| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance PLOT NO 195 QUAY STREET OPP NAGINA HOTEL DARUKHANA REAY ROAD EAST MUMBAI MAHARASHTRA 400010 | MUMBAI SUBURBAN | MAHARASHTRA | 400010 | Admitted-Finance |
| 4 | Admitted-Finance 31 NEELGIRI IND ESTATE T J ROAD SEWRI W MUMBAI MAHARASHTRA 400015 | MUMBAI | MAHARASHTRA | 400015 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
15 Feb 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIVEK KORDE
MDL MAZAGON DOCK MUMBAI 400010
Normal Refit of ICGS ACHOOK for offloading refit job to Eligible Ship Refit Firms.
2021_MDL_84982_2
2500000023
Limited
Miscellaneous Services
Service
120 days
OTS MDL MUMBAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
18 Feb 2021
10 Feb 2021
15 Feb 2021
10 Feb 2021
15 Feb 2021
10 Feb 2021
90 days
REFITTING OF ICGS ACHOOK (Y-72180)-HULL
FIRM SERVICES
02 in nos carry away pipes for hull discharge openings to be provided during dry-docking. (Service code-HA1007)
Portable AC towers and ventilation blowers (06 each.) to be provided onboard for adequate ventilation at all times when ship’s air conditioning system cannot be used/non-operational.(Service code-HA1016)
Gas free certification for all tanks and confined spaces to be obtained from department of explosives/Firm safety.(Service code-HA1017)
GENERAL SERVICES Pre and post refit trials to be carried out to assess the performance and status of all equipment and fittings. All PAC/OEM, Firm reps from Hull, Engg, Electrical departments to embark onboard for pre and post refit trials. AIAMC firms shall also be embarked for pre and post refit trials as required.(Service code-HA1001)
Adequate fire sentries to be provided during hot work.(Service code-HA1015)
Ship is required to be dry docked in version I and II by MDL as per the docking plan provided by Coast Guard. In case of any change in Docking plan then firm has to only quote for approval charges from Classification Society. (Docking Plan will be provided by MDL).(Service code-HA1024)
UNDERWATER WORK HULL AND APPENDAGES
Wash and clean under water hull including appendages with hydro dynamic jet (3000 PSI) and brushes, then clean with F/W thoroughly. After cleaning examine the whole under water area paying particular attention being given to hull plating in the vicinity of shafts zinc protectors, sea tube and all other fastenings and wind water areas for signs of corrosion defects and damage. Class surveyor to be associated for all inspections. Firm to take due care for underwater fittings, sensors (EM log, echo sounder) and appendages. Includes all in way jobs. Material Firm supply.(Service code-HA1025)
Renew all sacrificial anodes fitted on sea tubes. (Mat- Zinc Qty -12nos) Anodes Firm supply. Class surveyor to be associated for all inspections post fitment. Includes all inway jobs. Material Firm supply. Size of the anodes as follows: (a) 125 x 30 x 25 mm, qty 05, weight 0.7 kg (b) 100 x 30 x 25 mm qty 07, weight 0.55 kg (Service code-HA1026)
Fifty per cent of U/W area (including boot top) to be blasted to SA 2.5 standard and apply touch up paint scheme as per approved scheme. Paint scheme – Sigma PPG. Paint Firm supply.Airless painting (including boot top) to be carried out under supervision of paint rep and report to be rendered. Firm to cater for water jet tunnel painting. Underwater area including appendages (400 sqmtr) and boot top area (70 sqmtr) Water jet tunnels included in underwater area. Paint scheme : Under water paint scheme (M/s PPG Sigma ) 1. Sigma prime 200 yellow /green 2. Sigma shield 620 rb 3. Sigma glide 790 grey 4. Sigma glide 990 dark red 5. Sigma glide 990 black (Service code-HA1028)
Carry out robotic scanning and UTG survey of underwater area (including boot top) paying particular attention to E/R, tanks, shaft areas and sea tube through ICG approved firms. Those plates thinned down more than 10% to be cropped and renewed. Critical plates to be marked in drawings for renewal in forth coming refit.Report of UTG survey be given in shell expansion drawing and tabular form. Firm to cater for 05 Ton steel renewal. Payment to be made on actuals. Firm to cater for 500 points for UTG survey. Steel grade AH36 Thickness 05 mm. Class surveyor to be associated for inspection and remarks to be endorsed on report. Steel renewal as per class surveyor recommendations.(Service code-HA1027)
HULL (UNDERWATER FITTINGS)
Remove, clean and refit all sea tube gratings (14 nos). Material Firm supply. Includes all inway jobs. Note:-1.All U/W fittings (echo sounder, EM log, tanks plugs) to be free from dock blocks. On docking clean all appendages and apply grease and cover with tarpaulin/polythene before blasting commence. No of Grating Details(water jet-03, main engine-03, GS pumps- 02, RO plant -01, DA- 03, A/C -01, direct flooding-01)(Service code-HA1031)
STEEL DECKS (EXPOSED),SHIP SIDE, ALUMINIUM DECKS,SUPERSTRUCTURE
Carry out survey of Ship’s side, weather decks/exposed decks, aluminium decks and super structure including mast with class surveyor for structural integrity and UTG to be carried out. Examine all structure paying particular attention to all areas where aberration is possible. Check bulkhead and ship side above main deck (bimetallic joint) for paint failure, structural damage etc. Check ATU compartment, bridge areas and boundaries for corrosion and deterioration. Doubtful areas where obscured structure, portable fittings to be removed by Firm for inspection. Area as follows:- Ship’s side along weather deck – 550 sqmtr Aluminium weather deck – 100 sqmtr Firm to cater for 500 UTG points and submit UTG report endorsed with class surveyor recommendations. All inway jobs included. Steel renewal as per class surveyor recommendation. Payment to be made as per actual record maintained by ship staff. Firm to cater for 02 Ton steel renewal. Steel grade AH36. Thickness – 05 mm. Firm to cater for 500 KG aluminium renewal. Aluminium grade AL5083 Thickness 05 MM. Payment to be madeon actual as per record maintained by ship staff.(Service code-HA1032)
WEATHER DECK (STEEL DECKS). Full paint scheme to be applied for weather decks using airless spray as per approved paint scheme post surface preparation. Area – 260 SqMtr. Existing paint scheme – M/s Sigma. Job includes blasting of 78 nos stanchion and stanchion shoes to bare metal and application full paint scheme through airless painting. Paint Firm supply. All consumables and material Firm supply. All inway jobs included. Queries:- M/s Homa – Paont scheme to be provided. No UTG gauging are normally carried out on Aluminium structure only visual inspection. Paint scheme to be provided.(Service code-HA1033)
SHIP’ SIDE Entire ship side to be abrasive blasted to SA 2.5 and complete paint scheme to be applied using airless spray as per approved paint scheme. Present paint scheme – M/s Sigma PPG. Paint Firm supply. All consumables and material Firm supply. All inway jobs included.(Service code-HA1034)
Carry out inscription of ‘Indian Coast Guard’ in hindi (stbd) and English (port) as per policy on ship side. Draft markings and blue band on both sides to be painted. Paint – CG supply.(Service code-HA1035)
ALUMINIUM DECKS Aluminium decks to be scraped and painted as per touch up paint scheme. Paint Firm supply. Area – 100 sqmtr Present paint scheme – M/s Sigma PPG. Paint Firm supply. All consumables and material Firm supply. All inway jobs included.(Service code-HA1036)
GALLEY AND ASSOCIATED FITTINGS
Following routines to be carried out a) Renew the galley grease filter. (Qty – 02 Size 30 x 38 cm, mat- SS) as per sample. b) Clean the flue collector trunks and exhaust trunking (approx. running length – 10 mtrs) with wire brushes and paint with black heat resistance paints. Paints Firm supply.(Service code-HA1037)
Galley bulkhead and false ceiling emanating foul smell due to rat infestation and possible rat faeces. Galley hot plate, cupboards, fittings (microwave, garbage disposal system, 02 fridge, 01 deep freezer, electric panels etc) to be removed and refitted. False bulkhead and ceiling to be removed and underlying area to be inspected and cleaned (approx. area 60 mtrsqr).Deteriorated lagging to be renewed. Firm to cater for 30 mtrSqr for MFFB lagging. Additional requirement of lagging to be projected under AWRF. Deterioration of SS false ceiling or bulkhead to be projected for renewal/repair under AWRF.(Service code-HA1038)
MACHINERY COMPARTMENTS (FWD AND AFT E/R, W/J COMPARTMENT)
Clean all bilges of AER, FER, WJ compt, Void spaces, fore peak, coffer dam and limber holes (Area 180 Sq. Mtr) limber holes inspect the frames, girders and stiffeners etc. Damage areas to be surface prepared and repaint as per touch up scheme and apply 01 full final coat. Ballast tanks, Cofferdams, Void spaces, Fore peak etc. (Area 350 Sq. Mtr) Paint Firm Supply. Scheme- Sigma . Bilges area – 700 sqrmtr Cofferdams, Void spaces, fore peak etc area 420 sqrmtr. Firm to associate class surveyor and submit report. Material and paint Firm supply. BILGES (ZINC/ NON ZINC SPRAYED) (a) SIGMA COVER 280 (b) SIGMA COVER380 GREEN (c) SIGMA COVER 380 GREY(Service code-HA1039)
TANKS (GREY WATER,FRESH WATER,DIRTY OIL,DIRTY WATER,LUB OIL,FUEL OIL)
Following tanks to be open, dry out and ventilate, clean and examine interior surface for corrosion. Man hole cover gaskets to be renewed. (a) Lub Oil tank (E/R) – 01 no. (01KL) (b) Diesel Oil tank – 04 nos (21Kl-01 no, 06 KL- 01 no and 05 Kl – 02 nos) (c) Dirty oil tank – 01 nos (0.8KL) (d) Dirty water tank – 01 nos ( 0.8 KL) (e) Fresh water tank – 01 nos (10.5T) (f) Grey water tank – 01 nos (08.1T) (g) Hydraulic oil storage tank – 02 nos (330 ltrs each) All material and consumables Firm supply. Includes all inway jobs. Firm to submit gas free certificate against HA-1017. Firm to associate class surveyor for inspection and submit class recommendations. Oil tanks not to be painted. Air pressure test of fuel oil tanks to be carried out and certificate to be submitted through ICG authorised agency. Defects, if any, to be projected under AWRF.(Service code-HA1040)
Minute leakage observed from foot valve of stbd RU fuel oil tank (tank no. 4). Same to be removed, repaired, pressure tested and proved for satisfactory performance. (Service code-HA1041)
FRESH WATER TANK ( Area 81 mtr sqr)
Fresh water tanks to be painted as per touch up paint scheme. Paint Firm supply. Paint Scheme – M/s Sigma PPG. Material, Paint and consumables Firm supply. (a) Sigma cover 280 (b) Sigma guard720 green (c) Sigma guard 720 grey(Service code-HA1042)
GREY WATER TANK (Area 50 mtrsqr)
GREY WATER TANK (Area 50 mtr sqr) Clean and remove any loose or flaking paint and all signs of corrosion by scraping and wire brushing.Ensure all strainers, limber holes and valves are clear and thoroughly dry before touch up as per paint scheme. Firm to undertake touch up paint scheme. Paint Firm Supply.(Service code-HA1043)
ANCHOR, ANCHOR CAPSTANS, CABLE LOCKER AND MOORING CAPSTAN
Cable to be ranged out from cable locker. Joining shackles to be opened, cleaned, greased and refit. Gauge the cable in consecutive links and record. Any link found thinned beyond permissible limits to be renewed. Move and lubricate anchor flukes. Examine blakeslip, bottle screw slip and associated fittings. On completion of all jobs, anchor and cable to be painted as per paint scheme and take cable onboard changing cables end to end. Anchor hammer testing to be carried out. Class surveyor to be associated for all inspections and report be rendered. Job includes shot blasting of cable and anchor. Paint and material – Firm supply. (Service code-HA1044)
Carry out survey of cable locker. (area – 40 mtrsqr). Remove portable perforated plates. Sump, suction strainer and box to be cleaned. Structure in vicinity of cable clench, shipside, plates and bars, stiffeners to be examined. Specific defects if any to be projected. Recoat as per touch up paint scheme. Carry out one final coat. Paint scheme – Intertuf 262 KHA 304/A Grey and Intertuf 262 KHA 302/A black. Paint Firm supply. (Service code-HA1045)
Dismantle anchor capstan (02 nos) Make: M/s GRSE Model no: BS-420M/A 1200734. Remove capstan and lower gear box. Strip down for examination of all bearing, bushes, shafts, gears, clutch and brake lining. Deteriorated parts to be renewed. Renew brake lining. Grease all pins and adjust/replace. Test the capstan on no load and then on load up to 2.1 tons. Firm to provide load test certificate through authorised firm. Oil, spares and material Firm supply(Service code-HA1046)
Mooring capstan (Make: M/s GRSE GA 2/S) to be dismantled and gear box to be lowered.Strip down for examination of all bearing, bushes, shaft, gears (including worm and worm wheel), clutch and magnetic brake. Holding bolts to be removed and examined. Capstan oil to be changed. Grease all pins and adjust/replace. Test the capstan on no load and then on load and prove. (Test load – 2.1 tons). Firm to carry out renewal of magnetic brake. Spares, oil and consumable – Firm supply.(Service code-HA1047)
Anchor capstan controls (01 nos) and mooring capstan controls (01 nos) box deteriorated. Box to be dismantled along with stand and inspected for corrosion. Overhauling of box and stand to be carried out. Joint inspection of control box to be carried out by SS, Firm and COA and renewal if any to be projected. Job includes renewal of SS tallies with inscription (directions) on box. Rubber coaming of box to be renewed and box to be proved for water tight integrity. Total tallies 16 Nos. Length of rubber coaming – 02 mtr approx. Thickness – 05 mm. (Service code-HA1048)
VENTILATION SYSTEM
All rubber coaming of ventilation flaps, Doors and Hatches to be renewed and chalk test to be proved. Additionally, all weather deck fittings to be hose tested post rubber renewal. External hatch/door material – EPDM length Approx -120Mtr Thickness 20mm Width – 40 mm hardness – 50+5.(Door – 09 nos, hatches – 05 nos Flaps – 38 nos) Internal hatch/door material – Neoprene rubber length approx. – 45mtr Thickness 20mm width 40 mm hardness – 50+5 (door – 05 nos hatches 03 nos) Material Firm supply. Firm to submit guarantee certificate for a period of 12 months.(Service code-HA1051)
Overhauling of quick shutdown valve of AC system (magazine compartment) to be carried out.(Service code-HA1052)
ARTICULATED CRANE(MAKE: M/S PELLIGRINI MODEL NO: GS1/4.9)
Overhaul the electric motor, clutches and hydraulic system. Prove the hydraulic system for operating pressure. Change hydraulic hoses. Check the current rating (power pack). Open gearbox and inspect gear for physical damage. Dismantle the fixed arm and telescopic arm. Inspect arms and bearing. Inspect the gliding plate units inside telescoping arm. Check all hydraulic valves and cylinders. On completion refit the system and prove for operation at specified SWL (01 Tons). Spares, oil and consumables – Firm supply. Job to be undertaken through PAC firm.(Service code-HA1053)
Survey and load test davits together with all associated fittings, ropes, blocks pulleys etc. (SWL-01 Ton) test certificate to be provided. Proof test shall include. (a) Hoist and lower the main hook. (b) Auxiliary hook load and boom. (c) Slewing and luffing. (d) Test of safety. (e) Fail safe and limit switches. (f) Load movement. (g) Boom angle indicators. Post load test, foundation, sheaves, rope guides and wire ropes with end connectors, hoists brakes and clutches to be examined and report be rendered with class surveyor recommendation.(Service code-HA1054)
BOLLARD,CLEAT AND FAIRLEAD
Die penetration test (DPT) of following deck fittings to be carried out (a) Bollards - 08 nos (b) Cleats - 40 nos (c) Stag horns - 10 nos (d) Roller fairlead – 04 Nos (e) Fairlead – 08 Nos (f) Bull ring (centreline fairlead) –02 nos (g) Towing hook base 01 No. Firm to associate class surveyor and render report with surveyor recommendations.(Service code-HA1055)
TOWING SLIP
Conduct load test of towing slip and fitments up to 05 tons and provide load test certificate from MMD authorised firm.(Service code-HA1056)
SEWAGE TREATMENT PLANT(STP) (Jobs to be undertaken through PAC firm)
Strip, clean and replace 100% of soil pipes. (a)Mat: PVC- Size- 60mm Length-25 Mtr (b)Mat: GI, Dia-60mm Length-10 Mtr (c)Mat: GI, Dia-40mm Length-4 Mtr (d)Mat: GI, Dia-50mm Length-10 Mtr (e)Mat: GI, Dia-20mm Length-05 Mtr (f)Mat: GI, Dia-10mm Length-10 Mtr(Service code-HA1060)
MISCELLANEOUS
Ship’s metal defender/combing on shipside along the weather deck corroded and peeled off at multiple location. To be renewed. Mat – Solid MS pipe/rod. Length – 110 mtrs, Dia – 08 mm. Job includes welding of pipe and grinding from ship side to ensure smooth surface and finishing.(Service code-HA1062)
Ship’s jackstaff and ensign staff securing shoe bent due to prolonged usage in rough weather. To be repaired. Job includes renewal of SS nuts and bolts.(Service code-HA1063)
Water ingress observed through bridge false ceiling during rainy weather/deck washing. Suspect ingress through cracked seal of magnetic compass/loud hailer. DI/DR to be carried out and water ingress to be arrested. Job includes removal of magnetic compass, cleaning and refittment. Joint inspection to be carried out post removal of magnetic compass by Firm, SS and CoA. Material and spares Firm supply.(Service code-HA1064)
Macrotech flooring top coat deteriorated/ scratches observed in following locations. One top coat to be applied (colour – grey). In way job includes removal & fitment of all fittings e.g lockers, tables, sofa, bunks etc. Location: Officer’s alleyway Bridge and MSO 20 P mess SO’s mess Dining hall Ships office Galley 2 P mess SO’s Bathroom Naviks Shower area Naviks Toilets Washroom alleyway.(Service code-HA1065)
20 nos stanchion shoes are cracked at various places. To be renewed as per sample. Mat :- MS(Service code-HA1066)
Water seepage observed from bridge window toughened glass seal. Glass seals to be renewed and hose test to be carried out for proving water tightness. (Qty – 11 Approx length of seal – 44 mtrs)(Service code-HB1069)
Water seepage observed from bridge clear screen system rotating discs. Overhauling of clear view screen system (model – WS300CR Qty – 03) and prove for smooth operation and water tightness. Equipment rating IP56.(Service code-HB1070)
04 nos heavy deck eyes for gangway securing bent. To be renewed. Dimensions per eye as follows: (a) Base plate thickness – 05 mm (b) length 06cm x 10 cm. Includes all inway jobs and removal/refitment of lagging of underlying compartments .(Service code-HB1071)
30 in nos deck tally base perished due to frequent removal and refitment. Double plate to be welded on all deck tally positions and deck tallies to be refitted. Length – 12 cm x 04 cm per double plate. Thickness – 05 mm. All inway jobs included. Queries:- M/s CCPL – Renewal of under deck insulation against AWRF.M/s Sadhav - Require material specifications.(Service code-HB1072)
Dining hall water cooler/purifier drainage pipe cracked and perished at multiple locations. Pipe to be renewed. Length – 12 mtrs Mat – PVC Dia 20 mm. Job includes removal and refitment of overlying fittings.(Service code-HB1075)
REFITTING OF ICGS ACHOOK (Y-72180)-Electrical
MAIN SWITCH BOARD (415V & 230V AC) (MAKE- M/S MARINE ELECTRICALS, MUMBAI), QTY- 01 NO.,LOCATION- MCR, OEM/ PAC FIRM: M/S MARINE ELECTRICALS, MUMBAI
Calibration of following MSB meters to be carried out and submit calibration certificate:- Sl Description Qty (a) Kw meters(0-150kw) 03 nos. (b) Ammeter(0-200amps) 01 no. (c) Ammeter(0-300 amps) 03 nos. (d) Ammeter(0-100 amps) 01 no. (e) Volt meter(0-300v) 01 no. (f) Volt meter(0-600v) 04 nos. (g) Frequency meter(45-55hz) 04 nos. (h) Synchroscope 01 no. (j) Double frequency meter(45-55hz) 01 no. (k) Double voltmeter (0-600v) 01 no. (l) Power factor meter 03 nos. (m) Earth fault meter (230v) 01 no. (n) Earth fault meter (415v) 01 no.(Service code-LA5001)
(a) Complete overhauling of MSB panel to be carried out. (b) Check all bus/terminals, connectors are properly tightened. (c) Carry out overhauling of 01 no. bus coupler (630 Amps). (d) Check earth fault circuit, synchroscope and synchronizing lamp for correct operation. (e) Calibrate all MCBs with safety trips/relays & replace defective components. Details of MCBs as follows:- Sl Description Qty (a) 15 amps breakers 28 nos. (b) 20 amps breakers 05 nos. (c) 25 amps breakers 06 nos. (d) 30 amps breakers 07 nos. (e) 50 amps breakers 03 nos. (f) 60 amps breakers 05 nos. (g) 80 amps breakers 02 nos. (h) 160 amps breakers 01 no. (j) 100 amps breakers 01 no.(Service code-LA5002)
Carry out functional test of following circuit breakers, relays for over load, reverse power, under/over frequency and under/over voltage protection. Submit Test certificate.Insulation resistance test of breakers and associated controls to be carried out (minimum acceptable value 1 mega ohm) and proved for satisfactory operation. Sl Description Qty (a) Moulded Case Circuit Breaker (250A) 03 nos. (b) Over current protection/short circuit relay 03 nos. (c) Under voltage protection relay(380 V) 08 nos. (d) Reverse power tripping relay 03 nos. (e) Insulation monitor relay 02 nos. (Service code-LA5003)
Calibration of 03 Generator Protection Unit (GPU) and check proper functioning with safety trips.(Service code-LA5004)
MSB earth faults to be rectified and insulation of 415V and 230V set to satisfactory value.(Service code-LA5005)
14 nos. shock/ vibration mounting of MSB panel to be renewed as per sample, if required. (Material : Yard supply)(Service code-LA5006)
POWER DISTRIBUTION BOX AND LIGHT DISTRIBUTION BOX (MAKE- M/S WAVES ELECTRONICS) TYPE:415 V/230V AC AND 24 V DC, QTY –20 NOS.
Overhaul the switch fuse unit. Replace deteriorated cables, Terminals connectors and fuse carriers if any.(Service code-LA5007)
Overhaul the distribution boards including renewal of painting, locks and replace defective components, if any (Material : Yard supply)(Service code-LA5008)
LRAD (MAKE: M/S HYPER SPIKE, TYPE- HS-14), QTY- 01 NO., LOCATION- BRIDGE WING (STBD)
Complete overhauling of LRAD to be carried out. Replace water tight gasket, sound emitter protection filter, mic holder and hand mic cable (Cable- spiral cable,06 core,0.15 sq mm, length- 250 mm).(Service code-LA5020)
SHORE SUPPLY CONNECTION BOX & ENERGY METER, 415V 3P 160 AMP (MAKE: M/S WAVES ELECTRONICS, TYPE- E-2175, QTY- 01 NO., LOCATION- WEATHER DECK
Complete overhauling of the shore connection box to be carried out including painting and replace defective components and locking arrangements. Job includes overhauling of 160A MCCB. Material: Yard supply.(Service code-LA5021)
Calibrate following meters/breakers and submit calibration certificates:- Sl Description Qty (a) Voltmeter (0-500 V) 01 no. (b) Ammeter (0-150 A) 01 no. (c) Frequency meter (25-60 Hz) 01 no. (d) Energy meter (360 amp/kWh) 01 no. (e) Breaker (160 amps) 01 no. (f) Phase sequence meter 01 no.(Service code-LA5022)
WEATHER DISPLAY, WEATHER STATION (MAKE- M/S ELCOME MARINE, TYPE: EWSMS 1.1, WXT-520), OEM/PAC FIRM: M/S ELCOME INTEGRATED SERVICE PVT LTD, MUMBAI, QTY-01 NO., LOCATION- BRIDGE
Overhaul the complete system. Calibration to be carried out and system to be proved for wind speed and direction w.r.t. hand held anemometer/ fixed anemometer.(Service code-LA5023)
ANEMOMETER (MAKE- M/S ELCOME MARINE, TYPE: WALKERS 2050 MK2T), OEM/ PAC FIRM: M/S ELCOME INTEGRATED SERVICE PVT LTD, MUMBAI, QTY-01 NO., LOCATION- BRIDGE
Check condition of wind vane mounts/ brackets for corrosion and repair, if needed. Material : Yard supply.(Service code-LA5024)
Overhaul the equipment including sensors and calibrate anemometer for speed and direction with reference to hand held anemometer and standard readings and to be proved for satisfactory operation. (Service code-LA5025)
EMERGENCY SWITCH BOARD (MAKE- M/S WAVES ELECTRONICS, COCHIN,TYPE: 230V/50HZ), QTY-01 NO., LOCATION – EDA COMPARTMENT
Calibration of voltmeter & ammeters including breakers to be carried out and submit calibration certificates:- Sl Description Qty (a) Voltmeter (0-500 V) 01 no. (b) Ammeter (0-200 A) 01 no. (c) Frequency meter (45-55 Hz) 01 no. (d) Breaker (400 amps) 01 no. (Service code-LA5031)
NAVIGATION LIGHTS CONTROL PANEL (MAKE- M/S TRANSBERG, TYPE: DHR70), QTY-01 NO., LOCATION –WHEEL HOUSE
Overhaul the navigational lights control panel including JBs (Qty- 06 nos.), navigational light fittings (Qty- 10 nos.) and output relay modules (Qty- 04 nos.). Replace defective components, if any. (Material : Firm supply).(Service code-LA5032)
TEST PANEL (MAKE- M/S LARSEN & TOUBRO, TYPE: SYPZ860), OEM/ PAC FIRM: L&T LTD., QTY-01 NO.
Calibration of all voltmeter & ammeters to be carried out and submit calibration certificates. Sl Description Qty (a) AC ammeter (0-10 amps) 02 nos. (b) DC ammeter (0-10 amps) 01 no. (c) AC voltmeter (0-415 V) 01 no. (d) AC voltmeter (0-230 V) 01 no. (e) DC voltmeter (0-24 V) 01 no. (Service code-LA5033)
SIGNALLING PROJECTOR (MAKE- M/S NORSE LIGHT, TYPE: XS 1000 D), OEM/ PAC FIRM: M/S GLAMOX INTERN, QTY-02 NOS., LOCATION- BRIDGE WING (P&S)
Overhauling of both signaling projectors to be carried out and replace defective components including water tight seals. (Material: Firm supply).(Service code-LA5034)
DIESEL ALTERNATORS (MAKE- M/S KIRLOSKAR/ CROMPTON GREAVES, TYPE:6SL9088TA/G1R250LD), OEM/ PAC FIRM: M/S KIRLOSKAR OIL ENGINES LTD., NASHIK ,QTY- 03 NOS. (PORT, STBD &CENTER)
Check steady state of generators, overhaul complete generators including starter motors, dynamo, thorough inspection of winding state, cleaning, varnishing and baking for improvement of insulation and replace bearings.(Spares : Firm Supply)(Service code-LA5035)
After overhauling carry out test and full load trials. Parallel operation of all three DAs to be proved with equal sharing of loads as well as amps value.(Service code-LA5036)
Following safety trips and alarm along with sensors for all three diesel generators to be calibrated and proved :- (a) Low lub oil pressure - 03 nos. (b) High water temperature - 03 nos. (c) Over speed trip - 03 nos. (d) Lub oil temperature - 03 nos. (e) Expansion tank level indicator - 03 nos. (f) Fuel level off sensor - 03 nos. (g) Winding high temperature alarm - 03 nos. (Service code-LA5037)
Following control panels gauges to be calibrated and submit calibration certificate:- (A) Lub oil pressure gauge(0-10 bar) - 03 nos. (B) Fresh water temperature gauge (0-150oC) - 03 nos. (C) Sea water pressure gauge(0-2.5 Bar) - 03 nos. (D) Exhaust gas temperature(Digital) - 03 nos. (E) Lub oil temperature (0-150oC) - 03 nos.(Service code-LA5038)
Overhauling of DA local control panel (Qty- 03 nos.) including calibration of Generator Protection Unit (Make-M/s DEIF) to be carried out.(Service code-LA5039)
TRANSFORMER (MAKE- M/S MARINE ELECTRICALS, MUMBAI, MODEL: 10KVA 415/230 V 1PH), QTY- 06 NOS., LOCATION: AMR
Complete overhauling of all transformers including cleaning, varnishing and baking of winding to be carried out. Replace the earthing straps.(Material : Firm Supply.(Service code-LA5040)
FIRE DETECTION SYSTEM (MAKE- M/S AUTRONICA, MODEL- BS 420 M/A 1200734), QTY- 01 NO., LOCATION: BRIDGE, OEM/ PAC FIRM- M/S ELCOME MARINE,MUMBAI
Overhaul complete system along with all sensors & calibration of system. Replace defective components. All loop faults to be cleared and system to be proved for satisfactory performance.(Service code-LA5041)
MCS-5/RCS CONTROL PANEL (MAKE- M/S MTU INDIA LTD., PUNE, TYPE: MCS/RCS-5, MODEL- 16V 4000M-90),QTY-03 NOS., LOCATION:BRIDGE/MCR, OEM/ PAC FIRM- M/S YMPL, MUMBAI
Following safety trips and alarms along with sensors of three engines to be calibrated and proved.(Spares : CG Supply) (a) Low lub oil pressure alarm and trip (b) Over speed trip (c) Low starting air pressure alarm (d) Low raw water pressure alarm (e) Low coolant pressure alarm (f) High coolant temperature alarm and power reduction (g) Low gear box lub oil pressure alarm and trip (h) Low fresh water level alarm in expansion tank (j) Operation of exhaust flap mechanism/ limit switch (k) High lub oil temperature alarm (l) High gear box temperature alarm (m) Low fuel oil alarm pressure (n) High fuel leak alarm (p) Exhaust gas temperature failure alarm (q) High crankcase pressure trip (r) Emergency stop : interlock (s) Neutral not in position : interlock (t) Barring gear engaged : interlock (u) Gear Control oil pressure low: trip(Service code-LA5042)
Following measuring instruments in Local/ MCR/ Bridge to be calibrated and proved:- Sl Description Qty Location (a) Engine speed indicator 06 nos. MCR& Bridge (b) Shaft speed indicator 06 nos. (c) Reversing position indicator 06 nos. (d) Bucket Position indicator 06 nos. Queries:- M(Service code-LA5043)
Storage tank level sensors of fuel tanks (1 & 2), RU fuel tanks (port & stbd), fresh water tank (01) and grey water tank (01) to be calibrated and to be proved with the MCS-5 indication system in MCR & Wheel House.(Service code-LA5044)
Hatch closing sensor/ limit switch (Qty- 11 nos.) operation and their indication in MCS-5 in MCR & Wheel Houseto be checked and defective components to be replaced.(Service code-LA5045)
Functional checks of bilge level indication (Qty- 08 nos.) in MCS-5 panel in MCR & Wheel House and replacement of defective components, if necessary. (Service code-LA5046)
Exhaust gas monitoring system to be checked for satisfactory operation and replace defective component, if any.(Service code-LA5047)
Following miscellaneous status to be proved in both MCS-5 indication systemin MCR & Wheel House:- (a) Fresh water hydrophore (b) Air compressor 1 & 2 (c) Oil separator (d) Sewage treatment plant (e) Purifier (f) Bilge and GS pump (g) Fire main pressure (h) Fire and GS pump (j) A/C plant (k) AHU (l) Fuel oil pump 1 & 2 (m) RO plant auxiliary equipment room.(Service code-LA5048)
03 nos. DA running indication, lub oil pressure and fresh water temperature of 03 DAs to be calibrated and to be proved with MCS-5 indication system in MCR & Wheel House.(Service code-LA5049)
Inspect all PIM modules and carryout functional checks. Replace defective components if any.(Service code-LA5050)
MCS-5/RCS (UPS) (MAKE- M/S MTU INDIA LTD., TYPE/MODEL: MCS-5/ RCS), QTY- 02, LOCATION- AUX. MACHINERY COMPT.
Complete overhauling 02 nos. of UPS including varnishing and baking of 02 transformers (230/24V, 90 amps & 415/24V,2.2 KVA) to be carried out. Calibrate all meters.Check the condition of the paint. Repaint, if necessary. Sl Description Qty (a) DC ammeter (0-100 amps)04nos. (b) DC volt meter (0-40 V)04 nos.(Service code-LA5051)
WATER JET (MAKE- M/S ROLLS ROYCE, TYPE- 71S3NP), QTY- 02 NOS., LOCATION- WJ COMPARTMENT, OEM/ PAC FIRM-M/S KONGSBERG MARITIME CM.INDIA PVT.LTD.
Carry out functional test of control system and control levers in MCR and wheel house and readjust, if required.(Service code-LA5052)
Carry out operation checks and calibration of sensors, alarms, switches, digital flow meter and pressure gauges fitted in the hydraulic power packs.(Service code-LA5053)
Carry out calibration of shaft seal flow meter.(Service code-LA5054)
Port waterjet local control panel plug in FER securing loose. To be renewed and proved for satisfactory operation.(Service code-LA5055)
Stbd main engine ROS in bridge malfunctioning intermittently. Same to be checked and rectified. (Service code-LB5056)
Cooper bearing temperature sensors showing erratic indication in MCS-5. Same to be rectified and proved for satisfactory operation.(Service code-LB5057)
DA/ BATTERY CHARGER AND CONTROL PANEL (MAKE- M/S KIRLOSKAR, TYPE- 6K/SL90), QTY- 03 NOS., LOCATION- FWD & AFT ENGINE ROOM
Carry out overhauling of charger and control panel. Following jobs also to be undertaken during overhauling:- (a) Check the corroded mounting bases (b) Check proper function of rectifier unit and switches etc. (c) Check the insulation of the cable (d) Check the condition of the paint. If required, repaint.(Service code-LA5058)
Calibrate all 03 in nos. voltmeters and 03 in nos. ammeters of charger and submit calibration certificates.(Service code-LA5059)
AUTO TELEPHONE EXCHANGE (QTY- 01 NO.), TALKBACK (QTY- 03 NOS.) (MAKE- M/S ZENITEL MARINE ASIA PVT LTD, TYPE- ACM ETB-05)
Overhauling of auto telephone system (Qty- 01 no.) and talkback system (Qty- 03 nos.) to be carried out. (Spare - yard supply)(Service code-LA5060)
Check all telephone lines/ cables/ spiral cables, junction boxes and replace defective components, if any.(Service code-LA5061)
Telephone connection point in quarter deck deteriorated. Connection point to be repaired and proved for satisfactory operation.(Service code-LB5062)
External line connection point mounting bracket deteriorated in port catwalk. Same to be fabricated and fitted as per sample.(Service code-LB5063)
SOUND POWERED TELEPHONE (MAKE- M/S ZENITEL MARINE ASIA PVT LTD, TYPE: VSP 12 WAY), QTY- 05 NOS.
Overhaul complete system and replace the defective component, if any. (Spare Firm supply).(Service code-LA5064)
Spiral cables for 05 nos.handset units defective and to be renewed. (05 core, 0.15 sq mm, Length- 250 mm). Cable : Yard supply.(Service code-LB5065)
ELECTRIC SIREN (MAKE- M/S KOCKUMSONICS LTD., TYPE- ETD-100/350), QTY- 01 NO., LOCATION- BRIDGE
Complete overhauling of the system to be carried out and replace the deteriorated components and weather sealing gaskets.(Spare- Firm supply).(Service code-LA5068)
AIR HORN (MAKE- M/S KOCKUMSONICS LTD, TYPE- MKT-75/440), QTY- 01 NO., LOCATION- BRIDGE
Calibration of voltmeter & ammeters including breakers to be carried out and submit calibration certificates:- Sl Description Qty (a) Voltmeter (0-500 V) 01 no. (b) Ammeter (0-200 A) 01 no. (c) Frequency meter (45-55 Hz) 01 no. (d) Breaker (400 amps) 01 no.(Service code-LA5069)
SEARCH LIGHT (MAKE- M/S TRANSBERG, TYPE: TEF2650), QTY- 01 NO., LOCATION: BRIDGE
Overhaul the equipment completely, replace seals and gaskets and prove the system for satisfactory operation.(Service code-LA5070)
GENERAL MOTORS & STARTERS AND CONTROL PANELS
Following motors and its starters/control panels are to be overhauled:-Overhauling of motors includes following:-(Service code-LA5071) (a) Blow through the motor internally with vacuum cleaner. Care should be taken to avoid damage to winding, wiring and components.(b) Check and renewal of bearings.(c) Cleaning with CTC and varnishing the winding with air drying varnish, baking in over for at least 10 hours. (d) Examination of the rotor impeller, shaft bearing housing for flaws, cracks and corrosion. Make good and replace as necessary. (e) Internal and external painting of motor casing by spray paint. (f) Carry out trueness check of motor shaft repairs including build up and machining of shaft.(g) Re-balance of rotor and impeller, replacement of terminal boxes, terminal blocks, cooling fan, fan guard, foundation and nut/bolts as necessary.(h) Check earth straps of motor and replace if necessary.(j) Measure the insulation resistance of motor using 500V megger both before and after rewinding.(k) Carryout inspection of vibration mounting. Renewal of gasket / seals and foundation nuts / bolts.Overhauling of starters/ control panels includes following:-(a) Clan the control panels and renew deteriorated wiring / lugs and terminal blocks. Care should be taken that while cleaning; no component is damaged or displaced. Tighten all wiring terminations and electrical connections.(b) Open, clean and replace all contactor spare kits irrespective of their condition of all running machinery. (c) Replace all indication lamps and alarm hooters if defective. (d) Carry out settings of pressure/temperature switches and threshold settings of cards.(e) Calibrate all relays for desirable parameter setting and confirm as per instructional manuals / tests or trials data (SS to record and compare).(f) Inspect and renew shock / vibration mounting. (g) Switch on and carryout functional tests to prove the system and compare with test/ trial report. (h) Check and replace earth straps. Sl Description Rating (KW) Qty (nos.)(a) Bilge & GS Pump Motor 9.3 01 (b) Fire & GS Pump Motor 9.3 01 (c) AHU Motor 7.5 01 (d) Air Compressor Motors 7.5 02 (e) Fuel Oil Purifier Separator Motor 4.0 01 (f) AC Condenser pump No.1& 2 3.7 02 (g) Fuel Oil Transfer Pump 3.7 02 (h) Oily Bilge Water Separator Motor 3.2 01 (j) Fresh Water Hydrophore Pump Motor 2.24 02 (k) Grey Water Pump Motor 3.7 01 (l) W/J Hydraulic Pump No 1,2 &3 2.2 03 (m) Fwd Engine Room Ventilation Fan 11 02 (n) Aft Engine Room Ventilation Fan 11 01 (p) Aux equip room /Naval Store Supply Fan 0.37 01 (q) EDG Room Ventilation Fan 0.10 01 (r) Magazine Room Exhaust Fan 0.37 01 (s) Galley Supply Fan 0.37 01 (t) Galley Exhaust Fan 0.37 01 (u) Water Jet Compartment Supply Fan 0.37 01 (v) Sanitary Space Exhaust Fan 0.37 01 (x) Battery Room Exhaust Fan 0.188 01 (y) Paint Store Exhaust Fan 0.188 01 (z) STP Compartment Supply Fan 0.37 01 (aa) Baggage/ Victualling Store Fan 0.504 01 (ab) Garbage Disposal Unit 0.75 01 (ac) Electric motor for Crane 03 01 (ad) W/R pantry exhaust fan 90W 01
ANCHOR WINDLASS MOTORS AND CONTROL PANEL(PORT&STBD)(MAKE-M/S.GRSE,QTY-2NOS,LOCATION-STP/FOXLE)
Overhauling of both anchor windlass motor (415V, 3PH, 4 KW, 50Hz) and DC magnetic brake assembly (110V DC, 55W) to be carried out. Adjust air gap of electromagnetic brake for satisfactory operation.(Service code-LA5072)
Overhauling of both control panel to be carried out and calibrate of 04 nos. overloads relays and proved post overhauling.(Service code-LA5073)
AFT MOORING CAPSTAN MOTOR AND CONTROL PANEL, MAKE: M/S GRSE, QTY- 01 NO., LOCATION: AFT E/R & W/J COMP
Overhauling of mooring capstan motor (415V, 3PH, 4 KW, 50Hz) and DC magnetic brake assembly (110V DC, 55W) to be carried out. Adjust air gap of electromagnetic brake for satisfactory operation.(Service code-LA5075)
Overhauling of control panel to be carried out, overload relay to be calibrated and system to be proved for satisfactory operation post overhauling.(Service code-LA5077)
FM-200 CONTROL PANEL (MAKE: M/S TYCO, MUMBAI, TYPE - FM 200), QTY- 01 NO., LOCATION- FM-200 COMPARTMENT
Carry out following operational / functional checks of FM 200 system:- (a) Check that all pneumatic actuator operates after pneumatic time delay. (b) Check that all electric actuator operates afterpre-set time delay. (c) Check operation of discharge pressure switch. Upon operation, check indication lamps are lit on indication panel. (d) Test electric control heads and shut-off operation of all associated onboard ventilation, fuel supply and indication on remote alarm system. (e) Calibrate all pressure threshold devices and system to be proved.(Service code-LA5078)
EMERGENCY DA (MAKE: M/S KIRLOSKAR, TYPE- KOEL TA2/STAMFORD PM044F, QTY- 01 NO., LOCATION: EDA COMPARTMENT
Check insulation of the cable. Also check all safety trips for proper functioning and prove the system. (a) Over speed alarm & Trip (b) High fuel leakage (c) Low lub oil pressure (d) Lub oil temperature.(Service code-LA5079)
Overhaul alternator and calibrate all safeties and renew mounting pads and defective component if required. After overhauling carry out test and full load trial. (80%, -3.68 kW).(Service code-LA5080)
COOKING RANGE (415V/50 AC, 50 HZ, 3PH) (MAKE- M/S SUSHMA ELECTRICALS, MUMBAI, QTY- 01 NO., LOCATION- GALLEY
Overhauling of galley hot plate along with ovens to be carried out.(Service code-LA5081)
Replace the heat resistance cable along with heat proof porcelain sleeves from hot plate elements to terminal post and terminal post to main supply terminal. (03 sqmm, length-15 mtrs). (Material: Yard Supply). Renew asbestos sheets provided in each hot plate as per sample. (03mm thick, 02 nos.)(Service code-LA5082)
Overhaul control panel and renew all defective components and replace all contactor spare kits irrespective of condition. (Spares: Yard supply).(Service code-LA5083)
15 LTRS WATER BOILER (MAKE- M/S SUSHMA ELECTRICALS, MUMBAI)
Dismantle the heating elements and clean or rescale them thoroughly. Check the fuses, switches, dry cut out, replace the water level indictor and reassemble as per drawing.(Service code-LA5084)
SUBMERSIBLE PUMPS, 415V, 50Hz (20TPH-02 NOS., 10 TPH-01 NO.)
Complete overhauling of submersible pump motors including cleaning, varnishing blow drying and baking in the oven for atleast 10 hours and renewal of defective cabling if necessary. (Service code-LA5085)
Overhauling of 02 nos. 20 TPH submersible pump starter panel and renew all defective components, switches and indication lamps.(Service code-LA5086)
DISH ANTENNA SYSTEM (MAKE- M/S KNS KOREA, TYPE- KNS KOREA, QTY- 01, LOCATION- W/ROOM & BRIDGE TOP, PAC FIRM- M/S ELCOME MARINE ,MUMBAI
Overhauling of the complete unit and sub-units to be carried out. Check all gear system and belts. Satisfactory signal quality and strength to be ensured at all set top boxes. All faulty cabling, junction boxes and splitters to be renewed, and system to be proved for satisfactory operation. (Service code-LB5087)
WEATHER DECK LIGHTINGS (TYPE: 230V AC (1X60W), QTY- 01 NO., LOCATION- WEATHER DECK
16 nos. ceremonial light fittings at weather deck are deteriorated. To be renewed as per sample. (Spares : Firm Supply)(Service code-LB5088)
18 nos. ceremonial water tight socket (3 pin DP, 16A, 230V, Material: Brass) at weather deck are deteriorated. Defective sockets to be renewed as per sample. (Spares : Firm Supply)(Service code-LB5089)
AC PLANT (MAKE- M/S HEINEN & HOPMAN ENGG., TYPE: HGX5/830-4S), QTY- 02 NOS., LOCATION- FER
Overhauling of AC compressor motor (415V, 3PH, 29 KW, 50Hz) to be carried out. (Service code-LA5090)
(a) Complete overhauling of AC control panel to be carried out. (b) Check all controls and carryout functional tests. (c) Calibrate safety cut outs (Low Pressure (LP), High Pressure (HP), Differential Oil Pressure (OP)& sea water pressure) (d) Calibrate ammeters (0-100A) – 02 nos (e) Renewal all the contactors (Make- Schneider Electric, Model- LCID38, Qty- 04 nos.)(Service code-LA5091)
AIR HANDLING UNIT (MAKE- M/S EDGE TECH AIR SYSTEM, TYPE- ETU 040H,.3824/6500CFM), QTY- 01 NO.,LOCATION- AHU
Check motor anchor bolts and vibration isolation renew mounting if required.(Service code-LA5093)
Check coil and fan for corrosion, wear and tear.(Service code-LA5094)
Check fan shaft for straightness that the fan wheels are tightly fastened to the shaft and the drive sheaves are secured.(Service code-LA5095)
Clean motor frame and air passages.(Service code-LA5096)
AHU motor cables deteriorated, to be renewed as per sample and proved for satisfactory insulation and operation.(Service code-LB5097)
OILY BILGE WATER SEPERATOR (MAKE- M/S RWO GERMANY, TYPE: SKIT SDEB, CAPACITY - 0.5M/ LTR), QTY- 02 NOS., LOCATION- FER
Check and clean the sensor electrode, if necessary replace it.(Service code-LA5098)
Check the function of the heater, replace if necessary.(Service code-LA5099)
Overhauling of all electro pneumatic valves - 03 nos.(Service code-LA5100)
BATTERY CHARGER (GENERAL SERVICES) (MAKE- M/S MARINE ELECTRICALS, CAPACITY: 60 A), QTY- 01 NO., LOCATION- EDA. COMPT.
Complete overhaul of the battery charger panel to be carried out including calibration of all meters. Sl Description Qty (nos.) (a) Ammeter (0-75 amps) 01 (b) Ammeter (200-0-200 amps) 01 (c) Volt meter (0-50 V) 01.(Service code-LA5101)
UPS(10KVA) FOR IBS, QTY: 01, LOCATION: W/R LOBBY
Complete overhauling of the UPS to be carried out.(Service code-LA5119)
MB/SRE EQUIPMENTS, MAKE: ZENITEL MARINE, TYPE/MODEL: SPA-V2 , QTY. FITTED : 01, LOCATION :W/H
Overhauling of complete system to be carried out and replacement of defective components if any, prove system for all modes of operation. (Spare: Yard supply).(Service code-LA5121)
MISCELLANEOUS
Overhauling of 04 nos. water tight flood light fitting on weather deck to be carried out and replace watertight gaskets.(Service code-LA5122)
All general light fittings to be overhauled, defective driver units, faulty wiring and broken fittings to be renewed and proved for satisfactory operation.(Service code-LA5123)
Defective locks of consoles in MCR and Bridge to be renewed as per sample.(Service code-LB5124)
Locking arrangement of 13 in nos. weather deck boxes, 02 per box, to be renewed as per sample
Locking arrangement of 13 in nos. weather deck boxes, 02 per box, to be renewed as per sample.(Service code-LB5125)
SUPPLEMETARY DEFECTS
Night mode and laser range finder of EOS camera found to be malfunctioning . Same to be repaired and proved satisfactory operation. All in way jobs included.(Service code-LB5126)
Alterations and Additions. Installation of fixed H2S gas monitoring system in STP compartment. Job includes the following:- Sl Description Qty (a) Fixed H2S gas detection system 01 Set (b) H2S Sensor (H2S gas detection head) 02 Nos (c) Alarm system & cabling set 01 Set (d) Commissioning support (Installation & Commissioning) 01 Job.(Service code-LC5127)
LC-5129 Alterations and Additions. For installation of steering and reversing bucket position indicator in water jet compartment. Job includes the following:- Sl Description Qty (a) 2 core cable (1.5 sq mm) 50 mtrs (b) Ammeter DC (4-20mA) 06 Nos (c) GI Cabinet for securing Ammeter (30cm x 15 cm x 10 cm) and associated accessories) 03 Nos (d) Junction box (06 ports) 02 Nos Securing clamps for junction box As required (e) Installation charges 01 Job DO . All spare and material - Yard supply. All in way jobs included. Authority : CGHQ letter.(Service code-LC5129)
REFITTING OF ICGS ACHOOK (Y-72180)-ENGG
WATER JET & SYSTEM (MAKE- M/S ROLLS ROYCE (KAMEWA), SWEDEN, MODEL- 71SIII NP)), QTY- 03 NOS., PAC FIRM : KONGSBERG PVT. LTD., NAVI MUMBAI
Following jobs to be carried out as part of two yearly routine of three water jets& systems through OEM/ PAC firm:- (a) Carry out in-situ inspection of impeller, guide vane chamber. (b) Carry out in-situ visual inspection of shaft, shaft seal and shaft coupling. (c) Carry out in-situ inspection of bulkhead seal. (d) Carry out grease renewal of support bearing. (e) Carry out inspection of shaft and flange bolts. (f)Carry out in-situ inspection of split cone ring. (g) Carry out readjust (inspection) of shaft seal, if required. (h) Carry out functional test of counter balance valve of steering and reversing system. (j) Carry out functional test on PTO pump. Readjust, if required. (k) Carry out functional test on electric motor driven lub oil pump. Readjust pressure, if required. (l) Carry out functional test on hydraulic oil tank with valve manifold. Readjust pressure, if required. (m) Replace the high pressure and low pressure filters. (n) Carry out visual inspection of feedback transmitters. (p) Replace the cylinder seals. (q) Replace the hydraulic hoses. (r)Replace feedback protection hoses.(s) Replace hanging anodes. (t) Replace the anodes below shaft protection tube, on ship transom, water jet bucket and shaft seal. (u) Carry out the functional test on control system. Readjust, if required. (If the control system is from MTU then control rep from MTU may be required.) (v) Carry out the functional test on alarms switches and pressure gauges. (w) Calibration of levers, feedback unit & adjust indicators in MCR and Bridge. (If the control system is from MTU then control rep from MTU may be required.)(Service code-EA3001)
All three transom flanges UTG to be carried out and condition to be checked. Renewal of transom flanges to be undertaken through PAC firm, if required. Transom flange - CG supply. In way job includes drilling of bolt holes on forward/ small end diameter of transom flange as per drawing RRM200018268 D.(Service code-EB3002)
SEA CHEST VALVES
Following sea chest valves to be removed, overhauled and pressure tested up to 05kg/cm2 and fitted back (100% projected as per maintenance schedule). Sl Size (mm) Valve Type Qty (nos.) Equipment/ System (a) 150 SDSL 03 Main Engine (b) 150 SDSL 01 Magazine (c) 65 SDSL 02 GS Pump (d) 125 SDSL 01 AC Sea Water Pump (e) 65 SDSL 03 DA (f) 50 SDSL 02 RO Plant/ STP(Service code-EA3003)
OVERBOARD VALVES
Following overboard valves to be removed, overhauled and pressure tested up to 05 kg/cm2 and fitted back (100% projected as per maintenance schedule). Sl Size (mm) Valve Type Qty (nos.) Equipment/System (a) 125 SDNR 03 Main Engine (b) 65 SDNR 04 AC, Eductors (c) 40 SDNR 02 RO Plant, OBWS (d) 80 SDNR 03 DA (e) 50 Strom Valve 03 STP, Galley and AHU Room (f) 65 Strom Valve 01 Accommodation gray water pump.(Service code-EA3004)
Remove, overhaul & pressure test sea chest weed cleaning SDNR valves (Qty- 11 Nos, Test Pressure- 7.5 Bar, Size- 15 mm).(Service code-EA3005)
PME and CME exhaust trunking observed to be deteriorated due to sea water. Slight sea water leakage observed at higher RPMs. Exhaust trunking of both main engines to be renewed. In way job includes renewal of heat shield cladding and lagging. (Engine exhaust pipe size Dia- 600 mm, Mat- MS, length- 1.5 mtrs, lagging area- 6 sqmtrs each)(Service code-EB3006)
GEAR BOX (MAKE- M/S ZF, MODEL- ZF7600), QTY- 03 NOS., PAC FIRM- M/S DYNATRON SERVICES
Following jobs to be carried as part of yearly (A3.1) routine of gear box through OEM/ PAC firm: - a) Clean oil cooler and carry out pressure testing. b) Check safety devices including gear box earth connection.(Service code-EA3007)
Following jobs to be carried out as part of 2500 Hrly routines of HP Air compressors through OEM/ PAC firm:- (a) Overhaul the compressors. (b) Remove cylinder head and inspect valve plates. Replace worn out valve plates with spares if necessary. (c) All the pipe lines should be checked for leaks at joints and replace the packing if required. (d) Dismantle the non-return valve. Examine the spring for stiffness. Check the valve seat. Replace the spring and valve seat, if required. (e) De-carbonize the after cooler pipe and the inlet cooler. (f) Clean the air flow passage internally. (g) Change inlet air filter element. (h) Overhaul loader/unloader mechanism.(Service code-EA3008)
AIR CONDITIONING PLANT (MAKE- M/S BOCK (SEMI HERMETIC), MODEL- HGX5/830-4S), QTY- 02 NOS., OEM/PAC FIRM- M/S HEINEN & HOPMAN ENGG, KOLKATA
Following jobs to be carried out as part of refit routine jobs of AC plant through OEM/ PAC/ competent firm:- (a) Withdraw and inspect compressor suction and delivery valves for wear down, scoring marks. (b) Withdraw piston and inspect for wear down and scoring marks. Measure wear & tear of piston, piston rings and oil scraper rings. Replace, if not within tolerance limit. (c) Inspect small end bushes and gudgeon pins and replace, if not within tolerance. (d) Inspect all bearings for wear down and record. Renew the bearings, if necessary. (e) Measure ovulation of cylinder and record. Renew, if necessary. (f) Inspect unloading device for correct working. (g) Inspect crank shaft, undertake measurement, polish and refit, if not within tolerance limit. (h) Strip and examine lube oil pump of compressor. (j) Chemically clean both oil separators.(Service code-EA3009)
Check all controls and carryout functional tests. Reset/replace as required including safety cutouts (Low Pressure, High Pressure, Differential Oil Pressure (DOP) cutout & Sea Water (SW) low pressure cutout) Sl Safety Cut Out Qty (nos.) (a) HP cut out 02 (b) LP cut out 02 (c) DOP cut out 02 (d) SW Pressure cut out 02.(Service code-EA3010)
Clean all motor bearings, inspect for wear and tear and replace, if necessary (AC compressor motor type – 415 V, 3PH, 29 KW, 50 Hz, Qty- 02 Nos.) (Service code-EA3011)
Overhaul sea water cooling pumps. (Qty- 02 Nos) (Make: M/s SPX Flow Technology, Model: KGEC 12-6, Capacity: 16.3 m3/hr)(Service code-EA3012)
Check and replace all valve stem glands in the refrigerant line. (Qty: 31 Nos)(Service code-EA3013)
Clean both condenser, inspect for corrosion and fouling. Carry out the pressure test to 1.5 times of working pressure for 24 hours. Replace condenser gasket/O-ring.(Service code-EA3014)
Overhaul all isolating valves on cooling water (sea water) system and pressure test up to 1.5 times of working pressure. (Size- 65 mm, Butterfly cock, Qty- 06 Nos).(Service code-EA3015)
Carry out pressure test, vacuum test, and leak test of complete plant. Inspect cooling coil and return bends and check for weak spots and gland of valves by hydrostatic testing.(Service code-EA3016)
Check all cooling coils in AHUs for cleanliness and corrosions. If the coils are dirty (choked) clean, with water spray, soap solution and nylon brush and then carry out pressure test.(Service code-EA3017)
Overhaul the following isolating valves on liquid and gas lines. Renew all nylon/Teflon washers and seating. (a) Globe Valve (2 1/8’’) - 02 Nos (b) Globe Valve (1 3/8’’) - 02 Nos (c) Globe Valve (1 5/8’’) - 07 Nos (d) Angle Valve Globe Valve (3/9’’) – 20 Nos(Service code-EA3018)
Check ducts and outlets for dust. Clean and paint them if required.(Service code-EA3019)
Recharge the system with refrigerant on satisfactory completion of checks and undertake trials of plant including functional checks of safeties and cut-outs.(Service code-EA3020)
Sea water inlet/ outlet pipes and flanges of both condensers deteriorated. Same to be renewed as per sample. (Length- 02 mtrs, Dia- 60mm, Material- CuNi)(Service code-EB3021)
AIR HANDLING UNIT (MAKE- M/S EDGE TECH AIR SYSTEM, TYPE: ETU-040H), QTY- 01 NO.,PAC FIRM- M/S HEINEN & HOPMAN ENGG, KOLKATA
Following jobs to be carried out as part of refit routine of AHU:- (a) Overhauling of AHU blower including dynamic balancing. (b) Clean and check contacts, clean housing, check for proper operation and overload protection of motor starter. (c) Check fan shaft as per manufactures recommendation. (d) check for dust, moisture, defective linkages, defective insulation and leaks of diffuser and ducts (e) Check and repair all damaged pipe insulation, fitting insulation, valve insulation, duct insulation, casing and housing insulation. (f) Check blowers, dampers, filter frames coils, casing, plenums and fans for corrosion. Clean and treat as recommended by the manufacture. On completion, AHU to be proved for satisfactory performance.(Service code-EA3022)
Cold lagging of AC system pipe line from both compressor inlet to evaporator outlet deteriorated due to ageing. Same to be renewed as per sample. In way job includes removal of old lagging. (Length- 15mtrs, Dia-30mm).(Service code-EB3023)
Drain line of AHU for overboard discharge found to be deteriorated. To be renewed as per sample. (Mat- Mild Steel, Length – 04 mtrs, Dia – 80 mm). In way jobs include cutting of existing pipe and welding of new pipe with supports along the length of the pipe.(Service code-EB3024)
Foundation plate of AHU cabinet deteriorated and corroded at various places. Plate to be renew as per sample. (Size- 2440mm x 1220mm x 5mm, Mat- aluminum with cold lagging)(Service code-EB3025)
OILY BILGE WATER SEPARATOR (MAKE- M/S RWO, GERMANY, MODEL-SKIT S DEB, 0.5 M3 /HRS), QTY- 01 NO., PAC FIRM: M/S NAVICOM
Following jobs to be carried out as part of refit routine of OBWS through OEM/ PAC firm (a) Open the inspection port of the oil separator housing, the oil separator housing and the absorber housing. (b)Check for sludge deposits. If necessary, remove the sludge and clean the container. (c) Checks the inner coating. If necessary, mend damaged spots. (d) Check seals and piston valves. If necessary, replace damaged seals and components. (e) Overhaul the discharge pump.(Service code-EA3027)
HYDROPHORE PUMP (MAKE- M/S BEST & CROMPTON, CHENNAI, CAPACITY- 02 M2/HR), QTY- 02 NOS.
Following jobs to be carried out as part of refit routine of hydrophore pump:- (a)Dismantle and overhaul the pump completely. Clean and inspect each item thoroughly and renew, if necessary. (b) Calibrate/ renew all gauges (Qty- 04 nos.) (c) Check and flush all tube work and suction and delivery piping.(Service code-EA3028)
FUEL OIL TRANSFER PUMP (MAKE- M/S ROYSONS ENGG, KOLKATA RGP-MF, CAPACITY- 06 M3/HR), QTY- 02 NOS.
Following jobs to be carried out as part of refit routine of FOT pumps:- (a) Overhaul the pump. (b) Check the alignment of pump with motor. (c) Renew pump mechanical seal/stuffing box, if worn out / leaking. (d) Calibrate/renew all gauges (Qty- 04 nos.) On completion of above jobs pumps to be proved for satisfactory performance. Renew spares, if necessary.(Service code-EA3029)
BILGE & GS PUMP AND FIRE & GS PUMP (MAKE- M/S SPX JOHNSON PUMP, MODEL: CV 50 200 (B3M2TL)), CAPACITY- 40TPH, QTY-02 NOS.
Following jobs to be carried out a part of refit routine of bilge/fire & GS pump:- (a) Dismantle and overhaul the pump completely, clean and inspect each item thoroughly and renew, as necessary. Pump to be proved for satisfactory performance. (b) Check and flush all tube work, suction and delivery piping. (c) Renew all mountings, if any sign of deterioration of rubber, lacquer of bond.(Service code-EA3030)
Both pump suction and discharge pressure gauges to be calibrated/renewed. Gauge pipe line with isolating cock also to be renewed. (Qty- 04 nos.)(Service code-EB3031)
SHOWER BILGE PUMP (MAKE- M/S ROYSONS ENGINEERING PVT. LTD., KOLKATA, MODEL- N32, CAPACITY- 02 TPH), QTY- 02 NOS.
Following jobs to be carried out as part of refit routine of shower bilge pump:- (a) Dismantle the pump completely, clean and inspect each item thoroughly and renew as necessary. (b) Check and flush all tube work and suction and delivery piping. (c) Renew all mountings showing any sign deterioration of rubber, lacquer of bond. (d) Carry out calibration/ renew all pressure gauges (Qty- 04 nos.) (e) Recalibrate all the instruments connected to the pumps.(Service code-EA3032)
FM-200 MAJOR FIRE EXTINGUISHING SYSTEM (MAKE- M/S TYCO MARINE SERVICES, THANE (W)) , QTY- 03 NOS.
(a) Check N2 cylinder weight. Recharge nitrogen, if loss of weight observed more than 10%. Qty-06 nos. (b) Blow out distribution piping by nitrogen (c) Check FM-200 cylinder weight and pressures, Recharge FM-200 gas, if loss of weight observed more than 10%. Qty- 03 nos.(Service code-EA3033)
FUEL OIL PURIFIER (MAKE- M/S ALFA LEVEL, INDIA, PUNE, MODEL- NMOPX 306 +DCU41X), QTY- 01 NO., PAC FIRM – M/S ALFA LAVAL INDIA, PUNE
03 yearly service of completed separator to be carried out as per OEM/ PAC firm.(Service code-EA3034)
25 HP OBM FOR GEMINI (MAKE- M/S MERCURY MARINE), QTY- 01 NO., PAC FIRM- M/S ESMARIO EXPORT ENTERPRISES, SECUNDERABAD
Following jobs to be carried out as part of refit routine of 25 HP OBM:- (a) Overhaul the engine. (b) Clean the feed tank and replace the flexible hoses, if required. (c) Replace water pump impeller.(Service code-EA3035)
40 HP OBM FOR RIB (MAKE- M/S MERCURY MARINE) QTY- 01 NO., PAC FIRM- M/S ESMARIO EXPORT ENTERPRISES, SECUNDERABAD
Following jobs to be carried out as part of refit routine of 40 HP OBM:- (a) Overhaul the engine (b) Inspect remote steering assembly and renew defective components. (c) Clean the feed tank and replace the flexible hoses if required. (d) Replace water pump impeller.(Service code-EA3036)
PORTABLE SUBMERSIBLE PUMPS (CAPACITY- 20 TPH) (MAKE- M/S KIRLOSKAR BROTHERS LTD , MODEL- DSP65/12), QTY- 02 NOS.
Following jobs to be carried out as part of refit routine of submersible pumps:- (a) Overhaul the pump and replace spares as required. (b) Paint pump casing internally and externally.(Service code-EA3037)
PORTABLE SUBMERSIBLE PUMPS (CAPACITY-10 TPH) (MAKE- M/S MODI SUMP PUMP LTD , MODEL- M120NM), QTY- 01 NO.
Following jobs to be carried out as part of refit routine of submersible pump:- (a) Overhaul the pump and replace spares as required. (b) Paint pump casing internally and externally.(Service code-EA3038)
PORTABLE LUB OIL PUMP (MAKE- M/S ROYSON ENGG, KOLKATA, MODEL: RGO-1), QTY- 01 NO.
Following jobs to be carried out as part of refit routine of portable lub oil pump:- (a) Overhaul the pump. (b) Check the alignment of the pump with motor.(Service code-EA3039)
HYDROPHORE TANK (MAKE- M/S BEST & CROMPTON, CHENNAI, CAPACITY- 200 LTRS), QTY- 01 NO.
Following jobs to be carried out as part of refit routine ofhydrophore tank:- (a) Chemically clean hydrophore tank. (b) Check and calibrate pressure gauges and pressure switches. (c) Repaint tank with approved paint scheme. (d) Carry out pressure test of hydrophore tank at 12 bar.(Service code-EA3040)
AIR RECEIVER (MAKE- M/S ELGI SAUER, CAPACITY- 650 LTRS), QTY- 02 NOS.
Following job to be carried out as part of refit routine of air receivers (Qty- 02 nos.):- (a) Overhaul the valves. Sl Valve Type Size (MM) Qty (nos.) Test Pressure (Bar) (i) Inlet Cock (Ball) 25 02 45 (ii) Outlet Cock (Ball) 25 02 45 (iii) Drain Cock (Ball) 25 02 45 (iv) Safety Valve (Diaphragm) 25 02 70.(Service code-EA3041)
ROTARY PUMPS (MAKE- M/S KIJEKA ENGRS, TYPE- KE 200), QTY- 05 NOS.
Following jobs to be carried out as part of refit routine of rotary pumps:- (a) Dismantle the pump completely, clean and inspect each item thoroughly and renew as necessary. (b) Check and flush all tube work and suction and delivery piping. (c) Renew all mounting showing any sign of deteriorated of rubber, lacquer of bond.(Service code-EA3043)
PORTABLE ELECTRIC PUMP (MAKE- M/S DELTA PD, CHENNAI, TYPE- DIG 70), QTY-01 NO.
Following jobs to be carried out as part of refit routine of portable electric pump:- (a) Dismantle the pump completely, clean and inspect each item thoroughly and renew as necessary. (b) Check and flush all tube work and suction and delivery piping. (c) Renew all mounting showing any sign of deteriorated of rubber, lacquer of bond. (Service code-EA3044)
SHAFTING (MAKE: M/S JAURE SHAFT LINES, JAURE SA, SPAIN, TYPE- LAMIDISC), QTY- 03 NOS.,PAC FIRM- M/S KONGSBERG PVT LTD, NAVI MUMBAI
Following jobs to be carried out as part of refit routine of shafting through OEM/ PAC firm:- (a) Check for any disc pack failure. If found failed, replace it and investigate the cause of failure. (b) Inspect the lami disc, coupling disc pack for any misalignment using stroboscopic method as enumerated in the user manual. (c) Check the cooper roller bearing for wear and renew the lubricating grease of all plummer blocks (Qty- 05 nos.) (d) Inspect the shaft for corrosion. Shaft to be polished off and apply anticorrosive paint and protector. (e) Carry out time operational checks all the shafting inflatable rubber seals. (f) Carry out calibration/ renewal of pressure gauges.(Service code-EA3045)
SYSTEM VALVES
Fuel oil system- Remove,overhaul and refit following valves in fuel oil filling, transfer and service system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) Test Pressure (a) 40 mm QSD Valve 04 06 kg/cm2 (b) 40 mm SDNR Storage tank filling valve 02 06 kg/cm2 (c) 40 mm Globe RU Tank Filling 02 06 kg/cm2(Service code-EA3046)
Firemain system- Remove, overhaul and refit bilge and fire main system valves as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) Test Pressure (a) 65 mm SDNR Fire pump discharge overboard 01 09 kg/cm2 (b) 65 mm SDNR Fire pump discharge to firemain 01 09 kg/cm2 (c) 50 mm SDNR Fire hydrant 08 7.5 kg/cm2 (d) 65 mm SDNR Isolating cock 02 09 kg/cm2 (e) 65 mm SDNR Sprinkling system 02 09 kg/cm2 (Service code-EA3047)
Bilge pump system- Remove, overhaul and refit bilge pump system valves as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) Test Pressure (a) 65 mm SDNR Bilge pump discharge overboard 01 09 kg/cm2 (b) 65 mm SDNR Bilge pump discharge to fire main 01 09 kg/cm2 (c) 65 mm SDNR Bilge suction forepeak tank 01 05 kg/cm2 (d) 65 mm SDNR Bilge suction magazine 01 05 kg/cm2 (e) 65 mm SDNR Bilge suction void space 01 05 kg/cm2 (f) 65 MM SDNR Bilge suction FER 02 05 kg/cm2 (g) 65 mm SDNR Eductorsuction 03 05 kg/cm2(Service code-EA3048)
Fresh water system- Remove, overhaul and following valves in domestic fresh water filling and service system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) Test Pressure (a) 25 mm SDNR Hydrophoredischarge valve 01 06 kg/cm2 (b) 25 mm NRV Suction line near tank 01 06 kg/cm2 (c) 25 mm NRV Pump discharge 02 06 kg/cm2 (d) 25 mm NRV Suction valve 02 06 kg/cm2(Service code-EA3049)
Air system- Remove, overhaul and following valves in air system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) Test Pressure (a) 25 mm Globe Hydrophoreair discharge valve 01 7.5 kg/cm2 (b) 25 mm Globe Air bottle drain 02 45 kg/cm2 (c) 25 mm Globe Bottle inlet 02 45 kg/cm2 (d) 25 mm Globe Bottle outlet 02 45 kg/cm2 (e) Relief Valve Relief valve for air bottle 02 45 kg/cm2 (f) 25 mm Globe Air supply valve 05 10 kg/cm2 (g) 25 mm Globe Air siren valve 01 7.5 kg/cm2 (h) 25 mm Globe Air starting valve 03 40 kg/cm2(Service code-EA3050)
Emergency sea water system- Remove, overhaul and refit following valves of emergency sea water cooling system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) Test Pressure (a) 40 mm SDNR Gear box cooling system 03 06 kg/cm2 (b) 40 mm SDNR DA cooling system 03 06 kg/cm2(Service code-EA3051)
Lub oil system- Remove, overhaul and refit following valves of lub oil system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) Test Pressure (a) 25 MM Rotary Luboil system 03 05 kg/cm2 (Service code-EA3052)
Grey water tank system- Remove, overhaul and refit following valves of grey water tank pumping out system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Type Valve Description Qty (nos.) (a) 65 mm SDNR Pump suction float 01 (b) 65 mm SDNR Pump discharge overboard 01 (c) 40 mm SDNR Suction valve 02 (d) 40 mm SDNR Discharge valve 02(Service code-EA3053)
SYSTEM PIPELINES
Main engine sea water system- Remove, chemically clean, pressure test and refit following pipe lines of main engine sea water system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 05 inch dia/ CuNi Main engine 25 05 kg/cm2 (b) 02 inch dia/ CuNi Gear box 24 05 kg/cm2 (c) 02 inch dia/ CuNi Exhaust cooling 15 05 kg/cm2 (d) 01 inch dia/ CuNi Shaft cooling 40 03kg/cm2 (Service code-EA3054)
DA sea water system- Remove, chemically clean, pressure test and refit following pipe lines of DA sea water system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 2.5 inch dia/ CuNi DA 14 05 kg/cm2 (b) 02 inch dia/ CuNi Emergency cooling 14 06kg/cm2(Service code-EA3055)
AC plant sea water system- Remove, chemically clean, pressure test and refit following pipe lines of AC plant sea water system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 03 inch dia / Cu Ni AC plant 25 05 kg/cm2 (b) 2.5 inch dia / Cu Ni Emergency cooling 12 06kg/cm2(Service code-3056)
Fire main &eductor sea water system- Remove, chemically clean, pressure test and refit following pipe lines sea water system as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 03 inch dia/ CuNi Fire main 40 07 kg/cm2 (b) 03 inch dia/ CuNi Eductor 40 05 kg/cm2 (c) 03 inch dia/ CuNi Bilge system 60 05 kg/cm2(Service code-EA3057)
Air system- Remove, chemically clean, pressure test and refit following pipe lines as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (Mtrs) Test Pressure (a) 02 inch dia/MS Air system 15 45 kg/cm2 (b) 1.5 inch dia/MS Air system 20 45 kg/cm2 (c) 01 inch dia/MS Air system 20 45 kg/cm2(Service code-EA3058)
RO plant sea water system: Remove, chemically clean, pressure test and refit following pipe lines as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 02 inch dia/ CuNi RO plant 10 07 kg/cm2(Service code-EA3059)
Main engine fuel system: Remove, chemically clean, pressure test and refit following pipe lines as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 1.5 inch dia/ MS Fuel system 10 07 kg/cm2(Service code-EA3060)
DA fuel system: Remove, chemically clean, pressure test and refit following pipe lines as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 01 inch dia/ MS Fuel system 10 07 kg/cm2(Service code-EA3061)
Domestic fresh water system: Remove, chemically clean, pressure test and refit following pipe lines as mentioned below (only 50% projected as per maintenance schedule) Sl Size/Material System Qty (mtrs) Test Pressure (a) 01 inch dia/ CuNi Fresh water system 10 07 kg/cm2 (b) ¾ inch dia/ CuNi Fresh water system 10 0 kg/cm2(Service code-EA3062)
BILGE EDUCTORS
Remove, chemically clean and refit 03 in nos. bilge eductors(Service code-EA3063)
Following routine on air reducer to be carried out:- (a) 30/7 bar air reducer to be overhauled and diaphragm to be renewed. (b) 7/5 bar air reducer to be overhauled and diaphragm to be renewed. (c) 02 in nos. moisture cum air filter to be overhauled.(Service code-EA3064)
DIESEL ALTERNATORS (MAKE- M/S KIRLOSKAR OIL ENGINES LTD., MODEL- 6SL9088TA), OEM/ PAC FIRM- M/S KIRLOSKAR OIL ENGINES LTD.
10000 hourly of 03 in nos. diesel alternators to be carried out as per OEM maintenance schedule. Spares : CG Supply.(Service code-EA3065)
MISCELLANEOUS
Noise & Vibration analysis to be carried out on the following machineries during pre & post refit trials. A comprehensive analysis report along with remedial measures to be submitted. (a) Main engines- 03 nos. (b) Diesel alternator - 03 nos. (c) RO plant - 01 no. (d) AC compressor - 02 nos. (e) AC condenser pump - 02 nos. (f) HP air compressor - 02 nos. (g) Bilge & GS pump - 01 no. (h) Fire & GS Pump- 01 no. (j) AHU - 01 no. (k) Water jet unit - 03 nos. (l) Steering gear pumps - 03 nos. (m) Shafting (plummer block) - 05 nos. (n) Fresh water pumps - 02 nos. (p) Shower and bilge pump - 02 nos.(Service code-EB3066)
Following sea chest strainers to be renewed. (Mat- ) Sl Size System Qty (nos.) Length (a) 150 mm Main engine 03 400 mm (b) 65 mm DA 03 250 mm (c) 65 mm GS Pump 02 300 mm (d) 125 mm AC sea water pump 01 400 mm.(Service code-EB3067)
Pin hole observed near flange of fire main line passing through deck head in FER. Same to be removed, repaired and pressure tested for satisfactory performance. (Length- 02 Feet, Dia- 65mm, Material- Cu Ni ).(Service code-EB3068)
Flexible/ rubber hoses for main engine and gear box sea water cooling lines to be renewed as per sample. (Length- 01 Mtrs, Dia- 30mm, Pressure holding capacity- 05 Bar , Qty- 09 Nos ).(Service code-EB3069)
Quick shut off valves wires not operating smoothly. Wire to be renewed as per sample. In way job renewal wire pulley. Wire-Dia-08mm, Mat- SS, Wire Length- 30 Mtrs, Pulley Qty- 18 Nos, Pulley dia- 65mm).(Service code-EB3070)
Chequer plates (approx. area- 20 sqm, thickness- 05 mm, material- Al) and supporting frames/ angles (length- 30 mtrs, material- Al, thickness- 03mm, angle size- 40mm x 40mm) in FER, AER, and WJ compartments deteriorated. Same to be renewed.(Service code-EB3071)
HOMA ENGINEERING WORKS
ULTRA MARINE
YEOMAN MARINE SERVICES PVT. LTD.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Restricted Tender
This is a Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .