| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹31.6 L+₹2.6 L (8.94%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹33.0 L+₹4.1 L (14.0%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹33.3 L+₹4.3 L (14.9%)Rejected-AOC 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹33.4 L+₹4.4 L (15.4%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | sri sai ram constructions L3 | RAGHU RAMA PANDA L6 | TECHNO SOFT SOLUTIONS L10 | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L11 | Sri Shiridi Sai Engineering L1 | MVV Prasad L4 | SREE DURGA INFOTECH L9 | V R K CONSTRUCTIONS L12 | G.APPALANAIDU L5 | prasad constructions L2 | NAVEEN INFRASTRUCTURES L8 | K.ADITYA ENGINEERING CONTRACTORS L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01NOTE: THE TENDER SHALL NOTE BEFORE QUOTING HIS UNITS RATE,ALL ITEMS OF WORKS SHALL BE EXECUTED IN HIGH RISE BUILDING UPTO 9TH FLOOR AND PROVISION OF NECESSARY SCAFFOLDING AND SAFETY MEASURES SHALL BE DEEMED TO BE INCLUDED IN THE RATE QUOTED BY THE CONTRACTOR OR FIRM. | |||||||||||||||
| .02SCHEDULE 'A' PART-I: B/R WORKS | |||||||||||||||
| 1.00 | M&L Cleaning and removing all scale and dirt, etc, from PVC and RCC water tanks of capacity exc 250 ltrs but n. exc 500 ltrs and from mouths of circulating pipes, etc including washing the tank with clean water and applying bleaching powder after removing scales, dirt complete all as specified and as directed by the Engineer-in-charge Note: (i) Quoted rate shall deemed to be included for writing details of "Tank cleaned on ________ (date)" with height of each letter not less than 10cm (ii) An register shall be maintained by the Engineer-in-charge to obtain the signatures of users in token of completion of cleaning of each water tank and the same shall be kept in record and shall be produced alongside RAR/FB at the time of payment. | 65 | Each | 360 ₹23,400 | 556 ₹36,140 | 606 ₹39,390 | 617 ₹40,105 | 407 ₹26,455 | 350 ₹22,750 | 598 ₹38,870 | 625 ₹40,625 | 300 ₹19,500 Lowest | 349 ₹22,685 | 592 ₹38,480 | 584 ₹37,960 |
| 2.00 | M&L Cleaning and removing all scale and dirt, etc, from PVC and RCC water tanks of capacity exc 500 ltrs but n. exc 1000 ltrs and from mouths of circulating pipes, etc including washing the tank with clean water and applying bleaching powder after removing scales, dirt complete all as specified and as directed by the Engineer-in-charge Note: (i) Quoted rate shall deemed to be included for writing details of "Tank cleaned on ________ (date)" with height of each letter not less than 10cm (ii) An register shall be maintained by the Engineer-in-charge to obtain the signatures of users in token of completion of cleaning of each water tank and the same shall be kept in record and shall be produced alongside RAR/FB at the time of payment. | 933 | Each | 460 ₹4,29,180 | 718 ₹6,69,894 | 775 ₹7,23,075 | 817 ₹7,62,261 | 307 ₹2,86,431 Lowest | 530 ₹4,94,490 | 725 ₹6,76,425 | 835 ₹7,79,055 | 400 ₹3,73,200 | 403 ₹3,75,999 | 784 ₹7,31,472 | 715 ₹6,67,095 |
| 3.00 | M&L Cleaning and removing all scale and dirt, etc, from PVC and RCC water tanks of capacity exc 1000 ltrs but n. exc 2000 ltrs and from mouths of circulating pipes, etc including washing the tank with clean water and applying bleaching powder after removing scales, dirt complete all as specified and as directed by the Engineer-in-charge Note: (i) Quoted rate shall deemed to be included for writing details of "Tank cleaned on ________ (date)" with height of each letter not less than 10cm (ii) An register shall be maintained by the Engineer-in-charge to obtain the signatures of users in token of completion of cleaning of each water tank and the same shall be kept in record and shall be produced alongside RAR/FB at the time of payment. | 24 | Each | 510 ₹12,240 Lowest | 925 ₹22,200 | 1,008 ₹24,192 | 1,027 ₹24,648 | 999 ₹23,976 | 1,000 ₹24,000 | 994 ₹23,856 | 1,050 ₹25,200 | 600 ₹14,400 | 883 ₹21,192 | 986 ₹23,664 | 901 ₹21,624 |
| 4.00 | S&F in repairs rotational moulded polyethylene water storage tanks 2 multi layered ISI Marked (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I. | 30 | Each | 6,600 ₹1,98,000 | 4,957 ₹1,48,710 Lowest | 5,403 ₹1,62,090 | 5,502 ₹1,65,060 | 5,977 ₹1,79,310 | 6,800 ₹2,04,000 | 5,329 ₹1,59,870 | 5,640 ₹1,69,200 | 7,500 ₹2,25,000 | 5,005 ₹1,50,150 | 5,279 ₹1,58,370 | 5,205 ₹1,56,150 |
| 5.00 | S&F in repairs rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I. | 50 | Each | 11,600 ₹5,80,000 | 9,259 ₹4,62,950 | 10,092 ₹5,04,600 | 10,227 ₹5,11,350 | 9,977 ₹4,98,850 | 10,200 ₹5,10,000 | 9,953 ₹4,97,650 | 10,500 ₹5,25,000 | 12,000 ₹6,00,000 | 9,100 ₹4,55,000 Lowest | 9,861 ₹4,93,050 | 9,300 ₹4,65,000 |
| 6.00 | S&F in repairs rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 2000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I. | 4 | Each | 22,500 ₹90,000 | 18,997 ₹75,988 | 20,707 ₹82,828 | 21,087 ₹84,348 | 20,007 ₹80,028 | 15,000 ₹60,000 Lowest | 20,422 ₹81,688 | 21,600 ₹86,400 | 22,000 ₹88,000 | 19,000 ₹76,000 | 16,999 ₹67,996 | 19,946 ₹79,784 |
| 7.00 | Demolition of 1000 Litres capacity RCC water tanks including RCC cover slab and removing of demoished mateials outside the MD land all as specified and as directed. | 50 | Each | 1,080 ₹54,000 | 2,059 ₹1,02,950 | 2,244 ₹1,12,200 | 2,285 ₹1,14,250 | 497 ₹24,850 | 535 ₹26,750 | 2,213 ₹1,10,650 | 2,340 ₹1,17,000 | 400 ₹20,000 Lowest | 2,800 ₹1,40,000 | 2,193 ₹1,09,650 | 2,162 ₹1,08,100 |
| 8.00 | S&F rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I. | 50 | Each | 13,500 ₹6,75,000 | 8,899 ₹4,44,950 | 9,700 ₹4,85,000 | 9,878 ₹4,93,900 | 9,977 ₹4,98,850 | 12,000 ₹6,00,000 | 9,566 ₹4,78,300 | 10,124.95 ₹5,06,247.5 | 12,000 ₹6,00,000 | 9,100 ₹4,55,000 | 8,155 ₹4,07,750 Lowest | 9,200 ₹4,60,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Oct 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
CLEANING OF WATER TANKS AND CONNECTED REPAIRS TO VERTICAL PIPE LINE AT ASHOKA PARK PALLAV PARK WED CTW NSB OLD MOV NAMAC AND CSD UNDER AGE BR III OF GE ND VISAKHAPATNAM
2025_MES_727508_1
8508/GEND/E8
Open Tender
Civil Works
Item Rate
240 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹80,000
Yes
8 Jan 2026
11 Sept 2025
6 Oct 2025
11 Sept 2025
3 Oct 2025
26 Sept 2025
Amount
NOTE: THE TENDER SHALL NOTE BEFORE QUOTING HIS UNITS RATE,ALL ITEMS OF WORKS SHALL BE EXECUTED IN HIGH RISE BUILDING UPTO 9TH FLOOR AND PROVISION OF NECESSARY SCAFFOLDING AND SAFETY MEASURES SHALL BE DEEMED TO BE INCLUDED IN THE RATE QUOTED BY THE CONTRACTOR OR FIRM.
SCHEDULE 'A' PART-I: B/R WORKS
M&L Cleaning and removing all scale and dirt, etc, from PVC and RCC water tanks of capacity exc 250 ltrs but n. exc 500 ltrs and from mouths of circulating pipes, etc including washing the tank with clean water and applying bleaching powder after removing scales, dirt complete all as specified and as directed by the Engineer-in-charge Note: (i) Quoted rate shall deemed to be included for writing details of "Tank cleaned on ________ (date)" with height of each letter not less than 10cm (ii) An register shall be maintained by the Engineer-in-charge to obtain the signatures of users in token of completion of cleaning of each water tank and the same shall be kept in record and shall be produced alongside RAR/FB at the time of payment.
M&L Cleaning and removing all scale and dirt, etc, from PVC and RCC water tanks of capacity exc 500 ltrs but n. exc 1000 ltrs and from mouths of circulating pipes, etc including washing the tank with clean water and applying bleaching powder after removing scales, dirt complete all as specified and as directed by the Engineer-in-charge Note: (i) Quoted rate shall deemed to be included for writing details of "Tank cleaned on ________ (date)" with height of each letter not less than 10cm (ii) An register shall be maintained by the Engineer-in-charge to obtain the signatures of users in token of completion of cleaning of each water tank and the same shall be kept in record and shall be produced alongside RAR/FB at the time of payment.
M&L Cleaning and removing all scale and dirt, etc, from PVC and RCC water tanks of capacity exc 1000 ltrs but n. exc 2000 ltrs and from mouths of circulating pipes, etc including washing the tank with clean water and applying bleaching powder after removing scales, dirt complete all as specified and as directed by the Engineer-in-charge Note: (i) Quoted rate shall deemed to be included for writing details of "Tank cleaned on ________ (date)" with height of each letter not less than 10cm (ii) An register shall be maintained by the Engineer-in-charge to obtain the signatures of users in token of completion of cleaning of each water tank and the same shall be kept in record and shall be produced alongside RAR/FB at the time of payment.
S&F in repairs rotational moulded polyethylene water storage tanks 2 multi layered ISI Marked (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I.
S&F in repairs rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I.
S&F in repairs rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 2000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I.
Demolition of 1000 Litres capacity RCC water tanks including RCC cover slab and removing of demoished mateials outside the MD land all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks 2 layered ISI Marked (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I.
Supply and laying 25 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete including taking up or down of 20 mm dia steel tubing upto 4th floor all as specified.
Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete including taking up or down of 20 mm dia steel tubing upto 4th floor all as specified.
Supply and laying 16 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down of 15 mm dia steel tubing upto 4th floor all as specified.
S & F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed.
S&F 20 mm dia ball valves, PTMT high pressure of epoxy coated Aluminium rod and high density plastic ball (200 gms) complete, screwed for iron pipes or brasas ferrule and fixed.
S&F 25 mm dia ball valves, PTMT high pressure of epoxy coated Aluminium rod and high density plastic ball (200 gms) complete, screwed for iron pipes or brasas ferrule and fixed.
M&L Providing, cement concrete in Type B1 (using 20 mm graded stone aggregate) as in water tank bed for PVC water tank including necessary formwork all as specified and as directed.
Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises.
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match oloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes.
Glazed ceramic coloured tiles in vertical surfaces 450x 350x 7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match incl sreed bed 10 mm thick in CM 1:4 .
S&F in repairs 10 Ltrs. Capacity PVC flusing cistern low level slimline or equivalen make / model with all accessories.complete all as specified and directed
S&F PVC connection of size 15mm, 450mm long with PTMT Nuts complete all as specified and directed
S & F in repair vitreous China squatting pan white orissa pattern size 580x440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron P trap including lime concrete bedding and making good the disturbed portion to match with the existing finishes of floor all as specified and directed.Make : Parry ware/CERA/Hind Ware
S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed
S&F in repair Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges.complete all as specified and directed
S&F in repairs for 15 mm dia bore angle tap .
S & F in repairs 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
Taking down of existinng roof treatment from roof and terrance, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following specification:- (a) Applying cement slurry over concrete surfaces @ 3 kg/sqm.(b) M&L 25 mm thick cement concrete PCC Type B0 1:2:4 using 12.5 mm graded aggregate on roof slab (c) Rendring 15mm thick in cement mortar (1:4) mixed with water proffing compound as per manufactures instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course).(d) Applying evenly one coat of cold bituminous primer conforming to [email protected] liter per square metre on the cleaned plastered surfaces (e) Applying evenly one coat of blown hot bitumen of grade 85/25@ 1.20 Kg per square metre on primed surfaces.(f) Applying a layer of APP based polymeric membrane, 3mm thick (minimum)Weighing 3.50 Kg per square metre reinforces) with polyster non woven fabric wighing not less than 160 gms per square metre by torch application. The overlap shall be not less than 100mm on transverese direction and 75 mm on longitudinal direction and sealing overlaps.(g) Applying evenly one coat of Aluminium paint @ 0.10 litre per square metre over the APP based polymeric membrane at 5th floor complete all as specified and directed
prasad constructions (BID ID -3438736)
sri sai ram constructions (BID ID -3436905)
MVV Prasad (BID ID -3441535)
G.APPALANAIDU (BID ID -3440435)
RAGHU RAMA PANDA (BID ID -3438223)
K.ADITYA ENGINEERING CONTRACTORS (BID ID -3440656)
NAVEEN INFRASTRUCTURES (BID ID -3439987)
SREE DURGA INFOTECH (BID ID -3441642)
TECHNO SOFT SOLUTIONS (BID ID -3439201)
M/S SRI VENKATA BHAVANI CONSTRUCTIONS (BID ID -3439234)
V R K CONSTRUCTIONS (BID ID -3441391)
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .