| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 Cr+₹2.2 L (1.58%)Rejected-Finance P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | ₹1.4 Cr+₹2.2 L (1.58%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹1.4 Cr+₹5.0 L (3.57%)Rejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹1.4 Cr+₹5.0 L (3.57%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹1.6 Cr+₹16.8 L (12.0%)Rejected-Finance 59 49 A BIRHANA ROAD KANPUR KANPUR NAGAR UTTAR PRADESH 208001 | KANPUR NAGAR | UTTAR PRADESH | 208001 | ₹1.6 Cr+₹16.8 L (12.0%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹1.6 Cr+₹18.7 L (13.4%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | ₹1.6 Cr+₹18.7 L (13.4%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
6 Jul 2022, 6:00 pmClosed
AGM EE EMD VIII
NEW OPERATIONAL BUILDING AAI NSCBI AIRPORT KOLKATA
Replacement of existing DG set with 500 KVA new DG set AMF Panels allied electrical works and Civil Works
2022_AAI_118456_1
AAC/EMD-VIII/PS-DG/2022-23
Open Tender
Electrical Works
Item Rate
180 days
NSCBI AIRPORT KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,120
₹3.6 L
25 Jul 2023
14 Jun 2022
8 Jul 2022
15 Jun 2022
6 Jul 2022
15 Jun 2022
15 Jun 2022 - 20 Jun 2022
Amount
Supply, Installation , testing & commissioning of 'Silent type DG set as per latest CPCB norms along with suitable prime mover having power rating suitable to deliver 500 KVA at site at 415V, 1500 RPM , 0.8 p.f. lagging for 50 Hz, 3 phase system and for 0.8 load factor as per specification enclosed and consisting of following confirming to specification attached and as directed by Engineer- in –charge. Diesel Engine: Diesel Engine 4 stroke, water cooled electric start, of suitable BHP (Main 587 BHP) at 1500 RPM suitable for delivering 500 KVA nominal capacity output..............accessories as per specification enclosed. Engine mounted control panel fitted with and having digital display for the following. Start stop switch with key. ....................... Engine running hours indication. Alternator Synchronous alternator suitable to deliver minimum 500 KVA , 415 V, 3 phase, 50 hz, AC supply with 0.8 lagging power factor at 40 degree celcius, 50% RH, and 1000m Mean sea Level (MSL). ............................, self regulated through AVR conforming to IS 4722/BS 2613 suitable for tropical condition and with insulation H class as per specification enclosed. Base frame and foundation. Both the engine and alternator shall be mounted on base frame made of suitable MS channel.............t concrete foundation and necessary vibration isolation arrangement as per the recommendations of the manufacturers. Day fuel tank. Daily service fuel tank of 990 ltrs capacity made out of minimum 3 mm thick MS sheet and complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipe of suitable dia complete with valves, level indication, fuel flow meter & accessories as required as per specifications. Exhaust System Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor and rain / bird guard. Starting System 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable capacity battery as per the recommendations of the manufacturer. Accoustic Enclosure Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. The accoustic enclosure shall meet the latest CPCB norms as aspplicable with update date amendment including WBPCB clearances and certification for consent to operate from CA etc. as required .
Supplying, fabrication and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, including painting (two coats of anticorrosive paint) etc., as required as per specifications. (a) Supply and making of MS black B class pipe 250 NB with heat resistive gaskets, flanges , bends & nuts bolts etc. as per site requirement.
Supplying, fabrication and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, including painting (two coats of anticorrosive paint) etc., as required as per specifications. (b) Supply and fixing of SS flexible bellows 250 NB and of suitable length complete with flanged Ends, heat resistive gaskets, nut bolts etc as per site requirement.
Supplying, fabrication and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, including painting (two coats of anticorrosive paint) etc., as required as per specifications. (c ) Supply and making of thermal insulation of 250 mm dia MS pipe with 50 mm thick mineral wool with wire mess 26 SWG Al cladding etc. as per site requirement.
Supplying, fabrication and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, including painting (two coats of anticorrosive paint) etc., as required as per specifications. (d) Supply and making of thermal insulation on silencer with 50 mm thick mineral wool , wire mesh provided with 26 SWG Al cladding as per site requirement.
Supplying, fabrication and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, including painting (two coats of anticorrosive paint) etc., as required as per specifications. (e) Supply and making of MS support structure for erection & supporting above pipe structure as per (a) etc. and as directed by Engineer-in-charge.
Supplying, fabrication and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, including painting (two coats of anticorrosive paint) etc., as required as per specifications. (f) Supply and making of Radiator hot air discharge ducting made out of GI sheet of 24 Gauge Thickness, angle, rivets etc. as per OEM recommendation.
Supply of following size power cables of 1.1 KV grade, XLPE Insulated PVC Sheathed aluminium conductor cable, armoured, and PVC sheathed conforming to IS 7098 Part-I and as specified. (a) 3.5 C X 300 Sq. mm
Supply of following size power cables of 1.1 KV grade, XLPE Insulated PVC Sheathed aluminium conductor cable, armoured, and PVC sheathed conforming to IS 7098 Part-I and as specified. (b) 3.5 C X 400 Sq. mm
Supply and laying of 1.1 KV PVC insulated copper conductor cables, round wire armoured construction and overall PVC sheathed cables in conformity with IS 1554 (Part-I)-1976 and amended upto date and as per Technical specification, in existing MS / Hume pipes / Masonry trench, of following size of approved make cable as required and directed. (a) 5C X 2.5 Sq. mm
Supply and laying of 1.1 KV PVC insulated copper conductor cables, round wire armoured construction and overall PVC sheathed cables in conformity with IS 1554 (Part-I)-1976 and amended upto date and as per Technical specification, in existing MS / Hume pipes / Masonry trench, of following size of approved make cable as required and directed. (b) 12C X 2.5 Sq. mm
Supply of wall mounting 750 mm sweep air circulator having speed of 1440 rpm and air delivery of 370 - 400 cmm complete with all accessories etc. as required.
Supply of wall mounting 600 mm sweep air circulator having speed of 1440 rpm and air delivery of 250 - 280 cmm complete with all accessories etc. as required.
Supply of single phase 2.5 HP, Dewatering Pump having protection of IP 68, Insulation F Class, Discharge range of upto 330 LPM with Head of 6 meter along with cable length of 9.5 mtrs. and PVC discharge pipe of 10 mtrs. length (Model: Eterna 1800BW) of Kirloskar make.
Providing, laying and fixing following dia GI pipe (medium class) in ground complete with GI fitting including trenching (75 cm deep) and re-filling etc. as required. a) 100 mm
Supplying and installing following size of Hot dip Galvanised / Powder coated ladder type cable trays in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. a) 300 mm wide X 50 mm wall height GI perforated type.
Supply & fixing 2.0 mm. (nominal + / - 10%) thick electric insulated PVC sheet along with suitable adhesive / chemibound, having minimum breakdown strength 68 KV, having no adverse effect of insulating oil, high insulation resistance and water proof i/c. material for water proofing of floor and sealing of all joints etc. suitable for voltage not exceeding 1.1 KV.
Supply, Fabrication & installation of 8 mm thick chequered plate duly painted two coats of anti-corrosive & for covering cable trench, with lifting hook and straightener / supports along with provision of MS angle iron structure in cable trench etc. inside the substation yard.
Supply and fixing of MS channel of following sizes of suitable lengths i/c grouting on the roof/wall, welding, painting with a coat of red lead primer etc. as required and as per direction of Engineer-in-Charge. (a) 75 x 40 x 4.4 mm
Supply and fixing of MS channel of following sizes of suitable lengths i/c grouting on the roof/wall, welding, painting with a coat of red lead primer etc. as required and as per direction of Engineer-in-Charge. (b) 100 x 50 x 4.7 mm
Supply and fixing of MS channel of following sizes of suitable lengths i/c grouting on the roof/wall, welding, painting with a coat of red lead primer etc. as required and as per direction of Engineer-in-Charge. (c) 125 x 65 x 5 mm
Supply and fixing of MS angle of following sizes i/c grouting on the roof/wall, welding, painting with a coat of red lead primer etc. as required and as per direction of Engineer-in-Charge. (a) 50 x 50 x 5 mm
Supply and fixing of MS angle of following sizes i/c grouting on the roof/wall, welding, painting with a coat of red lead primer etc. as required and as per direction of Engineer-in-Charge. (b) 75 x 75 x 5 mm
Dismantling of 437.5 KVA DG set along with AMF Panel, exhaust pipe including support structure & other accessories and shifting those to AAI store complete as directed by Engineer-in-Charge.
Earthing with medium class G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with Charcoal / Coke and salt as required.
Earthing with G. I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and proving masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and proving masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Providing & fixing 50 mm X 5 mm thick Cu. Strip in 80 mm dia GI (class - B) pipe from earth electrode etc. as required.
Providing & fixing 50 X 5 mm thick G.I. Strip in 80 mm dia GI (class - B) pipe from earth electrode etc. as required.
Providing & fixing 50 mm X 5 mm thick Cu. Strip on surface or in recess for connection etc. as required.
Providing & fixing 50 mm X 5 mm thick G.I. Strip on surface or in recess for connection etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Lettering of maximum 2" size (Alpha / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. (a) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. (b) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. (c) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. (a) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. (b) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. (c) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. (d) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (b) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (c) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (d) Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25 X 3 mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (c) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40 X 3 mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (d) Above 185 sq. mm and upto 400 sq. mm (clamped with 40 X 3 mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (a) upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25 X 3 mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (c) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40 X 3 mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (d) Above 185 sq. mm and upto 400 sq. mm (clamped with 40 X 3 mm MS flat clamp)
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in ground including excavation of soil and refilling the trench etc. as required. (a) Upto 35 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in ground including excavation of soil and refilling the trench etc. as required. (b) Above 35 sq. mm and upto 95 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in ground including excavation of soil and refilling the trench etc. as required. (c) Above 95 sq. mm and upto 185 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in ground including excavation of soil and refilling the trench etc. as required. (d) Above 185 sq. mm and upto 400 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/HDPE pipe as required. (a) Upto 35 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/HDPE pipe as required. (b) Above 35 sq. mm and upto 95 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/HDPE pipe as required. (c) Above 95 sq. mm and upto 185 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/HDPE pipe as required. (d) Above 185 sq. mm and upto 400 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a) Upto 35 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (b) Above 35 sq. mm and upto 95 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (c) Above 95 sq. mm and upto 185 sq. mm
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (d) Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3½ X 25 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (b) 3½ X 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (c) 3½ X 50 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (d) 3½ X 70 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (e) 3½ X 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (f) 3½ X 120 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (g) 3½ X 185 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (h) 3½ X 240 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 300 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (j) 3½ X 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (k) 4 X 16 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3½ X 25 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (b) 3½ X 35 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (c) 3½ X 50 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (d) 3½ X 70 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (e) 3½ X 95 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (f) 3½ X 185 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (g) 3½ X 240 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (h) 3½ X 300 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 400 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (j) 4 X 16 sq. mm
Excavation of the cable trenches in cement concrete not exceeding 1.5 metres in which, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Demolishing brickwork manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 mtrs. As per direction of Engineer-in-Charge.
Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement: 4 coarse sand) at all levels.
Providing and laying in position cement concrete 1:3:6 (1cement: 3 coarse sand: 6 grade stone aggregate 20 mm nominal size) etc. as required.
Providing 15 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Providing neat cement in the surrounding wall as well as on the floor as required.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for all heights: Foundations, footings, bases of columns, etc. for mass concrete
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand)
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement: 4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: "1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size).
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
12 mm cement plaster: 1:6 (1 cement: 6 fine sand)
15 mm cement plaster: 1:6 (1 cement: 6 fine sand)
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work.
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Fixing of dismantled rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover(rolling shutter provided by department (AAI) free of cost)
Youngmen Traders
Awasthi Electric Works
Choubay And Co.(Agencies) Pvt.Ltd.
Mona Generator Services Pvt. Ltd.
M/s J.K. Electric Engineering Works
POWER INDIA
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .