| 1 | L1₹33.8 LAccepted-AOC 20 C RAGHUVANSH ENCLAVE KALIDAS ROAD DEHRADUN | L1 | Accepted-AOC ok | |
| 2 | L2₹34.3 L+₹37,165.25 (1.10%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-AOC ok | |
| 3 | L3₹38.9 L+₹5.0 L (14.7%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC ok | |
| 4 | L4₹41.0 L+₹7.1 L (20.9%)Rejected-AOC 37 2 INDIRA COLONY CHUKHUWALA DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC ok |
Tender Value
₹48.5 L
EMD Value
₹99,000
Closing Date
16 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun
PERIODICAL SERVICES TO CERTAIN MD OTM ACCN AT ANARWALA UNDER AGE BR-I OF GE DEHRADUN
2022_MES_502210_1
9681/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹99,000
Yes
22 Mar 2022
18 Jan 2022
18 Feb 2022
18 Jan 2022
16 Feb 2022
2 Feb 2022
60 days
Amount
M&L for preparation of old decorated plastered or un plastered surfaces of walls and applying one coat of cement base paint on external wall surfaces complete all as specified and directed.
M&L for complete removal of existing treatment, preparation of old decorated plastered or un plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer on external wall surfaces complete all as specified and directed.
M&L for preparation of old decorated plastered or un plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of putty/ plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old decorated surfaces & applying one coat of white wash on ceiling complete all as specified and directed.
M&L for complete removal of existing treatment, and applying 1 to 1.5mm thick wall care putty on wall surfaces even and smooth complete all as specified and directed.
M&L for preparing of old painted wood or wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and directed.
M&L for preparing of old painted steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing of old AC sheet surface by brooming down with steel wire brushing and washing with water and applying one coat of cement base paint , complete all as specified and directed.
Taking down cement plaster on brick or stone etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 (with water proofing compound if ordered by Engineer-in-charge) is to be finished even and smooth (without using extra cement) on external surfaces of chajja, facia, parapet, toilet shafts etc complete all as specified and as directed.. Note : 1.Water proofing compound shall be measured and paid separately as supply only. 2. Cost of scafolding for rendering is included in this item. Note : Rendering will be done in two layer. 1st layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 is to be finished even and smooth (with out using extra cement) complete all as specified and directed.
M&L for 10 mm thick plastering on ceiling in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering on fair faces of brick/concrete surfaces of wall 10 mm thick in patches n exc 3 Sqm in cement mortar (1:4) mixed with water proofing compound, surface finished even and fair without using extra cement. Note:- WPC will be measured and paid separately.
M&L for rendering on fair faces of concrete surfaces, chajja/facia 10mm thick in patches n exc 3 Sqm in cement mortar (1:3) mixed with water proofing compound surface finished even and fair without using extra cement. Note:- WPC will be measured and paid separately.
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirting, drip moulds, chajjas and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. complete all as specified and directed.
Supply only Liquid water proofing compound
M&L for preparation of new plastered or un plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for removing /cutting trees vegetation, digging out roots from concrete or brick wall filling holes on building (block of 6 qtrs) wall/roof/chajja/water tank staging area etc and making good with cement mortar 1:2:4 complete all as specified and directed.
M&L for removing /cutting trees vegetation, digging out roots from concrete or brick wall filling holes on building (block of 12 qtrs) wall/roof/cajja/water tank staging area etc and making good with cement mortar 1:2:4 complete all as specified and directed.
M&L for Cutting around the pipe 75/100mm bore waste pipe/soil pipe including taking out plant roots up to any depth in brick masonry and re jointing in pipe joint in appoxy mortar (Asian/Berger) and making good to existing surface complete all as specified and directed. After the jointing pipe one week to be open for checking of leaking including scaffolding.
S&F 100 mm bore CI long trap 60 cm including replaced of old WC trap fixed with CI/ PVC pipe in any position make good with cement mortar 1:4 complete all as specified and directed
S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed.
S & F in repair 90 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring, fixed on wall including taking down complete all as specified. Note :- Sample of pipe to be approved by Engr-in-Chage before installation.
S & F in repair 110 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring, fixed on wall with PVC/ GI clamps complete all as specified. Note :- Sample of pipe to be approved by Engr-in-Chage before installation.
S & F in repair 75 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring, fixed on wall with PVC/ GI clamps complete all as specified. Note :- Sample of pipe to be approved by Engr-in-Chage before installation.
S & F in repair UPVC (SWR) junction single, (Single T) equal or unequal, door bend, bend, etc 90 mm bore with access door complete all as specified.
S & F in repair UPVC (SWR) junction single, (Single T) equal or unequal, door bend, bend, etc 110 mm bore with access door complete all as specified and directed.
S & F in repair UPVC (SWR) junction single, (Single T) equal or unequal, door bend, bend, etc 75 mm bore with access door complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B' brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class 'B' brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6, but except bricks including all quoins, arches, pillars etc complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work and demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick in ground floor and paving below or above ground level complete all as specified and directed.
M&L for demolition of existing PCC, treating of joints, filling of honey combs with using crack fill chemical of Dr Fixit or STP and providing 25 mm thick PCC (1:2:4) type B-0 with WPC over roof surface complete all as specified and directed.
M & L for rendering 10 mm thick plastering in roof surfaces in cement mortar 1:4 with WPC (If ordered by Engineer-in-Charge), complete all as specified and directed.
M & L for providing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application, shall be laid over hot blown bitumen grade 85/25 conforming to IS 702 @ 1.2 kg per Sqm over a coat of bituminous primer and applying aluminium reflective paint over it, including taking down existing membrane complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including necessary welding, drilling hole complete all as specified and directed.
M&L applying two coats of black Japan paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
Alankar Traders
M/s Anil Kumar
AYUSH CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .