Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 7 608 AQUATECH HOUSE UDAYAMPEROOR SOUTH PARAVOOR KERALA 682307 | UDAYAMPEROOR | SOUTH PARAVOOR | KERALA | 682307 | L1 | Accepted-AOC L1 Bidder Agreement Executed |
Tender Value
₹30.0 L
EMD Value
₹50,000
Closing Date
18 Dec 2024, 3:00 pmClosed
EXECUTIVE ENGINEER
OFFICE OF EXECUTIVE ENGINEER PROJECT DIVISION KOCHI 11
AMRUT OCEMS SYSTEM FOR 5MLD STP AT ELAMKULAM OCEMS GENERAL CIVIL WORKS
2024_KWA_715531_1
RE TENDER 02/PD/CHN/2024-24 (RT-1)
Open Tender
Civil Works - Water Works
Item Rate
120 days
ELAMKULAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,258
₹50,000
21 Jun 2025
11 Dec 2024
19 Dec 2024
11 Dec 2024
18 Dec 2024
11 Dec 2024
Amount
Supply and Installation of water quality monitoring System
OD136468/2024-2025:"Online multi::parametric COD, BOD. TSS, pH & Chlorine Analyzer With GPRS data transmission to KSPCB portal Supplied with Spectrophotometric Sensor (COD, BOD. TSS), pH Analyser (pH), Chlorine Analyser (Chlorine) and con::cube terminal Make: S::CAN. AUSTRIA con::cube terminal-specifications are; display:-color-display 9"TFT function indicator:- 4 x LED operation via :- integrated touch-screen Ethernet operating system:-embeddeo XP main memory:- 2 GB RAM onboard memory:- 16GB RAM interface to s::can spectrometric probes:- M12RSTS 8Y(IP67), RS485, ETHERNET interface to S::can sensor:-4X sys plug, RS455 interface to third party sensor:- Modbus RTU/TCP, analog inputs network connection:- 802.11n a/b/g WIFI 300Mb/s Ethernet LAN 1Gb/s world wide 3G HSPA+ interface to SCADA:- modbus RTU/TCP, analog outputs data transfer:- via SSH, FTP,TML(XML) and USB stick remote control :- via HTPP power supply:- 10...30 VDC grounding:-<0.5 ohm to process media Online Chlorine Sensor-Chlorine Analyser-specifications are measuring principle amperometric measuring principle detail potentiostatic 3-electrode system measuring range application 0 … 20 mg/l resolution 0.01 mg/l automatic compensation instrument temperature response time 2 min. integration via Con::cube power supply 9 … 18 VDC interface connection to s::can terminals sys plug, IP 67, RS485 housing material PVC weight (min.) 175 g dimensions (diameter x length) 35 x 213 mm operating temperature 5 ... 45 °C storage temperature 5 ... 45 °C operating pressure 0 ... 1 bar installation / mounting flow cell flow velocity 0.015 m/s (min.) 0.06 m/s (max.) power consumption(typical):- 1.5W (in sleep mode)10W(no analogue ports) 30W(fully equipped) analog outputs:- upto 8x2x0/4-20mA analog inputs:- upto 8x2x0/4-20mA output for automatic cleaning :- 2 relay output:- 4x2A(500VAC) system error :- 1x2A(500VAC) dimensions:-280x209x85mm housing material:- aluminium alloy, powder coated weight(min):- 4kg operating temperature:- -20 to 50 degree celcius storage temperature:- -20 to 60 degree celcius humidity range:- 5 to 90 % protection class:- IP 65 Conformity-EMC:- EN61326-1 Spectrophotometric sensor:-measuring principle UV-Vis spectrometry 190 - 750 nm measurement interval 10 sec automatic compensation cross sensitivities turbidity / solids / organic substances Measuring range COD: 0-1500 mg/L BOD: 0-800 mg/L TSS: 0-1200 mg/L reference standard distilled water onboard memory 8 GB integrated temperature sensor 0 ... 45 °C resolution temperature sensor 0.1 °C integration via Con::cube power supply 10 ... 18 VDC power consumption 3 W power consumption (max.) 20 W Interface connection to s::can terminals M12 RSTS 8Y (IP67), RS485, Ethernet cable length 7.5 m fixed cable Cable type PU jacket housing material stainless steel 1.4404 weight (min.) 3.4 kg (incl. cable) dimensions (diameter x length) 44 mm x 457 mm / 501 mm operating temperature 0 ... 45 °C storage temperature -10 ... 65 °C operating pressure 0 ... 3 bar installation / mounting submersed or in a flow cell Flow rate 3 m/s (max.) mechanical stability 30 Nm ingress protection class IP68 automatic cleaning media: compressed air permissible pressure: 3 ... 6 bar conformity - EMC EN 61326-1 pH SENSOR - pH Analyser -specifications are measuring principle Potentiometric measuring principle detail combined, non-porous reference electrode measuring range application 2 ... 12 resolution 0.01 pH accuracy 0,1 pH automatic compensation instrument Temperature response time 30 sec. integrated temperature sensor 0 ... 90 °C integration via con::cube power supply 9 … 18 VDC interface connection to s::can terminals sys plug (IP 67), RS485 cable length 7.5 m cable type PU jacket housing material stainless steel 1.4404/1.4401 weight (min.) 400 g dimensions (diameter x length) 33 x 257 mm operating temperature 0 ... 70 °C storage temperature 10 ... 60 °C operating pressure 0 ... 10 bar installation / mounting submersed or in a flow cell process connection quick connect protection class IP 68 automatic cleaning media: compressed air permissible pressure: 3 ... 6 bar cleaning interval: depending on application conformity –EMC EN 61326-1 conformity safety EN 61010-1 "
OD136500/2024-2025:Extended Warranty Charges for 2 years
OD136504/2024-2025:Calibration charges along with calibration certificate - uv-vis spectrometer for parameters cod bod tss as per CPCP/KSPCB sop. Includes calibration of cod bod and tss with minimum 21 effluent samples taken in different intervals and analysed through nabl/pcb approved laboratory, for ph -standard 4,7,and 9 buffer 500ml bottle each
OD136506/2024-2025:Compressed air line to sensors for automatic cleaning
OD136508/2024-2025:UPS power supply
OD136509/2024-2025:For civil, mechanical and electrical work
Bidder Name
Aquatechnics Water Treatment Technologies P Ltd
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1128197.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .