Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC accepted | |
| 2 | L2₹16.9 L+₹62,264.29 (3.81%)Rejected-AOC | L2 | Rejected-AOC rejected | |
| 3 | L3₹17.3 L+₹95,374.03 (5.84%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹17.3 L+₹97,542.24 (5.97%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹17.8 L+₹1.5 L (9.14%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹20.7 L
EMD Value
₹50,000
Closing Date
27 Aug 2024, 6:00 pmClosed
Executive Engineer
PWD, Roads Division Kannur
GENERAL Construction of culvert Retaining wall Flood Damage 2023 24 Reconstruction of collapsed retaining wall of culvert at Thundiyil Kolakkad Malayampadi Road Ch 4 800 General Civil Work 1
2024_PWD_686735_1
PWD/RB/TR/14151/2023_5_1_1/1
Open Tender
Civil Works - Roads
Item Rate
180 days
Iritty
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
Yes
₹50,000
Yes
14 Oct 2024
19 Aug 2024
30 Aug 2024
19 Aug 2024
27 Aug 2024
19 Aug 2024
Amount
Appendix A
2.4.2.A:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Cement Concrete Grade M-15 & M-20 - By Mechanical Means
3.13.1.B:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.<br> Ordinary soil - Mechanical Means - (Depth upto 3 m) <br>
3.4:Excavation for roadway in ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site of embankment upto a distance of 100 metres ( average lead 50 metres ), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.
12.4:Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
12.8.1.C:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> RCC Grade M20 - Using Concrete Mixer - (Without formwork) <br>
OD94878/2023-2024:Bailing out water in trenches using 5HP pump including cost of fuel , lubricating oil all labour charges incidental expenses etc..complete as per std. specification and as directed by thr deptl. officers.
12.8.A.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15
OD94879/2023-2024::providing weep holes in brick masonry/plain/reinforced concrete abutment,wing wall/return wall with 75mm dia pvc pipe exactly through the full width of the structure with slope of IV :20H towards drawing foce cuples as per drawing and technical specifications
13.9.A:Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification Granular material
8.4.12:Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminum sheeting, 2 mm thick/aluminum composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. 50cmx 60 cm rectangular (Single chevron etc.)
8.4.2:Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.<br> 60 cm equilateral triangle
K C DIJEESH KUMAR
VYSHAK P
MANOJ XAVIER
Abdul Jamal P
DKH CONSTRUCTIONS LLP
SALY PAUL KANNANTHANAM
RAVEENDRAN. K
Bidder Name
RAVEENDRAN. K
VYSHAK P
MATHAI VD
K C DIJEESH KUMAR
SALY PAUL KANNANTHANAM
DKH CONSTRUCTIONS LLP
MANOJ XAVIER
Abdul Jamal P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1068593.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .