Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC C 23 CC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹8.3 L+₹1.4 L (20.1%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest |
Tender Value
₹7.3 L
EMD Value
₹14,700
Closing Date
2 Mar 2022, 6:00 pmClosed
AGE(I) Raiwala
AGE(I) Raiwala
SPL REPAIR TO INSTUMENTAL AND TELECOM SHOP BLDG NO P 137 OF 306 FD REGIMENT AT RAIWALA MIL STN
2022_MES_505743_1
8882/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I Raiwala
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE(I) Raiwala
₹14,700
Yes
17 Mar 2022
4 Feb 2022
4 Mar 2022
4 Feb 2022
2 Mar 2022
18 Feb 2022
4 Feb 2022 - 11 Feb 2022
Amount
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar/concrete any type and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for Single storey . The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.
M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (as per manufacture direction and paid separately) over and incl one coat of cement slurry admixed with & including acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction and finishing the surface even and smooth(without using extra cement) as in roof padding to receive water proofing treatment complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for Single storey . The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note:- 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for Single storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) ,complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 as in ceiling finished even and smooth (without using extra cement) complete all as specified and as directed
M&L for white washing three coats on ceiling incl preparation of newly plastered surface.complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls external surfaces in two layerss first layer of 10 mm in CM 1:6 & 2nd layer of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth without using extra cement complete all as specified and directed. Note:- Integral water proofing liquid will be measured and paid seperately under relevent item of Sch A.
Supply only Integral liquid water proofing compund ISI Marked as approved complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iii). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (iv). The colour / shade will be all as approved by GE / AGE (I) (v) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
Roughening surface of old concrete floor by tucking, picking, sweeping clean and washing down with water to remove dust,etc to receive the screed layer for laying floor tile complete all as specified & directed.
M & L 18-20 mm thick machine cut kota stone slab flooring over cement screed base laid and incl 20 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing (mirror polished) complete all as specified and directed.
M & L for 16-18 mm thick machine cut pre polished kota stone slab as in riser of steps, skirting/dado laid over and incl 10 mm thick rendering of CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each and removing from site complete all as specified & directed.
S&F 125 mm x 65 mm Double Rebate Factory made 100% Solid WPC door Frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg / Cum & Manufactured by an ISO:9001-2015 certified company, all as per specification drawing as directed by the Engineer-In-Charge.The door frame should be Water proof, Termite proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
S&F 100 mm x 65 mm Single Rebate Factory made 100% Solid WPC door Frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg / Cum & Manufactured by an ISO:9001-2015 certified company, all as per specification drawing as directed by the Engineer-In-Charge.The door frame should be Water proof, Termite proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
M&L 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
M&L 30mm thick Factory made moulded coloured 100 % solid door (confirming As per IS 4020) made from 100 % lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600 kg/cum. manufactured by an ISO: 9001-2015 certified company. The door should be water proof, termite proof , fire retardent and having screw holding capasity.complete as per direction of Engineer-in-charge, manufacturer's specification and drawing complete all as specified & directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
S&F Aluminium anodized barrel tower bolt of size 12mm dia and 250 mm length of extruded section (ISI Marked) complete all as specified and directed.
S&F Extruded Aluminium alloy handles,fabricated type, anodised 150 mm long, (ISI Marked) complete all as specified and directed.
S& F Aluminium alloy anodised sliding door bolt, of size 16 mm dia and 300mm length, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy (ISI Marked) complete all as specified and directed.
S&F 100 mm long extruded Aluminium alloy anodised butt hinges with galvanized mild steel hinge pin type C 21 (ISI Marked) complete all as specified and directed.
S&F Floor door stopper (ISI Marked) of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm complete all as specified and directed.
S&F aluminium door seal upto 1200 mm long on bottom of door complete all as specified and directed.
S&F aluminium hat pegs, solid body, 125 mm to 175 mm complete all as specified and directed.
Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. . Windows to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001 iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad , Ph-9891542779
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade Fe-410 gde st- 240 complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10cm width & girth not otherwise described and applying two coat of synthetic enamel paint Ist quality over a coat of red oxid primer complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 73 mm wide inserted in position complete all as specified and directed.
Surface dressing in any type of soil n.exc 15 cm deep complete all as specified and directed.
M&L 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone Aggregate) as foundation/Sub-base of flooring complete all as specified and directed.
M&L for Prepolished chequered cement concrete tiles 300X300X25 mm thick, rubber finished (ISI marked), as in floors laid over 20 mm thick screed bed in cement mortar 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the tiles including removal of old materials from site not exceeding 100 meter, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, with fitting such as swiches, ceilng roses, pendants, regulators, sockets etc for taking credit (Credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point/Exhaust fan point, controlled by one no one way 5 Amp switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed non metallic rigid PVC conduit,medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk mild steel/pressed steel Metal flush box thickness not less than 1.6mm painted with black bituminus paint from out side and two coat aluminium paint inside for housing switches, sockets , fan regulators etc covered with 2.80 mm thick white laminated 'Bakelite' sheet (ISI Marked) cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item no-40 above but one 5 pin 5/6 Amps socket outlet point on same board controlled by one no of one way switch single pole 5/6 Amps complete all as specified and directed.
All as per item No 40 above but with 2.5 Sq mm PVC insulated multistranded copper conductor cable FRLSH including 2.5 Sq mm PVC insulated copper cable FRLSH as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
S&F switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked complete all as specified and directed. Make:- Cat part no HSN8536/14111 OF Anchor or HSN 8536/7001 of Cona or Havells Reo Cat Part No-AHESXXW061
S&F switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way complete all as specified and directed.Make:-Cat part no HSN8536/33118 of Anchor or HSN 8536/7081 0f Cona or Havells Reo Cat Part No-AHESXXW201
S&F socket out let 3/5 pin 5/6 Amps flush type complete all as specified and directed. Make:- Cat part no HSN8536/14302 of Anchor, HSN 8536/7021 of cona or Havells Reo Cat Part No-AHEKP01W063
S&F socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC ISI marked complete all as specified and directed. Make:- Cat part no HSN8536/145045 of Anchor, HSN8536/7081 of cona or Havells Reo Cat Part No-AHEKUXW063
Supply and fixing ceiling rose surface bakelite 65/25 mm dia 220/240 volts having three terminals ISI Marked complete all as specified & directed.
S&F in repair LED tube light batten 20 watts 4 fts polycarbonate housing, translucent diffuser with LED light source , 2200 lumen, natural white ,surge protection range 2KV, voltage protection range 120-280 VAC , 2 years warranty ,system efficacy not less than 110 Lm/watt for the fitting , power factor>0.95 total harmonic distortation<20% , colour rendering index >80, coefficient colour temp 6500 K, fixed on site with all accessories all as specified and directed. Note:- (i) the firm has to give warranty for light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 & LM 80 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRS (iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and the cost of the same is inclusive in above.
S&F in repair LED street/security light fitting 20W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts AC, 50 HZ, consisting of reflective lens wired with approximate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level > 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 120 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 K- 6500 K including fixed on wall with 02 Nos MS clamp made out of 40 x 6 mm F1 and bracket made out of 40 mm dia light grade GI pipe not less than 1.0 mtr long bend to shape with use reducer for inner dia 38 mm for fix with inside light fitting including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volta grade all as specified and as directed. Note :- (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 & LM 80 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRS (iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and the cost of the same is inclusive in above.
Fixing only ceiling fan 1200 mm sweep and making necessary electric connection with 1.50 sqmm PVC insulated flexible copper wire complete all as specified and directed . Note:- (i) The Ceiling fan shall be issued by the department under Sch B free for fixing. (ii) The PVC insulated flexible copper wire 1.50 Sqmm for connection from ceiling rose to ceiling fan shall be provided by the contractor & the cost of same is deemed to be included on the unit rate quoted by the contractor.
M & L in repair sheet metal MCB DB SPN 08 way 240 volts, double door type powder coated with 200 Amps rated bus bar, neutral link, earth rail & din rail, ISI marked for housing MCBs and making good for distrubed surface with existing etc complete all as specified and directed Note:- (i) MCBs measured and paid for separately under respective items. (ii) when PVC cables connected to MCBs use suitble size of copper connectors for connection and Incoming UG cable use suitable size of lugs for connect cable through MCBS on DB. The cost of the same shall deemed to be included in the unit rate quoted by the contractor.
S&F in repair MCB SPN 16-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB), ISI marked, 50 hz with cable connection and copper lugs complete all as specified and directed.
S&F in repair 10 KA 'B' curve miniature, circuit breaker (MCB) of single pole and current carrying capacity 2 to 5 AMP ISI marked, 230/240 volts, 50 Hz in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F in repair 10 KA 'B' curve miniature, circuit breaker (MCB) of single pole and current carrying capacity 5 to 10 AMP ISI marked, 230/240 volts, 50 Hz in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
S & F Batten PVC polycarbonate holder 230 V, ISI marked, suitable for fixing 9 Watt LED bulb complete all as specified and directed. Note:- The LED bulb 9 Watt shall be meaured & paid seprately under Sch A item no-56 here-in-after as supply only.
Supply only 9 Watt LED inverter bulb works on AC supply in normal mode and DC suypply in Inverter mode, with inbuilt battery back up of up to 4 hours, high efficency, high lumens output, options of B 22 base 5 star rated, ISI marked, 240 volts complete all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .