Executive_Engineer_NTKMD_PHED
Utility_Bldg__Beside_Delhi_Public_School_AA_ID_New_Town_Kol_700156
Electrical and Mechanical repairing works at different tube well sites in AA-III at New Town under NTK Project.
2026_PHED_1025530_8
PHE/NTKMD/e-01 of 2026-27
Open Tender
Project Work
Percentage
30 days
WORK
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
7 Sept 2026
28 May 2026
22 Jun 2026
28 May 2026
20 Jun 2026
28 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1OHR-19 Withdrawing of the existing damaged 15 HP submersible pump set from the tube well of OHR-19 with the help of derrick arrangement after checking thoroughly and dismantling of delivery line & disconnection of electrical connections. | |||||
| 2.01 | Supply and delivery of followings at site :-
Submersible Pumping Machinery directly coupled with water proof suitable size motor having following specification :
Pump
Head : 52 m., Discharge : 54 m³/hr
Shaft : SS ; Outlet Size : 80 mm/ 100 mm; Impeller : Chrome Steel/ SS
Pump Efficiency : Minimum 65%
Motor
Capacity : 11 kW/ 15 HP, Type: 3 Phase Submersible, 415V ± 10% AC, , 50 Hz wet type winding, RPM : 2900
[Make : KSB/ Pluga / Approved make]
N.B. :
i) H-Q Characteristic Curve of Pump set should be sumitted before delivery.
ii) Warranty & Test Certificate of P/M set should be sumitted during delivery. | - | NO. | - | - |
| 2.02 | 100 mm dia CI Bottom Adaptor | - | NO. | - | - |
| 2.03 | 100 mm dia GI Socket | - | NO. | - | - |
| 2.04 | Anti snapping safety device for pump set having suitable size M.S. fabricated cage, clamp & 20 mm dia. nylon rope of required length incluiding supplying nuts, bolts & others materials. | - | ITEM | - | - |
| 2.05 | Gasket sets | - | ITEM | - | - |
| 2.06 | Nuts & Bolts with washers | - | ITEM | - | - |
| 2.07 | 250A Power Terminal as per sample | - | NO. | - | - |
| 2.08 | 150A Power Terminal as per sample | - | NO. | - | - |
| 3Installation of above supplied submersible pump set along with above supplied materials (2.01 - 2.06) to the said T.W including making connection of delivery line & electrical connection including test run all complete. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
Tendernotice_2.pdf
PDF • 0.90 MB
Tendernotice_3.pdf
PDF • 0.55 MB
Tendernotice_4.pdf
PDF • 0.04 MB
BOQ_2520033.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .