakage in solar water heater complete all as specified and directed.
Supply only solar flat plate collector suitable for 200/300/400 capacity solar water heater complete all as specified and directed. (As per existing holes)
S&F in repair solar flat plate collector suitable for 200/300/400 capacity solar water heater complete all as specified and directed. (As per existing holes)
M/s Sheetal Associates
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .