Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 and awarded | |
| 2 | L2₹6.7 L+₹36,295 (5.71%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹6.9 L+₹58,215 (9.17%)Rejected-Finance 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹7.5 L+₹1.2 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹7.6 L+₹1.3 L (19.9%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
18 Dec 2023, 6:00 pmClosed
AGE (I) R and D Haldwani
AGE (I) R and D Haldwani PO Arjunpur UK 263139
REPAIR AND REPLACEMENT OF EXTERNAL WATER SUPPLY PIPE LINE, VALVES, PUMPS, MOTORS, STARTERS, FIRE FIGHTING EQUIPMENTS, DAY TO DAY COMPLAINTS AND OTHER MISC E/M WORKS AT DIBER HALDWANI
2023_MES_628926_2
AGE (I)/RnD/HLD-51 OF 2023-2024
Open Tender
Civil Works
Item Rate
210 days
DIBER Haldwani
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) R and D Haldwani
₹17,000
Yes
12 Feb 2024
20 Nov 2023
20 Dec 2023
20 Nov 2023
18 Dec 2023
4 Dec 2023
Amount
Contract Details
M&L for lifting out and removing non functional submersible pump set of any description and capacity (5 HP to 7.5 HP) & in any position, alongwith existing column pipe 50mm dia and existing submersible cable of any size from existing bore well (approximately 150 Mtr depth of pump set from GL)after disconnecting the electrical connection from panel, dismantling existing CI bend from non return valve and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed . NOTE 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Number of column pipe may vary from 30 to 50, The existing pipes , screwed and socket joints shall be checked for its serviceability & unserviceable joints alongwith flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new socket and nuts bolts. The cost of same shall be deemed to be included in the quoted rate for above item. However replacement of pipes if any required shall be measured & paid separately.
M&L in replacement of existing U/S MS water tubing as in column pipe, 50mm bore, medium grade of thickness 4.5 mm, ISI marked, conforming to relevant IS for column pipe in required length but length not more than 3.00 mtr, both end threaded. One end internally and other end externally threaded and duly welded with pipe using 4 Nos MS strips of size 20x 3mm in triangular right angled shape with provision of 04 Nos holes and side slot for passing submersible cable on threaded end, including painting with two coats of anti corrosive bituminous paint over a coat of red oxide primer complete all as specified and directed.
Taking out & removing old burnt out windings wire of the submersible electric motors of 5 to 7.5 HP, Three phase, 415 Volts, 50 Hz, AC supply capacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor wire including cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site complete all as specified and directed Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
Supply only Gun metal bush
Supply only Thurst plate
Supply only Shaft Grinding and polishing
Dismantalling of submersible pumpset of capacity 5 to 7.5 HP cleaning and inspection of parts removal all defective parts & replacement of defective impellers, bushes, shaft, locking pin and non return valve,rematling and repairing of repairable item reassembling testing and commissioning all as directed by eng in charge.Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under this item saperately as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
Supply only Impeller
Supply only Difuser
Supply only Gunmetal bushes
Supply only Coupler for motor and pump
Supply only Non return valve
Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well alongwith column pipe 50 mm dia and submersible cable of any size (approximately 150 Mtr depth of pump set from GL) including making necessary electric connections and providing water tight cable joint & testing the pump set after lowering complete all as specified and directed (including notes mentioned here in below). NOTES :- 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lowering of pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes with MS internally threaded flange welded with column pipe by using 04 Nos 20x3mm MS strips and thereafter jointed with rubber gasket joints and nuts, bolts / pump set at the end / submersible cable and making necessary connections and testing including reconnecting water supply system. The required materials like column pipe /flanges with rubber gasket joints/ submersible cable/ repaired pump sets etc shall be met out with old retrieved materials and additional quantity of column pipe, flanges with rubber gasket joints , submersible cable & straight through joint of cable shall be measured and paid for separately under respective item of this Schedule as “Supply only”, but the rate for its fixing shall be deemed to be included under this item.
Supply and connecting of 4 Sqmm, 3 Core, flat submersible Cable, PVC insulated, PVC sheathed with multi-stranded copper conductors, conforming to IS : 694- 1990 of 1100 Volt grade, dismantled/fixed under Sch ‘A’ item No. 1 here in above complete all as specified and directed .
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil all as dircted
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point
Supply and laying common burnt clay building bricks sub class "B" designation 75 old size bricks for cable protection
Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directed by Engr-in-Charge at site Note : - Only punned thickness shall be measured for payment purpose
Disconnecting and taking up or down old existing GI tubing and connections 20 mm bore, including connected fittings/accessories and fixtures of any description/ grade and in any position in trenches/under floors/road / on walls etc and making good the disturbed surface complete all as specified and directed
Ditto but of size 25 mm bore
Ditto but of size 40 mm bore
Ditto but of size 50 mm bore
Supply, fixing, laying, jointing & testing 20 mm bore of galvanised iron water tubing 'medium grade' conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete all as specified and directed
Ditto but of size 25 mm bore
Ditto but of size 40 mm bore
Ditto but of size 50 mm bore
Refixing old steel tubbing 20 mm bore and connection in new or old position in (trenches,wall, ceilling, floor,road etc) complete all as specified and directed
Ditto but of size 25 mm bore
Ditto but of size 40 mm bore
Ditto but of size 50 mm bore
M&L for cement concrete type D2 1:4:8 using 40 mm graded aggregate for making good surfaces in road cutting, pole foundation, stay concrete etc all as directed
M&L for cutting out concrete blocks, slabs, brick work or stone masonary(in alternative course) Road pavement, forming, toothings for and bonding new work in mortar into old work, including new materials entering old wall set in cement mortor 1:6 with pre cast cement concrete type B1, 1:2:4 (20 mm graded aggregate) all as directed and specified.
Disconneting the water supply to existing over head tank of capacity 500 ltr , washing , cleaning and removing scales, silt or dirt from the tank and refixing the same in position including washing internal surface of tank with the help of bleaching powder etc complete all as specified and directed
Disconneting the water supply to existing over head tank of capacity 1000 ltr , washing , cleaning and removing scales, silt or dirt from the tank and refixing the same in position including washing internal surface of tank with the help of bleaching powder etc complete all as specified and directed
S&F in repair PVC water tank cover for PVC water tank capacity not exc 1000 ltr including complete fittings all as directed .Make- Syntex/Polywell/Prayag
S&F in repair PVC water tank cover for PVC water tank capacity not exc 500 ltr including complete fittings all as directed .Make- Syntex/Polywell/Prayag
S&F in repair rotational moulded polythene water storage tank ( Cylindrical vertical with closed top) hoisted and in fixed in position 500 ltrs capacity including complete fittings all as directed. Make- Syntex/Polywell/Pryag
S&F in repair rotational moulded polythene water storage tank ( Cylindrical vertical with closed top) hoisted and in fixed in position 1000 ltrs capacity including complete fittings all as directed Make- Syntex/Polywell/Pryag
M&L for servicing/overhauling/repairing of existing defective centrifugal pump of following capacity 60 HP,3 Phase,415 volts, AC supply and cleaning, oiling/greasing, fixing of serviceable parts in position, oiling/greasing,refixing of serviceable parts in position,balancing, realignment etcreplcement of nut bolt washer where required, welding braging and trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete all as specified and directed. Booster/centrifugal pump of capacity 60 HP (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
Booster/centrifugal pump of capacity 25 HP,
Booster/centrifugal pump of capacity 7.5HP,
Booster/centrifugal pump of capacity 4 to 5 HP,
Booster/centrifugal/monoblock pump of capacity 2 to 3 HP,
Booster/centrifugal/Monoblock pump of capacity 1 HP,
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of 5 to 7.5 HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of 3 to 4 HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of 1 to 2 HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
Supply only ball bearing No 6308 suitable for pump set of capacity 1 HP
Supply only ball bearing No 6308 suitable for pump set of capacity 2 to 3 HP
Supply only ball bearing No 6308 suitable for pump set of capacity 4 to 5 HP
Supply only ball bearing No 6308 suitable for pump set of capacity 7.5 HP
Supply only ball bearing No 6308 suitable for pump set of capacity 25 HP
Supply only ball bearing No 6308 suitable for pump set of capacity 60 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 1 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 2 to 3 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 4 to 5 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 7.5 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 25 HP
Supply only ball bearing No 6208 suitable for pump set of capacity 60 HP
Supply only gun metal bush suitable for pump set of capacity upto 3 HP
Supply only gun metal bush suitable for pump set of capacity 4 to 7.5 HP
Supply only gun metal bush suitable for pump set of capacity 25 HP
Supply only gun metal bush suitable for pump set of capacity 60 HP
Supply only CI Impeller suitable for pump set of capacity upto 3 HP
Supply only CI Impeller suitable for pump set of capacity upto 4 to 7.5 HP
Supply only CI Impeller suitable for pump set of capacity upto 25 HP
Supply only CI Impeller suitable for pump set of capacity upto 60 HP
Supply only cooling fan blade suitable for pump set of capacity upto 3 HP
Supply only cooling fan blade suitable for pump set of capacity upto 4 to 7.5 HP
Supply only cooling fan blade suitable for pump set of capacity upto 25 HP
Supply only cooling fan blade suitable for pump set of capacity upto 60 HP
Supply only bleaching powder in 25 Kgs bag having 35 % chlorine content of E-in-C branch approved make. Chlorine liquid.
M&L for Cleaning of UG sump of residential area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 30000 ltr located at domestic area. All as directed and approved by Engineer-in-Charge
M&L for Cleaning of UG sump of Adm block area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 20000 ltr located at domestic area. All as directed and approved by Engineer-in-Charge
M&L for Cleaning of RCC tank of techanicall Bldg and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 20000 ltr located at Technical area. All as directed and approved by Engineer-in-Charge
M&L for Cleaning of UG sump of techanicall area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 75000 ltr in two component, located at Technical area. All as directed and approved by Engineer-in-Charge
M&L for Cleaning of UG sump of Bio complex area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 75000 ltr in two component and 25000 ltr in one component located at Technical area. All as directed and approved by Engineer-in-Charge
M&L for repair and removal of leakage in the main pipe line by any means like rethreading replacement of socket, union, inserting nipple etc including earth work as required to complete the job for pipe size of 20 to 25 mm bore
M&L for repair and removal of leakage in the main pipe line by any means like rethreading replacement of socket, union, inserting nipple etc including earth work as required to complete the job for pipe size of 32 to 50 mm bore
S&F in repair CI non return valve vertical type suitable for 80 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store.
S&F in repair CI non return valve vertical type suitable for 150 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store.
S&F flexible rubber coupling of delivery vertcal pipe line of out let of pump set of size 80 mm bore with nut bolt washer etc after diisconnecting and taking out old existing coupling with old nut bolt and washer etc, complete all as directed.
S&F flexible rubber coupling of delivery vertcal pipe line of out let of pump set of size 150 mm bore with nut bolt washer etc after diisconnecting and taking out old existing coupling with old nut bolt and washer etc, complete all as directed.
S&F Brass/GM foot valve vertical type suitable for 40 mm bore pipe line including threading to pipe and connecting all as directed including taking out existing one and shifting to store Make leader or equivallent.
Inspection, tuning, callibration,connecting of cable, rewiring where required from control panel to control switches and other equipment of auto functional system ,detection of fault and rectification, commisioning of main controle panel to make auto functional and testing of complete fire fighting system. Assement of serviceability of all connected equipement of fire fighting system compraising of pump set,motor,pressure tank ,pressure guage ,pressure valve electric controle panel,cable, fire hydrant,hose reel box, vertical duct, controle valves , hoses, rubber reels, syren and measurig equepements to the satisfaction of Eng- in- Charge at DIBER technical area . Minor item like cable upto 1.5 mtr, insulation tape ,marker , lugs ,separater if required will be supply and fixed by contractor, cost of the same is deemed to be included in the item of work.Notes : (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` here in after.(ii) Detail inspection/serviciability report will be submitted by the contractor cost of the same is deemed to be included in the item of work all as directed to the satisfaction of E in Charge.
M&L for repair of old existing out door double door hose box doors, locking system and replacement of both existing broken door glasses with existing size complete with rubber beading and denting/welding including painting with two coat of fire red colour enmel paint all as required at site and directed.
M&L for repair of old existing double door duct doors, locking system, hinges and replacement of both door glasses of existing size complete with rubber beading and denting/welding including painting with two coat of fire red colour enmel paint all as directed to the satisfaction of E- in -Charge
M&L fire hose box made out of MS sheet having thickness 18 gauge, double door, out door with glass pane, with locking arrengement of size L X W x D (800mm x 600mm x 250mm) fixed on two GI angle iron legs of existing size, duly painted with two coats sythatic enamelled red paint over a coat of red oxide primer and in side with white colour, including PCC foundation suitable for placing two nos of hose reel of size 15 mtr long and nozzel complete,including dismaintling of old existing one complete all as directed.
Disconnecting and taking out old existing unserviceable pressure switches supply & fix new Industrial Pressure switch universal type of exesting size complete all as directed.
Disconnecting and taking out old existing unserviceable pressure switches supply & fix Pressure gauge 4" dia, 0- 14 Kgs rating gauage of exesting size complete all as directed.
Disconnecting and taking out old existing unserviceable safety relief vave of size 25 mm straight type screwed male end of brass/bronze made and supply & fix new safety release valve of size 25mm of brass/bronze complete with testing and as directed.
Disconnecting and taking out old existing unserviceable Amp meter and supply & fix new digital Amp meter three phase bright LED display 4 digits square type complete with nut bolt and testing and commisioning all as directed. Make Schneider Cat 300461and equivalent
Disconnecting and taking out old existing unserviceable volt meter supply & fix new anolog volt meter three phase bright 0 to 500 V, square type complete with nut bolt and testing and commisioning all as directed. Make AE and equvalent
Taking out existing defective CI butterfly valve of size 80 mm bore and supply & fix new CI butterfly valves of 80 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.
Taking out existing defective CI butterfly valve of size 100 mm bore and supply & fix new CI butterfly valves of 100 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.
Taking out existing defective GM gate valve of size 20 mm bore and supply & fix new GM gate valve of size 20 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective GM gate valve of size 25 mm bore and supply & fix new GM brass gate valve of size 25 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective GM gate valve of size 40 mm bore and supply & fix new GM gate valve of size 40 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective GM gate valve of size 50 mm bore and supply & fix new GM gate valve of size 50 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective stand post hydrants landing valves single control of size 63/65 mm bore and supply & fix new fire hydrant landing valves single control of size 63/ 65 mm bore incl replacement of rubber gasket,etc. all as directed.
Taking out existing defective hose reel drum of 30 mtr length ISI marked complete with nozzle and coupling and supply & fix new hose reel drum of 30 mtr length ISI marked complete incl nozzle and coupling all as specified and as directed.
Taking out existing defective RRL hose type-A 15mtr in length, complete with nozzle and coupling supply & fix new RRL hose type-A 15mtr length ISI marked complete incl brass/ GM nozzle,male and femail coupling and all as specified and as directed.
Taking out existing defective Contactor for starter and supply & fix new Contactor of size 3 Phase 415 V 25 Amp incl replacement of nuts and bolts etc. as required and all as directed.
Taking out existing defective overload relay supply & fix new overload relay of size 6 - 25 Amp incl replacement of nuts and bolts etc. as required and all as directed.
Taking out existing defective single phase preventor supply & fix new single phase preventor three phase incl replacement of nut and bolt etc. all as directed.
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 3, 415 V, 50 HZ, 3 phase suitable for pump set of capacity 25 HP.
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 3, 415 V, 50 HZ, 3 phase suitable for pump set of capacity upto 25 HP.
Taking out existing defective starter and supply & fix new DOL starter AC 3, 415 V, 50 HZ, 3 phase suitable for pump set of capacity upto 5 HP.
Taking out old unserviceable power contractor and supply and fix 4 pole power contractor 18A/20A AC, 3 phase rating Suitable for 7.5HP / 5.6 KW AC Motors Suitable for MK 1 Starters 110V AC 50Hz Control Voltage Coil as directed by Engr in Charge.
Supply and fix MCCB 415 volts, 3 phase, 50 Hz, 3 pole of capacity 125 Amps 16 KA including taking down old unseviceable MCCB all as directed by Engr-in-Charge. Make : L&T/Indo asian/ABB/Havells
Supply and fix MCCB 415 volts, 3 phase, 50 Hz, 3 pole of capacity 63 Amps 16 KA including taking down old unseviceable MCCB all as directed by Engr-in-Charge. Make : L&T/Indo asian/ABB/Havells
Supplying and fixing 5 to 32 A rating, Three pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 40 to 63 A rating, Three pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supply and fix in replacement power contactor 3 pole,415 volt, 50 HZ, 70 to 100 Amp capacity of Make- L&T as per sample and directed or equivallent make.
Supply and fix in replacement electronic timer 3 to 30 sec 240/415 Volt as required at site type ST 100 of MakeL&T as persample or other equivallant and as directed directed.
Supply and fix water level controller with water level controller probe for draining and filling application 240/415 Volt. Make L&T as per sample or other equivallant make and all as directed.
M&L for supply instalation, testing, commisioning of fire alarm response indicator in replacement of existing unserviceable response indicator incl Disconnecting, dismantling and taking out existing unserviceable fire remote indicator to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M&L for supply instalation, testing, commisioning of fire alarm hooter/sounder with hammer built in ABS housing / MS housing (12 volt dc) connected with main controll pannel in replacement of existing unserviceable fire alarm hooter/sounder incl disconnecting, dismantling and taking out existing unserviceable fire alarm hooter/sounder to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of fire alarm manual call point (MCP box) in replacement of existing unserviceable fire alarm manual call point incl Disconnecting, dismantling and taking out existing unserviceable fire alarm manual call point to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of smoke detector in replacement of existing unserviceable smoke detector incl Disconnecting, dismantling and taking out existing unserviceable smoke detector to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M&L for collecting out water sample from bore well tank and giving it to the govt approved lab for chemical/micro biological testing like colour, turbidity, PH, TDS, Hardness, Alkalinity etc and then taking it from lab and giving it to the AGE Office for further submission all as specified and as directed.
Disconnecting and taking out old existing unserviceable LT UG cable of size 10 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 10 square mm, 4 core complete all as specified and directed. Make- Havells/Plaza/Universal/KEI/Polycab/MESCAB
Disconnecting and taking out old existing unserviceable LT UG cable of size 16 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 16 sqmm, 4 core . complete all as specified and directed. Make- Havells/Plaza/Universal/KEI/Polycab/MESCAB
Disconnecting and taking out old existing unserviceable LT UG cable of size 25 Sqmm 3.5 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 25 sqmm, 3.5 core . complete all as specified and directed. Make- Havells/Plaza/Universal/KEI/Polycab/MESCAB
Providing and fixing earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc.as required.
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out old unserviceable float vales.
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 including
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
JAGAT POWER ELCTRICAL
om enterprises
Gurcharan Singh Enterprises
M/S BHATT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .