Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹437 CrAccepted-AOC 626 6TH FLOOR DLF TOWER A DLF TOWER 626 6TH FLOOR DLF TOWER A JASOLA JASOLA SOUTH DELHI DELHI 110076 | SOUTH DELHI | DELHI | 110076 | ₹437 Cr | 1 | Accepted-AOC Successful bidder |
| Sl No | Description | Qty | Unit | Jakson Limited L1 |
|---|---|---|---|---|
| 1.00Isolators and Accessories | ||||
| 1.01 | 245KV, 3150A, 50kA for 3 sec, Horizontal Double Break type Isolator with double earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings | 4 | Set | 14,86,307 ₹59.5 L |
| 1.02 | 145KV, 2000A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors | 2 | Sets | 7,50,614 ₹15.0 L |
| 1.03 | 145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors | 12 | Sets | 7,04,459 ₹84.5 L |
| 1.04 | 145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators,Clamps & Connectors | 16 | Sets | 5,60,661 ₹89.7 L |
| 2.00 | 145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch (tandem type) complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors | 6 | Sets | 5,71,484 ₹34.3 L |
| 2.01 | 72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with one earth switch complete with manual and motor driven operating mechanisms along with Support Insulators,Clamps & Connectors and Hardware Fittings | 2 | Set | 4,28,845 ₹8.6 L |
| 2.02 | 72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings | 2 | Set | 3,54,627 ₹7.1 L |
| 2.03 | 33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings | 2 | Set | 2,71,594 ₹5.4 L |
| 2.04 | 33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings | 3 | Set | 2,26,135 ₹6.8 L |
Tender Value
Refer Docs
EMD Value
₹4 Cr
Closing Date
27 Jun 2024, 2:00 pmClosed
CGM PPD
O/O THE MD, AEGCL
Construction of 220/132kV, 2X160 MVA GIS at Rowta along with associated Transmission Lines
2024_AEGEF_36848_1
AEGCL/PKG-P-II-A/2023/P-II-A
Open Tender
Power/Energy Projects/Products
1095 days
ROWTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹50,000
₹4 Cr
Yes
8 Oct 2025
2 Mar 2024
28 Jun 2024
2 Mar 2024
27 Jun 2024
23 Apr 2024
2 Mar 2024 - 12 Mar 2024
Amount
Isolators and Accessories
245KV, 3150A, 50kA for 3 sec, Horizontal Double Break type Isolator with double earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
145KV, 2000A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators,Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch (tandem type) complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with one earth switch complete with manual and motor driven operating mechanisms along with Support Insulators,Clamps & Connectors and Hardware Fittings
72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
Insulators, hardware & Conductors
220kV, 2x120kN double tension string Antifog insulators and hardwares suitable for Single Zebra conductors
220kV, 2x120kN double suspension string Antifog insulators and hardwares suitable for Twin Moose conductors
132kV, 2 x160kN double tension string Antifog insulators and hardwares suitable for Twin MOOSE conductors
132kV, 2 x120kN double suspension string Antifog insulators and hardwares suitable for Twin MOOSE conductors
132kV,120kN single suspension string Antifog insulators and hardwares suitable for Single MOOSE conductors
ACSR Moose Conductor
Clamps, Connectors and Hardware fittings (as per site requirement)
245KV, 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
145 KV, 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
72.5 kV , 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
Station Service Transformer
500 KVA, 33/0.433kV StationTransformer (Energy Efficiency Level 3) , including Clamps & Connectors
250 KVA, 33/0.433kV StationTransformer (Energy Efficiency Level 3) , including Clamps & Connectors
Power receiving panel with 440V MCCB of adequate rating for Station Service Transformer
Surge Arrester
216kV, 10kA, LA complete with Surge Monitor, hardware fittings, clamp & connectors as per specification
120kV, 10kA, LA complete with Surge Monitor, hardware fittings, clamps & connectors as per specification
60kV, 10kA, LA with surge counter, hardware fittings, clamps & connectors as per specification
30kV, 10kA, LA with surge counter, hardware fittings, clamps & connectors as per specification
CVT and Wave Trap
220kV, 4400pF, 3 Wdg CVT, complete with Junction Box, hardware fittings, clamps & connectors
220KV, 1250A Wave Trap complete with hardware fittings and clamps and connectors.
132kV, 4400pF, 3 Wdg CVT, complete with Junction Box, hardware fittings, clamps & connectors
132KV, 800A Wave Trap complete with all accessories
Circuit Breaker
145 kV, 3150 A, SCR 40 kA for 3 sec, SF6 Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure with 10 % spare SF-6 gas.
72.5 kV 3150 A, SCR 40 kA for 3 sec, SF6 Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure with 10 % spare SF-6 gas.
36 kV 1250 A, SCR 31.5 kA for 3 sec, Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure
Bay Marshalling Kiosk along with support structures
220kV Bay Marshalling Kiosk
132 kV Bay Marshalling Kiosk
Instrument Transformers along with junction box and all other accessories
132KV, 1200-1000/1-1-1-1-1 A Current Transformer
132KV, 600-400/1-1-1-1-1 A Current Transformer
132KV, 1600-1200-800/1-1-1-1-1 A Current Transformer
132 kV Potential Transformer
72.5 kV 50-25/1-1-1-1-1 A Current Transformer
72.5 kV Potential Transformer
Control, Relay & Protection Panel(Simplex Type)
245kV GIS
Bus Bar Control and Protection Panel
Line Control and Protection Panel
Transformer Control and Protection Panel
Bus Coupler Control and Protection Panel
145kV AIS
Line Control and Protection Panel
Transformer Control and Protection Panel
Bus Coupler Control and Protection Panel
Bus Bar Control and Protection Panel
72.5 kV AIS
Station Service Transformer Control and Protection Panel
Relevant software for relay configuration & setting, maintenance etc.
Relay Maintenance Tool Kit as per Clause 14.48 of Volume II
33 kV AIS
Capacitor Bank Control and Protection Panel
Complete Substation System Automation System (As per specification )
Bay Control Units for 220kV Bays
Bay Control Units for 132kV Bays
Bay Control Units for 72.5 kV Bays
Station HMI (Main, Redundant and Metering)
Maintenance HMI (DR Workstation)
Gate way with PLCC and Fibre Optic Modem and Panel
5 kVA SAS Inverter
UPS with separate 220 V Battery Bank
Colour Laser Printer
Dot Matrix Printer
Line Printer
GPS Clock System
Bay Ethernet Switch
Station Ethernet Switch
All interphase equipment for Gateway to SLDC
All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
RTU Panel
Aux BCUs as per scheme requirement
SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
27 Inch LCD Monitor (Industrial)
Annual Maintenance Contract (AMC) as per clause 15.30 of Vol II
Supply of 245 kV GIS
245 kV GIS Equipment
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Line bay module as per technical specification
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Transformer bay module (HV of 160MVA Transformer) as per technical specification
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Bus Coupler bay module as per technical specification
245kV, Three number, 1-phase (isolated units)/3 phase unit, SF6 gas insulated metal enclosed 50kA for 3 sec, Bus Bar module as per technical specifications
245kV extension module (both 3-phase and 1-phase) complete with all requirements for necessary bus extension
245kV, 3150A, 50 kA for 3 sec, 1- phase SF6 to air bushings along with termination module & support structure for outdoor connections to connect GIS with 245kV side of Power transformer and overhead lines
245kV, 3150A, 50kA for 3 second, 1-Ph, SF6 Gas Insulated Bus Duct (GIB) outside GIS hall including Bus Duct support structure and associated accessories and jointing elements
7.5 Ton EOT Crane (Double Girder) for 245kV GIS Building
Supply, Testing And Maintenance Equipment of GIS as specified
Online Partial Discharge Monitoring Unit
SF6 gas quality testing unit
SF6 Gas Leak Detector
Precision Pressure Gauge
SF6 Gas Evacuation Plant with Processing, Drying, Storage and Filling Unit (One mobile cart and one static cart)
Video Borescope
SF6 gas Mask
160MVA, 220/132/33kV, ONAN/ ONAF/OFAF/ODAF, 3 Phase Auto Transformer along with all accessories as below:
160 MVA, 220/132/33 kV, Three phase Auto Transformer with OLTC (including Transformer oil)
Oil & winding temperature monitoring system (FO based)
Online DGA
Online insulating drying system
Digital RTCC Panel
10% Extra OIL for each transformer
Terminal connector on 220kV side bushing of 220/132 kV Transformer to suit Twin Moose conductor
Terminal connector on 132kV side bushing of 220/132kV Transformer to suit Twin Moose conductor
Single phase HV side 3 core bushing phase CT (1000/1A, 2 core) and 1 core for WTI
Single phase IV side 3 core bushing phase CT (1000/1A, 2 core) and 1 core for WTI
Single phase bushing mounted NCT (1000/1A, 3 core)
Rail Track for Transformer
Pulling Block for Transformer
Mounting Structures (Lattice/pipe)
245 kV Isolator with double earth switch
145 kV Isolator with single earth switch
145 kV Isolator without earth switch
145 kV Isolator (tandem type)
72.5 kV Isolator (with earth switch)
72.5 kV Isolator (without earth switch)
245 kV CVT
145 kV CVT
Battery & Battery Chargers, DCDB & ACDB as per specification
220V VRLA Battery, 600AH
220V, Dual Float Cum Boost Chargers, 150A
220V, DCDB
48V VRLA type Battery Bank, 300 AH
48V, 60A Modular SMPS based Dual Float cum Boost Chargers
48V, DCDB
Main ACDB
Sub ACDB
MLDB with 415V/415V, 100kVA isolation transformer
ELDB with 415V/415V, 50kVA isolation transformer
HVAC DB
MCBDB
Auxiliary ACDBs, Sub DCDBs etc as per requirement
110 V DCDB for existing Rowta GSS
415 V ACDB for existing Rowta GSS
Power Line Carrier Communication Equipments (Twin Channel, 8kHz)
HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 150 km ) for 220kV
Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 150 km ) for 132kV
IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with relay, E1 interface card and optical interface card to support 150 km(220kV)
IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with relay, E1 interface card and optical interface card to support 150 km(132 kV)
EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
LMU and LMDU
Armoured Audio Cable
CAT 6 armoured cable.
Walkie talkie handset to operate seamlessly within a radius of 1km using license free band. (Motorola or better)
Two wire telephone set
132 kV XLPE Cable and Termination Kit as per specification
1000 sqmm, 132kV, 1-Core, XLPE Armoured Cu cable alongwith related accessories
132kV Cable Termination Kit along with its accessories and related structure for outdoor type.
Design, Manufacture and supply of Single Core Straight Through Jointing Kit including Cross Bonding with all consumables for 1000 sq mm 132 KV XLPE Armoured Cu underground cable
Supply of three phase link boxes with SVL and 6.6 KV grade XLPE cable suitable for 132 KV XLPE Armoured Cu under ground single core 1000 sq mm XLPE cable for earthing at cable sealing end Terminations and straight through joint with all related accessories as required.
Supply of Single phase link boxes without SVL and 6.6 KV grade XLPE cable suitable for 132 KV XLPE Armoured Cu under ground single core 1000 sq mm XLPE cable for earthing at cable sealing end Terminations and straight through joint with all related accessories as required.
Supply of cable route marker, cable tags, cable phase identification band, jointing marker, clamp connector, trefoil clamp of nylon with neoprene gasket, warning tape, lugs, danger plate, phase plate, circuit marker ,GI Flats, Electrodes ,Earthing Materials, Trefoil Clamps for 132kV Cable etc.
Supply of DTS (Distributed Temperature Sensor) including DTS system for real time thermal monitoring of single core 1000 sqmm underground XLPE cable
Supply of Galvanized steel structures for cable pot-head termination.
Bonding cable of relevant size to suit 132kV 1000sqmm XLPE Cu Cbale as per calculation
Other Cable accessories (perforated and ladder cable trays, insert plates, MS curb angles etc) as per requirement.
XLPE Armoured Cu, LT Power Cable (1.1kV grade)
2C, 6sqmm
4C, 16sqmm
3.5C, 35sqmm
3.5C, 70sqmm
3.5C, 400sqmm
Other Cables as per technical specification not covered above
Cable supports and other cable accessories
Others ( Cable for Fire Fighting, Illumination, CCTV etc)
PVC Armoured Cu LT Control Cable (1.1 kV grade)
2C, 2.5sqmm
4C, 2.5sqmm
7C, 2.5sqmm
12C, 2.5sqmm
17C, 2.5sqmm
19C, 2.5sqmm
Other Cables as per technical specification not covered above
Cable supports and other cable accessories
Others ( Cable for Fire Fighting, Illumination, CCTV etc)
Multi Modular Cable sealing system for all cable entries at 220kV GIS building, Control room, Kiosk building, FFPH building etc. as per requirement.
Earthing
Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
Main Earthing Conductor 40mm dia MS Rod
Earthing Conductor: 40mm dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure Etc)
Earthing Conductor: 75X12mm GI Flat For Equipment and Structure Earthing
Earthing Conductor: 50X10Mm GI(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
Earthing Device & Associated Accessories (50 Mm dia Heavy Duty Gi Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI cover)
Earthing Device & Associated Accessories 40Mm dia Ms Rod 3 Mtrs Long For Non Treated Earth Pit with CI cover)
50x8 mm, 50x6 mm, 25x6mm GI Flat as per site requirement
Soil Resistivity Test And Soil Treatment As And When Required
Separate Earthing For 245 Kv GIS Modules (including multi-point earthing)
Separate Earthing For 245 kV GIS Building (with Cu flat of adequate size for GIS earth mat)
Separate Earthing For Control room building
Separate Earthing For Fencing Around The Substation
Auxiliary/Satellite Earth mat wherever applicable
Other Earthing Accessories ( required for complete earthing of the entire switchyard and the buildings)
Supply of Galvanised Lattice structures
220kV Column
220kV Beam
132kV Column
132kV Beam
Foundation Bolts (Including nuts,checknut & washers for lattice and pipe structures)
Fastners(nuts, bolts and washers) including step bolts for lattice and pipe structures
HVAC & VENTILATION
Industrial Air conditioning system for 220kV GIS Building, Control room building.
2 TON CAPACITY SPLIT AIR CONDITIONING UNITS for Control Room Building ( Battery room , Engineer Room , JE Room, Electrical room, Conference room and SCADA room) Including all CRP/LCP housing room of the GIS Halls, having N+1 or N+2 Standby Requirements for Battery Room, CRP/LCP Housing Room and SCADA Room only.
Ventilation system for 245kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
Fire Alarm & Detection
Fire Alarm & Detection system for 245kV GIS Building and related rooms, Control Room building and other related rooms including Fire Alarm panel, Multi Sensor detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling and ISOLATING MODULE as per specification.
Portable and wheel/trolley mounted Fire Extinguishers for Control Room Building and Switchyard as per specification and Portable Fire Extinguisher for GIS Hall (5kg X 6Nos and 2kg X5 Nos), Officer Quarter (2kg X 6Nos), Staff Quarter (2kg X 6Nos), Security Barrack (2kg X 6Nos),Guard room (Security Booth) (2kg X 3Nos), Store Building (2kg x5) as per specification.
Trolley mounted portable fire exinguishers (Dry powder chemical type) for 500 kVA transformers ( 10 Kg , DCP Type)
Hydrant & HVWS (High Velocity Water Spray) system/NIFPES
Hydrant system along with pumping arrangement & associated Civil works for fire protection system for 2 No of Transformer
HVWS system for 160 MVA Auto Transformer-2 No’s
NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 2 Nos ICT
250 KVA, Silent DG Set with AMF including Panel & Accessories including earthing arrangement
Lighting System
Indoor Lighting
Lighting System including Lighting panel, distribution boards, Cabling, Conduiting, Switches, Socket, Junction boxes, auxiliary receptacle, High bay fixtures for GIS rooms
245 kV GIS Building
Control Room Building
FFPH Building
Pump House
Security booth
Security barrack
Staff Quarter, Officer Quarter, store building & open store shed
Outoor Lighting
Outdoor LED lighting for Switchyard, Road area, Car parking, Security outpost including Lighting panel, Distribution Boards, Cabling, Switches, Socket, auxiliary receptacle, complete with GI Poles etc.
Public Addressing System, CCTV for both new wand existing switchyards with 75'' VDU
Lightning protection (lightning masts 50 metres high, Lightning Spike, shield wires (7/4 mm GI shield wire), down conductors etc.)
Miscellaneous item(like MS Channel,Angle, Rail, Chequered plate,MS Grill plate, Lugs and Glands,HDPE Pipes Switchyard and Bay Identification Name board, Anchor fastner and Display for Overall single line diagram photo with frame.etc…as per site requirement)
Training
Trainiing as per different Clauses of Volume II of BID Document
Additional items required for completion of the project
Tenderer(s) to specify
Description of Work / Item(s)
Amount
De-stringing of ACSR Conductor as per site requirement and shifting the same to existing store building
Dismantling of existing control room building, DG set foundation and all other nearby equipments/buildings as per site requirement
Dismantling of LT lines as per site requirement
Dismantling of quarters, store room, workshop room, RE office, temple etc as per site requirement
Site Clearance including necessary excavation
Site preparation
Shifting of 12.5 MVA Transformer (scrap)
Shifting of all the spare materials, store materials and other scrap items as per site requirement
Shifting of items from existing control room building and re commissioning at new control room building
SCADA System (all related accessories)
NIPFS System Control Panel
RTCC Panel
Gateway Panel
Auxiliary BCU Panel
CRP for Capacitor Bank
DPLCC Panel
RTU Panel
MUX Panel
FO Panel
3KVA Inverter
110 V Charger
110V Battery Bank
48V Charger
48 V Battery Bank
110V DCDB
48 V DCDB
AMF panel
100KVA Changeover Panel
100KVA Genset
Air Conditioner
9U Rack
Marshalling Box
Any other equipment/object not mentioned above but required to be shifted and re commissioned for successful completion of the project
ETC of Isolators including laying and termination of LT power and control cables
245KV, 3150A, 50kA for 3 sec, Horizontal Double Break type Isolator with double earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
145KV, 2000A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch (tandem type) complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with one earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
Hoisting and erection of Insulators, Hardware Fittings & Stringing of Conductors
220kV, 2x120kN double tension string Antifog insulators and hardwares suitable for Single Zebra conductors
220kV, 2x120kN double suspension string Antifog insulators and hardwares suitable for Twin Moose conductors
132kV, 2 x160kN double tension string Antifog insulators and hardwares suitable for Twin MOOSE conductors
132kV, 2 x120kN double suspension string Antifog insulators and hardwares suitable for Twin MOOSE conductors
132kV,120kN single suspension string Antifog insulators and hardwares suitable for Single MOOSE conductors
ACSR Moose Conductor
Clamps, Connectors and Hardware fittings (as per site requirement)
245KV, 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
145 KV, 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
72.5 kV , 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
ETC of Station Service Transformer, PRP (with structure, if applicable) and its accessories as below including laying and termination of LT power and control cables
500 KVA, 33/0.433kV StationTransformer (Energy Efficiency Level 3) , including Clamps & Connectors
250 KVA, 33/0.433kV StationTransformer (Energy Efficiency Level 3) , including Clamps & Connectors
Power receiving panel with 440V MCCB of adequate rating for Station Service Transformer
ETC of Surge Arrestor including laying and termination of LT power and control cables
216kV, 10kA, LA complete with Surge Monitor, hardware fittings, clamp & connectors as per specification
120kV, 10kA, LA complete with Surge Monitor, hardware fittings, clamps & connectors as per specification
60kV, 10kA, LA with surge counter, hardware fittings, clamps & connectors as per specification
30kV, 10kA, LA with surge counter, hardware fittings, clamps & connectors as per specification
ETC of CVT and Wave Trap alongwith structure including laying and termination of LT power and control cables
220kV, 4400pF, 3 Wdg CVT, complete with Junction Box, hardware fittings, clamps & connectors
220KV, 1250A Wave Trap complete with hardware fittings and clamps and connectors.
132kV, 4400pF, 3 Wdg CVT, complete with Junction Box, hardware fittings, clamps & connectors
132KV, 800A Wave Trap complete with all accessories
ETC of Circuit Breaker including laying and termination of LT power and control cables, construction of foundation alongwith supply of all foundation materials and labour
145 kV, 3150 A, SCR 40 kA for 3 sec, SF6 Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure with 10 % spare SF-6 gas.
72.5 kV 3150 A, SCR 40 kA for 3 sec, SF6 Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure with 10 % spare SF-6 gas.
36 kV 1250 A, SCR 31.5 kA for 3 sec, Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure
ETC of Bay Marshalling Kiosk alongwith structure including laying and termination of LT power and control cables, construction of foundation alongwith supply of all foundation materials and labour
220kV Bay Marshalling Kiosk
132 kV Bay Marshalling Kiosk
ETC of Instrument Transformer (CT & PT) alongwith Junction Boxes including laying and termination of LT power and control cables
132KV, 1200-1000/1-1-1-1-1 A Current Transformer
132KV, 600-400/1-1-1-1-1 A Current Transformer
132KV, 1600-1200-800/1-1-1-1-1 A Current Transformer
132 kV Potential Transformer
72.5 kV 50-25/1-1-1-1-1 A Current Transformer
72.5 kV Potential Transformer
ETC of Control, Relay & Protection Panel(Simplex Type)
245kV GIS
Bus Bar Control and Protection Panel
Line Control and Protection Panel
Transformer Control and Protection Panel
Bus Coupler Control and Protection Panel
145kV GIS
Line Control and Protection Panel
Transformer Control and Protection Panel
Bus Coupler Control and Protection Panel
Bus Bar Control and Protection Panel
72.5 kV AIS
Station Service Transformer Control and Protection Panel
Relevant software for relay configuration & setting, maintenance etc.
33 kV AIS
Capacitor Bank Control and Protection Panel
Relay Maintenance Tool Kit as per Clause 14.48 of Volume II
ETC and installation of Complete Substation System Automation System (As per specification ) including laying and termination of LT power and control cables
Bay Control Units for 220kV Bays
Bay Control Units for 132kV Bays
Bay Control Units for 72.5 kV Bays
Station HMI (Main, Redundant and Metering)
Maintenance HMI (DR Workstation)
Gate way with PLCC and Fibre Optic Modem and Panel
5 kVA SAS Inverter
UPS with separate 220 V Battery Bank
Colour Laser Printer
Dot Matrix Printer
Line Printer
GPS Clock System
Bay Ethernet Switch
Station Ethernet Switch
All interphase equipment for Gateway to SLDC
All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
RTU Panel
Aux BCUs as per scheme requirement
SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
27 Inch LCD Monitor (Industrial)
Annual Maintenance Contract (AMC) as per clause 15.30 of Vol II
Erecton, testing and commissioning of following GIS modules and equipments including laying and termination of LT power and control cables etc. as required:
245 kV GIS Equipment
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Line bay module as per technical specification
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Transformer bay module (HV of 160MVA Transformer) as per technical specification
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Bus Coupler bay module as per technical specification
245kV, Three number, 1-phase (isolated units)/3 phase, SF6 gas insulated metal enclosed 50kA for 3 sec, Bus Bar as per technical specifications
245kV extension module (both 3 phase and single phase) complete with all requirements for necessary bus extension
245kV, 3150A, 50 kA for 3 sec, 1- phase SF6 to air bushings along with termination module & support structure for outdoor connections to connect GIS with 245kV side of Power transformer and overhead lines
245kV, 3150A, 50kA for 3 second, 1-Ph, SF6 Gas Insulated Bus Duct (GIB) outside GIS hall including Bus Duct support structure and associated accessories and jointing elements
7.5 Ton EOT Crane (Double Girder) for 245kV GIS Building
Commissioning of Testing And Maintenance Equipment of GIS as per requirement
Online Partial Discharge Monitoring Unit
SF6 gas quality testing unit
SF6 Gas Leak Detector
Precision Pressure Gauge
SF6 Gas Evacuation Plant with Processing, Drying, Storage and Filling Unit (One mobile cart and one static cart)
Video Borescope
SF6 gas Mask
ETC of 160MVA, 220/132/33kV, ONAN/ ONAF/OFAF, ICT along with all accessories as below: (including terminal connectors and other acessories as per technical specification) including laying and termination of LT power and control cables and other signalling cables
160 MVA, 220/132/33 kV, Three phase Auto Transformer with OLTC (including Transformer oil)
Oil & winding temperature monitoring system (FO based)
Online DGA
Online insulating drying system
Digital RTCC Panel
10% Extra OIL for each transformer
Terminal connector on 220kV side bushing of 220/132 kV Transformer to suit Twin Moose conductor
Terminal connector on 132kV side bushing of 220/132kV Transformer to suit Twin Moose conductor
Single phase HV side 3 core bushing phase CT (1000/1A, 2 core) and 1 core for WTI
Single phase IV side 3 core bushing phase CT (1000/1A, 2 core) and 1 core for WTI
Single phase bushing mounted NCT (1000/1A, 3 core)
Rail Track for Transformer
Pulling Block for Transformer
Erection of STRUCTURES along with construction of foundation including supply of all foundation materials and labour
245 kV Isolator with double earth switch
145 kV Isolator with single earth switch
145 kV Isolator without earth switch
145 kV Isolator (tandem type)
72.5 kV Isolator (with earth switch)
72.5 kV Isolator (without earth switch)
245 kV CVT
145 kV CVT
ETC of Battery & Battery Chargers, DCDB & ACDB etc. as per specification including laying and termination of LT power and control cables
220V VRLA Battery, 600AH
220V, Dual Float Cum Boost Chargers, 150A
220V, DCDB
48V VRLA type Battery Bank, 300 AH
48V, 60A Modular SMPS based Dual Float cum Boost Chargers
48V, DCDB
Main ACDB
Sub ACDB
MLDB with 415V/415V, 100kVA isolation transformer
ELDB with 415V/415V, 50kVA isolation transformer
HVAC DB
MCBDB
Auxiliary ACDBs, Sub DCDBs etc as per requirement
110 V DCDB for existing Rowta GSS
415 V ACDB for existing Rowta GSS
ETC of Power Line Carrier Communication Equipments including laying and termination of LT power and control cables
HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 150 km ) for 220kV
Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 150 km ) for 132kV
IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with relay, E1 interface card and optical interface card to support 150 km(220kV)
IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with relay, E1 interface card and optical interface card to support 150 km(132 kV)
EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
LMU and LMDU
Armoured Audio Cable
CAT 6 armoured cable.
Walkie talkie handset to operate seamlessly within a radius of 1km using license free band. (Motorola or better)
Two wire telephone set
ETC of 132 kV XLPE Cable and Termination Kit as per specification
1000 sqmm, 132kV, 1-Core, XLPE Armoured Cu cable alongwith related accessories
132kV Cable Termination Kit along with its accessories and related structure for outdoor type.
Design, Manufacture and supply of Single Core Straight Through Jointing Kit including Cross Bonding with all consumables for 1000 sq mm 132 KV XLPE Armoured Cu underground cable
Supply of three phase link boxes with SVL and 6.6 KV grade XLPE cable suitable for 132 KV XLPE Armoured Cu under ground single core 1000 sq mm XLPE cable for earthing at cable sealing end Terminations and straight through joint with all related accessories as required.
Supply of Single phase link boxes without SVL and 6.6 KV grade XLPE cable suitable for 132 KV XLPE Armoured Cu under ground single core 1000 sq mm XLPE cable for earthing at cable sealing end Terminations and straight through joint with all related accessories as required.
Supply of cable route marker, cable tags, cable phase identification band, jointing marker, clamp connector, trefoil clamp of nylon with neoprene gasket, warning tape, lugs, danger plate, phase plate, circuit marker ,GI Flats, Electrodes ,Earthing Materials, Trefoil Clamps for 132kV Cable etc.
Supply of DTS (Distributed Temperature Sensor) including DTS system for real time thermal monitoring of single core 1000 sqmm underground XLPE cable
Supply of Galvanized steel structures for cable pot-head termination.
Bonding cable of relevant size to suit 132kV 1000sqmm XLPE Cu Cbale as per calculation
Other Cable accessories (perforated and ladder cable trays, insert plates, MS curb angles etc) as per requirement.
Erection of Multi Modular Cable sealing system for all cable entries at 220kV GIS building, Control room, Kiosk building, FFPH building etc. as per requirement.
Installation of complete earthing system
Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
Main Earthing Conductor 40mm dia MS Rod
Earthing Conductor: 40mm dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure Etc)
Earthing Conductor: 75X12mm GI Flat For Equipment and Structure Earthing
Earthing Conductor: 50X10Mm GI(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
Earthing Device & Associated Accessories (50 Mm dia Heavy Duty Gi Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI cover)
Earthing Device & Associated Accessories 40Mm dia Ms Rod 3 Mtrs Long For Non Treated Earth Pit with CI cover)
50x8 mm, 50x6 mm, 25x6mm GI Flat as per site requirement
Soil Resistivity Test And Soil Treatment As And When Required
Separate Earthing For 245 Kv GIS Modules (including multi-point earthing)
Separate Earthing For 245 kV GIS Building (with Cu flat of adequate size for GIS earth mat)
Separate Earthing For Control room building
Separate Earthing For Fencing Around The Substation
Auxiliary/Satellite Earth mat wherever applicable
Other Earthing Accessories ( required for complete earthing of the entire switchyard and the buildings)
Erection of lattice Steel Structures
Galvanised Lattice structures for incoming and outgoing gantries etc
220kV Column
220kV Beam
132kV Column
132kV Beam
Foundation Bolts (Including nuts,checknut & washers for lattice and pipe structures)
Fastners(nuts, bolts and washers) including step bolts for lattice and pipe structures
Design, construction and installation of HVAC & VENTILATION
Industrial Air conditioning system for 220kV GIS Building, Control room building.
2 TON CAPACITY SPLIT AIR CONDITIONING UNITS for Control Room Building ( Battery room , Engineer Room , JE Room, Electrical room, Conference room and SCADA room) Including all CRP/LCP housing room of the GIS Halls, having N+1 or N+2 Standby Requirements for Battery Room, CRP/LCP Housing Room and SCADA Room only.
Ventilation system for 245kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
Design, construction and installation of Fire Alarm & Detection
Fire Alarm & Detection system for 245kV GIS Building and related rooms, Control Room building and other related rooms including Fire Alarm panel, Multi Sensor detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling and ISOLATING MODULE as per specification.
Portable and wheel/trolley mounted Fire Extinguishers for Control Room Building and Switchyard as per specification and Portable Fire Extinguisher for GIS Hall (5kg X 6Nos and 2kg X5 Nos), Officer Quarter (2kg X 6Nos), Staff Quarter (2kg X 6Nos), Security Barrack (2kg X 6Nos),Guard room (Security Booth) (2kg X 3Nos), Store Building (2kg x5) as per specification.
Trolley mounted portable fire exinguishers (Dry powder chemical type) for 500 kVA transformers ( 10 Kg , DCP Type)
Design, construction and installation of Hydrant & HVWS (High Velocity Water Spray) system/NIFPES
Hydrant system along with pumping arrangement & associated Civil works for fire protection system for 2 No of Transformer
HVWS system for 160 MVA Auto Transformer-2 No’s
NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 2 Nos ICT
ETC of 250 KVA, silent type DG Set with AMF including Panel & Accessories and including earthing arrangement including laying and termination of LT power and control cables alongwith construction of foundation and supply of all foundation materials and labour
ETC and installation of Lighting System
Indoor Lighting
Lighting System including Lighting panel, Distribution Boards, Cabling, Conduiting, Switches, Socket, Junction boxes, auxiliary receptacle, High bay fixtures for GIS rooms
245 kV GIS Building
Control Room Building
FFPH Building
Pump House
Security booth
Security barrack
Staff Quarter, Officer Quarter, store building & open store shed
Outoor Lighting
Outdoor LED lighting for Switchyard, Road area, Car parking, Security outpost including Lighting panel, Distribution Boards, Cabling, Switches, Socket, auxiliary receptacle, complete with GI Poles etc.
Installation of Public Addressing System, CCTV including laying of cables in both new and existing switchyrads with 75''VDU
Erection and installation of Lightning protection (lightning masts 50 metres high, Lightning Spike, shield wire97/4 mm GI shield wire), down conductors etc.) including earthing arrangement along with construction of foundation and supply of all foundation materials and labour.
Erection of Miscellaneous item(like MS Channel,Angle, Rail, Chequered plate,MS Grill plate, Lugs and Glands, Switchyard and Bay Identification Name board, Anchor fastner and Display for Overall single line diagram photo with frame.etc…as per site requirement)
Plant Tests and Inspection Travel Cost for Employer and Project Manager
Air Travel Fares to Contractor's,Manufacturer's or Test Labs per person trip
Per Diems Covering Accomodation (Minimum 4 star Hotel), Meals and Minor Out of Pocket Expenses, per Test and Inspection Program Days
Training, Orientation and Documentation including Support Services as per the relevant clauses of the BID
Description of Work / Item(s)
Amount
SUPPLY of Following type tested Lattice type Galvanized steel suspension / Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, tower super structure complete including step bolts. Supply of black bituminous paint for three coats up to a height of 500mm above the cooping (legs & bracing members). All Supply should confirm to the Technical Specification. 220kV Towers and 220kV Multi circuit towers shall be designed to suit Twin AAAC Zebra conductor; 400kV Towers shall be designed to suit Twin ACSR Moose conductor (along with 96F OPGW)
Multi circuit Tower D+3(LT4+3)
Multi circuit Tower D+6 (LT4+6)
Multi circuit Tower D+9 (LT4+9)
Multi circuit Tower D+15 (LT4+15)
SUPPLY of Following type tested Lattice type special structures (Gantry type) with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, strain plates complete including step bolts. All Supply should confirm to the Technical Specification.
Crossing Gantry
Adjustable Stub setting template
A type
B type
C type
D type
400kV D type
Multi circuit tower D type
Galvanized iron nuts & bolts for above template
A type
B type
C type
D type
400kV D type
Multi circuit tower D type
Procurement of Danger plates.
Procurement of Phase plates.(Set of Three)
Procurement of Number plates.
Procurement of Bird guard. (Set of Three)
Procurement of anti climbing device
Procurement of Circuit Plate
37/4.00 mm All Aluminium Alloy Conductor Zebra
POWER CONDUCTOR ACCESSORIES
Stock bridge type Vibration Damper
Preformed Armoured Rods
Mid Span Compression Joint for Conductor
Repair Sleeve for Conductor
Bird Divereter as per CEA Guidelines
FIBRE OPTIC CABLES AND HARDWARE FITTINGS & Fibre Optic Cables
96 Fibre (DWSM) OPGW fibre optic cable
96 Fibre Optic Approach Cable (DWSM96F)
OPGW HARDWARE/FITTINGS AND TERMINATIONS
OPGW Suspension Assembly
OPGW double tension pass through assembly
OPGW Splicing Tension Assembly in Suspension tower
OPGW Double Tension Assembly for splicing location c/w pre-formed armour rods and tower bond clamps
OPGW Tension Single Dead-end Set for termination/ run-in c/w pre-formed armour rods and tower bond clamps
OPGW Vibration Damper c/w pre-formed armour rods
Down Lead Clamp
OPGW optical Splice/Joint Kit (192 fibre) including junction box (min 4 mm thick)
Loop Bracket
FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
Others (For any additional Hardware and Fittings, tenderer to specify)
Supply of following Aviation Requirements
Span Markers
Obstruction Lights (to be provided as per IS 5613)
2 Medium Intensity + 2 Low Intensity
PORCELAIN LONG ROD INSULATOR
Porcelain Long rod insulator for 220 KV TL-90 KN (Suspension insulator)
Porcelain Long rod insulator for 220 KV TL-120 KN (Tension insulator)
HARDWARE FITTINGS
Hardware fittings for 220kV AC with AAAC ‘Zebra Conductor-Single "I" Suspension String
Hardware fittings for 220kV AC with AAAC ‘Zebra Conductor-Single "I" Suspension String (Pilot)
Hardware fittings for 220kV AC with AAAC ‘ZEBRA Conductor-Double Tension String 120X2 kN
Hardware fittings for 220kV AC with AAAC ‘Zebra Conductor-Single Tension
Tower earthing accessories
40 mm dia, 3 mtr long GI pipe electrode (driven) with test link
50x6 mm GI flat as required
Other earthing accessories like GI steel wires, lugs, etc
Design Services
Design services as per bid for the above towers suitable for twin AAAC Zebra and Twin ACSR Moose along with 96F OPGW (Design and type test)
GI Shield wire for twin peak towers including shield wire clamps, clamps for adjacent single peak towers to twin peak towers
Description of Work / Item(s)
Amount
Erection of following type tested lattice type galvanised steel suspension/Angle tower with stubs and cleats, different type of GI HT Nuts & Bolts, washers for the towers, hangers and all accessories, tower superstructure complete including step bolts
Multi circuit Tower D+3
Multi circuit Tower D+6
Multi circuit Tower D+9
Multi circuit Tower D+15
Crossing gantry (special type)
Stringing of power conductors including transportation from Stores and distribution of conductors and accessories to sites and laying, stringing, tensioning , clamping, jointing, jumpering and hoisting of insulators complete including cost of all fittings and accessories not specifically mentioned elsewhere per route Km (6 conductors for Double Circuit Line) of line.
Grounding of towers with 3 metre long 40 mm dia G I pipe along with 50x6 GI flat, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, coke etc as per Specification.
Painting of towers with bituminous paints of approved quality up to 5 metres from ground level including the cost of paints.
Erection of Danger plates. (1 no per tower)
Erection of Phase plates. (6 nos per tower as required)
Erection of Number plates. (1 no per tower)
Erection of Bird guard. (6 nos per tower as required)
Erection of anti climbing device (1 set per tower)
Erection of Circuit Plate
Check Survey as per Specification
Welding of all nuts & bolts up to the bottom cross arm level including all charges of transportation, materials etc.
Multi circuit Tower D+3(LT4+3)
Multi circuit Tower D+6 (LT4+6)
Multi circuit Tower D+9 (LT4+9)
Multi circuit Tower D+15 (LT4+15)
Crossing gantry (special type)
Concreting of foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel.
13.1. For A Type Tower
(i) Wet Type foundation
(ii) Partially submerged Type
(iii) Fully submerged Type
13.2. For A+3 Type Tower
(i) Wet Type foundation
13.3. For A+6 Type Tower
(i) Wet Type foundation
13.4. For A+9 Type Tower
(i) Wet Type foundation
13.5. For B+0 Type Tower
(i) Wet Type Foundation
13.6. For B+3 Type Tower
(i) Wet Type foundation
(ii) Partially Submerged Type
13.7. For B+6 Type Tower
(i) Wet Type foundation
(ii) Partially Submerged Type
(iii) Pile Type
13.8. For B+9 Type Tower
(i) Wet Type foundation
13.9. For C Type Tower
(ii) Wet Type foundation
(ii) Partially Submerged Type
13.10. For C+3 Type Tower
(i) Wet Type foundation
(ii) Partially Submerged Type
13.11. For C+6 Type Tower
(i) Wet Type foundation
13.12. For C+9 Type Tower
(i) Wet Type Foundation
13.13. For D Type Tower
(i) Wet Type foundation
(ii) Partially Submerged Type
13.14. For D+3 Type Tower
(ii) Wet Type foundation
(ii) Partially Submerged Type
13.15. For D+6 Type Tower
(i) Wet Type foundation
(ii) Partially Submerged Type
(iii) Pile Type
13.16. For D+9 Type Tower
(i) Wet Type foundation
(ii) Partially Submerged Type
(iii) PileType
13.17. For D+12 Type Tower
(i) Partially Submerged Type
(ii) Pile Type
13.17. For 400kV D+9 Type Tower
(i) Partially Submerged Type
(ii) Wet Type foundation
13.17. For 400kV D+12 Type Tower
(i) PileType
13.17. For 400kV D+18 Type Tower
(i) PileType
13.17. For 400kV D+25 Type Tower
(i) PileType
13.17. For Multi circuit tower D+3 Type Tower
(i) Partially Submerged Type
13.17. For Multi circuit tower D+6 Type Tower
(i) Wet Type foundation
13.17. For Multi circuit tower D+9 Type Tower
(i) Wet Type foundation
13.17. For Multi circuit tower D+15 Type Tower
(i) Wet Type foundation
13.17. For Gantry Type Structure
(i) Wet Type foundation
OPGW cable & characteristic
Stringing of 96 Fibre (DWSM)OPGW Fibre Optic cable including transportation and distribution of OPGW and accessories to site and laying, stringing, tensioning , clamping, jointing , complete including all fittings and accessories not specifically mentioned elsewhere per route Km of line
Installation of Hardware set for above 96 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories like suspension assembly, tension assembly, dead end tension assembly at line terminations, tension double end set for splice location, vibration dampers, earthing clamps, down lead clamps, in-line spice enclosures etc.
Joint box (96 Fibre) (min 4 mm thick)
Installation of FODP
FODP 96F : Indoor Type, rack mounted with FCPC coupling and pig tails
Fibre Optic approach cable (DWSM 96F)
Installation of 96 Fibre (DWSM) Fibre Optic approach cable
Installation of hardware set for above 96 Fibre, Fibre Optic Approach Cable ties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
Installation of Span Markers
Installation of Obstruction Lights (to be provided as per IS 5613)
(i) 2 Medium Intensity + 2 Low Intensity
Protection of tower footing
supply and installation of ' Random rubble stone masonary including excavation (1:5 cement mortar)
supply and installation of Backfilling and gap levelling of volumes enclosed by revetment
supply and installation of M 15 (1:2:4) mixed concrete for top seal cover of revetment
supply and installation of Stone Bound in Galvanising wire netting including excavation
Benching: All kinds of soils including fissured rock,hard rock and sandy soil
GI Shield wire for twin peak towers including shield wire clamps, clamps for adjacent single peak towers to twin peak towers
Obstruction Lights (to be provided as per IS 5613)
2 Medium Intensity + 2 Low Intensity
PORCELAIN LONG ROD INSULATOR (for LILO Portion)
Porcelain Long rod Antifog insulator for 220 KV TL-90 KN
Porcelain Long rod Antifog insulator for 220 KV TL-120 KN
HARDWARE FITTINGS (for LILO portion)
Hardware fittings for 220kV AC with AAAC Zebra Conductor-Single "I" Suspension String (Pilot)
Hardware fittings for 220kV AC with AAAC Zebra Conductor-Double Tension String 120X2 kN
Hardware fittings for 220kV AC with AAAC Zebra Conductor-Single Tension
Others (For any additional Hardware and Fittings, tenderer to specify)
Supply of following Aviation Requirements
Span Markers
Obstruction Lights (to be provided as per IS 5613)
2 Medium Intensity + 2 Low Intensity
PORCELAIN LONG ROD INSULATOR
Porcelain Long rod Antifog insulator for 400 KV TL-120 KN
Porcelain Long rod Antifog insulator Suitable for twin ACSR Moose (400 KV TL)-160 KN
HARDWARE FITTINGS
Hardware fittings for 400kV AC with twin ACSR Moose Conductor-Double "I" Suspension String 120 x 2 kN
Hardware fittings for 400kV AC with twin ACSR Moose Conductor-Single "I" Suspension String (Pilot) 120kN
Hardware fittings suitable for twin ACSR Moose Conductor-Double Tension String 160 x 2 kN
Design services
Design of the above 400kV hilly terrain towers along with foundation design (for wet type, dry type, semi submerged type and fully sub merged type) as per IS-802-2015 suitable for twin ACSR moose and twin 96F OPGW.
Description of Work / Item(s)
Amount
CIVIL WORK (As per technical specification)
Soil Investigation
Standards, Design And Drawings
Site Clearance including necessary excavation
Site Preparation : Earthfilling and compaction
Dismantling of existing Fencing
Dismantling of existing Control Room Building
Dismantling of existing Boundary Wall
Construction of Boundary Wall with retaining wall
Construction of retaining wall
Construction of Boundary Wall
Buildings (including All services i.e. electrical, indoor lighting, internal water supply and sanitary works complete)
220 KV GIS Building alongwith GIS bay foundations complete
G+2 Control Room building
G+2 Officers Quarter cum RE residence
G+2 Staff Quarter cum Security Barrack
Store Building
Security booth
Open store shed
Water supply system
Supply and installation of Deep tubewell, with appropriate depth required to reach aquifer with PVC casing pipe (200 mm diameter minimum), 3 HP submersible mortor pump, 40 mm diameter CPVC column pipe, one unit RCC (M-25 grade) Slow Sand Filter (Capacity 10,000 Ltr/hr) along with RCC (M-25 grade) reservoir 600 mm above FGL (Capacity 35,000 Ltr) Supply and Installation of distribution network with CPVC pipe of 40 mm diameter and 25 mm diameter for connecting to Overhead tank of all buildings.
HVWS with Water reserviour and Pumphouse
Supply and installation of Deep tubewell, with appropriate depth required to reach aquifer with PVC casing pipe (200 mm diameter minimum), 3 HP submersible mortor pump, 40 mm diameter CPVC column pipe and construction of Overground Water reservior and RCC Pump house for fire fighting. (Design and Drawing to be prepared by Contractor and shall be approved by AEGCL)
Dismantling of existing temple and construction of new temple
Parking Shed (1 unit of 5.5 x 3 m)
Construction of Transformer pad for 220/132kV, 160MVA Transformer with oil pit (suitable for 200 MVA)including supply of all foundation materials and labour
Construction of 500KVA, 33/0.4KV Station Transformer pad including supply of all foundation materials and labour
Construction of burnt oil pit connecting 2 tranformer foundations and including supply of all foundation materials and labour
Construction of DG set foundation including supply of all foundation materials and labour
Fire Protection Wall including supply of all foundation materials and labour
Construction of cable trench as per technical specification including supply of all foundation materials and labour
Type-A
Type-B
Type-C
Design and contruction of Cable trench for 132 kV XLPE cable from existing 132 kV switchyard to proposed 132 kV switchyard
Design and contruction of Cable trench for 220kV GIS building
Design and contruction of Cable trench for new Control room building
Type-D
Drain
Sewage Drain
Storm Water Drain
Sump Pit with 2 HP electric motor pump set
Antiweed treatment
PCC in Switchyard
Stone Spreading(Gravelling) in switchyard
Security Fencing
Main gate
Switchyard Gate
Roads (Inter locking Concrete Block Pavement (ICBP) Block Road)
RCC Box Culvert
Landscaping, Garden & Plantation
Rain Water Harvesting
Furniture
220 KV GIS Building alongwith GIS bay foundations complete
G+2 Control Room building
G+2 Officers Quarter cum RE residence
G+2 Staff Quarter cum Security Barrack
Store Building
Security booth
Control Room Building
Executive Table (1800mmX900mm) (Wooden)
Executive Chair (Revolving Mid Back Type)
Visitor's Chair with Hand Rest
Computer Room Executive Chair (Revolving Mid Back Type)
Steel Almirah (1016mmX560mmX1980mm)
1 No of Recta work Station of Size 1200mmX600mm, 25mm thick worktop with 3 drawer Pedestal along with keyboard tray and CPU Trolley and partition of thickness 53mm and of height 1200mm
Conference Room Table
Furniture for HMI and Metering PC
ESMP Requirement
Personal protective equipment’s (Hard hats (with full/partial brims as necessary) Safety glasses with side shields. Face masks/shields. Suitable footwear (safety/steel-toed boots, rated dielectric footwear) Insulating gloves (rated, used along with leather/cloth linings for shock protection)) as per site requirement
Wire insulation/ Bird Deflectors/ Bird Flapper as per requirement including installation
Description of Work / Item(s)
Amount
Isolators
245KV, 3150A, 50kA for 3 sec, Horizontal Double Break type Isolator with double earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
145KV, 2000A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator with single earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators,Clamps & Connectors
145KV, 1600A, 40kA for 3 sec, Horizontal Double Break type Isolator without earth switch (tandem type) complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors
72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with one earth switch complete with manual and motor driven operating mechanisms along with Support Insulators,Clamps & Connectors and Hardware Fittings
72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
33 kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch complete with manual and motor driven operating mechanisms along with Support Insulators, Clamps & Connectors and Hardware Fittings
Insulators, hardware & Conductors
220kV, 2x120kN double tension string Antifog insulators and hardwares suitable for Single Zebra conductors
220kV, 2x120kN double suspension string Antifog insulators and hardwares suitable for Twin Moose conductors
132kV, 2 x160kN double tension string Antifog insulators and hardwares suitable for Twin MOOSE conductors
132kV, 2 x120kN double suspension string Antifog insulators and hardwares suitable for Twin MOOSE conductors
132kV,120kN single suspension string Antifog insulators and hardwares suitable for Single MOOSE conductors
ACSR Moose Conductor
Clamps, Connectors and Hardware fittings (as per site requirement)
245KV, 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
145 KV, 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
72.5 kV , 1 phase Solid core bus post insulator (creepage distance 31mm/kV)
Station Service Transformer
500 KVA, 33/0.433kV StationTransformer (Energy Efficiency Level 3) , including Clamps & Connectors
250 KVA, 33/0.433kV StationTransformer (Energy Efficiency Level 3) , including Clamps & Connectors
Power receiving panel with 440V MCCB of adequate rating for Station Service Transformer
Surge Arrester
216kV, 10kA, LA complete with Surge Monitor, hardware fittings, clamp & connectors as per specification
120kV, 10kA, LA complete with Surge Monitor, hardware fittings, clamps & connectors as per specification
60kV, 10kA, LA with surge counter, hardware fittings, clamps & connectors as per specification
30kV, 10kA, LA with surge counter, hardware fittings, clamps & connectors as per specification
CVT and Wave Trap
220kV, 4400pF, 3 Wdg CVT, complete with Junction Box, hardware fittings, clamps & connectors
220KV, 1250A Wave Trap complete with hardware fittings and clamps and connectors.
132kV, 4400pF, 3 Wdg CVT, complete with Junction Box, hardware fittings, clamps & connectors
132KV, 800A Wave Trap complete with all accessories
Circuit Breaker
145 kV, 3150 A, SCR 40 kA for 3 sec, SF6 Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure with 10 % spare SF-6 gas.
72.5 kV 3150 A, SCR 40 kA for 3 sec, SF6 Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure with 10 % spare SF-6 gas.
36 kV 1250 A, SCR 31.5 kA for 3 sec, Circuit Breaker, outdoor type, 3-Ph gang operated complete with operating mechanism & support structure
Bay Marshalling Kiosk along with support structures
220kV Bay Marshalling Kiosk
132 kV Bay Marshalling Kiosk
Instrument Transformers along with junction box and all other accessories
132KV, 1200-1000/1-1-1-1-1 A Current Transformer
132KV, 600-400/1-1-1-1-1 A Current Transformer
132KV, 1600-1200-800/1-1-1-1-1 A Current Transformer
132 kV Potential Transformer
72.5 kV 50-25/1-1-1-1-1 A Current Transformer
72.5 kV Potential Transformer
Control, Relay & Protection Panel(Simplex Type)
245kV GIS
Bus Bar Control and Protection Panel
Line Control and Protection Panel
Transformer Control and Protection Panel
Bus Coupler Control and Protection Panel
145kV AIS
Line Control and Protection Panel
Transformer Control and Protection Panel
Bus Coupler Control and Protection Panel
Bus Bar Control and Protection Panel
72.5 kV AIS
Station Service Transformer Control and Protection Panel
Relevant software for relay configuration & setting, maintenance etc.
Relay Maintenance Tool Kit as per Clause 14.48 of Volume II
33 kV AIS
Capacitor Bank Control and Protection Panel
Complete Substation System Automation System (As per specification )
Bay Control Units for 220kV Bays
Bay Control Units for 132kV Bays
Bay Control Units for 72.5 kV Bays
Station HMI (Main, Redundant and Metering)
Maintenance HMI (DR Workstation)
Gate way with PLCC and Fibre Optic Modem and Panel
5 kVA SAS Inverter
UPS with separate 220 V Battery Bank
Colour Laser Printer
Dot Matrix Printer
Line Printer
GPS Clock System
Bay Ethernet Switch
Station Ethernet Switch
All interphase equipment for Gateway to SLDC
All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
RTU Panel
Aux BCUs as per scheme requirement
SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
27 Inch LCD Monitor (Industrial)
Annual Maintenance Contract (AMC) as per clause 15.30 of Vol II
Supply of 245 kV GIS
245 kV GIS Equipment
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Line bay module as per technical specification
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Transformer bay module (HV of 160MVA Transformer) as per technical specification
245kV, 50kA for 3 second, SF6 gas-insulated metal enclosed Bus Coupler bay module as per technical specification
245kV, Three number, 1-phase (isolated units)/3 phase unit, SF6 gas insulated metal enclosed 50kA for 3 sec, Bus Bar module as per technical specifications
245kV extension module (Both 3 phase and single phase) complete with all requirements for necessary bus extension
245kV, 3150A, 50 kA for 3 sec, 1- phase SF6 to air bushings along with termination module & support structure for outdoor connections to connect GIS with 245kV side of Power transformer and overhead lines
245kV, 3150A, 50kA for 3 second, 1-Ph, SF6 Gas Insulated Bus Duct (GIB) outside GIS hall including Bus Duct support structure and associated accessories and jointing elements
7.5 Ton EOT Crane (Double Girder) for 245kV GIS Building
Supply, Testing And Maintenance Equipment of GIS as specified
Online Partial Discharge Monitoring Unit
SF6 gas quality testing unit
SF6 Gas Leak Detector
Precision Pressure Gauge
SF6 Gas Evacuation Plant with Processing, Drying, Storage and Filling Unit (One mobile cart and one static cart)
Video Borescope
SF6 gas Mask
160MVA, 220/132/33kV, ONAN/ ONAF/OFAF/ODAF, 3 Phase Auto Transformer along with all accessories as below:
160 MVA, 220/132/33 kV, Three phase Auto Transformer with OLTC (including Transformer oil)
Oil & winding temperature monitoring system (FO based)
Online DGA
Online insulating drying system
Digital RTCC Panel
10% Extra OIL for each transformer
Terminal connector on 220kV side bushing of 220/132 kV Transformer to suit Twin Moose conductor
Terminal connector on 132kV side bushing of 220/132kV Transformer to suit Twin Moose conductor
Single phase HV side 3 core bushing phase CT (1000/1A, 2 core) and 1 core for WTI
Single phase IV side 3 core bushing phase CT (1000/1A, 2 core) and 1 core for WTI
Single phase bushing mounted NCT (1000/1A, 3 core)
Rail Track for Transformer
Pulling Block for Transformer
Mounting Structures (Lattice/pipe)
245 kV Isolator with double earth switch
145 kV Isolator with single earth switch
145 kV Isolator without earth switch
145 kV Isolator (tandem type)
72.5 kV Isolator (with earth switch)
72.5 kV Isolator (without earth switch)
245 kV CVT
145 kV CVT
Battery & Battery Chargers, DCDB & ACDB as per specification
220V VRLA Battery, 600AH
220V, Dual Float Cum Boost Chargers, 150A
220V, DCDB
48V VRLA type Battery Bank, 300 AH
48V, 60A Modular SMPS based Dual Float cum Boost Chargers
48V, DCDB
Main ACDB
Sub ACDB
MLDB with 415V/415V, 100kVA isolation transformer
ELDB with 415V/415V, 50kVA isolation transformer
HVAC DB
MCBDB
Auxiliary ACDBs, Sub DCDBs etc as per requirement
110 V DCDB for existing Rowta GSS
415 V ACDB for existing Rowta GSS
Power Line Carrier Communication Equipments (Twin Channel, 8kHz)
HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 150 km ) for 220kV
Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 150 km ) for 132kV
IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with relay, E1 interface card and optical interface card to support 150 km(220kV)
IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with relay, E1 interface card and optical interface card to support 150 km(132 kV)
EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
LMU and LMDU
Armoured Audio Cable
CAT 6 armoured cable.
Walkie talkie handset to operate seamlessly within a radius of 1km using license free band. (Motorola or better)
Two wire telephone set
132 kV XLPE Cable and Termination Kit as per specification
1000 sqmm, 132kV, 1-Core, XLPE Armoured Cu cable alongwith related accessories
132kV Cable Termination Kit along with its accessories and related structure for outdoor type.
Design, Manufacture and supply of Single Core Straight Through Jointing Kit including Cross Bonding with all consumables for 1000 sq mm 132 KV XLPE Armoured Cu underground cable
Supply of three phase link boxes with SVL and 6.6 KV grade XLPE cable suitable for 132 KV XLPE Armoured Cu under ground single core 1000 sq mm XLPE cable for earthing at cable sealing end Terminations and straight through joint with all related accessories as required.
Supply of Single phase link boxes without SVL and 6.6 KV grade XLPE cable suitable for 132 KV XLPE Armoured Cu under ground single core 1000 sq mm XLPE cable for earthing at cable sealing end Terminations and straight through joint with all related accessories as required.
Supply of cable route marker, cable tags, cable phase identification band, jointing marker, clamp connector, trefoil clamp of nylon with neoprene gasket, warning tape, lugs, danger plate, phase plate, circuit marker ,GI Flats, Electrodes ,Earthing Materials, Trefoil Clamps for 132kV Cable etc.
Supply of DTS (Distributed Temperature Sensor) including DTS system for real time thermal monitoring of single core 1000 sqmm underground XLPE cable
Supply of Galvanized steel structures for cable pot-head termination.
Other Cable accessories (perforated and ladder type cable trays, insert plates, MS curb angles etc) as per requirement.
Bonding cable of relevant size to suit 132kV 1000sqmm XLPE Cu Cbale as per calculation
XLPE Armoured Cu, LT Power Cable (1.1kV grade)
2C, 6sqmm
4C, 16sqmm
3.5C, 35sqmm
3.5C, 70sqmm
3.5C, 400sqmm
Other Cables as per technical specification not covered above
Cable supports and other cable accessories
Others ( Cable for Fire Fighting, Illumination, CCTV etc)
PVC Armoured Cu LT Control Cable (1.1 kV grade)
2C, 2.5sqmm
4C, 2.5sqmm
7C, 2.5sqmm
12C, 2.5sqmm
17C, 2.5sqmm
19C, 2.5sqmm
Other Cables as per technical specification not covered above
Cable supports and other cable accessories
Others ( Cable for Fire Fighting, Illumination, CCTV etc)
Multi Modular Cable sealing system for all cable entries at 220kV GIS building, Control room, Kiosk building, FFPH building etc. as per requirement.
Earthing
Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
Main Earthing Conductor 40mm dia MS Rod
Earthing Conductor: 40mm dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure Etc)
Earthing Conductor: 75X12mm GI Flat For Equipment and Structure Earthing
Earthing Conductor: 50X10Mm GI(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
Earthing Device & Associated Accessories (50 Mm dia Heavy Duty Gi Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI cover)
Earthing Device & Associated Accessories 40Mm dia Ms Rod 3 Mtrs Long For Non Treated Earth Pit with CI cover)
50x8 mm, 50x6 mm, 25x6mm GI Flat as per site requirement
Soil Resistivity Test And Soil Treatment As And When Required
Separate Earthing For 245 Kv GIS Modules (including multi-point earthing)
Separate Earthing For 245 kV GIS Building (with Cu flat of adequate size for GIS earth mat)
Separate Earthing For Control room building
Separate Earthing For Fencing Around The Substation
Auxiliary/Satellite Earth mat wherever applicable
Other Earthing Accessories ( required for complete earthing of the entire switchyard and the buildings)
Supply of Galvanised Lattice structures
220kV Column
220kV Beam
132kV Column
132kV Beam
Foundation Bolts (Including nuts,checknut & washers for lattice and pipe structures)
Fastners(nuts, bolts and washers) including step bolts for lattice and pipe structures
HVAC & VENTILATION
Industrial Air conditioning system for 220kV GIS Building, Control room building.
2 TON CAPACITY SPLIT AIR CONDITIONING UNITS for Control Room Building ( Battery room , Engineer Room , JE Room, Electrical room, Conference room and SCADA room) Including all CRP/LCP housing room of the GIS Halls, having N+1 or N+2 Standby Requirements for Battery Room, CRP/LCP Housing Room and SCADA Room only.
Ventilation system for 245kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
Fire Alarm & Detection
Fire Alarm & Detection system for 245kV GIS Building and related rooms, Control Room building and other related rooms including Fire Alarm panel, Multi Sensor detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling and ISOLATING MODULE as per specification.
Portable and wheel/trolley mounted Fire Extinguishers for Control Room Building and Switchyard as per specification and Portable Fire Extinguisher for GIS Hall (5kg X 6Nos and 2kg X5 Nos), Officer Quarter (2kg X 6Nos), Staff Quarter (2kg X 6Nos), Security Barrack (2kg X 6Nos),Guard room (Security Booth) (2kg X 3Nos), Store Building (2kg x5) as per specification.
Trolley mounted portable fire exinguishers (Dry powder chemical type) for 500 kVA transformers ( 10 Kg , DCP Type)
Hydrant & HVWS (High Velocity Water Spray) system/NIFPES
Hydrant system along with pumping arrangement & associated Civil works for fire protection system for 2 No of Transformer
HVWS system for 160 MVA Auto Transformer-2 No’s
NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 2 Nos ICT
250 KVA, Silent DG Set with AMF including Panel & Accessories including earthing arrangement
Lighting System
Indoor Lighting
Lighting System including Lighting panel, distribution boards, Cabling, Conduiting, Switches, Socket, Junction boxes, auxiliary receptacle, High bay fixtures for GIS rooms
245 kV GIS Building
Control Room Building
FFPH Building
Pump House
Security booth
Security barrack
Staff Quarter, Officer Quarter, store building & open store shed
Outoor Lighting
Outdoor LED lighting for Switchyard, Road area, Car parking, Security outpost including Lighting panel, Distribution Boards, Cabling, Switches, Socket, auxiliary receptacle, complete with GI Poles etc.
Public Addressing System, CCTV in both new and existing switchyards with 75'' VDU
Lightning protection (lightning masts 50 metres high, Lightning Spike, shield wires (7/4 mm GI shield wire), down conductors etc.)
Miscellaneous item(like MS Channel,Angle, Rail, Chequered plate,MS Grill plate, Lugs and Glands,HDPE Pipes Switchyard and Bay Identification Name board, Anchor fastner and Display for Overall single line diagram photo with frame.etc…as per site requirement)
Training
Trainiing as per different Clauses of Volume II of BID Document
Additional items required for completion of the project
Tenderer(s) to specify
Description of Work / Item(s)
Amount
SUPPLY of Following type tested Lattice type Galvanized steel suspension / Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, tower super structure complete including step bolts. Supply of black bituminous paint for three coats up to a height of 500mm above the cooping (legs & bracing members). All Supply should confirm to the Technical Specification. 220kV Towers and 220kV Multi circuit towers shall be designed to suit Twin AAAC Zebra conductor; 400kV Towers shall be designed to suit Twin ACSR Moose conductor (along with 96F OPGW)
Multi circuit Tower D+3(LT4+3)
Multi circuit Tower D+6 (LT4+6)
Multi circuit Tower D+9 (LT4+9)
Multi circuit Tower D+15 (LT4+15)
SUPPLY of Following type tested Lattice type special structures (Gantry type) with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, strain plates complete including step bolts. All Supply should confirm to the Technical Specification.
Crossing Gantry
Adjustable Stub setting template
A type
B type
C type
D type
400kV D type
Multi circuit tower D type
Galvanized iron nuts & bolts for above template
A type
B type
C type
D type
400kV D type
Multi circuit tower D type
Procurement of Danger plates.
Procurement of Phase plates.(Set of Three)
Procurement of Number plates.
Procurement of Bird guard. (Set of Three)
Procurement of anti climbing device
Procurement of Circuit Plate
37/4.00 mm All Aluminium Alloy Conductor Zebra
POWER CONDUCTOR ACCESSORIES
Stock bridge type Vibration Damper
Preformed Armoured Rods
Mid Span Compression Joint for Conductor
Repair Sleeve for Conductor
Bird Divereter as per CEA Guidelines
FIBRE OPTIC CABLES AND HARDWARE FITTINGS & Fibre Optic Cables
96 Fibre (DWSM) OPGW fibre optic cable
96 Fibre Optic Approach Cable (DWSM96F)
OPGW HARDWARE/FITTINGS AND TERMINATIONS
OPGW Suspension Assembly
OPGW double tension pass through assembly
OPGW Splicing Tension Assembly in Suspension tower
OPGW Double Tension Assembly for splicing location c/w pre-formed armour rods and tower bond clamps
OPGW Tension Single Dead-end Set for termination/ run-in c/w pre-formed armour rods and tower bond clamps
OPGW Vibration Damper c/w pre-formed armour rods
Down Lead Clamp
OPGW optical Splice/Joint Kit (192 fibre) including junction box (min 4 mm thick)
Loop Bracket
FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
Others (For any additional Hardware and Fittings, tenderer to specify)
Supply of following Aviation Requirements
Span Markers
Obstruction Lights (to be provided as per IS 5613)
2 Medium Intensity + 2 Low Intensity
PORCELAIN LONG ROD INSULATOR
Porcelain Long rod insulator for 220 KV TL-90 KN (Suspension insulator)
Porcelain Long rod insulator for 220 KV TL-120 KN (Tension insulator)
HARDWARE FITTINGS
Hardware fittings for 220kV AC with AAAC ‘Zebra Conductor-Single "I" Suspension String
Hardware fittings for 220kV AC with AAAC ‘Zebra Conductor-Single "I" Suspension String (Pilot)
Hardware fittings for 220kV AC with AAAC ‘ZEBRA Conductor-Double Tension String 120X2 kN
Hardware fittings for 220kV AC with AAAC ‘Zebra Conductor-Single Tension
Tower earthing accessories
40 mm dia, 3 mtr long GI pipe electrode (driven) with test link
50x6 mm GI flat as required
Other earthing accessories like GI steel wires, lugs, etc
Design Services
Design services as per bid for the above towers suitable for twin AAAC Zebra and Twin ACSR Moose along with 96F OPGW (Design and type test)
GI Shield wire for twin peak towers including shield wire clamps, clamps for adjacent single peak towers to twin peak towers
Description of Work / Item(s)
Amount
Mandatory spares
For 245KV GIS
Complete GIS modules, along with enclosure, all active parts such as conductor, conductor joints, shields, end covers etc. for each type of a)Bus Bar Sections (including Bus Bar Interconnection Modules) b)Bus Ducts Sections (including Compensators/expansion joints/bellows) c)Bends d)SF6/Air Bushing. e)Oil/SF6 Bushing f)Cable Termination kit
245KV Gas Insulated Single phase voltage transformer with enclosure
245KV Gas Insulated Single phase Current transformer with enclosure (1 of each rating)
SF6 gas Pressure relief devices 1 no each type for 245KV GIS
SF6 Pressure gauges cum switch or Density Monitors and pressure switches for 245KV GIS : 1 no. of each type
Coupling device for pressure gauge cum switch for connecting gas handling plant
Rubber gaskets, 'O'-ring and seals for SF6 gas of each type
Trip coil assembly with resistor for 245KV GIS Circuit breaker (2 nos. of each type)
Closing coil assembly with resistor for 245KV GIS Circuit breaker (2 nos. of each type)
Molecular filter for SF6 gas modules with filter bags, 20% of total weight
Molecular filter for SF6 circuit breaker with filter bags, 10% of total weight
All types of control valves for SF6 gas of each type for 245KV GIS
Locking device to keep the Disconnectors and Earthing switches in close or Open position in case of removal of driving mechanism for 245KV GIS.
SF6 to Air bushing as applicable for 245KV GIS
Complete circuit breaker poles of each type and rating complete with interrupter, main circuit, enclosures and marshalling box with operating mechanism ( 1 no. of each type and rating)
Set of spares for local control cabinet including M.C.B., fuses, time relays,all type of auxiliary relay & contactors,lamps,semaphor,terminals, push buttons etc for 245KV GIS
SF6 Pressure gauges cum switch or Density Monitors and pressure switches for SF6 Circuit breaker : 1 no. of each type
Coupling device for pressure gauge cum switch for connecting gas handling plant for SF6 circuit breaker (2 no. of each type)
Fixed, moving and arcing contacts for SF6 circuit breaker including insulating nozzles (3 nos. of each type)
Auxiliary contacts for 245KV GIS circuit breaker
Auxiliary switch assembly for SF6 circuit breaker 2 nos of each type
Limit switch & Auxiliary contacts for 245KV GIS DS and MES
Rubber gaskets, 'O'-ring and seals for SF6 circuit breaker (1 no. each type)
Operation counter of SF6 circuit breaker 2 nos. of each type
SF6 gas in steel bottle (20% of total weight)
All types of coupling for SF6 gas (2 no. of each type)
spring charge motor for 245KV GIS circuit breakers
Pipe length (copper/ steel as applicable) for SF6 circuit of each type
Relays, power contactors, push buttons, timers and MCBs etc of each type and rating
Windowscope/ observing window 2 nos. each type
Complete Drive for 245KV GIS circuit breaker:
Complete drive mechanism for disconnect switches and grounding switches for 245KV GIS
Motor for disconnector switches and grounding switches for 245KV GIS
Complete drive mechanism for fast acting grounding switches for 245KV GIS
Covers with all accessories necessary to close a compartment in case of dismantling of any part of the enclosure to ensure the sealing of that compartment
Motor for fast acting grounding switches for 245KV GIS
Rupture disc for circuit breakers / potential transformer for 245KV GIS (2 nos. of each type)
Rupture disc for other compartments for 245KV GIS
Limit switch & Aux Switch for 245KV GIS
Bus supplort insulator of each type for 245KV GIS
UHF PD sensors with BNC connector
Limit switch & Auxiliary contacts for 245KV GIS HSES (one complete MOM box)
Complete Spring Operating Mechanism including charging mechanism etc. of each type
Complete set of 3-phase dis-connector of each type including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Isolator by spare
Complete set of 3-phase Maintenance Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc to enable complete one to one replacement of all applicable type of Earth Switch by spare
Complete set of 3-phase Fast Earthing switch of each type,including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare (if applicable)
Copper contact fingers & corona shield for dis-connector male & female contact–for one complete (3-phase) dis-connector of each type
Copper contact fingers & corona shield for Maintenance Earthing switch male & female contacts, for one complete (3- phase) earthing switch of each type
Copper contact fingers & corona shield for Fast Earthing switch male & female contacts, for one complete (3-phase) earthing switch of each type (if applicable)
Open/Close contactor assembly, timers, key interlock, interlocking coils, relays, push buttons, indicating lamps, Power contactors, resistors, fuses, MCBs & drive control cards etc. one of each type for one complete MOM box for a) disconnector b) Maintenance earth switch c) Fast acting earth switch
Complete Gas insulated Surge arrester of each type and ratings with enclosure and insulator (if applicable)
Surge counter/ monitor of each type (if applicable)
Enclosure insulator of each type for 245KV GIS complete with metal ring etc.
Gas barriers alongwith insulator complete with metal ring
Buffer Cylinder complete for breaker
Accumulator/Pr. Storage cylinder for breaker
Fixed and Moving Arcing carrying contacts for DS and ES
Lifting Hooks, Belts of various size for GIS equipment handling
For 220/132/33KV,160MVA Auto Transformers
245kV H.V. Bushing (RIP/RIS) with metal parts and Gaskets
145KV IV bushing (RIP/RIS) with metal parts and Gaskets
72.5 kV LV Bushing (RIP/RIS) with metal parts and gaskets
Neutral Bushing with metal parts and gaskets
Local and remote winding temperature indicators with alarm and trip contacts and maximum reading pointer
Oil temperature indictor with alarm and trip contacts and maximum reading pointer
Pressure relief device for main tank
Pressure relief device for OLTC
Silica Gel breather
Maintenance free breather
Magnetic oil level gauge with low oil level alarm contacts
Oil flow indicator with contacts
Cooler pump with motor
Cooler fan with motor.
Buchholz relay.
Tap position Indicator (Local and remote)
Oil sampling bottle
Oil Surge Relay
Complete set of gasket (complete set for one transformer)
Set of valves (complete set for one transformer)
Air cell rupture relay
Spare cartridge for ODS
Expansion Joint (Complete replacement for transformer)
220 kV AIS Spares
220 Kv CVT
245 kV Complete Isolator assembly with operating mechanism except structure
132 kV AIS Spares
132kV Current Transformers(One of each ratio)
132kV Potential Transformers,
132kV CVT
132kV Lightning Arrester
145 kV Complete Isolator assembly with operating mechanism except structure
132kV CB pole
Interrupter for 132kV CB pole
Tripping Coil for 132 SF6 CB
Closing coil for 132kV CB
Gas filling device for SF6 breakers
72.5 kV AIS Spares
72.5 kV Current Transformers(One of each ratio)
72.5 kV Potential Transformers,
60 kV Lightning Arrester
72.5 kV Complete Isolator assembly with operating mechanism except structure
72.5 kV CB pole
Interrupter for 72.5kV CB pole
Tripping Coil for 72.5 SF6 CB
Closing coil for 72.5kV CB
Gas filling device for SF6 breakers
33 kV AIS Spares
33 Kv DO fuse
220KV Control and Relay Panel
Distance Protection relay (Main I)
Distance Protection relay (Main II)
Transformer Differential relay (Main I)
Transformer Differential relay (Main II)
Master Trip relay
Trip Circuit Supervision relay
DC Changeover Relay
DC Supervision relay
LBB Trip Relay (96)
AC Supervision relay
132KV Control and Relay Panel
Over current and Earth fault relay
Distance Protection relay
Line Differential relay (Main I)
Line Differential relay (Main II)
Transformer Differential relay (Main I)
Transformer Differential relay (Main II)
Master Trip relay
Trip Circuit Supervision relay
DC Changeover Relay
DC Supervision relay
LBB Trip Relay (96)
AC Supervision relay
For 72.5 KV Control and Relay Panel
Over current and Earth fault relay
LBB Trip Relay (96)
DC Circuit Supervision Relay (80)
Master Trip relay
DC Changeover Relay
Trip Circuit Supervision relay
Ethernet switch
FO cables with end termination equipment for each type and length between IEDs (One FO cable for each type/length)
For PLCC(one set of modules each for digital PLCC and Digital Protection Coupler )
For Cable Termination Kit
Patch/Cu cable with terminations of each type and length between IEDs of Station level (One cable for each type/length)
Any interface/Protocol converter (One for each type)
BI/BO card for each type of IED (one no each).
Power card for each type of IED (one no each)
Transducers of each type (one no each)
Industrial grade computer.
Testing Kit for Transformers
Automatic Transformer Oil BDV Testing Kit
Oil Storage Tank - 20kL Capacity capacity with towing arrangement
Stainless Steel Oil sampling bottle (One Litre Capacity)
Syringes for sampling oil
PLCC Testing Equipments
For PLCC(one set of modules each for digital PLCC and Digital Protection Coupler ) for each voltage level
Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 250 km)
Digital Protection Coupler, 8 command with redundant power supply card and CPU along with relay and E1 interface card and optical card.
Handheld Signal level meter cum Signal level generator (Electronika ET91/ET92N4L SLM 3505 or better)
LCR meter : (Tegam 3550/Salicon Nano 8110G or better)
Spectrum Analyser (Techtronix RSA 503A with tracking generator, general purpose modulation analysis, VSWR return loss cable fault attenuation measurements options enabled along with waterproof Panasonic Thought book Tablet or equivalent/or better specification from makes of Agilent /Rohde and Schwarz
Oscilloscope (Rohde & Schwarz RTM 3K-4M or better specifications from Agilent,Techtronix)
132 Kv Spare Cable Termination Kit
OPGW Cabling
96 Fibre (DWSM) OPGW fibre optic cable
96 Fibre Optic Approach Cable (DWSM96F)
OPGW Hardware Fiitings and Termination
OPGW Suspension Assembly with twisted link c/w pre-formed armour rods and tower bond clamps
OPGW Suspension Assembly with chain link c/w pre-formedarmour rods and tower bond clamps
OPGW double tension pass through assembly
OPGW Splicing Tension Assembly in Suspension tower
OPGW Double Tension Assembly for splicing location c/w pre-formedarmour rods and tower bond clamps
OPGW Tension Single Dead-end Set for termination/ run-in c/w pre-formedarmour rods and tower bond clamps
OPGW Vibration Damper c/w pre-formedarmour rods
Down Lead Clamp
OPGW optical Splice Kit (48 fibre) including junction box
OPGW Optical interface Joint kit and Junction for line/sub interface on substation gantries
Down Lead CFODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails lamp
Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable ties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
SPARES FOR BATTERY CHARGER
Set of control cards for 220V Battery charger
Set of relays for 220V Battery charger
Thyristor/diode for 220V battery charger
Fuses of thyristor with indicator for 220V battery charger
Set of control cards for 48V Battery charger
Set of relays for 48V Battery charger
Thyristor/diode for 48V battery charger
Fuses of thyristor with indicator for 48V battery charger
Additional spares for each voltage level
Conductor Clamps (Suspension Clamp, Tension Clamp, T Clamp, Spacer, PG Clamp, welding sleeves etc.) used in Substation for each voltage level (220/132) (30% spares)
Equipment Connectors, 20 nos. of each kind for each voltage level (220/132)
Patch cords (of different lengths) required for CRPs of each voltage level (220/132) and SAS and any in any other area.
1.1 kV Control and Power Cables for existing GIS (as per requirement)
Any interface/Protocol converter (One for each type)
BI/BO card for each type of IED (one no each).
Power card for each type of IED (one no each)
Transducers of each type (one no each)
ACSR Zebra Conductor
ACSR Panther Conductor
Industrial grade computer.
Special Tools and Kits
Portable N2 dew point meter: Make :VASTHI Model : -VD H2
SF6 gas bottle locking, measuring and filling assembly with all hose for filling and top up
Thermal imaging camera Make Fluke , Model No. TIX580
Spl. Tools dismantling, o/h and reassembling og breaker and other compartment
CT / PT Analyser Make : Megger Model :-MVCT
Portable Partial Discharge monitoring with laptop and software Make Qualitrol Model No. QCM-PPDM
Digital weighing machine
Industrial hot blower for treating gas pipe, monitors etc.,
Micro wave oven for desiccant reactivation
Industrial vacuum cleaner
Torque Wrench (0 – 50Nm, 40 – 200Nm, 100 – 500Nm) (TAPARIA)
Ratchet spanner set (box spanner) 8 – 42 mm (TAPARIA)
Ring spanner & D spanner 6 – 41 mm, (TAPARIA)
Double End spanner 10 – 41 mm (TAPARIA)
Allen key 1 – 12 mm (TAPARIA)
Digital Multimeter (FLUKE /Megger)
Clamp on meter (0 - 20A, 20 – 200A, 200 – 2000A) (Megger/Fluke)
Clamp on leakage meter (0 – 20 mA, 20 – 200 mA, 0.2– 2A) (Megger/Fluke)
Contact resistance meter : Make – Scope Model No. : CRM100B+
DC Tong tester (FLUKE)
10KV Digital Power Insulation Tester (IR Meter) Make: Megger
Digital Earth resistance measuring kit Make: Fluke/Megger
Earthing Stick for each voltage level
First Aid box
Accident prevention chart
Aluminium alloy ladder
Safety belt
415V, 63/32 A Industrial socket for electrical room and outdoor
415V, 2000 Watt induction heater with reflector and microprocessor based temperature sensor and with cabling for control room.
Computer with printer (As per customer requirement)
Industrial Helmet
Motor for Pumping Water (5 HP) CROMPTON/BAJAJ/KIRLOSKAR
SF6 Gas leak detector for 132kV & 33kV CB Make DILO Model No. 3-033-R002
Insulated Screw Driver set (6" - 18"), Tester, Tie, Wire cutter, Pliers (6", 8", 12"), Nose Pliers (6"), Wire Striper 6" (TAPARIA)
Transformer turn ratio kit Scope Model TTRM 302
Breaker Timer kit : Make – Scope, Model SCOT M3K
Winding resistance kit Make : - IBEKO (DV POWER) Model TWA 25A
PPM kit Make : METRO OHM Model No. 899 Coulometer
CT Injection Kit Make Megger Model ODEN AT/3s with suitable current injecting cable to inject upto 2500 A
Tan delta test kit Make : Megger, Model:- Delta 4110
LA Test kit Make – BEACON Type LCA
Relay testing kit Omicron CMC 356 With complete softwares for testing Diiferential, Distance, Auto-recloser, Over voltage , Overcurrent , Advance distance, Advance differential etc. along with relay management softwares.
Wrench kit, Sly Wrench, Pipe Wrench kit, Socket Wrench kit, Hand Gloves (10 Pair), Free size Boots (10 Pair), Slide wrench (12" and 18"), wire clamping tool upto 16 mm, Vernier Calliper(8", 12", 16") (TAPARIA)
Chain pulley block 3 Ton capable of lifting upto 10 m
Hydraulic Crimping tool kit dies with variable dia for ACSR & AAAC conductors (Panther, Zebra, Moose, ACCC Drake, ACCC Casablanca)
Hoist Device capable of pulling 10 Ton Load
Derrick Pole
Hook stick (resin Bond folding type)
Drill Machine and Drill bit power operated upto 19 mm RANGE
Grinder power operated 7 "
Haxes (4", 6")
Flat, Round and half round files
16mm steel rope
20mm polypropylene rope
Slings of Various sizes and capable of carrying 10 Ton Load (each 3 meter long)
Man Lifter Crane
Hydraulic cutting machine
Electric cutting machine
Portable welding machine
Tommy rod
Single Pulley (Open)
Double pulley
Hammer 5kg
Jungle cutting machine
FORSLIP PULLEY COMPLETE SET
Tirfor machine
Dee Shackle
0.5’’, 0.75’’, 1’’ steel rope
Medicine spray machine
Training
Trainiing as per different Clauses of Volume II of BID Document
Additional items required for completion of the project
Tenderer(s) to specify
US Dollar
European Dollar
Japanese Yen
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid