Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹8.8 L+₹83,330 (10.4%)Rejected-Finance EDALAKADU THABORE P O MOOKANNOOR ERNAKULAM DIST KERALA 683 577 | MOOKANNOOR | ERNAKULAM | KERALA | 683577 | L2 | Rejected-Finance L1 Being accepted | |
| 3 | L3₹9.9 L+₹1.9 L (23.6%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Rejected-Finance L1 Being accepted | |
| 4 | L4₹10.0 L+₹2.1 L (25.7%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L4 | Rejected-Finance L1 Being accepted | |
| 5 | Rejected-Technical 65 905 SEBASTIAN ROAD KALOOR KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | - | Rejected-Technical The bidder not submitted required documents to meet eligibility criteria for enlistment even after allowing sufficient time to submit the same. |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
12 Jan 2021, 6:00 pmClosed
GE (I) (CG) KOCHI
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
PROVISION OF INDEPENDENT EXTERNAL ELECTRIC CABLE AND TAMPER PROOF ENERGY METER FOR BUILDINGS AT CGRA AND ICGS BEYPORE FLAME PROOF LIGHT IN MAGAZINE ARMORY POL STORE AT ICGS BEYPORE AND PROVISION OF AIR CONDITIONER FOR SERVER ROOM AT CG RRT KOCHI
2020_MES_404190_1
8741/CG/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BEYPORE
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (I) (CG) KOCHI
₹19,000
Yes
3 Feb 2021
16 Dec 2020
13 Jan 2021
16 Dec 2020
12 Jan 2021
31 Dec 2020
16 Dec 2020 - 23 Dec 2020
Amount
Supply, Laying, testing and commissioning LT Cable 1100 Volt grade 3.5 core 35 Sqmm aluminium conductor, heavy duty with XLPE insulated screened PVC bedded galvanised steel strip or wire armoured or tape and over all PVC sheathed stranded conductor with suitable size of thimbling fixed in wall/floor or laying in trenches complete all as specified and as directed. Note: Excavation, earth work shall be measured and paid for separately.
All as per Item No. 1 above, but 3.5 core 50 Sqmm aluminium conductor complete all as specified and as directed.
All as per Item No. 1 above, but 3.5 core 70 Sqmm aluminium conductor complete all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying cable in soft/loose soil and getting out complete all as specified and as directed.
Returning, filling in soil including spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50m, and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply and Fix High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 40 mm bore complete all as specified and as directed.
Supply and Fix High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 50 mm bore complete all as specified and as directed.
Supply installing connecting, testing and commissioning of LT Panel board, 3 phase, 4 wire, 50 Hz, 433 volts, with insulted alumiinium bus bar 200 Amp, outdoor cubical type, dust and vermin proof, wall mounting type all prewired fabricated out of 3mm thick CRCA steel sheet duly pre treated and powder coated, factory fabricated panel with cable alley including cable glands of suitable sizes complete all as specified and directed comprising of following:- (a) Aluminium Bus bar RYBN 200 Amps -01 Set. (b) MCCB 160 Amps, 4 Pole, 415 Volt 35 KA (Outgoing) : 01 No (Make : Legrand /L & T/Schneider/ABB/Siemens). (c) MCCB 25A - 100 A, 4 Pole, 415 Volt 35 KA (Outgoing) : 04 Nos (Make : Legrand /L & T/Schneider/ABB/Siemens). (d) Indicator LED lamp RYB : 01 Set (e) Digital Multi function meters with CTs - 01 Set
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal ground level and connected to galvanized earth Lead strip 32x6mm(up to 7.5m fro electrode to test point) by means of bolts, nuts, check nuts and washers of galvanized iron steel protected by GI pipe 50mm bore light grade and watering pipe 20mm bore GI pipe medium grade all as shown in Electrical Plate No.3 connected to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC M20 nominal mix using 20mm graded aggregates, with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with watering pipe, wire mesh, 50mm dia light grade GI protection pipe for earth lead etc., complete.
Supply and fix AC single phase static Tamper proof energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW with special features like TOD, temper logging, optical communication port display in absence of power with box including connecting/ testing on load/scaling complete all as specified and as directed.
Supply and fix AC Three phase static Tamper proof energy meter of accuracy class 1.0, 3 x 240 V, 50 Hz with Backlit LCD display of rating 10 - 60 A, measures and displays KWH, V, Current I, KW, pf last month history of KWH, MD in KW with special features like TOD, temper logging, optical communication port display in absence of power with box including connecting/testing on load/scaling complete all as specified and as directed.
Supply, installing, connecting, testing and commissioning of 3 phase, 4 wire, 50 Hz, 433 volts, feeder pillar meter box indoor type front open, dust and vermin proof made out of CRCA sheet 2mm thick compartmentalised suitable to accommodate 09 Nos energy meters including toughned glass for meter reading with locking arrangements, welded on angle iron frame 40 x 40 x 6mm duly grouted in floor/wall including necessary PCC 1:3:6 type C2 using 40mm graded stone aggregate platform with required mounting channel feeder pillar box fabricated out of 2 mm thick CRCA steel sheet duly pretreated and powder coated, factory fabricated panel, including cable glands of suitable sizes complete all as specified and directed by Engineer-in-Charge. Note : Electronic energy meter shall be measured and paid seperately.
Material and labour Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable(FRLS) 1100 volts grade multi standard copper conductor drawn through and including non-metallic PVC rigid conduit including all accessories as bend,tee,junction boxes elbows etc, fixed in walls/roof including one run of 6 sqmm earth continuity PVC insulated copper wire(FRLS) complete all as specified and as directed. Note : 3 runs of 6 Sqmm cable, one run of PVC conduit shall be measured as one length.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal ground level and connected to galvanized earth Lead strip 25x4mm(up to 7.5m fro electrode to test point) by means of bolts, nuts, check nuts and washers of galvanized iron steel protected by GI pipe 40mm bore light grade and watering pipe 20mm bore GI pipe medium grade all as shown in Electrical Plate No.3 connected to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC M20 nominal mix using 20mm graded aggregates, with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
Material and Labour for point wiring complete using 2.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, ISI marked, drawn in to stove enamel steel concealed conduit including all accessories as bend, tee, junction boxes elbows etc etc with pressed steel terminal sunken boxes of size 1.2mm covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable(FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 2.5 Sqmm Cross sectional area and all other metal parts with earth dolly for one light/fan point controlled by one way switch 16 Amps including making good disturbed surfaced of wall and treating the surface to match with existing finish complete all as specified and as directed.
Supply and fix switch flame proof rotary type with termination box in LM6,16A, single pole 250 volt complete all as specified and as directed. Make: RI/OA/1010-2A of Sudhir/Crompton.
Supply and fix tube light fitting flame proof type FLP-WP of T5 1 x 28 watt including all necessary electrical connection complete all as specified and as directed. Make: FF/OA/1271 1X28W E+ ASIAN of Sudhir or equivalent in Philips/Crompton
Supply and fix flame proof type ceiling fan 1200mm sweep, 230 volt withdown rod, canopy etc, single phase 230 volt connecting complete all as specified and as directed. Make: CF/193 48" of Sudhir or equivalent in Philips/Crompton
Supply and fix fan regulator flame 230 volt complete all as specified and as directed. Make: RI/OA/1010 of Sudhir or equivalent in Philips/Crompton
Supply and fixing distribution board made out of sheet metal enclosure(CRCA sheet), dust and vermin proof, powder coated, factory made, IP 43 protection, double door type SPN 4 way with 200 Amps, 240 Volt rated copper bus bar neutral and earth connected bars for use of MCB 240V fixed properly at directed place by using suitable required fixing arrangement complete all as specified and as directed. Note: MCB shall be mesured and paid separately.
Supply and fix MCB SP, 24Volts, 6 to 32 Amps, breaking capacity of 10 KA, 'C' Curve complete all specified and as directed.
Supply and fix MCB SPN, 240Volts, 32 Amps, breaking capacity of 10 KA, 'C' Curve complete all specified and as directed.
Material and labour Sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable(FRLS) 1100 volts grade multi standard copper conductor drawn through and including stove enamel steel concealed conduit including all accessories as bend,tee,junction boxes elbows etc, fixed in walls/roof including one run of 2.5 sqmm earth continuity PVC insulated copper wire(FRLS) including making good disturbed surfaced of wall and treating the surface to match with existing finish complete all as specified and as directed. Note : 3 runs of 2.5 Sqmm cable, one run of stove enamel steel conduit shall be measured as one length.
Supply, install and commissioning 2 TR capacity split type air conditioner, inverter type, 5 Star / ISEER -5.33 or as per latest BER norms, hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter, with copper tube condencing unit including provision of suitable bracket fixing arrangement, copper pipe of required length and insulation complete all as specified and as directed. Make: Daikin/Hitachi/LG/O General
Supply, install and commissioning 1.5 TR capacity split type air conditioner, inverter type, 5 Star / ISEER -5.33 or as per latest BER norms, hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter, with copper tube condencing unit including provision of suitable bracket fixing arrangement, copper pipe of required length and insulation complete all as specified and as directed. Make: Daikin/Hitachi/LG/O General
Supply, install and commissioning 1.0 TR capacity split type air conditioner, inverter type, 5 Star / ISEER -5.33 or as per latest BER norms, hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter, with copper tube condencing unit including provision of suitable bracket fixing arrangement, copper pipe of required length and insulation complete all as specified and as directed. Make: Daikin/Hitachi/LG/O General
Supply and Fix 2 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled indoor type designed for input 170V to 270V with output voltage stablized at 230V with accuracy of ± 2.5% and with time delay all specified and directed. Make: V Guard/Crompton Greaves/Voltas
Sreema Enterprises
ANAND REFRIGERATION
Jack Electrolinks Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .