| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC 37 CENTRAL ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | ₹2.9 Cr | L1 | Accepted-AOC Stood L1 and got approved in 311th STC-I meeting of TSECL on 05/05/2025 |
| 2 | L2₹2.9 Cr+₹1.5 L (0.53%)Rejected-Finance AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | ₹2.9 Cr+₹1.5 L (0.53%) | L2 | Rejected-Finance Not the lowest one |
| 3 | L3₹3.3 Cr+₹38.0 L (13.0%)Rejected-Finance DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | ₹3.3 Cr+₹38.0 L (13.0%) | L3 | Rejected-Finance Not the lowest one |
| 4 | L4₹3.6 Cr+₹69.1 L (23.7%)Rejected-Finance AGARTALA TRIPURA W | AGARTALA | TRIPURA | ₹3.6 Cr+₹69.1 L (23.7%) | L4 | Rejected-Finance Not the lowest one |
| 5 | Rejected-Technical SHIBNAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical Does not meet the requirement as per the clause mentioned in Bid Document regarding JV |
Tender Value
₹3.3 Cr
EMD Value
₹5.4 L
Closing Date
2 Apr 2025, 3:00 pmClosed
DGM(Project), South Tripura.
Office of the AGM, EC-Belonia, South Tripura. Pin-799155
Electrification of un-electrified Households and Public Places under DA-JGUA Scheme in South Tripura District of Tripura State
2025_POWER_59740_1
DGM(Project)/ EC-Bln/ 24-25/01
Open Tender
Electrical Works
Works
South Tripura District.
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹5.4 L
15 May 2025
22 Mar 2025
3 Apr 2025
22 Mar 2025
2 Apr 2025
27 Mar 2025
24 Mar 2025 - 26 Mar 2025
Amount
Supply of the followings 9.00 mtr. long Steel tubular pole 410 SP 30
9m PCC Pole
8m PCC Pole
8.00 mtr. Long Steel tubular pole 410 SP 22
20 sqmm GI Stay set Complete
Stay wire 7/3.15mm
Stay insulator(LT)
Stay insulator(HT)
100X50x50X6 mm MS Channel
75X40X40x6 mm MS Channel
65X65X6 mm MS Angle
50x50x6 mm MS Angle
ACSR (6/1/2.59 mm) weasel conductor
11 KV composit (polymer) Disc insulator, 45 KN
11 KV composit (Polymer) Disc Fittings
11 KV polymer Pin insulator
Lighting Arrestor 9 KV, 05 KA
25KVA, 11/0.433 KV Distribution Transformer
50 sqmm PVC cable for transformer ckt connection
63 Amp Cut Out
11 KV GOS (3-Phase)
11 KV DOF(3-phase)
40 mm dia GI pipe 2.5 mtr long (Make:-TATA/JINDAL)
60 kg salt & 55 kg Charcoal (For 1 pit)
GI Barbed wire
1.1 KV LT AB Cable 3x25+1x16+1x25 sqmm
1.1 KV LT AB cable 1X25+1X16+1X25 sq.mm.
Suspension clamp
Dead End clamp
Eye Hook
Cable tie with adjustable locking arrangement
Pre-insulated mid span jointing sleeves
GI pole clamp /Double SS straps for fixing eye hook to 8 mtr ST pole i/c GI N&B/ Strapbuckles.
Insulated Piercing connector
Three Phase LT ABC Distribution box
Single Phase LT ABC Distribution box
PVC 2.5 sq.mm, Cable (For Service)
10 SWG G.I Wire(for holding Service Cable) (904 nos S/C @ 3 Kg)
Single Phase 5-30 Amp Whole Current Energy Meter
Reel insulator
Danger Plate [L.T]
Danger Plate [H.T]
Carring of 9.0 mtr long STP Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as required Upto 8 nos pole
Carring of 9.0 mtr long STP Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as required Beyond 8 poles
Carring of 9.0 mtr long PCC Pole from Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as requiredUpto 4 nos pole
Carring of 9.0 mtr long PCC Pole from Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as requiredBeyond 4 poles
Carring of 8.0 mtr long STP Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as required Upto 8 nos pole
Carring of 8.0 mtr long STP Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as required Beyond 8 poles
Carring of 8.0 mtr long PCC Pole from Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as requiredUpto 5 nos pole
Carring of 8.0 mtr long PCC Pole from Storeyard to worksite by Mechanical Transport i/c loading, unloading, stacking etc. as requiredBeyond 5 Nos poles
Carrying of 25 KVA Txr. From Storeyard to Worksite by Mechanical Transport i/c loading, unloading etc. as Required
Erection of the following Steel Tubular Pole 9.00mtr long
PCC pole 9 Mtrs long
Steel Tubular Pole Pole 8.00mtr long
PCC Pole 8 Mtrs long
Guard Wire (8 SWG G.I Wire)
ACSR (6/1/2.59 mm )
11 KV Polymeric Pin insulator
11KV Polymeric Disc insulator
11 KV , 3 Phase G.O.S
11 KV , 3 Phase D.O.F
2.80mtr long M.S Bracket made of 100x50x50x6 mm M.S. Ch
0.80 mtr long M.S Bracket made of 100x50x50x6 mm M.S. Ch
2.80mtr long M.S Bracket made of 75x40x40x6 mm M.S. Ch (GOS & DOF)
2.80mtr long M.S Bkt. made of 65X65X6mm mm M.S. Angle (GOS Handle & S/S Guard Bkt)
0.3 mtr long S.P top bkt. made of 75x40x40x6 mm M.S. Ch
1.2 mtr long S.P bottom bkt. made of 75x40x40x6 mm M.S. Ch
1.5m long S.P guard bkt. made of 65x65x6 mm M.S. An
1.8 mtr long D.P top bkt. made of 75x40x40x6 mm M.S. Ch
2.2 mtr long D.P bottom bkt. made of 75x40x40x6 mm M.S. Ch (i/c 17 nos.Tapping Bkt)
2.5 mtr long D.P & Tapping guard bkt. made of 65x65x6 mm M.S. Angle
11 KV Protective Guarding
Fabrication of cross arm made by the M.S Angle/ Channel
Erection of Stay set complete
Erection of Barbed Wire
Erection of Danger Plate
Providing of Coil Earthing
Supply & erection of substation fencing with erection of 6nos 2.50m long ( 65 x 65 x 6mm) Angle post and 4nos( 50 x 50 x 6mm)angle post with grouting of vol 0.045cum at the ratio of 1:2:4(1cement :2R. sand : 4 jhamabrick aggregate) per post. The fencing should be made 9 horizontal line of barbed wire and one gate with shutter (2 x 1.7)m i/c locking arrangement etc complete as per diection of the Engg. in charge.
Installation of 25 KVA Distribution Transformer
Fitting fixing of Cut- Out set with cable connection with supply of wooden plank
Earthing with G.l pipe 2.5mtr. Long and 40mm dia, including excavation , refilling with alternate layer of salt and charcoal as per drawing ( excluding supply of G.l.Pipe, Salt & Charcoal, Giwire, nuts &bolts, etc. as reqd )
Laying, hoisting & drawing of L.T AB Cable (3x25+1x16+1x25 sq.mm)
Laying, hoisting & drawing of L.T AB Cable (1x25+1x16+1x25 sq.mm)
Erection & Fitting-fixing of inulated suspension clamp i/c pole clamp, eye hook for cable messenger
Erection & Fitting-fixing of inulated dead end clamp assembly i/c pole clamp, eye hook for cable messenger
Erection & Fitting-fixing of inulation piercing connector
Erection & Fitting-fixing of 1-Ph Distribution Box
Erection & Fitting-fixing of 3-Ph Distribution Box
Supply and erection of Stay clamp
Supply and erection of GI Bracket clamp by 50X6mm
Supply & Erection of GI Nuts & Bolts i/c washer, ISI markedmachine made(assorted size)
Providing Single phase Service connection with all accessories
Grouting of Steel Tubular Poles ( @ 0.273 cum x 773 nos )
Supply of 16 Amp ICDP Main switch with ISI mark
Supply of 8''x 12'' Wooden / Polycarbonate Meter Board
Supply of Wooden Plank (thickness 1") (1.5 Mtr x .25 Mtr.
Supply of 9W LED Bulb (reputed make)
Supply of Angle Holder with ISI Mark
Supply of 4x4" Wooden/Polycarbonate Board
Supply of 5 Amp Piano switch with ISI Mark
Supply of Single Core 1.5 Sqmm Copper wire
Supply of Screw of assorted size
Supply of PVC pipe of 20 mm dia (reputed make)
Erection Charge of all items from Sl. No. 2.05 to 2.14(i/c preparing Coil earthing for S/c with 8 SWG G.I wire) (1 Job@ Rs.950)
UTTAM NAG (BID ID -171635)
ADHIR DEBNATH (BID ID -171587)
M/s Bhattacharjee Construction (BID ID -171731)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .