Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC NAPITPARA PURULIA DIST PURULIA PIN 723103 | PURULIA | PURULIA | WEST BENGAL | 723103 | L1 | Accepted-AOC Due to lowest. | |
| 2 | L2₹14.2 L+₹1.1 L (8.03%)Rejected-Finance KANKARDANGA | L2 | Rejected-Finance Due to 2nd lowest. | |
| 3 | L3₹14.8 L+₹1.6 L (12.1%)Rejected-Finance SADAR PARA PS PURULIA T DIST PURULIA PIN 723101 W B | PURULIA | PURULIA | WEST BENGAL | 723101 | L3 | Rejected-Finance Due to 3rd lowest. | |
| 4 | L4₹14.9 L+₹1.7 L (12.9%)Rejected-Finance SADARPARA P O PURULIA P S PURULIA TOWN DIST PURULIA PIN 723101 | PURULIA | PURULIA | WEST BENGAL | 723101 | L4 | Rejected-Finance Due to 4th lowest. | |
| 5 | L5₹15.0 L+₹1.8 L (13.7%)Rejected-Finance VILL ABASH CHOTO BARDIA GRAM ABASH P S KOTWALI ABASH 721102 | MEDINIPUR WEST | WEST BENGAL | 721102 | L5 | Rejected-Finance Due to 5th lowest. |
Tender Value
Refer Docs
EMD Value
₹31,956
Closing Date
5 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_Prl Elect Division PWD
Ranchi Road, Purulia
Repairing and renovation of internal and external electrical installation work at Govt Model School_Balarampur_ Purulia in the District of Purulia_ Project ID_ES232412906S000
2024_WBPWD_646619_1
WBPWD/EE/PED/NIQ30/2023-2024
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹31,956
12 Dec 2025
15 Jan 2024
8 Feb 2024
22 Jan 2024
5 Feb 2024
22 Jan 2024
Amount
Supply & installation of CPRI approved Cubical Type Compartmentalized floor mounted LT panel board of suitable size and shape for extension of existing LT panel board and made of 2mm thick CRCA sheet, angle/ flat iron for structural frame work & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint having copper Bus-bar and following equipment & accessories. Protection required of panel is IP-54.
INCOMING:- 200A 415 V TPN switch disconnector fuse unit (L&T ) with 3 nos. of din type HRC fuses—3 nos. Necy. electrolytic tinned copper bars of Adequate size on suitable insulation must be provided for outgoing cable connection. - 1 set
Bus-bar :- a) 415V 400A Horizontal Bus-bar chamber to Vertical Busbar Chamber of hinged type door of electrolyte tinned copper bar with EPR support for main power distribution supply power to individual section from Bus-bar with suitable size electrolytic tinned copper bar all joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves.
Outgoing::-a) 100 A 415V TPN switch disconnector fuse unit (L&TCat No-SK95568) with 3 nos. of din type HRC fuses—2 nos. Necy. electrolytic tinned copper bars of Adequate size on suitable insulation must be provided for outgoing cable connection. --2 Set B)-a) 32 A 415V TPN switch disconnector fuse unit (L&T Cat No-SK95642) with 3 nos. of din type HRC fuses—2 nos. Necy. electrolytic tinned copper bars of Adequate size on suitable insulation must be provided for outgoing cable connection. --2 Set
iii)LED type indicating lamp(RYB) with sliding fuses- 3 set
iv)CTs of range 200/5 amps-3 sets
v) frequency meter -1 set (L&T Cat No-WL1130400000)
Constructional Details:-The panel to be made by 2mm thick CRCA sheet. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from bottom of the panel and it should be compartmentalized. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 600mm width along the vertical. The panel shall have suitable size integral and removable lifting lug in required nos. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted. The material and design should be approved by EIC before fabrication. [NS]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
4 way Enclosure (607913) [Make :Legrand/L&T/Hager] [D-11/15]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [NS]
4 way Enclosure (607715) [Make :Legrand/L&T/Hager] [D-10/14]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection,on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.and necy. connection with socket and gland
2+12 way Enclosure (607712) [Make :Legrand/L&T/Hager] [D-9/13]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.[D-8/10]
100 A [Make :Legrand/L&T/Hager] [D-8/10]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
40 A DP [Make :Legrand/L&T/Hager] [D-5/6]
63 A FP [Make :Legrand/L&T/Hager] [D-5/6]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
63 A, TP, [Make :Legrand/L&T/Hager] for VTPN DB [D-6/7]
6-32 A, SP, [Make :Legrand/L&T/Hager] for PDB and VTPN and SPN[ D-6/7]
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [E-14/2]
Average run 8 mtr [E-14/2(c)]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish[E-15/4]
On Board [E-15/4(a)]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required [E-14/1(a)]
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1(a)(i)]
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1(a)(ii)]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [E-14/1(a)(iv)]
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.[C-2/15]
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.[C-2/14(a)]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[C-3/21(a)]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[C-2/16]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
30 cm Exhaust fan (12") D-14/33(a)
Supply of 4' 22W T8 LED tube light with complete set (Make:- Philips TMC 502 P 1xT-LED 22W P3241, Master LED Light 1200mm 18w865 ) Price List 2023
Supply of 48" sweep A.C. ceiling fan complete with all accessories. (Make: Usha ,Orient ) [NS]
Supply of 15'' sweep AC exhaust fan (EPC heavy duty/ Usha turbo LD DBB) 1050 r.p.m. and S& F louver with nuts and bolts.[NS]
Supply of 12'' sweep AC exhaust fan (EPC heavy duty/ Usha turbo LD DBB) 1370 r.p.m. and S& F louver with nuts and bolts.[NS]
Supply of 9'' sweep AC exhaust fan (EPC heavy duty/ Usha turbo LD DBB) 1420 r.p.m. and S& F louver with nuts and bolts.[NS]
Supply of 9 watt LED lamp (Make- Philips/Crompton)[NS]
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991 [D-14/29]
Excavation of soil for installation of Earth Electrode and filling & ramming.
For Morrum Soil [G-1/1(b)]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe [G-1/2(a)]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [G-2/4(a)]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Solid GI Wire No. 4 SWG [G-2/5(a)(i)]
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required [E-4/12]
175 mm x 100 mm x 65 mm [E-4/12(c)]
240 mm x 200 mm x 65 mm [E-4/12(e)]
300 mm x 200 mm x 65 mm [E-4/12(g)
Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-5/14(b)
Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-5/14(a)
Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. [E-5/15(a)]
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-7/25]
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. [E-5/15(b)]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make :- Gloster/ Havells] -4 Core 25 sqmm (456x0.77)
2 core 10 sq mm [ NS ] (251x0.77
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core 70 sqmm [F-4/7(b)]
4 Core 25 sqmm[F-4/7(b)]
2 Core 10 sqmm [F-4/7(a)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 Core 70 sqmm [F-5/8(b)(vii)]
4 Core 25 sqmm [F-5/8(b)(xiii)]
2 Core 10 sqmm [F-5/8(b)(iii)]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting [F-1/2(a)]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(b)]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(d)]
Supply & Fixing of 70 watt LED street light(Make -Philips/Havells/ Crompton) incl. all necy connection as per direction of EIC.[Cat No-TRP-409-70-57-SL-GL-NSG) [NS] Price List 2023
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting.200 x 150 x 100mm. [I-2/16]
S&F of 40 mm. dia. 1.5 Mts. long G.I. pipe (medium) arm bracket grouted by 4 nos. 5” long GI nut bolt & 2 nos. “U” clamp arrangement on wall with S&F 1 no. 40 mm X 20 mm reducer.as per G.S. [NS]
Supply & Fixing 3 phase DOL type starter incl necy connection as per GS. [Make-L&T Cat No-SS91854COEO,or eqvt make of Havells , crompton)[ NS]
Supply & Fixing MF1 starter street light Control [NS] ( Make- L&T Cat No-SS9722700CO)
S&F timer for one no. machine febricated with double door 8Way SPNDB as per L&T Cat no-LTSDO8N) i) 240 V, 32A DP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)-1no ii) 22A TP power contactor with 220 coil voltage (L&T, Cat no-MNX22-2P, CS90238)-1 No. iii) Digital timer switch (L&T, cat no-Crono 67DDTO)-1no [NS]-
Concealing of existing all switch boards , VTPNDBs , TPNDBs , SPNDBs and also detection of all electrical connection and fixing of Ph & N connector of all switch boards etc including rectification of distribution wiring as per direction of EIC. [NS]
SASTIK ENTERPRISE
RAHUL TRADERS
SAIBAL SARKAR
SREE LALJI
TARUN DEY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .