Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.8 L+₹56,397.30 (1.60%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹35.9 L+₹60,292.80 (1.71%)Rejected-Finance SATGOAN BAZAR NEAR BUS STAND GUWAHATI ASSAM 27 | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹37.6 L+₹2.3 L (6.63%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹39.4 L+₹4.2 L (11.8%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L5 | Rejected-Finance Unsuccessful bidder |
| Sl No | Description | Qty | Unit | K K Construction Co L6 | M/S H. I. ENTERPRISE L1 | LAXMI & GANESH ENTERPRISE L3 | sanjay upadhya L4 | BCL L2 | M/S SEWAK SINGH L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation in soft/loose soil n.exc 30cm deep and averaging 15 cm deep and getting out complete all as specified and as directed. | 110 | Sqm | 185 ₹20,350 | 45 ₹4,950 | 20 ₹2,200 Lowest | 25 ₹2,750 | 30 ₹3,300 | 40 ₹4,400 |
| 2.00 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m depth; for plinth beam, n exc 10 sq m on plan and n exc1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. | 108 | Cum | 285 ₹30,780 | 350 ₹37,800 | 300 ₹32,400 | 200 ₹21,600 Lowest | 300 ₹32,400 | 200 ₹21,600 Lowest |
| 3.00 | M&L for cement concrete Type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete. complete all as specified and as directed. | 6 | Cum | 4,850 ₹29,100 | 5,000 ₹30,000 | 5,000 ₹30,000 | 4,500 ₹27,000 | 5,500 ₹33,000 | 4,200 ₹25,200 Lowest |
| 4.00 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical, complete all as specified and as directed | 121.84 | Sqm | 400 ₹48,736 | 290 ₹35,333.6 | 200 ₹24,368 | 150 ₹18,276 Lowest | 250 ₹30,460 | 250 ₹30,460 |
| 5.00 | M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed. | 28.8 | Sqm | 450 ₹12,960 | 550 ₹15,840 | 200 ₹5,760 Lowest | 250 ₹7,200 | 250 ₹7,200 | 250 ₹7,200 |
| 6.00 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed.
NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. | 32.72 | Cum | 10,500 ₹3,43,560 | 7,000 ₹2,29,040 Lowest | 8,000 ₹2,61,760 | 7,500 ₹2,45,400 | 8,000 ₹2,61,760 | 8,500 ₹2,78,120 |
| 7.00 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed.
NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. | 6.2 | Cum | 12,000 ₹74,400 | 8,000 ₹49,600 Lowest | 8,000 ₹49,600 Lowest | 8,000 ₹49,600 Lowest | 8,500 ₹52,700 | 8,500 ₹52,700 |
| 8.00 | M&L Reinforced Cement Concrete (Design Mix) M-25 as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like etc, complete all as specified and as directed.
NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. | 12.6 | Cum | 12,200 ₹1,53,720 | 6,500 ₹81,900 Lowest | 8,000 ₹1,00,800 | 8,500 ₹1,07,100 | 8,500 ₹1,07,100 | 8,500 ₹1,07,100 |
| 9.00 | M&L for RCC M-25 for Slabs Beams, cantilevers, bressummers, lintels over 1.5m span,complete all as specified and as directed.
NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. | 10.17 | Cum | 12,280 ₹1,24,887.6 | 7,500 ₹76,275 Lowest | 8,000 ₹81,360 | 8,500 ₹86,445 | 8,500 ₹86,445 | 9,000 ₹91,530 |
| 10.00 | M&L Reinforced Cement Concrete (Design Mix) M-25 as in Chajjas and similar works complete all as specified and as directed.
NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. | 0.4 | Cum | 12,500 ₹5,000 | 8,500 ₹3,400 Lowest | 9,000 ₹3,600 | 10,500 ₹4,200 | 8,500 ₹3,400 Lowest | 8,500 ₹3,400 Lowest |
Tender Value
₹45.9 L
EMD Value
₹92,000
Closing Date
1 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
PROVISION OF CERTAIN SANCTION WORK AT (PHASE III) OF VARIOUS UNIT AT MISA CAMP UNDER GE (S) TEZPUR
2025_MES_729208_1
CWE/TEZ(S)/T-49 of 25-26
Open Tender
Civil Works
Item Rate
180 days
GE (S) Tezpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (S) Tezpur
₹92,000
Yes
8 Dec 2025
3 Sept 2025
3 Oct 2025
3 Sept 2025
1 Oct 2025
17 Sept 2025
Amount
Surface excavation in soft/loose soil n.exc 30cm deep and averaging 15 cm deep and getting out complete all as specified and as directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m depth; for plinth beam, n exc 10 sq m on plan and n exc1.5 m in depth and getting out soft/loose soil complete all as specified and as directed.
M&L for cement concrete Type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete. complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical, complete all as specified and as directed
M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed.
M&L Reinforced Cement Concrete (Design Mix) M-25 in Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L Reinforced Cement Concrete (Design Mix) M-25 in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L Reinforced Cement Concrete (Design Mix) M-25 as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like etc, complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L for RCC M-25 for Slabs Beams, cantilevers, bressummers, lintels over 1.5m span,complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L Reinforced Cement Concrete (Design Mix) M-25 as in Chajjas and similar works complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L for TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
M&L for TMT Bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required,including cranking, bending spirally for hooping for columns, hooping ends and binding, complete all as specified and as directed.
Returning filling inl.spreading, levelling, watering and well ramming in layers n. exc. 25 cm in hard/dense soil, complete all as specified and as directed.
Removing excavated material (Soil) n exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed.
M & L for use and waste formwork to sides and soffit of suspended slabs such as roof slab, floor slabs, etc. with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
Material & labour for formwork to sides and soffits of concrete of beam, lintels, cantilevers etc. with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
Material & labour for formwork to as in chajjas with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
M&L for cement concrete Type C2 1:3:6 (40mm graded aggregate) in floor, filling and mass concrete. complete all as specified and as directed.
M & L Hardcore of guage exc 63mm but n exc 150mm deposited spread and levelled in layers n. exc 7.5cm thick, with broken stone, watered and rolled/rammed to a true surface, complete all as specified and as directed.
M&L for Sand filling 250 mm thick under floors or infoundations including watering and consolidation ,complete all as specified and as directed.
M & L for Polythene film, black, 150 micron laid in floor ,complete all as specified and as directed.
M/L 75mm thick P.C.C 1:4:8 type D-2 using 40mm graded stone aggregate finished even and smooth without using extra cementas in plinth protection / sub base/ etc complete all as specified and directed.
Forming contraction (Dummy) joints 65 mm deep x 10 mm wide filled with Grade 'A' sealing compound complete all as specified and as directed.
S&F vitrified Ceramic tiles 10 mm thick area of each tile not exceeding 0.36 sqm, in floors etc. set OVER 15mm thick screed bed in CM 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
All as per Item No.24 above but on skirting over 10mm thick backing coat in CM 1:4, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed.
M&L for 15 mm thick screed bed in cm 1:3 mixed with WPC as per manufactures instruction finished even and smooth over RCC roof slab without using extra cement (WPC shall be measured seperately) complete all as specified and as directed.
M & L for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:- (a) Preparing and clening of fully dry surfaces as per IS3067-1966 (b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm (c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.0Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.
M&L for taking down of existing Roof treatment from roof and fence and covering surface of old concrete roof by picking , sweeping clena and washing down with water remove dust, etc and applying roof treatement with the following specifications: (a) Rendering 15mm thick in cm (1:4) fixed with water proofing compound as per manufacturers instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plaster surfaces for 7 days by ponding water over the roof (leveling coure) (b) Applying evenly one coat of cold bituminous primer conforming to IS- 3384-1088@ 0.30 litre per sqm on th cleaned plastered surfaces (c) Applying layer of APP based polymeric membrane 3mm th (minimum) weighing 3.50 kg per sqm (reinforced with polyster non woven fabric weighing not less than 160 gms per sqm by torch application . The overlap shall not less than 100mm onn the reverse direction and 75mm longitudinal direction and sealing overlaps. (d) Applying evenly one coat of aluminium paint of 0.10 ltr sqm over APP based polymeric membrane.
Demolition of brick work built in cement mortar including all quions, arches pillars etc, complete all as specified and as directed.
M&L brick work with sub class B brick straight orcurved on plan exc 6 mtr mean radius in cm (1:6) complete all as specified and directed.
M & L for Rendering 15mm thick cement mortar 1:4 on fair faces of brick work or concrete sur?faces even and smooth, complete all as specified and directed.
M&L for rendering 20 mm thick in CM 1:4 on other than fair faces of brick or concrete surfaces with water proofing compound @3% of weight of cement and finishing the surface even and smooth (without using extra cement) complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separately
Supply only integral WPC.
M & L for rendering 5mm thick cement mortar 1:3 on fair faces of brick work or concrete surfaces even and smooth on ceiling including prepation of new plastered surface complete all as specified & directed
M&L Preparing new Surfaces of Walls and applying Two coats of exterior emulsion antifungus paint over a coat of primer and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L three coats of white washing to ceiling including preparation of new surfaces, complete all as specified and directed.
M&L Preparing new Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two coats of exterior emulsion antifungus paint over a coat of primer and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L one coat of white wash over old decorative surface internal wall including after complete removal of existing treatment complete all as specified & directed.
M&L one coat of white wash over old decorative surface ceiling including after complete removal of existing treatment complete all as specified & directed.
M&L Preparing Old Wood and Wood Based Surfaces of any description, nexc 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed.
Taking down chowkhats incl shutterrs (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4 sqm each, complete all as specified and as directed.
S & F powder coated Anodised aluminium frame for doors, three track windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed.
S & F powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc, complete all as specified and as directed.
Materials and Labour for mid steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and as directed.
S/F 4mm thick ordinary quality sheet glass in squares exc 0.5 sqm in each pane fixed in aluminium frame complete all as specified & directed
S/F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm fitted with tinned tacles or galvanised wire staples complete all as specified and as directed.
M&L Steel Work in Tubular /hollow section as in Trusses and post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-4923 grade YSt.-240 complete all as specified and as directed.
M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with L type J type or cranked hook bolts, complete all as specified and as directed.
M&L for preparation old painted surfaces of steel and iron surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M&L Prepolished Coloured Cement Concrete designers Chequered Tiles 300 x 300x 25 mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete including 15 mm thick screed bed in CM (1:6), complete all as specified and as directed.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories i PVC box or modular GI/PVC boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Chase cutting deemed to be included in quoted rate.
All as per item No.54 above but one 3 pin 5 amps switch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No.54 above but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including PVC box /fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc or modular GI boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit with all fittings and accessories of conduit pipe (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. or modular GI boxes of suitable size for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.. (ii) Chase cutting deemed to be included in quoted rate.
M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, suitable for metal flush box, modular cover plate with frame of suitable size of 3M and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.. (ii) Chase cutting deemed to be included in quoted rate.
S&F Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed.
S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
S&F Modular type switch 16 Amps 230V AC single module one way complete all as specified and as directed.
Material and labour for ceiling rose polycarbonate isolated body 3 ways terminals omplete all as specified and as directed.
S&F Modular type fan regulator Step type,100 Watt, one module/ two module, 230V AC complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed.
Supply and fixing modular metal flush box 3 modules complete all as specified and as directed.
Supply and fixing modular metal flush box 4 modules complete all as specified and as directed.
Supply and fixing modular metal flush box 6 modules complete all as specified and as directed.
Supply and fixing modular metal flush box 8 modules complete all as specified and as directed.
Supply and fixed switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
Supply & fixing Modular type 25 Amps power unit combine with on/off switch complete all as specified and directed.
Supplying and fixing two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked) concealed including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. Note : Two run of 6 sqmm wire with one run of 6 sqmm and one run of conduit pipe shall be measured against one unit.
Supply and fixed18 W LED light fitting wall mounted batten 4'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed.
Supply and fixed10 W LED light fitting wall mounted batten 2'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 10 watt,6500K including necessary connection complete all as specified and directed.
Supply and fixed security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
Supply and fixing LED decorative wall light made up of high grade engineering plastic material suitable for LED 20W complete as per manufacturer's instructions all as specified and directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door , Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fixed MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Supply and fixed MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as directed.
S & F ventilating exhaust fan 300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed.
Supply & installing air cooled split type air conditioner (indoor and outdoor) electric driven complete with cordless remote control unit and built Air ioniser and Plasma filter for better indoor air quality with mimimum 5 star rating and EER 3.2 single phase of capaity 2.0 TR.
Supply & installing air cooled split type air conditioner (indoor and outdoor) electric driven complete with cordless remote control unit and built Air ioniser and Plasma filter for better indoor air quality with mimimum 5 star rating and EER 3.2 single phase of capaity 1.5 TR.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable 95 Sqmm X 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge for the following ratings Note:- (i) Excavation,sand cushioning,brick will be measured and paid separtely.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15 cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry width wise across the line of cable in trenches for protection of UG cable including dismantaling of old unservieacble bricks complete.
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified. Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor's firm name while carrying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
BCL (BID ID -3434284)
LAXMI & GANESH ENTERPRISE (BID ID -3434059)
sanjay upadhya (BID ID -3434662)
M/S SEWAK SINGH (BID ID -3428706)
K K Construction Co (BID ID -3438633)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .