Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 CrAccepted-AOC NOT SPECIFIED | L1 | Accepted-AOC L1 Bidder, Agreement Executed | |
| 2 | L2₹30.0 Cr+₹1.5 Cr (5.25%)Rejected-Finance | L2 | Rejected-Finance L2 bidder, Could not satisfy the experience criteria in NIT vol I and II | |
| 3 | Rejected-Technical | - | Rejected-Technical PQ Disqualified | |
| 4 | Rejected-Technical | - | Rejected-Technical PQ Disqualified |
| Sl No | Description | Qty | Unit | Tomco Engineering (P) Ltd. L2 | MARYMATHA INFRASTRUCTURE PVT LTD L1 |
|---|---|---|---|---|---|
| 1.00Supply and Erection of Pumpsets | |||||
| 1.00 | OD144453/2024-2025:Supply, erection, testing and commissioning of pre qualified reputed make VT pump set having a minimum discharge of 1850 m3/hr (514 lps) against a total head of 65m (minimum 70 % overall efficiency ) with suitable Vertical mounted 3.3 KV motor with all accessories such as 3.3KV FCMA type Soft Starter with panel board, cable work, connecting to pumping main etc. including the cost of earthing, power factor improvement capacitor, valves etc complete with the following specification
1. Pump- Supply, erection, testing and commissioning of KWA qualified reputed make water-lubricated VT pump set with bronze/SS impellers, SS shaft with Mild Steel (MS), Electric Resistant Welded (ERW) column pipe of suitable diameter and length. The pump set is coupled with a vertical squirrel cage induction motor. The pump set shall have a capacity of 1850 m3/hr (514 lps) discharge and 65 m head.
2. Motor-supply, erection, testing and commissioning of KWA pre-qualified reputed make, IE3 or higher vertical mounted Solid shaft TEFC squirrel cage induction motor for direct coupling with the above pump set having RPM 960 or nearest suitable for operation at 3.3 KV 3 phase 50Hz.AC supply, Class F insulation, IP55 degree of protection with all standard accessories such as sufficient number of RTDs for body temperature and bearing temperature, Space heater etc as per standards. The motor should confirm to EEFI/IS standards.
3.STARTER
Supply, erection, testing and commissioning of suitable rating FCMA Soft Starter assembly in suitable dust and vermin proof powder coated 3mm thick steel anti chemical paint coated floor mounting type panel board with the following components. A) FCMA Soft Starter unit b) Off load isolator C) Main vacuum contactor D) Bypass Vacuum contactor E) Programmable motor protection relay Micom 220 Schneider for main protection E) Additional fail-safe motor protection relay MPro 100 or equivalent F) Surge Suppressor – 3Nos G) Current transformers and potential transformers for control, protection and metering. H) Multi-function digital meters for measuring voltage, Current, Energy, KW, Frequency etc I) Panel and Unit temperature sensors and tripping relays J) Indicating lamps K) Hooter with accept button L) Anti condensation heaters M) Mechanical as well as electrical interlocking facility N) ON-OFF-Trip-Healthy LED indicators etc and control contactors and relays as per standards complete with control wiring and busbar interconnections.
4. Cabling work-Supply, laying, testing and commissioning of suitable size XLPE cables as per IS standards for the above pump set from panel board to starter and from starter to motor considering energy conservation.
6.Earthing-Supply of all material and providing suitable earthing by using Copper earthing strips of suitable rating for earthing to motor, starter, panel board etc as per CEA standards and IS and linking to main earth bus and to the earth pit provided as per IS 3043/2018
7.Capacitor-Supply, erection, testing and commissioning of heavy duty ISI marked KWA approved / from reputed manufacturers APP capacitor with Detuned Reactor for use in 3.3KV supply and to be connected to the incoming side of the motor using suitable cables, in suitable sheet steel panel with Isolator, Vacuum contactor, HT HRC fuses , Indicating lamps , Metering etc including cabling, Bus bars, Interconnections and control wiring and earthing.
8. VALVES: Supply of suitable size best quality ISI marked 500 mm size heavy duty cast iron double flanged sluice valve PN 1.6 suitable for above pump set factory fitted detachable multi turn electrical actuator having following specifications and conditions :- 415V 3Phase 50Hz S2 duty serviceable 3Phase motor ,torque switches ON/OFF indications manual override hand wheel remote start/stop facility ,integrated starter etc. Actuator should capable for operating 500 mm sluice valve at 4.8kg/cm2 line pressure and time of duration required to fully open to fully close is not greater than 15 minutes -1No. Supply of suitable size best quality, ISI marked heavy duty cast iron 500 mm size double flanged reflex Non Return Valve as per PN 1.6 suitable for above pump set -1no Supply reputed make 150 mm dia Fluid filled pressure gauge with Regulator cock and all accessories suitable for the above pump set -1set
9. ERECTION: Erection of the motor, pump set, starter panel boards, capacitor panel etc. on suitable concrete foundation with pump base plate giving power connecting cables to panel board to starters, starter to motor, capacitors, providing end termination, earthing of equipment supply fitting necessary pipes and specials to connect the delivery of pump set to the header pipe by necessary interconnection and fabrication etc. complete including taking trial run to the satisfaction of departmental officers including any other works and cost of materials required for the commissioning of the motor/ pump set as per standards including the rate for high voltage installations - 1Set | 3 | no | 1,25,00,000 ₹3,75,00,000 Lowest | 2,08,68,000 ₹6,26,04,000 |
| 1.00 | OD144454/2024-2025:Supply, erection, testing and commissioning of pre qualified reputed make VT pump
set having a minimum discharge of 2880 m3/hr (800 lps) against a total head of 21m
with suitable 3.3 KV motor with all accessories such
as starter, panel board, cable work, connecting to pumping main etc. including the
cost of earthing, capacitor, valves etc complete with the following specification
.1.Pump-Supply ,erection, testing and commissioning of KWA qualified reputed
make water-lubricated VT pump set with bronze/SS impellers, SS shaft with Mild
Steel (MS), Electric Resistant Welded (ERW) column pipe of suitable diameter and
length. The pump set is coupled with a vertical squirrel cage induction motor. The
pump set shall have a capacity of 2880 m3/hr (800 lps) discharge and 21 m head
2. Motor-supply, erection, testing and commissioning of KWA pre-qualified reputed make, IE3 or higher vertical mounted Solid shaft TEFC squirrel cage induction motor for direct coupling with the above pump set having RPM 960 or nearest suitable for operation at 3.3 KV 3 phase 50Hz.AC supply, Class F insulation, IP55 degree of protection with all standard accessories such as sufficient number of RTDs for body temperature and bearing temperature, Space heater etc as per standards. The motor should confirm to EEFI/IS standards.
3.STARTER
Supply, erection, testing and commissioning of suitable rating FCMA Soft Starter assembly in suitable dust and vermin proof powder coated 3mm thick steel anti chemical paint coated floor mounting type panel board with the following components for the above motor. A) FCMA Soft Starter unit b) Off load isolator C) Main vacuum contactor D) Bypass Vacuum contactor E) Programmable motor protection relay Micom 220 Schneider for main protection E) Additional fail-safe motor protection relay MPro 100 or equivalent F) Surge Suppressor – 3Nos G) Current transformers and potential transformers for control, protection and metering. H) Multi-function digital meters for measuring voltage, Current, Energy, KW, Frequency etc I) Panel and Unit temperature sensors and tripping relays J) Indicating lamps K) Hooter with accept button L) Anti condensation heaters M) Mechanical as well as electrical interlocking facility N) ON-OFF-Trip-Healthy LED indicators etc and control contactors and relays as per standards complete with control wiring and busbar interconnections.
4. Cabling work-Supply, laying, testing and commissioning of suitable size XLPE cables as per IS standards for the above pump set from panel board to starter and from starter to motor considering energy conservation.
6.Earthing-Supply of all material and providing suitable earthing by using Copper earthing strips of suitable rating for earthing to motor, starter, panel board etc as per CEA standards and IS and linking to main earth bus and to the earth pit provided as per IS 3043/2018
7.Capacitor-Supply, erection, testing and commissioning of heavy duty ISI marked KWA approved / from reputed manufacturers APP capacitor with Detuned Reactor for use in 3.3KV supply and to be connected to the incoming side of the motor using suitable cables, in suitable sheet steel panel with Isolator, Vacuum contactor, HT HRC fuses , Indicating lamps , Metering etc including cabling, Bus bars, Interconnections and control wiring and earthing.
8. VALVES: Supply of suitable size best quality ISI marked 500 mm size heavy duty cast iron double flanged sluice valve PN 1.6 suitable for above pump set factory fitted detachable multi turn electrical actuator having following specifications and conditions :- 415V 3Phase 50Hz S2 duty serviceable 3Phase motor ,torque switches ON/OFF indications manual override hand wheel remote start/stop facility ,integrated starter etc. Actuator should capable for operating 500 mm sluice valve at 4.8kg/cm2 line pressure and time of duration required to fully open to fully close is not greater than 15 minutes -1No. Supply of suitable size best quality, ISI marked heavy duty cast iron 500 mm size double flanged reflex Non Return Valve as per PN 1.6 suitable for above pump set -1no Supply reputed make 150 mm dia Fluid filled pressure gauge with Regulator cock and all accessories suitable for the above pump set -1set
9. ERECTION: Erection of the motor, pump set, starter panel boards, capacitor panel etc. on suitable concrete foundation with pump base plate giving power connecting cables to panel board to starters, starter to motor, capacitors, providing end termination, earthing of equipment, supply and fitting necessary pipes and specials to connect the delivery of pump set to the header pipe by necessary interconnection and fabrication etc. complete including taking trial run to the satisfaction of departmental officers including any other works and cost of materials required for the commissioning of the motor/ pump set as per standards including the rate for high voltage installations - 1Set | 4 | no | 75,00,000 ₹3,00,00,000 Lowest | 1,12,80,000 ₹4,51,20,000 |
| 1.00 | OD156135/2024-2025:ON-OFF Push button station with Emergency Off button in suitable weather proof enclosure and fixing near the motor including supply laying and termination of control cable. | 7 | set | 20,00,000 ₹1,40,00,000 | 6,110 ₹42,770 Lowest |
| 1.00 | OD144808/2024-2025:Lifting and dismantling of existing VT pump sets having 405 lps discharge and 65m
head including the 3.3KV motor with solid shaft and stacking as per the direction of
department
officers. | 3 | no | 10,00,000 ₹30,00,000 | 71,440 ₹2,14,320 Lowest |
| 1.00 | OD144846/2024-2025:Lifting and dismantling of existing VT pump sets having 1876 m3/hr( 521 lps ) discharge
and19.15 m
head including the 3.3KV motor with solid shaft and stacking as per the direction of
department
officers. | 4 | no | 10,00,000 ₹40,00,000 | 79,900 ₹3,19,600 Lowest |
| 2.00HT cables upgradation Works and formation of approach road from East gate to Raw Water Pump House No.3 | |||||
| 2.00 | OD148133/2024-2025:Supplying and laying of 3 core 300sq.mm,Brand stranded circular aluminum conductor, XLPE Insulated, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC sheathed 3.3/6.6 KV cable from substation No:3 to RWPH No:2 New panel in the existing trenches, the cables are covered with bricks and sand for mechanical protection, suitable clamps are provided in the cable tray sides etc.. | 1,200 | metre | 4,000 ₹48,00,000 | 2,820 ₹33,84,000 Lowest |
| 2.00 | OD148151/2024-2025:Supplying indoor heat shrinkable cable end jointing kit with lugs for 3.3 KV XLPE cable for 3 core 300 sq.mm | 4 | no | 25,000 ₹1,00,000 | 7,520 ₹30,080 Lowest |
| 2.00 | OD148153/2024-2025:Fixing and termination of the 3 core 300 sq.mm XLPE 3.3 KV cable end kit(shrinking indoor type) | 4 | no | 25,000 ₹1,00,000 | 6,110 ₹24,440 Lowest |
Tender Value
₹24.2 Cr
EMD Value
₹5 L
Closing Date
28 Mar 2025, 3:00 pmClosed
Superintending Engineer
Kerala Water Authority, P.H Circle, Kochi-11
StatePlan2019 20InterimAugmentation ofWSS toKochiCity and Adjoining PtsUrgentmeasures at 225MLD WaterTreatmentPlantAluva forimprovingthe drinkingwatersupply to KochiCityand adjoiningareas incorporating the essentialrehabilitation wrks GeneralCivilWrk
2025_KWA_741468_1
E-Tender No 49/2024-25/SE/PHC/CHN
Open Tender
Civil Works - Water Works
Item Rate
270 days
Aluva
Please refer Tender documents.
9 documents required · 9 mandatory
₹19,518
₹5 L
Kerala Water Authority, P.H Circle, Kochi-11
12 Oct 2026
21 Feb 2025
29 Mar 2025
21 Feb 2025
28 Mar 2025
21 Feb 2025
21 Feb 2025 - 3 Mar 2025
3 Mar 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and Erection of Pumpsets | |||||
| 1.001 | OD144453/2024-2025:Supply, erection, testing and commissioning of pre qualified reputed make VT pump set having a minimum discharge of 1850 m3/hr (514 lps) against a total head of 65m (minimum 70 % overall efficiency ) with suitable Vertical mounted 3.3 KV motor with all accessories such as 3.3KV FCMA type Soft Starter with panel board, cable work, connecting to pumping main etc. including the cost of earthing, power factor improvement capacitor, valves etc complete with the following specification
1. Pump- Supply, erection, testing and commissioning of KWA qualified reputed make water-lubricated VT pump set with bronze/SS impellers, SS shaft with Mild Steel (MS), Electric Resistant Welded (ERW) column pipe of suitable diameter and length. The pump set is coupled with a vertical squirrel cage induction motor. The pump set shall have a capacity of 1850 m3/hr (514 lps) discharge and 65 m head.
2. Motor-supply, erection, testing and commissioning of KWA pre-qualified reputed make, IE3 or higher vertical mounted Solid shaft TEFC squirrel cage induction motor for direct coupling with the above pump set having RPM 960 or nearest suitable for operation at 3.3 KV 3 phase 50Hz.AC supply, Class F insulation, IP55 degree of protection with all standard accessories such as sufficient number of RTDs for body temperature and bearing temperature, Space heater etc as per standards. The motor should confirm to EEFI/IS standards.
3.STARTER
Supply, erection, testing and commissioning of suitable rating FCMA Soft Starter assembly in suitable dust and vermin proof powder coated 3mm thick steel anti chemical paint coated floor mounting type panel board with the following components. A) FCMA Soft Starter unit b) Off load isolator C) Main vacuum contactor D) Bypass Vacuum contactor E) Programmable motor protection relay Micom 220 Schneider for main protection E) Additional fail-safe motor protection relay MPro 100 or equivalent F) Surge Suppressor – 3Nos G) Current transformers and potential transformers for control, protection and metering. H) Multi-function digital meters for measuring voltage, Current, Energy, KW, Frequency etc I) Panel and Unit temperature sensors and tripping relays J) Indicating lamps K) Hooter with accept button L) Anti condensation heaters M) Mechanical as well as electrical interlocking facility N) ON-OFF-Trip-Healthy LED indicators etc and control contactors and relays as per standards complete with control wiring and busbar interconnections.
4. Cabling work-Supply, laying, testing and commissioning of suitable size XLPE cables as per IS standards for the above pump set from panel board to starter and from starter to motor considering energy conservation.
6.Earthing-Supply of all material and providing suitable earthing by using Copper earthing strips of suitable rating for earthing to motor, starter, panel board etc as per CEA standards and IS and linking to main earth bus and to the earth pit provided as per IS 3043/2018
7.Capacitor-Supply, erection, testing and commissioning of heavy duty ISI marked KWA approved / from reputed manufacturers APP capacitor with Detuned Reactor for use in 3.3KV supply and to be connected to the incoming side of the motor using suitable cables, in suitable sheet steel panel with Isolator, Vacuum contactor, HT HRC fuses , Indicating lamps , Metering etc including cabling, Bus bars, Interconnections and control wiring and earthing.
8. VALVES: Supply of suitable size best quality ISI marked 500 mm size heavy duty cast iron double flanged sluice valve PN 1.6 suitable for above pump set factory fitted detachable multi turn electrical actuator having following specifications and conditions :- 415V 3Phase 50Hz S2 duty serviceable 3Phase motor ,torque switches ON/OFF indications manual override hand wheel remote start/stop facility ,integrated starter etc. Actuator should capable for operating 500 mm sluice valve at 4.8kg/cm2 line pressure and time of duration required to fully open to fully close is not greater than 15 minutes -1No. Supply of suitable size best quality, ISI marked heavy duty cast iron 500 mm size double flanged reflex Non Return Valve as per PN 1.6 suitable for above pump set -1no Supply reputed make 150 mm dia Fluid filled pressure gauge with Regulator cock and all accessories suitable for the above pump set -1set
9. ERECTION: Erection of the motor, pump set, starter panel boards, capacitor panel etc. on suitable concrete foundation with pump base plate giving power connecting cables to panel board to starters, starter to motor, capacitors, providing end termination, earthing of equipment supply fitting necessary pipes and specials to connect the delivery of pump set to the header pipe by necessary interconnection and fabrication etc. complete including taking trial run to the satisfaction of departmental officers including any other works and cost of materials required for the commissioning of the motor/ pump set as per standards including the rate for high voltage installations - 1Set | 3 | no | - | - |
| 1.002 | OD144454/2024-2025:Supply, erection, testing and commissioning of pre qualified reputed make VT pump
set having a minimum discharge of 2880 m3/hr (800 lps) against a total head of 21m
with suitable 3.3 KV motor with all accessories such
as starter, panel board, cable work, connecting to pumping main etc. including the
cost of earthing, capacitor, valves etc complete with the following specification
.1.Pump-Supply ,erection, testing and commissioning of KWA qualified reputed
make water-lubricated VT pump set with bronze/SS impellers, SS shaft with Mild
Steel (MS), Electric Resistant Welded (ERW) column pipe of suitable diameter and
length. The pump set is coupled with a vertical squirrel cage induction motor. The
pump set shall have a capacity of 2880 m3/hr (800 lps) discharge and 21 m head
2. Motor-supply, erection, testing and commissioning of KWA pre-qualified reputed make, IE3 or higher vertical mounted Solid shaft TEFC squirrel cage induction motor for direct coupling with the above pump set having RPM 960 or nearest suitable for operation at 3.3 KV 3 phase 50Hz.AC supply, Class F insulation, IP55 degree of protection with all standard accessories such as sufficient number of RTDs for body temperature and bearing temperature, Space heater etc as per standards. The motor should confirm to EEFI/IS standards.
3.STARTER
Supply, erection, testing and commissioning of suitable rating FCMA Soft Starter assembly in suitable dust and vermin proof powder coated 3mm thick steel anti chemical paint coated floor mounting type panel board with the following components for the above motor. A) FCMA Soft Starter unit b) Off load isolator C) Main vacuum contactor D) Bypass Vacuum contactor E) Programmable motor protection relay Micom 220 Schneider for main protection E) Additional fail-safe motor protection relay MPro 100 or equivalent F) Surge Suppressor – 3Nos G) Current transformers and potential transformers for control, protection and metering. H) Multi-function digital meters for measuring voltage, Current, Energy, KW, Frequency etc I) Panel and Unit temperature sensors and tripping relays J) Indicating lamps K) Hooter with accept button L) Anti condensation heaters M) Mechanical as well as electrical interlocking facility N) ON-OFF-Trip-Healthy LED indicators etc and control contactors and relays as per standards complete with control wiring and busbar interconnections.
4. Cabling work-Supply, laying, testing and commissioning of suitable size XLPE cables as per IS standards for the above pump set from panel board to starter and from starter to motor considering energy conservation.
6.Earthing-Supply of all material and providing suitable earthing by using Copper earthing strips of suitable rating for earthing to motor, starter, panel board etc as per CEA standards and IS and linking to main earth bus and to the earth pit provided as per IS 3043/2018
7.Capacitor-Supply, erection, testing and commissioning of heavy duty ISI marked KWA approved / from reputed manufacturers APP capacitor with Detuned Reactor for use in 3.3KV supply and to be connected to the incoming side of the motor using suitable cables, in suitable sheet steel panel with Isolator, Vacuum contactor, HT HRC fuses , Indicating lamps , Metering etc including cabling, Bus bars, Interconnections and control wiring and earthing.
8. VALVES: Supply of suitable size best quality ISI marked 500 mm size heavy duty cast iron double flanged sluice valve PN 1.6 suitable for above pump set factory fitted detachable multi turn electrical actuator having following specifications and conditions :- 415V 3Phase 50Hz S2 duty serviceable 3Phase motor ,torque switches ON/OFF indications manual override hand wheel remote start/stop facility ,integrated starter etc. Actuator should capable for operating 500 mm sluice valve at 4.8kg/cm2 line pressure and time of duration required to fully open to fully close is not greater than 15 minutes -1No. Supply of suitable size best quality, ISI marked heavy duty cast iron 500 mm size double flanged reflex Non Return Valve as per PN 1.6 suitable for above pump set -1no Supply reputed make 150 mm dia Fluid filled pressure gauge with Regulator cock and all accessories suitable for the above pump set -1set
9. ERECTION: Erection of the motor, pump set, starter panel boards, capacitor panel etc. on suitable concrete foundation with pump base plate giving power connecting cables to panel board to starters, starter to motor, capacitors, providing end termination, earthing of equipment, supply and fitting necessary pipes and specials to connect the delivery of pump set to the header pipe by necessary interconnection and fabrication etc. complete including taking trial run to the satisfaction of departmental officers including any other works and cost of materials required for the commissioning of the motor/ pump set as per standards including the rate for high voltage installations - 1Set | 4 | no | - | - |
| 1.003 | OD156135/2024-2025:ON-OFF Push button station with Emergency Off button in suitable weather proof enclosure and fixing near the motor including supply laying and termination of control cable. | 7 | set | - | - |
| 1.004 | OD144808/2024-2025:Lifting and dismantling of existing VT pump sets having 405 lps discharge and 65m
head including the 3.3KV motor with solid shaft and stacking as per the direction of
department
officers. | 3 | no | - | - |
| 1.005 | OD144846/2024-2025:Lifting and dismantling of existing VT pump sets having 1876 m3/hr( 521 lps ) discharge
and19.15 m
head including the 3.3KV motor with solid shaft and stacking as per the direction of
department
officers. | 4 | no | - | - |
| 2HT cables upgradation Works and formation of approach road from East gate to Raw Water Pump House No.3 | |||||
| 2.001 | OD148133/2024-2025:Supplying and laying of 3 core 300sq.mm,Brand stranded circular aluminum conductor, XLPE Insulated, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC sheathed 3.3/6.6 KV cable from substation No:3 to RWPH No:2 New panel in the existing trenches, the cables are covered with bricks and sand for mechanical protection, suitable clamps are provided in the cable tray sides etc.. | 1,200 | metre | - | - |
| 2.002 | OD148151/2024-2025:Supplying indoor heat shrinkable cable end jointing kit with lugs for 3.3 KV XLPE cable for 3 core 300 sq.mm | 4 | no | - | - |
| 2.003 | OD148153/2024-2025:Fixing and termination of the 3 core 300 sq.mm XLPE 3.3 KV cable end kit(shrinking indoor type) | 4 | no | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Tendernotice_2.pdf
PDF • 0.10 MB
BOQ_1192676.xls
BOQ • 0.40 MB
NITwithsupplementay.pdf
Tender Documents • 7.84 MB
Tenderdocument.pdf
Tender Documents • 7.84 MB
BOQ.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .