Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹50.5 L+₹95,047 (1.92%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 3 | L3₹65.9 L+₹16.4 L (33.1%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 4 | L4₹69.1 L+₹19.6 L (39.6%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L4 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KOTA
DADWARA KOTA RAJASTHAN 324002
SPL REPAIR TO BLOCK NO P-294 (01 TO 04) OR MD ACCN AT GTC LINE AND BLDG NO P-06 OF SUTC-I AND SUTC-II AT ABHERA FOR CERTAIN UNITS AT MIL STN KOTA
2024_MES_663503_1
8845E8
Open Tender
Civil Works
Item Rate
183 days
GE KOTA
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE KOTA
₹96,000
Yes
26 Oct 2024
2 Jul 2024
11 Sept 2024
2 Jul 2024
4 Sept 2024
16 Jul 2024
Amount
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Demolition/Dismantling of existing roof treatment, any type from RCC roof slab including lime concrete/PCC padding over roof, removing layer of bitumen under lime concrete/PCC padding, cement mortar, felt etc and cleaning the surface by hacking to receive plaster and removing demolished materials outside MD land, complete all as specified and directed.
Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in lime or mud mortar; not previously plastered; and scrubbing down with water etc. to receive plaster, complete all as specified and directed.
Taking down chowkhat or frames not exc 1.50 Sqm each with shutters (with out taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat or frames exc 1.50 Sqm and not exc 4.00 Sqm each with shutters (with out taking off shutters from the frame), complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each and removing from site complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm & n. exc 2 Sqm each and refixing in same opening after easing and resecuring/adjusting of shutter including renewal of screws etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and pavings n.exc 15 cm thickness (below or above GL) and removing rubbish from premises, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removing rubbish from premises, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Dismantling floor, hearth or wall tiling/ terrazzo including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors etc, laid, bedded and pointed in any mortar, complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles, complete all as specified and directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position framed work, complete all as specified and directed.
Dismantling timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section, in any position unframed work, complete all as specified and directed.
M&L brick work with old size pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:4, including finishing the joint, flush as the work proceeds complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggreate), 50 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where dirtected and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
M&L brushing neat cement slurry with 3.00 kg cement per Sqm, complete all as specified and directed.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in roof kerbs or mud stops,padding, rounded or chamfered on edges complete all as specified and as directed.
M&L for applying 20 mm thick screed in CM 1:3 on roof slabs with using liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed. (Liquid WPC shall be measured and paid separately).
M&L for applying 10 mm thick rendering on fair faces of roof slab in CM 1:3 with using liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed. (Liquid WPC shall be measured and paid separately).
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates.
Supply only approved liquid water proofing compound, complete all as specified and directed.
M&L for cleaning of walls and floor of sunken portions including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS: 3384 @ 0.40 Kg/Sqm, torching overlaps with a propane or a butane gas torch with an overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold applied bituminous primer all as per manufacturer’s instructions, complete all as directed. Note: (i) The waterproofing treatment shall be got carried out through the manufacturer or their authorized applicators only.
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as applicable to item 08095 given in SSR Part – II (2020).
S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part–II.
M&L for 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings, complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated as per IS-401, complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) glazed and skeleton, open rebated, prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered and rounded, fitted with cut and mitered beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F glass/gauge shall be measured and paid for separately.
S&F in renewal of 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, fixed as in cup boards, rebated or flat edged, incl necessary frame work & including 6mm thick external teak wood lipping, fixed to block or veneered particle board with nails complete all as specified and directed.
S & F in renewal continuous (piano) hinges, stainless steel, matt or brush finish, width of flaps (when open) in 40mm complete all as specified and directed.
S&F 125 mm hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
S&Fof ball catches with 8 mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified and dirceted.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium frame for doors, windows, ventilators & partition etc., with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M & L for Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium window and ventilator shutters, sliding/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.). hinges type B-21 100 mm long (2 No.) suitable handle (1 No.) complete all as specified and as directed.
Supply and fix Aluminium deco grill Cat No DG-104, 10 mm thick ,cut to required size/shape and fixed in position with and including stranded aluminium frame of F section of size 23.04x15.3x1.4mm thick all as per manufacturer instructions complete all as specified and as directed.
Supply only 4mm thick, black tinted sheet glass, ordinary quality, cut to size as required at site, incl fixed with necessary rubber gasket, complete all as specified and directed. (Cost of fixing of glass shall be deemed included in the unit rates under respective items.)
Supply only stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or SS wire staples complete all as specified and directed. (Note: cost of fixing of wire cloth shall be deemed included in the unit rates under respective items.)
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor, overall length of cover plate 150 mm, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed, complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size, complete all as specified and directed.
S&F aluminium handles, cast type, anodised 100 mm size, complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws, complete all as specified and directed.
S & F 300 mm long aluminium alloy, anodised sliding door bolts (ISI marked) with bolt not less than 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed complete all as specified and directed.
S&F in renewal of factory made pressed steel cupboard shutters alongwith frame, frame made of 1.25 mm thick PBI sheet and shutter made of 1.00 mm thick PBI sheet with 6 Nos 3.15 mm thick and 100 mm long steel hinges per shutter, godrej pattern locking arrangement with 12 mm dia vertical rod and lock with duplicate key & chrome finish handle, duly spray painted in factory with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer, complete with fastener, hold fast etc as required at site, complete all as specified and directed. (Total width including frame shall be measured for payment purpose).
S&F factory made steel windows conforming to IS-1038 with side hung shutters & including projecting type hinges, with 2 Nos steel handles, 2 Nos tower bolts & steel pag stay complete (with glazing bars), dovetailed or welded & including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed. Note :- Glass shall be measured and paid for sepparately under respective items.
S&F factory made steel windows conforming to IS-1038 with side hung shutters & including projecting type hinges, with 2 Nos steel handles, 2 Nos tower bolts & steel pag stay complete (without glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed. Note :- SS or MS cloth wire shall be measured and paid for sepparately under respective items.
S&F sheet glass 3 mm thick ordinary quality and glazing with oil putty etc in squares n.exe 0.50 Sqm in each pane, complete all as specified and directed.
S & F of stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or SS wire staples complete all as specified and directed.
S&F in renewal of stainless steel tubular curtain rods, 25 mm dia, with fixing brackets and one pair of decorative end caps etc, complete all as specified and directed.
S & F of framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fittings (excluding of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing, conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors: ladders: cages, frame balusters: walk ways: railing: frame work of water tanks and similar works conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F rolled mild steel work as in joist, channel, angle, or MS tube medium grade or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) using Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed.
S&F rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. using Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed.
S&F of anodised aluminium snap grid of size 600mm x 600mm frame work for false ceiling and including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F of 4mm thick high pressure steam cured (HPSC) non asbestos fibre cement building boards fixed in ceiling flat or slopingor laid/ inserted to timber/GI/Alumi nium framework with screws, complete all as per manufacturer’s instructions, all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D-2, using 40 mm graded crushed stone aggregate, as in sub base of floors, etc., finished surface even & fair to receive floor finishes/ screed complete all as specified and directed.
M&L Machine pressed precast conctete interlocking paver block any shape and size made with grey cement and pigment, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, laid over and including 25 mm thick sand cushion, complete all as specified and directed.
M&L precast (factory casted) cement concrete kerb stone casted in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with plain or interlocking joints (as directed) including making groove in ground of desired dimension, including weathering, slightly rounded or chamfered angles, placing in position, set and jointed in CM 1:4, making good distrubed surface of ground complete all as specified and directed.
M&L for 40mm thick plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in flooring /sub base finished surface even & fair to receive floor finishes/ screed complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 18 to 20 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and mirror polishing by applying wax polish, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for machine cut kota stone slab as in skirting, dado, risers etc, 18 to 20 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and mirror polishing by applying wax polish, laid over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm fixed on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
M&L black granite (of any type) slab 18-20 mm thick, table rubbed and mirror polished by applying wax polish as in cooking platform, jambs, cills, pillars, tread, risers, platform for WHB etc including bull nosing to exposed outer edges, set in CM 1:4 bedding and pointing with white cement mixed with pigment and provn of hole for gas pipe, laid over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed. Note :- Granite stone slab shall be laid in single piece with rounding of edges and a grove shall be provided beneath the projection portions of slab.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) mixed with water proofing compound as per manufacturer instructions in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. Note :- Liquid WPC shall be measured and paid separately.
M&L for rendering 15 mm thick on stone masonry surfaces or other than fair faces of brick work in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of ceiling in cement mortar 1:3 including finishing the surface even and smooth, complete all as specified and directed.
M&L for preparing new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L applying 2 coats of synthetic enamel paint over and including a coat of pink primer on wooden surfaces, exceeding 10 cm in width or girth, incl preparation of the new surfaces complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over & including a coat of chalk whitening, complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over & including a coat of chalk whitening, complete all as specified and directed.
M&L for complete removal of existing treatment from previously treated plastered/unplastered surfaces of walls and applying two coats of distemper oil emulsion over & including a coat of suitable primer, complete all as specified and directed.
M&L for complete removal of existing treatment from previously treated plastered/unplastered surfaces of walls and applying two coats of cement base paint over & including a coat of suitable primer, complete all as specified and directed.
M&L for applying three coats of white wash on ceiling/false ceilings including preparation of new or previously untreated surfaces, complete all as specified and directed.
M&L for applying one coat of white wash after preparation of old previously treated plastered surfaces of ceiling, complete all as specified and directed.
S&F in renewal of HDPE PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts and rubber washers complete all as specified and directed.
S&F in renewal of vitreous china wash hand basin white with flat back of size 550x400 mm, excluding chain and plug, taps and porcelain stopper but incl PVC waste pipe of 32 mm bore, suitable size of waste fittings, one pair of 600 mm long cast iron brackets, complete all as specified and directed.
S&F in renewal of chromium plated over head shower 125mm size square shape single flow (ABS body chromium plated with gray face plate) with rubit cleaning system, complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 15 mm bore pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 20 mm bore pipes complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) for 20 mm dia pipes with and including all new fittings complete all as specified and directed.
Supply, fixing, laying & testing 15 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Supply, fixing, laying & testing 20 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Supply, fixing, laying & testing 50 mm bore low density polyet hylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed to walls, ceilings or in floors etc, complete all as specified and directed.
Dismantling existing water storage tank of any description of capacity exc. 250 ltr but n.exc. 500 ltr, complete all as specified and directed.
S&F in position rotational moulded polyethylene water storage tanks 500 lts capacity, white colour (cylinderical vertical with closed top) hoisted and fixed in position, complete all as specified in SSR Part I and as directed. Note:- PVC tank shall be ISI marked and having three layers.
S&F ball valve 20 mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and directed.
S & F in renewal of 15mm bore two way angle valve chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed with necessary fitting complete all as specified and directed. Make :- CERA cat part No G1017211 / Hindware cat part no F 740006 / Johnson cat part no JT 1643A or techno commercially equivalent Make specified in PS
S & F in renewal of Bib taps 15mm dia, chromium plated, long body, with CP flange all as per fixed in repairs complete all as specified and as directed. Make :- CERA cat part No G 1017152 /Jaquar cat pat no VGP-81037/ Hindware cat part No F 740011 or techno commercially equivalent makes specified in PS.
S & F pillar taps, 15mm dia, long body/swan neck, fancy type suitable for fixing to wash basin screwed for iron pipe and fixed with necessary fittings and including PVC connection complete all as specified and as directed. Make :- CERA Cat Part No F1003103 / Jaquar cat Part No COP -021PM/ Hindware Cat Part No F 740002 or techno commercially equivalent makes specified in PS.
S&F in renewal of vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest, P or S trap, incl providing lime concrete bedding and connecting to flusing cistern, complete all as specified and directed.
S&F in renewal of 10 Ltr capacity PVC low level flushing cistern, top push type with inlet ball valve, PVC float, brackets & including superior quality PVC flush pipe of 32 mm dia, complete all as specified and directed.
S&F in renewal of sink with draining board made of stainless steel 1mm thick with plugs, washers and including 32mm CP waste coupling, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets of suitable angle iron, 32 mm dia superior quality PVC waste pipe and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in renewal of stainless steel kitchen plate rack of size 1200x900x180 mm, made of 0.80 mm thick stainless steel sheet with partition for small /large plates and fixed in position, design and pattern as approved by the GE, complete all as specified and directed.
S&F in renewal of 'D' type tubular towel rail 60 cm long, brass chromium plated, 20 mm dia, complete fixed with stainless steel screws, complete all as specified and directed.
S&F in renewal of PVC (SWR) 75 mm dia floor trap, with CP grating including jointing to waste pipe and fixed in cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed.
S&F in renewal of PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints laid in trenches or in floor and including dismantling of old u/s existing pipes alongwith fittings and accessories complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints laid in trenches or in floor and including dismantling of old u/s existing pipes alongwith fittings and accessories complete all as specified and directed.
S&F PVC (SWR) bend 75 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) bend 110 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) 75 mm bore branch piece, single (single Y) equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) 110 mm bore branch piece, single (single Y) equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) vent cowl 110 mm dia, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm dia, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in hard soil, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in soft/disintegrated rock, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in hard rock, complete all as specified and directed.
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down submain wiring including conduit and UG XLPE cable of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLSH) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLSH) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including providing wooden rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces, complete all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps. Note :- Cutting chases (if required) and making good to match with the adjoining surface shall be included in the unit quoted rate.
All as per item No 124.00 (here-in-before) but one 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
All as per item No 124.00 (here-in-before) but one 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
M&L Point wiring with PVC insulated (FRLSH) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLSH) unsheathed multi stranded copper conductor cable FRLSH of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including providing wooden/PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surface, complete all as specified and directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, five pin, flush type universal, complete all as specified and directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, ISI marked complete all as specified & directed.
S&F in renewal of stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 50mm, 3 terminals, complete all as specified & directed.
S&F bell push, flush type, single pole, AC, 240 volts, 5/6 amps, iSI marked, complete all as specified and directed.
S&F in renewal of Bell, AC, 230 volts, single pole, complete all as specified and directed.
S&F in renewal of wall mounted 20 watt LED Tube light fittings, batten type with bipin holders, powder coated steel with internally prewired, complete all as specified and directed.
S&F in renewal of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
M & L in renewal of street/road light GI mounting bracket made out of steel tube, medium grade, 32 mm dia (or higher size to suit the opening of the fitting) 0.550 mtr long by hydraulic pressed mechine bend to require arc shape and fixed to pole with 02 Nos MS flat iron clamps of suitable size fixed with bolts, nuts and washers including drilling holes and grouting with the same for fixing bolts as required & incl duly painted with two coat of aluminum paint over a coat of aluminum red oxide primer and fixing with lights fittings on the existing old street light poles complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for renewal of mounting brackets, light fittings, nuts, bolts etc shall be deemed to be included in the unit rate quoted.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'C' curve including all accessories, complete all as specified and directed.
S&F MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'C' curve including all accessories, complete all as specified and directed.
S & F MCB FP 40-100 Amps, 415 volts, four pole, C-curve, rupturing capacity 16KA conforming to IS-8828-1996, IEC-60898, complete all as specified & directed by Engineer-in- charge.
S&F in renewal of single pole and neutral enclosure with a two pin and earth plug and socket, complete with & including one SP, MCB of 20 Amps, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, double door, complete all as specified and directed. Make :- Legrand Ekinox3 series/ Schnieder Easy9 series/ ABB Cat No : ISYP011608C0001 or techno commercially equivalent makes specified in PS.
S & F factory made MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, IP-43-IK09 protection grade, earth bar and Din rail, 415 Volts TPN with 4 ways, Double door, complete all as specified and directed. Make :- Legrand Ekinox3 series/ Schnieder Easy9 series/ ABB Cat No : ISYP021604C0001 or techno commercially equivalent makes specified in PS. Note for items of MCB DB - (1) The unit rate includes for cutting the brick/stone walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLSH multistranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded FRLSH copper conductor cable green colour as earth continuity conductor, complete all as specified & as directed. Note :- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4 dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in any type of soil/rock and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling and taking out old earthing complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
Supply and fixing in renewal of ceiling fans with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note :- (i) Length of rod of suitable length upto 3 meter or as per site requirment and its cost shall be deemed to be included in the quoted rate. (ii) Taking down carefully old u/s existing ceiling fan and deposit to MES store.
Supplying, laying, jointing testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade of cross-sectional area 16 Sqmm, 4 core, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall, complete all as specified and directed.
Supplying, laying, jointing testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade of cross-sectional area 16 Sqmm, 2 core, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall, complete all as specified and directed.
M&L dry clean river sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. Note: - Depth of sand shall be measured after punning.
Supplying and laying pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), laid flat adjoining each other as in protection to UG cables, complete all as specified and directed.
M&L in renewal of 40 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
Cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line/conduit, making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type B1 complete all as specified and directed.
S&F in renewal of exhaust fan, steel body AC single Phase. 230V of size 300mm, sweep with, blades, and frame and louvers & including connecting with and including PVC insulated three core 23/.0076 copper conductor cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high and including making appropriate hole in the wall/ window complete all as specified and directed. Note :- Taking down carefully old u/s existing exhaust fan and deposit to MES store.
Supply and fixing in renewal of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250mm and including PVC insulated three core 23/.0076 copper conductor cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high and including making appropriate hole in the wall/ window complete all as specified and directed. Note :- Taking down carefully old u/s existing exhaust fan and deposit to MES store.
Supply and fixing in renewal of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. Note :- Taking down carefully old u/s existing geyser and deposit to MES store.
ALFA BUILDERS AND CONSTRUCTION COMPANY (BID ID -3070950)
L P Singh and Co. (BID ID -3069957)
Aditya Enterprises (BID ID -3070184)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .