Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹39.4 LAdmitted-Finance VILL BELIABATHAN P O BIDHANBAG DIST PASCHIM BARDHAMAN PIN 713337 | BIDHANBAG | PASCHIM BARDHAMAN | WEST BENGAL | 713337 | L1 | Admitted-Finance | ||
| 2 | L2₹41.3 L+₹1.8 L (4.58%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹45.5 L+₹6.1 L (15.4%)Admitted-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Admitted-Finance |
Tender Value
₹41.3 L
EMD Value
₹82,596
Closing Date
27 Jul 2026, 2:00 pmClosed
Senior S.E,CEC, PWD.
Office of the Senior SUPERINTENDING ENGINEER, Central Electrical Circle 184, C.R.Das Road, Berhampore, Murshidabad, PIN-742101
Construction of proposed G3 storied Research and Innovation Complex within the campus of Kalyani University in the district of Nadia SITC AC Machines
2026_WBPWD_5015702_1
WBPWD/CEC/NIT/01/T/26-27
Open Tender
A/C ORG
Percentage
21 days
Kalyani
Please refer Tender documents.
5 documents required · 5 mandatory
₹82,596
Office of the Senior S.E,CEC, PWD.
3 Aug 2026
18 Jun 2026
28 Jul 2026
22 Jun 2026
27 Jul 2026
25 Jun 2026
24 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of Cooling Capacity- 6.1 kW (Minimum), Air Flow Rate: 800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4- Star (min) comprising Indoor and Outdoor Units with factory charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) (Make: RR Kabel Ltd./Finolex/Havells) with suitable plug top (Make: Anchor), 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on a 230 V, 50 Hz (+ tolerance as per the applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions, conforming to IS- 1391 (Part-II) with all amendments. It shall be capable of efficient performance at outdoor ambient temperatures up to 50° C, with a minimum 5-year OEM warranty on both the compressor and PCB. | |||||
| 1.01 | The system shall be installed with S&F appropriate fixing arrangements ‘as per OEM recommendations, including wall openings, mending well the damages and making necessary connections, including T&P & labour, ete., as required, complete in all respects as per the direction of EIC ( Make: O-General /MITSUBISHI ELECTRIC / Daikin ) | - | Each | - | - |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of sof/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | |||||
| 2.01 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | - | R,M | - | - |
| 3S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sq. mm, 3/4 core copper cable (FRLS type) (Make: RR Kabel Ltd./Finolex/Havells) | |||||
| 4Supply & laying Soft Drawn PVC Drain Pipe exceeding 3 mtr of 19 mm dia with proper supports & brackets as per direction EIC. | |||||
| 5Hiring charges for scaffolding arrangement, including dismantling at the end of work and carriage, AC installation, (per storey of building per vertical run) as per GS. | |||||
| 6Supplying and fixing of MS outdoor structures for 2 nos AC units. The structure consist of 4nos MS U-channels (each 1m length, 6mm thick, 65x40x40mm) with necessary wall supports. Includes supply and installation of a 2.5m length platform with necessary barricade made of 35mmx35mmx5mm MS angle and 50x6mm flat pati. Work includes wall cutting, grouting with cement concrete, welding, and painting as per direction of E.I.C. | |||||
| 7Supplying and fixing of MS outdoor structures for 1 nos AC units. The structure consist of 2 nos MS U-channels (each 1m length, 6mm thick, 65x40x40mm) with necessary wall supports. Includes supply and installation of a 1.25m length platform with necessary barricade made of 35mmx35mmx5mm MS angle and 50x6mm flat pati. Work includes wall cutting, grouting with cement concrete, welding, and painting as per direction of E.I.C. | |||||
| 8Cutting of existing iron window with S & F iron hinged door with key & locking arrangement for maintenance af AC machine incl necessary welding painting etc as per direction of EIC. | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_5084642.xls
BOQ • 0.32 MB
2911.pdf
Tender Documents • 0.54 MB
cori_time2.pdf
PDF • 0.30 MB
cori_time.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .