CONSTRUCTION OF BRIDGE IN FRONT OF DADA BHAGVAN TRIMANDIR LOCATED BETWEEN DUKHIYANA DARBAR ROAD TO DFCC RAILWAY LINE ON HAZIRA BRANCH CANAL OF KAKRAPAR RIGHT BANK CANAL DIVISION PASSING THROUGH ABRAMA VILLAGE IN NEW EAST (SARTHANA) ZONE (2 nd Attempt) (WORK NO. 01).
365185
ACE& I/C CE/BRIDGE/07/2026-27(Work No. 01)
Open
Civil - All
Works
Surat
3 documents required · 3 mandatory
₹7,080
Commissioner, Surat Municipal Corporation
₹3.1 L
16 Nov 2026
16 Nov 2026
16 Nov 2026
23 Nov 2026
16 Nov 2026
120 days
NAME OF WORK : CONSTRUCTION OF BRIDGE IN FRONT OF DADA BHAGVAN
TRIMANDIR LOCATED BETWEEN DUKHIYANA DARBAR ROAD TO DFCC
RAILWAY LINE ON HAZIRA BRANCH CANAL OF KAKRAPAR RIGHT BANK
CANAL DIVISION PASSING THROUGH ABRAMA VILLAGE IN NEW EAST
(SARTHANA) ZONE(2 nd Attempt) (WORK NO. 01).
1 The project envisages Construction as detailed in the scope of work. For guidance of
bidders outline drawings showing the general arrangement contemplated by the employer
are attached in Volume-I.
The typical outline drawings enclosed are to be taken as indicative except for certain salient
parameters, obligatory requirements etc. which have been specified in bidding data in Vol -
I. These outlines also specify the minimum acceptable mix, specification and sizes of
different components and If various items and activities as per scope of work of the tender
document are not found to be included in Contractor’s technical proposal, drawings and
technical note, then the lump sum offer quoted by the Contractor shall be presumed to be
inclusive of all such items, specifications and activities as per scope of work in the tender
document. No extra payment shall be paid for the same.
2 The bidder must quote his offer at the specified space in the PRICE BID both in words and
figures. The price bid should be submitted online.
3 The offer quoted shall except in so far as it is otherwise provided under the contract, include
all constructional plant, labour, supervision, all construction materials, all leads and lifts,
erection, maintenance, insurance, profits, taxes (excluding GST) , octroi, royalties and
duties together with all general risks, liabilities and obligations set out or implied in the
contract. Materials to be used in embankments and unserviceable materials to be disposed
should be with all leads and lifts.
4 In case of any discrepancies between provisions stated in the scope of work and those
covered by the technical specifications / drawings, the provisions in the scope of work shall
have preference.
5 The bidders shall quote his offer in Indian Rupees only.
6 The price quoted for the job shall be deem to cover entire cost of material, labour,
plants, Equipments, enabling works, overheads, Profits and all that is required to complete
the intents and purpose of the contract without any additional payment called for.
7 The rates quoted by the Contractor must be inclusive of all taxes prevailing on due date of
bid submission except GST. However, any subsequent changes in the tax structure by
Government after due date of bid submission will be compensated (+/-) on availability or
submission of actual documentation. Contractor will have to intimate Engineer regarding
changes occurred in the tax structure after bid submission. if the contractor fails to
provide such information and if any financial obligation may arise due to change in tax
structure. same will be recovered from the contractor. GST will be paid separately on the
bills. Hence, it is the responsibility of the contractor to pay the GST to the concerned
Surat Municipal Corporation
[Bridge Department]
CONSTRUCTION OF BRIDGE IN FRONT OF DADA BHAGVAN TRIMANDIR
LOCATED BETWEEN DUKHIYANA DARBAR ROAD TO DFCC RAILWAY LINE ON
HAZIRA BRANCH CANAL OF KAKRAPAR RIGHT BANK CANAL DIVISION
PASSING THROUGH ABRAMA VILLAGE IN NEW EAST (SARTHANA) ZONE
(2 nd Attempt) (WORK NO. 01).
Memorandum showing items of works to be carried out
RECAPITULATION SHEET
NO. DESCRIPTION AMOUNT (Rs.)
1 Bridge + Approach slab Portion Rs.
2 Electrical works Rs.
Rupees Three Crores Five Lacs Eighty Six Thousand Three hundred thirty
eight & point ten only
I/We am/are hereby agree/agrees to carry out the aforesaid work as per tender condition at ___%
above / below ( percentage above/below) of the estimated tender amount. The amount of my/our
tender for aforesaid work is Rs...............................(In word Rupees................................)
1) % above / below is to be submitted online only.
2) All work shall be carried out as per the specifications or as directed.
3) Rates quoted include cleaning of site (prior to commencement of work and at its close) in all
respects and hold for work under all conditions, site moisture, weather, etc.
4) Rate qouted after a visiting the site and verified the quantity of work done and balanced work.
5) The rates quoted by the Contractor must be inclusive of all taxes prevailing on due date of bid
submission except GST.
Signature Signature
Contractor Executive Engineer (Bridge Department)
Surat Municipal Corporation
[Bridge Department]
CONSTRUCTION OF BRIDGE IN FRONT OF DADA BHAGVAN TRIMANDIR
LOCATED BETWEEN DUKHIYANA DARBAR ROAD TO DFCC RAILWAY LINE ON
HAZIRA BRANCH CANAL OF KAKRAPAR RIGHT BANK CANAL DIVISION
PASSING THROUGH ABRAMA VILLAGE IN NEW EAST (SARTHANA) ZONE
(2 nd Attempt) (WORK NO. 01).
Item Item Description Unit Qty. Rate in Rs. Amount
1 Clearing and grubbing site/road/land including Hectare 0.10 28455.09
uprooting all vegetation, grass, bush shrubs, saplings
and trees with girth, removal of stumps of trees of girth
of all sizes including removing stumps of trees cut
earlier and disposal of unserviceable materials and
stacking of serviceable materials as directed by
Engineer with all leads and lifts etc. complete as per
specification. before commencement and after
completion of the work.
2 Carry out survey work using total station (1 second LS 1.00 145187.50
accuracy) for the length and width of existing area &
structures as decided by Engineer in charge and additional
length if required. The width to be surveyed will be up to
TP Boundary and beyond that as required, including
marking of TBM, its coordinates, station points, their
coordinates, centre line of alignment, taking ground level
details of existing structures, details of all utilities below
GL, manholes, catch pits, existing utility services, light
poles, trees, over head electrical lines, BSNL section pillar
/ box, Torrent electrical boxes, including any number
marked on them, road dividers, foot paths, culvert, Bridge,
etc. within construction area and additional areas / lengths
if required. Rate includes fixing TBM & necessary
reference pillars, fixing alignment at site, establishing
bench mark, establishing foundation layout, and pier
coordinates, on ground, including submission of
longitudinal sections, cross sections, drawing report etc. of
survey work in three hard copies with soft copy in CD to
Engineer-incharge as directed for the Fly over bridge.
3 Providing and installation of temporary barricades sqm 115 532.27
including supplying, painting with fluorescent paint/white
paint and fixing CGI sheets 0.8 mm thick of 1.8 m height
and M.S. Posts angle 40 x 40 x 5 mm at 2.5 m c/c and
dismantling the same after completion of work and
allowing for movement of traffic as per drawing and as
per instruction from Engineer in charge. Necessary
arrangements shall be made to divert the existing traffic in
an unobstructed manner.
Rate to be inclusive of all materials, fabrication works,
paint works, retroreflective films / sticker, foundation
works, transportation, loading, unloading, installation,
dismantling and inclusive of all taxes and including the
same design for providing open able gate. No extra rental
will be given to the contractor in case of any delays on his
part for construction or due to any valid time limit
extensions. Each barricading sheet is to be numbered with
a unique number. If shifting of barricading is required
with in the project boundary than contractor should shift /
relocate the same sheet/barricades as required and no extra
payment made for shifting / relocation. After the
completion of project, the ownership of barricading will
remain with the contractor.
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
Barricading is to be cleaned as per the instruction of
Engineer in charge. (i.e. Temporary barricading will be
property of contractor after completion of work. Rate is
only for providing temporary work during construction
4 Supplying installation testing & commissioning of Nos 5 248.00
Blinkers like for height barriers complete in all respect.
It should be in working condition until the completion
of project. Payment should be done at 70% at the time
of installation and 30% at the end of project. After
completion of work, it should be property of contractor.
5 Dismentaling the existing structure including removing
and stacking the dismentalled materials as and where
(A) RCC Work Cum. 25 1110.75
(B) Rubble Masonary Work Cum. 25 577.92
(C) Steel Work kg 50 3.85
(D) CC Work Cum. 25 50.11
6 Excavation for foundation of structures including Cum. 275 526.15
existing pavement surfaces including dewatering,
shoring and strutting as necessary and backfilling the
trenches with suitable excavated material in layers of
15 to 20 cms and disposing of remaining unsuitable
material with all lifts and lead as directed and
preparation of bed for concreting of foundations etc.
complete as directed by Engineer and as per
7 Providing and laying in situ machine mixed M-15 Cum. 80 3695.35
grade bedding concrete in foundation / below pile cap
including dewatering, shuttering, compacting, curing
etc. complete true to level and position as directed by
Engineer and as per specification.
8 Empty boring through all sorts of strata for providing
RCC bored piles to required depth including flushing
necessary casting pipe with all plants and equipments
as required as per detailed specifications for Abutment
and Piers (Excluding Concrete & Reinforcement)
1000 mm dia Pile Rmt 525 2818.61
9 Providing and casting in situ machine mixed controlled Cum. 415 4965.04
cement concrete M-35 for RCC bored pile using
Tremie Pipe including necessary flushing, dewatering,
formwork, transporting, compacting, vibrating,curing
and finishing including all leads & lifts complete as per
detailed specifications. (Excluding Reinforcement)
9A Chipping and dressing of the RCC piles upto cut-off Cum. 35 955.41
level as given in drawing including cleaning of
reinforcement and removal of dismantled materials,etc.
for providing pile caps as directed by Engineer and as
per specification. For any dia size of RCC pile
10 Carrying out load test on any pile as per standard
procedure laid down in the IS:2911 specification
including construction of test cap, dismantling the cap
after test and cleaning the site and maintaining
complete records of load settlement as directed by
Engineer and as per specification, and submission of
a) Initial Pile Load Test on piles for 2.5 times the design No. 1 163953.30
load specified in drawings in non working areas in the
vicinity of the bridge site, including cost of test pile.
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
b) Carrying out High strain Dynamic Test on any working No. 1 98371.98
pile / Test pile as selected by the Engineerin-charge.
The test shall be carried out by agency approved by
Engineer in charge as per IRCNotification 54 and
submitting results / reports in three hard copies with
soft copy in CD. Item includes all necessary
arrangements required for the test. (with guided frame
11 Performing Integrity Test (low strain) on all vertical
pile. The item shall include chipping of weak concrete
at the top of pile, leveling, bending of reinforcing bars,
preparation of pile head including testing with pile
driving analyzer or approved equivalent. To be carried
out at least 15 days after concreting of piles. A
specialist approved Agency shall be employed by the
Contractor for the test. The test shall be carried out as
per relevant IRC 78. The item is including complete
testing with approved apparatus, analysis of results and
conclusions including submission of test reports in
three hard copies with soft copy in CD.
1000 mm dia Pile No. 19 1629.13
12 Providing and installing 6 mm MS liner for bored-cast- MT 5 47323.73
in-situ concrete piles including applying protective
coating as per drawing and specification and as directed
13 Providing and laying in-situ machine mixed RCC M-35 Cum. 180 5164.08
grade Controlled Cement Concrete in foundations of
Abutments pile caps etc.at any depth including
centering, shuttering, mixing in mechanised batch mix
plant, compaction, curing and dewatering if necessary,
excluding reinforcement as per specification and as
directed by Engineer.
14 Providing and laying machine mixed M-35 grade
Controlled cement concrete for cast-in-situ side wall
etc. at any height or depth as per approved design and
drawings, with necessary centering, shuttering,
scaffolding, transporting, placing, compacting by
mechanical vibrators, finishing, curing and casting as
per drawing etc. complete excluding reinforcement as
directed by Engineer and as per specification.
Upto 5 m height Cum. 15 5508.21
15 Providing and casting in situ controlled cement Cum. 15 5587.99
concrete M-35 for R.C.C. work in Dirt wall including
controlled cement concrete M-40 bed blocks or
pedestals of required size below bearings as per
detailed drawings, centering, shuttering, scaffolding,
wherever necessary,layingvibrating, curing and
finishing complete.
Pedestals in M:40 Cum. 3 5561.55
16 Providing & fixing in position (Thermo mechanically treated
bars) TMT Fe550D With CRS steel bars of various diameters
for all RCC works in Piles, Piles Caps and foundations as per
detailed design & drawings and schedule including cutting,
bending, hooking the bars, binding with 18 SWG GI wires or
tack welding (only for piles) and supporting as required with
all lifts and leads etc. complete including cost of all labour,
materials, tools, plants, equipments etc. all complete as
directed by Engineer and as per specification.
a) Pile MT 79 74740.17
b) Pile Cap MT 19 74942.42
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
17 Providing & fixing in position (Thermo mechanically MT 4 74942.42
treated bars) TMT Fe550D with CRS conforming to IS
1786 reinforcing steel bars of various diameters for all
RCC works in Dirt wall,sidewall, Pedestals as per
detailed design & drawings and schedule including
cutting, bending, hooking the bars, binding with
SWG GI wires and supporting as required with all lifts
and leads etc. complete including cost of all labour,
materials, tools, plants, equipments etc. all complete as
directed by Engineer and as per specifications. The
rate includes for supply, loading, unloading,
transporting to site, cutting, bending, hooking, placing,
tying in position with contractor's own binding wire,
welding, forming the cage and lowering it in position in
pile bore etc. Welding and supporting in position to
ensure lines and levels during concreting, maintaining
proper cover / spacing, all leads & lifts, etc. including
contractor's own equipment, labour, supervisor, taxes,
machineries, etc. complete as per drawings and
18 Providing and fixing in position fully moulded Cucms. 36000 0.90
restrained elastometric Bearings as per detailed
19 Providing and applying one coat of zinc-rich epoxy Sqm. 345 132.00
primer and two coats of coal tar epoxy paint of reqd.
thickness as per specifications to all concrete surfaces
in contact with earth in foundation and substructure
including all cost of material, labour, transportation and
preparing the surfaces by cleaning, washing, brushing,
sand/grit blasting etc. complete as directed by Engineer
and as per specification. (Paint shall be got tested from
approved laboratory).
20 Providing and applying anti carbonation, antifading, Sqm. 140 121.72
mold resistant, heat insulating and 100% acrylic
breathable decorative external waterproof coating of
approved shade having viscosity @ room temperature
by Ford cup No. B-4 (dilute 2 parts of product with I
part of water) 18 to 30 sec. pH of 7.00 to 10.00 and
specific gravity @ Room temperature 1.30+0.1, tested
for carbon dioxide diffusion resistance properties for
coating materials and coating systems for exterior
masonry and concrete as per DIN EN 1062-6 (2002-
a NBA Grade "A" accredited institution.
21 Providing and Filling sand behind Abutment side Wall Cum. 125 562.08
in layer as directed.
22 Providing and Laying Filter media 600mm thk as Sqm. 60 1311.18
directed at the back of abutment as per detailed
23 Providing and Laying weep holes in abutment and Nos. 60 89.20
return by using A.C. pipes of 100 mm diameter with
laying in proper grade and jointing complete etc. as per
detailed specifications.
24 Providing and casting in situ controlled cement Cum. 65 7659.34
concrete M 40 for concrete work in super structure
including centering, shuttering, curing, scaffolding,
ramming, vibrating, finishing, launching or shifting
complete. (i) Deck Slab.
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
25 Supplying, fabrication, assembling of all types of steel MT 80 135037.28
sections of specified spans with structural steel
conforming to Quality "B0" Grade Designation E250
conforming to IS:2062, erection / slewing / end launching
of steel sections with cranes or any other approved
launching methods as per site conditions (not requiring
traffic block) on substructure including provision of
trolley refuges etc., complete as per approved QAP and
drawings conforming to IRS-B1-2001 and other relevant
codes and specifications.Note:1. Detailed fabrication and
erection drawings & launching methodology will be
prepared by the contractor and got approved from
Railway.2. The rate is all inclusive including launching in
position, complete in all respect except cost of (i) Painting
/ Metalising; (ii) Bearings & (iii) welding which shall be
paid extra under relevant item.3. The payment shall be
made on the theoretical weight of main components and
gusset plates only.4. Payment Schedule:(i) Receipt of
material at site: 40%(ii) Fabrication of girders: 20%(iii)
Erection/Launching: 20%(iv) Completion in all respects:
26 Extra for using steel conforming to Grade Designation MT 80 4818.13
E350 instead of Grade Designation E250 of Quality
"B0" as per IS:
27 Metallizing of steel work of girders with sprayed Sqm. 720 655.63
aluminium after surface preparation by Sand/grit
blasting, followed by one coat of etch primer (IS:5666)
& one coat of Zinc Chrome primer (IS:104) and two
coats of aluminium paint (IS:2339) with all labour,
T&P and material as a complete job duly conforming to
all relevant specifications and process given under
Clause 39 of IRS-B1-2001. Note: Nominal Thickness
of sprayed Aluminium coating shall be 150 microns.
DFT of Zinc chrome primer shall be 25-30 microns and
DFT of each coat of Aluminium paint shall be 12-14
microns. On new girder during fabrication
28 Supplying and fixing HSFG bolts of any dia and any KG 2400 316.41
length with suitable nuts including DTI washers
conforming to IRS-B1-2001 for bridges and steel
structures with contractors labour, tools and plants and
lead and lift etc., complete.
29 Providing Sacrificial shuttering for deck slab made up KG 3640 131.83
with galvanized Cold rolled cold annealed (CRCA)
steel of 310 MPA Grade with all contractor's material,
labour, erection, fixing, welding etc. complete with all
lead and lift and all safety precautions. Rate is inclusive
of structural design of the sacrificial shuttering by
contractor at their own cost. Note: (i) Rate of sacrificial
shuttering (galvanized CRCA 310 MPa Minimum
mm thick) for deck slab is inclusive of preparation of
detailed structural drawing supported with required
calculation duly proof checked by Govt. Engineering
College. No extra payment for development of design
and drawing of decking sheet or its proof checking is
30 Providing & fixing in position (Thermo mechanically
treated bars ) TMT Fe550D With CRS steel bars of
various diameters for all RCC works in super structure
as per detailed design & drawings and schedule
including cutting, bending, hooking the bars, binding
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
with 18 SWG GI wires and supporting as required with
all lifts and leads etc. complete including cost of all
labour, materials, tools, plants, equipments etc. all
complete as directed by Engineer and as per
specifications.
Deck Slab M.T. 8 75812.23
31 Providing and applying anti carbonation, antifading, Sqm. 95 121.72
mold resistant, heat insulating and 100% acrylic
breathable decorative external waterproof coating of
approved shade having viscosity @ room temperature
by Ford cup No. B-4 (dilute 2 parts of product with I
part of water) 18 to 30 sec. pH of 7.00 to 10.00 and
specific gravity @ Room temperature 1.30+0.1, tested
for carbon dioxide diffusion resistance properties for
coating materials and coating systems for exterior
masonry and concrete as per DIN EN 1062-6 (2002-
2010) by a NBA Grade "A" accredited institution.
32 Providing and carrying out load test on bridge deck M.T. 200 169.92
with simulated loading including provision, placing and
removal of loading, supplying, fixing and removing
deflection measuring instruments etc. complete with
platforms for fixing the instruments etc. complete as
per the details supplied and specification and as
directed by Engineer and including submission of
required results in triplicate after satisfactory
completion of the load test.
33 Providing and laying of a strip seal expansion joint Rmt 25 6096.14
catering to maximum horizontal movement upto
mm, complete as per approved drawings and standard
specifications to be installed by the
manufacturer/supplier or their authorized representative
ensuring compliance to the manufacturer's instructions
for installation.
34 Providing and laying DENSE GRADED BITUMINOUS MT 40 3443.09
MACADAM (DBM) as per gradation and bitumen for
mixing shall be as arrived from mix design, provided in no
case it shall be less than 4.0% for Grade I and 4.5% for
Grade II by wt. of total mix as binder by batch mix type
hotmix plant and laying by sensor paver finisher including
consolidation by rollers as specified including providing
and operating plant, sensor paver and machinery, cost of
fuel, oil lubricant and labour charges, tests requied to be
carriedout including cost of aggregate and filler (if found
required as per mix design)etc (But including cost of
providing bitumen )A) 4.50% bitumen (Including cost of
bitumen) DBM-II
35 Supplying and applying Rapid Setting-1 (RS-I) Sqm 325 14.24
bitumen emulsion confirming to IS 8887, for
application of Tack coat before application of
wearing course at the rate of 0.25 kg. per Sq.
Meter area, including all materials, labour,
machinery, tests required to be carried out with all
leads and lifts etc., complete as per details in tender
specification & as directed by engineer in charge.
36 Providing and laying 25mm to 50mm thick compacted MT 20 3887.49
BITUMINOUS CONCRETE (BC) using aggregates as
per gradation and percentage of bitumen for mixing
shall be as arrived from mix design, provided in no
case bitumen percentage shall be less than 5.2% for
Grade I and 5.4% for Grade II by Wt. of total mix as
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
binder by batch mix type hot mix plant and laying by
sensor paver finisher including consolidation by rollers
as specified including providing and operating plant,
sensor paver and machinery, cost of fuel, oil, lubricant
and labour charges, tests requied to be carriedout
including cost of aggragate and filler (if found required
as per mix design) etc. complete (including cost of
providing bitumen ) BC-II
37 Providing & Laying Bitumen painting (VG30) by Sqm 325 33.66
mechanical sprayer on wearing course(BC)surface
using bitumen @ 5.0kg. / 10.0 S.M. And spreading
stone dust @ 0.03 C.M. / 10.0 S.M. On painted surface
including operating cost of contractor's own equipment,
fuel, lubricants, carting of required materials, all labour
and material cost (including cost of bitumen) preparing
surface by brushing with wire brushes, sweeping with
mechanical broom / compressed air and finally fanning
the cleaned surface with gunny bags to remove all
loose dirt etc. completeas per details in tender
specification & as directed by engineer in charge.
38 Providing and casting RCC in M-40 controlled Cum. 25.0 5234.87
concrete Crash Barriers as per detailed drawings
including necessary scaffolding, centering, formwork,
mixing in machine, transporting, placing, compacting,
finishing, curing, etc. complete including providing and
fixing of inserts if any with all leads and lifts as per
drawing & specification and as directed by Engineer,
excluding reinforcement.
39 Providing and casting insitu controlled cement concrete Cum. 20.0 5360.27
M-30 in RCC Approach Slab including formwork,
curing and finishing complete.
40 Providing and fixing in position (Thermo mechnically M.T. 10 74326.75
Treated bars) TMT Fe550D With CRS reinforcing bars
of various diameters for the above all RCC works as
per detailed designs and drawings and schedule
including cutting, bending, hooking the bars, binding
with 18 SWG GI wires with cost of all labour,
materials, tools, plants, equipments, supporting as
required with all lifts and leads etc. all complete as per
specification and as directed by Engineer. (Approach
slab, Crash barrier)
41 Providing and fixing 100 mm dia. G.I. Drainage spouts, Nos. 10 536.03
as per MOST Drg. No. SD/303 including grating with
suitable clean out fixtures including all leads and lifts
etc. complete as per specification, design & drawings
and as directed by Engineer.
42 Direction (Junction) Sign :-Providing and fixing sign Nos 2 26572.09
boards made out of 2mm aluminium sheet / 4mm ACP
(Aluminum composite Panel); size 244x122 cms.
rectangular as per design of IRC-67-2012. Pre treated
with phospheting process & acid etching; coated with
one coat of epoxy primer and two coats of best quality
epoxy paint ; reflectorised with High Intensity
Prismatic Grade retro refiectivesheeting of Type-4 as
per ASTM D-4956 and latest M.O.S.T.Specifications;
4.0mtr (2 Nos.) long stand post of Iron Angle 75 x 75 x
6mm / 65NB Circular MS Pipe as required and frame
fabricated from suitable size iron angle of 50x50x5mm;
painted with bestquality epoxy coatings in black and
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
white bends. The details of symbol for each board shall
be as per the instruction of engineer in charge. The
fixing at site shall be in 1:2:4 CC blockof size 45 x 45 x
60 Cms. for each leg including excavation, curing
etc.complete under the supervision of engineer in
charge. A warranty for 7 years for the Retro reflective
sheeting from original manufacturer & a certified copy
of 3 year outdoor exposure test report from third party
test lab for the product offered shall be submitted by
contractor. (A) Class-C Type-11 Retro Reflective
43 Regulatory/ Mandatory Signs :- Providing and fixing Nos. 2 4618.73
sign boards made out of 2 mm aluminium sheet; size
cms. diameter circle as per design of IRC 67-1977. Pre
treated with phospheting process & acid etching;
coated with one coat of epoxy primer and two coats of
best quality epoxy paint; reflectorised with retro
refiective sheeting as per latest M.O.S.T.
Specifications; 3.1 m long stand post and frame
fabricated from suitable size iron angle of 35 x 35 x
mm, 75 x 75 x 6 mm as required; painted with best
quality epoxy coatings in black and white bends. The
details of symbol for each board shall be as per the
instruction of engineer in charge. The fixing at site
shall be in 1:2:4 CC block of size 45 x 45 x 60 Cms. for
each leg. including excavation, curing etc. complete
under the supervision of engineer in charge. (A) Class-
C Type-11 Retro Reflective sheeting
44 Cautionary warning sign :- Providing and fixing sign Nos. 2 5077.27
boards made out of 2 mm aluminium sheet; size 90 x 90 x
90 cms. equilateral triangle as per design of IRC 67-2012.
Pre treated with phospheting process & acid etching;
coated with one coat of epoxy primer and two coats of
best quality epoxy paint; reflectorised with retro
refiectivesheeting as per latest M.O.S.T. Specifications;
3.1 m long stand post and frame fabricated from suitable
size iron angle of 35 x 35 x3 mm, 75 x 75 x 6 mm as
required; painted with best quality epoxy coatings in black
and white bends. The details of symbol for each board
shall be as per the instruction of engineer in charge. The
fixing as site shall be in 1:2:4 CC block of size 45 x45 x
60 Cms. for each leg.including excavation, curing etc.
complete under the supervision of engineer in charge. (A)
Class-C Type-11 Retro Reflective sheeting
45 Informatory Signs :- Providing and fixing sign boards Nos. 2 5906.48
made out of 2 mm aluminium sheet; size 80 x 60 cms.
rectangle as per design of IRC 67-2012. Pre treated with
phospheting process & acid etching; coated with one coat
of epoxy primer and two coats of best quality epoxy paint;
reflectorised with retro refiective sheeting as per latest
M.O.S.T. Specifications; 3.1 m long stand post and frame
fabricated from suitable size iron angle of 35 x 35 x 3 mm,
75 x 75 x 6 mm as required; painted with best quality
epoxy coatings in black and white bends. The details of
symbol for each board shall be as per the instruction of
engineer in charge. The fixing at site shall be in 1:2:4 CC
block of size 45 x 45 x 60 Cms. for each leg.including
excavation, curing etc. complete under the supervision of
engineer in charge. (A) Class-C Type-11 Retro Reflective
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
46 Painting Two Coats on New Concrete Surfaces Sqm. 75 90.00
(Providing and applying Synthetic Enamel Paint
Alternate Black & Yellow on crash barrier and Kerb
with one coat of white primer of cement paint and two
or more coat of paint including cleaning all dust, dirt
and other foreign matters with all material labour
equipments with all leads and lifts etc. complete.) - For
inner face of crash barrier
47 Road marking with hot applied thermoplastic paints with Sqm. 15 367.72
reflectorising glass beads on bitumin surface providing
and laying a hot applied thermoplastic compound 2.5 mm
thick including reflectorising glass beads @ 250 gms per
sqm area, thickness of 2.5 mm is excluding of surface
applied glass beads as per IRC: 35-2015. The finished
surface to be leveled, uniform and free from streaks and
holes. Zebra patta/bump patta lane/centre line/edge
line/cut patta. The white colour marking should provide
liminance coefficient on cemented road shall be 130 mcd /
m2 / lux and ashphalt roads shall be minimum 100
mcd / m2 / lux during the service life during the day time.
The marking should meet the performance criteria for
night time reflectivity, wet reflectivity and skid resistance
as mentioned in the section - 15 of IRC:35-2015.
48 Cat Eye / Road Stud / RPM: Supplying of Molded Twin Nos. 20 217.40
Shanks Raised Pavement Markers made of polycarbonate
and ABS moulded body and reflective panels with Micro
prismatic lens (No Glass bead lens) capable of providing
total internal reflection of the light entering the lens face
and shall support a load of 13635 kgs. tested in
accordance to ASTM D 4280 Type H and complying to
Specifications of Category A of MORTH Circular No
RW/NH/33023/10-97 – DO III Dt 11.06. 1997. The
height, width and length shall not exceed 20 mm, 130 mm
and 130 mm and with minimum reflective area of
Sqcm on each side and the slope to the base shall be 35 +/-
5 degree. The strength of detachment of the integrated
cylindrical shanks, (of diameter not less than 19 +/- 2 mm
and height not less than 30+/- 2 mm) from the body is to
be a minimum value of 500 Kgf. Fixing will be by drilling
holes on the road for the shanks to go inside, without nails
and using epoxy resin based adhesive as per
manufacturer’s recommendation and The color of the
marker should be as per the IRC 35-2015 and as directed
by Engineer-in-charge.
49 Providing and laying Double Walled corrugated Pipes Rmt 120 72.72
(DWC) of Polyethylene (conforming to IS:14930-II) of
50mm O.D. / 38mm I.D. with fittings and necessary
connecting accessories of same material at required
depth for laying cable below footpath slab etc.
complete as per specification and as directed by
50 Providing and fixing MS Anchor Plates of size 250 x Nos 4 1232.20
250 x 6 mm thick along with 4 Nos. of 20 mm dia.,
mm lone GI "J" Type bolts with suitable size of GI
Nuts/washer with one coat of Red Oxide and two coats
of Bituminous Black Paint and fixing on Crash Barrier
/ Parapet including necessary erection, labour,
equipments, welding / drilling, grouting / fixing of
plates as per specifications and as directed by Engineer.
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
51 Providing and laying Mineral Water proofing Sqm 245 630.00
Membrane 4mm - SUPER SHIELD BRIDGE
PROTEK (App Membrane for bridge decks polyester
and FG reinfoeced ), Include water-based primer
(SUPER PRIMER) Including Gas Torching,
overlapping of membrane for complete scope of work
including all requisite material,consumables and
52 Providing and fixing of 4 mm thk ACP Takti or SS Nos 2 400000.00
Takti including pylons, one at each corner of each of
the bridge of approved architectural design with
pedestals with minimum Size of 4' x 3' on
RCC/Decorative pylons or directed by client along with
Water Proof Mandap of minimum Size 100'x100',
Nos of VIP Chairs, 15 Nos of VIP Sofa including
necessary electric fixtures like fan,cooler,lighting
arrangement, D.G Sets etc as per site requirement and
required to make it functional or as directed by
Engineer In charge for Functions of Khat Muhurt and
Lokarpan Vidhi/Vidhies of above work.
53 Providing Supplying & Fixing Jumbo swiss type traffic Nos 2 4141.00
bollard made out of 1.5mm thick CRC sheet in conical
shape having 188cms, bottom dia 30cms, top dia
22cms, with top circular direction plate of 30cms dia
for arrow fabricated as per attached drawing and coated
with black epoxy powder coating and Retro reflector is
edthree yellow strip 15cms wide and arrow Micro
Prismatic grade sheeting as per ASTM 4956-09 Type-
XI Fixing with cement concrete M-25 grade,
Foundation size 30cm*30cm*35cm as per the
instruction of Engineer in charge.
54 Providing and fixing retro Reflective Hi Intensity Sqm 20 3249.17
Micro Prismatic Grade Board using 2mm Aluminum /
4mm ACP, angle iron 75 x 75 x 6mm. Descaling and
degreasing the board as per requirement using epoxy
reflactive process by screen painting as directed etc.
complete including transporting and fixing in C.C.
1:2:4 with necessary excavation curing etc. complete as
per I.R.C. 67-2012 design. A warranty for 7 years for
the Retro reflective sheeting from original
manufacturer & a certified copy of 3 year outdoor
exposure test report from third party test lab for the
product offered shall be submitted by contractor. (A)
Class -C Type-11(NH/SH) retro reflective sheeting
Electrical Portion
55 SETC of Conical Pole | 8 m Long, 3 mm thickness Nos. 4 14690.00
56 SETC of Bracket | single arm 2.0 m for main carraige Nos. 4 1586.00
57 Cable end termination for 4 x 16 sq mm (Single Cable) Nos. 8 180.00
58 SETC of 1.1 kV grade XLPE insulated Al conductor Mtr. 100 168.00
armoured cable | 4 x 16 sq mm
59 Laying of cable with excavation of trench having depth Mtr. 50 160.00
of 75 cms and refilling with clay and covering with
mm Ø ID DWC pipe to be laid in | Soft soil/ Kachcha
Surat Municipal Corporation
[Bridge Department]
Item Item Description Unit Qty. Rate in Rs. Amount
60 Laying of cable with excavation of trench having depth Mtr. 50 190.00
of 75 cms and refilling with clay and covering with
mm Ø ID DWC pipe to be laid in | Hard Murrum/
61 Supply & erection 50 mm Ø ID DWC pipe to be laid Mtr. 100 120.00
on wall with necessary clamps
62 8 SWG G.I. Wire Kg. 30 90.00
63 Supply & erecting PVC/ XLPE insulated ISI marked Mtr. 50 62.00
unarmoured copper cable 1.1 kV grade | 3 x 1.5 sq mm
64 1/ 2 A SP MCB Nos. 4 160.00
65 S.E.T.C. of LED Streetlight Luminaires complete with Nos. 4 12810.00
all accessories for carraige way having width of
m (Side/center/Service road Arrangement) ≈ 210 W
66 SETC of CCMS with GI Box {Capacity 9 kW, 3 Ø} & Nos. 1 62900.00
67 Pipe type Earthing having 150 cms long and 2.5 cms. Ø Nos. 2 990.00
GI pipe with coupling and buch buried in specially
prepared earth pit complete with necessary 25 x 3 mm
size GI earthing strip using salt and charcoal/ coke as
required for pipe type earthing
Grand Total Rs.
Grand Total Rs.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01_TECHNICAL BID VOL-I.pdf
02_TECHNICAL SPECIFICATION VOL-II.pdf
03_PRICE BID VOL-III.pdf
04_GAD_CANAL BRIDGE_DADA BHAGWAN (2).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .