Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | ₹33.5 L Quoted ₹34.1 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹34.2 L+₹9,031.50 (0.26%)Rejected-Finance CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹34.2 L+₹9,031.50 (0.26%) | L2 | Rejected-Finance Become L2 |
| 3 | L3₹37.2 L+₹3.1 L (9.10%)Rejected-Finance | ₹37.2 L+₹3.1 L (9.10%) | L3 | Rejected-Finance Become L3 |
| 4 | L4₹37.4 L+₹3.2 L (9.49%)Rejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹37.4 L+₹3.2 L (9.49%) | L4 | Rejected-Finance Become L4 |
| 5 | L5₹38.1 L+₹4.0 L (11.6%)Rejected-Finance NIL | ₹38.1 L+₹4.0 L (11.6%) | L5 | Rejected-Finance Become L5 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
14 Jun 2022, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur, Assam
REPAIR TO SUBMAIN WIRING SERVICE/UG CABLE/MCB DB AT SAA, REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND OTHER ALLIED WORKS AT 3A, 3B AND REPAIR STREET/SECURITY AND GARDEN LIGHTS AT ZONE-1(A,B,C) AND ZONE 3 (A,B) UNDER GE (S) TEZPUR
2022_MES_518665_2
8651
Open Tender
Civil Works
Item Rate
180 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹70,000
Yes
14 Jul 2022
7 Jun 2022
16 Jun 2022
7 Jun 2022
14 Jun 2022
8 Jun 2022
Amount
M&L for rewinding of ceiling fan,1200mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings (both) and new capacitort. complete all as specified and directed
Ditto as in Item No 1 as above but for ceiling fan of 1400mm size
Ditto as in Item No 1 as above but for Exhaust fan of 200/225 mm size
Ditto as in Item No 1 as above but for Exhaust fan of 300/400 mm size
M&L for painting of fan (ceiling fan / exhaust fan/wall mounted fan ) any sweep with applying one coat of synthetic enamel paint (Ceiling Fan -White Paint and Exhaust fan - Gray Paint ) by spray machine including preparation of old painted surfaces with filling of cavity by filler with and including writting of MES No. of fan in capital letters with black synthetic enamel paint of height not less than 20mm on fan body in approved pattern complete all as specified and directed.
Supply and Fix in repair louver shutter (with Mosquito net made out GI wire cloth 0.36 mm nominal dia ) made out GI sheet (Thickness of louver shutter Body 1mm ,shutter Fins 0.5 mm fixed with 3 mm GI wire ) for Exhaust fan 300/400 mm sweep including proper fixing with screw in wall at existing Hole including taking down old unsv louver shutter complete all as specified and directed.
S & F in repair Ball bearing (Bearing No- 6201/6202) of ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv bearing complete all as specified and directed .
S & F in repair Capacitor( 2.5-4) MFD for ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv capacitor.complete all as specified and directed
S & F in repair Down rod 15mm bore medium grade GI pipe including cut in required length and drilled as per existing size including taking down old unsv down rod complete all as specified and directed.
S & F in repair Fan blade for Ceiling fan of 1200mm sweep of white colour including taking down old unsv fan blade complete all as specified and drected.
S & F in repair Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed by Engineer-in-charge.
S & F in repair Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 6 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed by Engineer-in-charge .
S & F in repair Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed by Engineer-in-charge .
S & F in repair Power line vertical type TPN DB double door 4 way, IP 43 suitable for MCCB 100 amps CRCA sheet metal enclouser with detachable gland plates for flush / surface mounting with bus bar neutral link and Earth Bar in concealed and all disturbed surfaces of wall shall be made good to match the existing wall finishes complete all as specified and directed.
S & F in repair MCB SP 6 to 32 Amp, C series , 230 Volts complete all as specified and directed .
S & F in repair MCB DP 6 to 32 Amps, C series, 230 Volts complete all as specified and directed .
S & F in repair MCB DP 40-63 Amps, C series, 230 Volts complete all as specified and directed.
S & F in repair MCB TPN 40-63 Amps, C series, 10 KA "B" series 415 Volt complete all as specified and directed.
S & F in repair MCCB 4 Pole 415V Fixed type 25-100A with breaking capicity 16 KA complete all as specified and directed.
Taking down the existing U S wiring carefully of aluminium/copper point wiring (light, fan, bell, socket, power point etc.) with conduit/casing caping, along with all connected accessories complete all as directed.
M&L for point wiring complete for One light point with 1.5 Sqmm single core multistranded copper conductor FR PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through PVC casing caping including provn of 1.5 sqmm single core multistranded copper conductor FR PVC insulated and unsheathed as earth wire continuity including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition) complete all as specified and directed.
Ditto as per Item No 21 above but for one fan point
Ditto as per Item No 21 above but for One 3 pin 5 Amp socket outlet on the same board
Ditto as per Item No 21 above but for One 3 pin 5 Amps socket out let on independent board
Ditto as per Item No 21 above but with 2 x 2.5 Sqmm +1 x 1.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board.
Ditto as per Item No 21 above but for one bell point controlled by one 5 amp switch
Ditto as per Item No 21 above but for one light point controlled by two two way switches
S & F in repair electronic fan regulator,100W ,230V ,50Hz stepped socket type for ceiling fan complete all as specified .
S&F in repair switch piano type, 5 Amp. SP, one way all as directed/ specified.
S&F in repair switch piano type, 15 Amp. SP, one way all as directed/ specified. Make-
S&F in repair switch socket outlet, 2 in one 5 pin, 5 Amp, piano type all as directed/ specified. Make-
S&F in repair switch socket combination 2 in 1, 6 pin 5 and 15 Amp flush type universal all as directed/ specified.
S&F in repair switch bell push, flush type, 5 Amp all as directed/ specified.
S&F in repair bell, AC, 230 V, SP, ding dong type all as directed & specified. Make Anchor/leader/ Bajaj
S&F in repair of Ceiling rose 3 phase, PVC/ Polycarbonate body all as directed/ specified.
S&F in repair switch two way switch flush type, 5 Amp all as directed/ specified.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 105 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and directed.
M&L in repair laminated sheet or hylam sheet for mounting, switches, sockets, fan regulator etc. of any size as per site requirement complete all as specified and directed.
Supply and laying or fixing or passing throgh pipe including taking down ,1100 Volts grade heavy duty cable with with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq mm 4 core nominal cross section in service connection complete all as specified and directed.
Ditto as per Item No 42 above but for size 10 sq mm 4 core.
S & in repair PVC casing caping of any size complete all as specified and directed.
M & L for Point wiring for one light point with 1.5 sqmm PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and new non metallic PVC rigid conduit and conduit accessories, medium grade, ISI marking, concealed Frame for fixing switches, sockets, inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable FR grade as in earth wire for continuity and connecting to earth dolly for one light point controlled by one switch complete including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the wall (wash/paint/distemper) wherever required(as per the existing condition) all as specified and directed Note - The cost of modular metal flush box and Modular white Cover Plate with Frame, MS terminal boxes, laminated hylem sheet if required shall be deemed to be included in the unit rate.
Ditto as per Item No 45 above but for one fan point
Ditto asper Item No 45 above but for One 3 pin 5 Amp socket outlet on the same board
Ditto as per Item No 45 above but for One 3 pin 5 Amps socket out let on independent board
Ditto as per Item No 45 above but with 2 x 2.5 Sqmm +1 x 1.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board.
Ditto as per Item No 45 above but for one bell point controlled by one, one 5 amp switch
S&F in repair modular switch flush type, 6 Amp. SP, one way ,1 module all as directed specified.
S&F in repair modular socket outlet, 3 pin, 6 Amp, flush type 2 module all as directed/ specified.
S&F in repair modular switch, 16 Amp flush type 1 module all as directed/ specified.
S&F in repair modular socket outlet, 3 pin, 6/16 Amp flush type 2 module all as directed/ specified.
S&F in repair modular bell push, flush type, 5 Amp,1 module all as directed/ specified.
S&F in repair modular Fan Regulator step type 2 module ,120W all as directed/ specified.
Taking down old unsv submain wiring of any size complete all as specified and directed
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4 Sq mm drawn through PVC Casing Caping and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.
ditto as in Item No-58 above but for 2x6.0 sqmm+1x6.0sqmm earth wire
S& F in repair exhaust fan of sweep 200/250 mm PVC Body including taking down existing old unseviceable Exhaust fan and taking to MES Store as specified and directed. Make- Crompton/Havells/Bajaj/Usha
S& F in repair exhaust fan of sweep 225/300 mm light duty Metal Anti Dust Coating including taking down existing old unseviceable Exhaust fan and taking to MES Store as specified and directed. Make-Cromton/Havells/Bajaj/Usha
S & F in repair 9 Watt LED bulb fitting, colour temp 6500k, including taking down old unserviceable type bulb all as specified and directed by Engr in charge . make-Havells /phillips/bajaj
S & F in repair angle bulb holder for LED fitting, including taking down old unserviceable type holder all as specified and directed by Engr in charge.
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 10W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting. Make Havells Philips/Havells/CG .
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 20W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per Make Havells hilips/Havells/CG.
S & F in repair 12 Watt LED fitting Recess mounted downlighter (Round/Square) with independent electronic LED driver ensuring glare free light with all its surface module accessories including taking down old unserviceable type downlighter including taking down unsv light fittings comlpete all as specified and directed. make-Havells/phillips/bajaj
M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth wire 4mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge. Note: 1.The above quoted rate shall include cost of main earthing wire 4mm dia charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate. 3. The cost of taking down old unsv earthing with all its accessories is deemed to be included in the unit price.
S & F in repair connection pipe (both hot & cold) of any size as per site requirement for geyser of any capacity complete all as specified and directed. Note- Both hot and cold pipes are deemed to be one unit.
Supply and fix in repair Heating element of 1500/2000 watts suitable for 25 ltrs capacity water heater including taking down old unsv element complete all as specified and directed.
S & F in repair Thermostat of range 0-80 degree Celsius suitable for 25 Ltrs water heater including taking down old unsv thermostat complete all as specified and directed.
Supply and fixing in repair recessed dust free LED fitting 36 watts size(2X2)'' soft light glare free homogenous illumination very high efficiency enviormental friendly long life complete making all connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed. Make :- Havells hilips/Havells/CG.
S&F in replacement road/ security light/bldg light with high power LED fitting as light source ,energy saving envoirmental friendly 30 W with advance features all as complete with fixing arrangement such as GI pipe brakets bend in 120 degree, clamps made out by GI strip suitable for steel or PCC poles, nuts ,bolts and washer to be fixing incl making all eclectrical connection with three core flexible copper cable etc specified and directed.
Ditto as per Item No 73 above but for 45W.
Supply and fixing in replacemnt of LED decorative garden post top lantern cap 15 watts with opal acryliwith IP 65 protection warm white Cylindrical LED bollard rings contemporary style and unique design toghter for indirect glare- free lighting. including making all connection using 3 core copper flexible cable drawn through in PVC conduit (if required) complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair LED Floret Decorative wall light suitable for 9 watts very high efficiency enviormental friendly long life mounting on PVC round/square PVC block and making all connection using PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed. Make :- Havells cat No.LHFHCHE1TL1W020/ or its equivalent in phillips/bajaj
Supply and Fixing in repairs TRACK mounted LED light with modern design compact size with High power COB LED 15W to provide focussed light.
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in hard/dense soil for poles foundation complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and as directed.
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
M&L for sand cushioning with clean dry sand for protection of under ground cable complete all as specified and as directed. Note :- Punned thickness of sand layer shall be measured and paid to contractor.
M&L for Brick Sub Class 'B' locally available best quality laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection complete all as specified and as directed.
Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps concealed in wall all a directed. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
MAHANTA ENTERPRISES
M/S Manjit Singh
Anil Kumar Sarmah
M/S N S CONSTRUCTION
M/S Deep-Jeet
DRISTEE ASSOCIATES
M/s Brahamaputra Wood Industries
D G Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .