Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹43.1 L+₹4.3 L (11.0%)Rejected-Finance | L2 | Rejected-Finance other than lowest tenderer | |
| 3 | L3₹4.6 L−₹34.3 L (88.2%)Rejected-Finance | L3 | Rejected-Finance other than lowest tenderer | |
| 4 | L3₹45.8 L+₹6.9 L (17.8%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L3 | Rejected-Finance other than lowest tenderer | |
| 5 | L5₹59.2 L+₹20.3 L (52.3%)Rejected-Finance ABM HOUSE CHEMBUMUKKU THRIKAKKARA P O KOCHI 682021 | KOCHI | ERNAKULAM | KERALA | 682021 | L5 | Rejected-Finance other than lowest tenderer |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
22 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
CERTAIN SANCTIONED WORKS AT NAVAL BASE KOCHI
2022_MES_510322_1
8873/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹92,000
Yes
6 May 2022
24 Feb 2022
24 Mar 2022
24 Feb 2022
22 Mar 2022
8 Mar 2022
24 Feb 2022 - 7 Mar 2022
60 days
Amount
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 300 sqmm with suitable cable gland including taking down of unserviceable Cable complete all as specified and directed.
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 185 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 150 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 120 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 95 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 50 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 35 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 4 core 10 Sqmm
Supply, installation, Testing and Commissioning of 9M GI Octagonal pole single section with bottom dia 155mm, top dia 70mm having sheet thickness 3mm. The door height cutout should not be more than 500mm with door elevation 500mm. The size of the reinforced rod should be 30x4mm. Size of the base plate should be 250 x 250 x 16mm with thickness of base plate 16mm(Minimum). PCD for the holes should be 260mm with foundation bolt dia M24, length of the foundation bolt 750mm with four foundation bolts .Pole should have arm to mount Single Flood light with 15-degree Arm bracket and the total height of the pole should be 9000 mm above the finished Ground level including PCC foundation, J Bolt, nuts and washers as per the drawing of Manufacturer's instructions complete all as specified and as directed.
Supply and fix 90 Watt LED Street light with pressure dia cast Aluminium housing and toughened glass with high power LED, Efficiency should be more than 110 lumen/watt, The luminaries should be of IP-66 Protection and should have 10KV external surge protection and 4KV Internal surge protection complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation of pole and laying of underground electric cable in soft/loose soil complete all specified and directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all specified and directed.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all specified and directed.
Supply and spread River Sand for cushioning and covering of UG cables in trenches complete all specified and directed. (Note : For measurement purpose only punned thickness shall be measured and paid)
Supply and laying un-reinforced precast concrete cable cover class LV type-I flat size 250mm x 150mm x 40mm complete all specified and directed.
Material and Labour for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 metre below normal ground level, connected to galvanised iron wire 4mm as earthing lead by means of bolts, nuts, washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point including excavation and earth work, PCC chamber, RCC chamber cover, watering pipe, funnel etc including testing on completion.
Supply and fixing isolator TPN 415V, 50Hz of capacity 32A complete all directed.
Material & Labour wiring along with earth wire 2 x 4Sqmm + 1 x 4 Sqmm PVC insulated copper conductor single core cable in PVC conduit for connecting street light from isolator complete all directed.
Supply and fixing streetlight timer panel 3 phase, 415V, 50Hz digital 24hours with contactor 32A TP with all accessories complete all directed.
Dismantling of concrete pole any size complete all directed by Engineer in charge.
Dismantling/ taking down streetlight fitting of any size complete all directed by Engineer in charge.
Dismantling and removing UG cable of any size complete all directed by Engineer in charge.
Supply and fixing GI pipe light grade with necessary fittings in floor /pillar/fixed on pole of size 40 mm dia complete all as specified
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 150 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Material & Labour for straight through joint 3.5 core 185 to 240 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 95 to 120 Sqmm with all accessories complete all specified and directed.
Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm X 40mm X 6mm thick frame work and CRCA sheet 3 mm thick having Aluminum bus bar of rating 600 Amps,three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mm X 750mmX 500mm, mounted on angle iron stand made out of size 40mm X 40mm X 6mm grouted of digital volt meter & Amps meter with CTs including taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 600 Amps aluminium strip - 1 Set (b) MCCB 400 Amp 35 KA 4 pole - 01 No ( Incoming) (c) MCCB 160 Amp 35 KA 4 pole - 01 No (Outgoing) (d) MCCB100 Amp 25 KA 4 pole - 03 Nos(Outgoing) (e) MCCB 63 Amp 25 KA 4 pole - 03 Nos(Outgoing) (f) Volt meter digital 0-500 volt -01 (g) Amp meter digital 0-300 Amp - 01 (h) Indicator lamp Yellow, Red, Blue - 01 Set
Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply sysytem conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm X 40mm X 6mm thick frame work and CRCA sheet 3 mm thick having Aluminum bus bar of rating 800 Amps,three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mm X 750mmX 500mm, mounted on angle iron stand made out of size 40mm X 40mm X 6mm grouted of digital volt meter & Amps meter with CTs including taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 800 Amps aluminium strip - 1 Set (b) MCCB 630 Amp 35 KA 4 pole - 01 No ( Incoming) (c) MCCB 400 Amp 35 KA 4 pole - 01 No (Outgoing) (d) MCCB 250 Amp 25 KA 4 pole - 02 Nos(Outgoing) (e) MCCB 200 Amp 25 KA 4 pole - 02 Nos(Outgoing) (f) Volt meter digital 0-500 volt - 01 Nos (g) Amp meter digital 0-300 Amp - 01 Nos (h) Indicator lamp Yellow, Red, Blue - 01 Set
Material & Labour for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of earth plate not less than 1.5 metre below the ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80mm thick RCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR part -I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/ transformer neutral/body/ LT panel etc. and testing on completion, complete all as specified & directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 metre wide and 1.5 metre deep in Hard and dense soil complete all as directed
Material & Labour for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base/foundation/making good to road/path cutting etc complete all as specified.
Material & Labour for Precast cement concrete solid block type B1 1:2:4 (using 20mm graded stone aggregate) exceeding 10cm in width and setting in cement mortar 1:6 complete all as specified.
Supply & Fix Roof trusses (framed), trussed, purlin, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, of grade Fe 410-W(Gde-E-250) Quality-A complete all as specified and as directed
Supply & Fix Steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St- 240 complete all as specified and directed.
Material & Labour for preparation of new plastered surfaces of wall and apply of two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified.
Material & Labour for preparation of new iron and steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Supply & Fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, with grade of zink coating 275 of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Supply & Fix in repair PVC (SWR) pipes 110mm Dia Single socketed in any length with rubber ring joints fixed to walls complete all as specified.
Supply & Fix in repair PVC Eves Gutter heavy duty half round 200mm dia including drop end with all necessary Flat Iron fitting complete all as specified.
Supply & Fix in repair PVC (SWR) Bend 110 mm Dia complete all as specified.
Material & Labour for Moorum/red bajri filling in floors or paving, laid in layers not exceeding 15 cm thick, spread, leveled and rammed including watering complete all as specified.
Material & Labour for Machine cut Kota stone slab flooring 20-25mm thick, screed bed or bedding layer of cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc, complete all as specified and all as directed.
Material & Labour for 100 mm thick P.C.C 1:4:8 type B-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and as directed
Material & Labour for 75 mm thick P.C.C 1:4:8 type B-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and as directed
Material & Labour for 25 mm thick PCC 1:2:4 type B1, 20 mm graded stone aggregate as in flooring including finishing cement concrete rough surface without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
P N Enterprises
M/s.Rejoy Constructions
Super Constructions
ABM ELECTRICALS
Saket Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .