| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC VALSALYAM KONNAMOODU KODANGAVILA PO | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.5 L+₹86,081.64 (7.41%)Rejected-AOC FLAT NO 4 461 VALAMKOTTIL TOWERS JUDGEMUKKU KAKKANAD THRIKKAKA ERNAKULAM | ERNAKULAM | ERNAKULAM | KERALA | L2 | Rejected-AOC L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance KL BHAVAN MANKALA | - | Not Admitted-Fee/PreQual/Technical/Finance EMD exemption certificate not valid |
Tender Value
₹13.7 L
EMD Value
₹34,200
Closing Date
10 Feb 2026, 5:00 pmClosed
Asst Executive Engineer
Electrical Sub Division, Vizhinjam
LT ABC at Kanjiramkulam and Exchange Tr area, under Electrical Section, Kanjiramkulam
2026_KSEB_832254_1
Tender/2025-26/4217/37 dated 27.01.2026
Open Tender
Electrical Works
Percentage
180 days
Kanjiramkulam
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,900
₹34,200
Yes
4 Mar 2026
30 Jan 2026
13 Feb 2026
30 Jan 2026
10 Feb 2026
30 Jan 2026
30 Jan 2026 - 10 Feb 2026
Reconductoring with LT ABC
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading.
Loading HT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Insertion of one HT PSC pole in existing line incl. digging & backfilling pit, fitting cross arm, insulators, binding etc.
Pole numbering using printed Aluminium sheets / Painting the surface of pole with anti algal yellow paint and painting Letters with black paint as specified incl. cost of paint.
Loading LT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Erecting one LT PSC Pole in position incl. digging & back filling pit.
Providing Fly stay for LT pole using LT PSC pole incl. digging & back filling pit.
Providing Stay for LT poles incl. digging & back filling pit.
Renewal of existing damaged/broken old LT stay with existing stay rod.
Providing Strut using LT PSC pole incl. digging & back filling pit.
Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling.
Installing One No. 4 way Satellite Connector of size Main :16 to 95, Tap:4 to 35 Sq.mm to the LT AB cable of Standard size
Transporting LT ABC by hired vehicle to a distance up to 5 km and carring up to 2 drum including loading and un loading using crane
Stringing of 1.1 kV Aerial bunched cable of size 3 x 70 + 1 x 16+1x 50 sqmm with bare/insulated Messenger through existing poles
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Dismantling (without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
Redoing single phase service connection including lowering down the guy wire portion repairing/changing WP wire and reconnecting the same including conveyance of material to site from section office at various
Redoing three phase service connection including lowering down the guy wire portion repairing/changing WP wire and reconnecting the same including conveyance of material to site from section office at various
Stringing of 1.1 kV Aerial bunched cable of size 1 x 25 + 1 x 25 sqmm with bare/insulated Messenger through existing poles
Dismantling 2 Line spacer from existing OH Line
Dismantling 3 line spacer on the existing LT OH line
Erection of Anchor clamp / dead end clamp for LT ABC of any size
Providing End Caps
Providing Cable Tie
Erection of suspension clamp for LT ABC of any size
Installation of Pre-insulated straight through joints for 16sqmm cable
Installation of Pre-insulated straight through joints for 50sqmm cable
Installation of Pre-insulated straight through joints for 70sqmm cable
Installation of Pre-insulated lugs for 70sqmm
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm
Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm
Fitting of one No. pole top service connection box of standard size (up to 4 way) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height excluding giving connections
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1398886.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BID.pdf
Tender Documents • 0.73 MB
BOQ_1398886.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .