| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1electrical | ||||||
| 1.001 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | - | point | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | - | point | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required. | - | each | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | OD517082/2025-2026:Supply and providing 5/7 Watts LED lamp on existing batten/ pendent/ bracket holder as required | - | no | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | OD517093/2025-2026:Supply and providing 18 W, LED out door bulk head fittings on wall/ceiling and giving connections with required length of 16/0.20 mm PVC insulated and sheathed 3 core round copper conductor flex wire etc as required. (LUKER eco LBKOVSL18 or equivalent make). | - | no | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm | - | metre | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door | - | each | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 amps | - | each | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | - | each | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Preliminaryagreement.pdf
Tender Documents • 0.07 MB
BOQ_1443490.xls
BOQ • 0.32 MB
epaymentnew.pdf
Other Document • 0.04 MB
FOT.pdf
Other Document • 0.05 MB
IPACT.pdf
Other Document • 0.03 MB
Affidavit.pdf
Other Document • 0.05 MB
viewsbdmerged.pdf
Other Document • 1.66 MB
Download all tender documents and submit your bid