Loading…
Loading…
Tender Value
₹4.8 Cr
EMD Value
₹4.8 L
Closing Date
8 Jul 2026, 5:00 pmClosed
Superintending Engineer(S.G.), GIDC, Vapi
Up-Gradation of fire station for four fire tenders along with control room, conference room & dormitory for fire and disaster team at GIDC Umargam.
316966
E-TENDER NOTICE NO.02 OF 2026-27 Sr No.1
Open
Miscellaneous Works
Works
Valsad
3 documents required · 3 mandatory
₹7,080
The Executive Engineer, GIDC, Vapi
₹4.8 L
23 Jun 2026
23 Jun 2026
23 Jun 2026
8 Jul 2026
23 Jun 2026
Name of Work: Up-Gradation of fire station for four fire tenders along with control room, conference
room & dormitory for fire and disaster team at GIDC Umargam.
Sr.N Item Item Description Qty. Unit Rate Amount
1. 1. Clearing and grubbing road land 0.20 Hect. 28393.04
including uprooting rank vegetation
grass bushes, shrubs, sapling and trees
girth up to 300 mm removal of stumps
of trees cut earlier and disposal of
unserviceable materials (C) By
mechanical means in area of light jungle
2. 2. Excavation for foundation in Loose or 1381.00 Cu.Mt 117.08
soft soil up to 1.5 m. depth including
sorting out and stacking of useful
materials and disposing of the excavated
stuff within GIDC Estate as directed by
engineer in charge.
3. 3. Excavation for foundation in Loose or 693.00 Cu.Mt 129.81
soft soil 1.5 m. to 3.0 m depth including
sorting out and stacking of useful
materials and disposing of the excavated
stuff within GIDC Estate as directed by
engineer in charge.
4. 4. Excavation for foundation in Dense or 72.00 Cu.Mt 175.97
Hard soil 3.0 m. to 5.0 m depth including
sorting out and stacking of useful
materials and disposing of the excavated
stuff within GIDC Estate as directed by
engineer in charge.
5. 5. Filling available excavated earth 1841.00 Cu.Mt. 130.39
(excluding rock) in trenches. plinth,
sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating
each deposited layer by ramming and
6. 6. Filling in foundation and plinth with 842.00 Cu.Mt 289.06
murrum or selected soil in layers of
20cm. thickness including watering,
ramming and consolidating etc.
complete. (upto 10 ton)
7. 7. Applying general insecticide pest 644.00 Sq.Mtr 89.28
control treatment to floors, cupboards
etc. including labour, material etc.
complete. Using Hepta chloride 20 EC.
As per 6113 pests’ concentration weight
0.50 % is recommended one-liter
chemical emulsion dilute with 39 liters
of water will give. Total dilute
concertation will be 40 liter inclusive of
one-liter chemical emulsion application
0.5 Liter chemical / Sqm of surface is
recommended as per I.S.
8. 8. Filling in plinth with sand under floors 167.00 Cu.Mt 460.19
including watering ramming,
consolidating and dressing complete
9. 9. Providing and filling rubbles including 250.00 Cu.Mt 1473.22
hand packing and filling interstices with
quarry spalls behind abutments and
between returns as directed. (upto
10. 10. P/L PCC 1:3:6 (1-cement: 3 coarse 286.00 Cu.Mt 3172.71
sands: 6 M/c stone aggregate 20 /
40mm nominal size) in foundation
concrete / floor concrete incl. machine
mixing, ramming, consolidation &
curing etc. incl. cost of form work if
required etc. complete at all levels. (In
Foundation & plinth)
11. 11. Providing and laying controlled cement 242.00 Cu.Mt 4537.98
concrete M-250 for RCC work as per
detailed drawings including centering,
shuttering (Only Fresh Ply), machine
mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but
excluding cost of reinforcement etc.
complete at all levels for RCC FOOTING
12. 12.A. Providing and laying controlled cement 48.00 Cu.Mt 6748.24
concrete M-250 for RCC work as per
detailed drawings including centering,
shuttering (Only Fresh Ply), machine
mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but
excluding cost of reinforcement etc.
complete at all levels A) RCC COLUMN
13. 12.B. B) RCC PLINTH BEAM 87.00 Cu.Mt 5810.72
14. 12.C. C) RCC Grad Slab 127.00 Cu.Mt 7291.87
15. 12.D. D) RCC WALL 21.00 Cu.Mt 6599.45
16. 13. Providing Epoxy coated TMT Bar FE- 74090.00 Kg. 76.21
500D reinforcement for R.C.C. work
including bending, binding and placing
in position complete upto floor two level
17. 14. Brickwork using common burnt clay 127.00 Cu.Mt 4021.02
building bricks having crushing strength
not less than 35 Kg. /Sq.Cm. in
foundation and plinth in cement Mortar
1:6 (1-Cement :6-finesand)
(B)Conventional
18. 15. Half brick thick honey- comb brick work 5.00 Sq.Mtr 307.58
with common burnt clay building bricks
having crushing strength not less than
35Kg/Sq.Cm. (i) In Cement Mortar 1:4 (
1- Cement : 4 - coarse sand)
19. 16. Providing & laying 15 mm thick cement 262.00 Sq.Mtr 171.80
plaster in single coat in CM 1:3 (1-
cement : 3-sand) on rough & fair side of
RCC / brick masonry, ceiling, any other
surface for interior & exterior
plastering as per architectural design /
drawings incl. making 10 x 10 mm or as
specified grooves as per pattern given in
the architectural drawings incl. drip
moulding & finished even and smooth
with neat cement slurry incl. racking out
joints, cleaning, curing, scaffolding, etc.
complete at all floor levels
20. 17. P/L 20 mm thick sand faced plaster on 825.00 Sq.Mtr 300.66
wall up to any height consisting of
12mm thick backing coat of cement
mortar 1:3 (1-cement : 3 sand) & 8mm
thick finishing coat of cement mortar 1:1
(1-cement : 1-sand) as per architectural
design / drawings incl. making 10 x
mm or as specified grooves as per
pattern given in the architectural
drawings incl. racking out joints,
cleaning, drip mounding, curing,
scaffolding, etc. complete at all floor
levels. used wooden godka
21. 18. Filling in foundation and plinth with 3.00 Cu.Mt 600.56
brick Bats Chhara in layers of 20cm.
thickness including watering, ramming
and consolidating etc. complete.
22. 19. Carrying out plinth treatment to post 538.00 Sq.Mtr 124.28
construction / existing structure by
spraying chemical solution for TERMITE
CONTROL TREATMENT including
labour and material consistent with I.S.I.
specification. Using Chlordane and
Chiorpurfiles 20 EC. As per 6131_paret-
II Concentration weight one percent is
recommended i.e. one liter 20 EC
chemical emulsion with 19 liter give 1%
concentration inclusive of one-liter
chemical emulsion application at the
rate of 5 Liter / Sq.m of surface is
recommended as per I.S. Etc. complete
as directed by EIC.
23. 20.A. Providing and laying controlled cement 38.00 Cu.Mt 10836.57
concrete M-250 for RCC work as per
detailed drawings including centering,
shuttering (Only Fresh Ply), machine
mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but
excluding cost of reinforcement etc.
complete at double height Level. A) RCC
COLUMN AT DOUBLE HEIGHT
24. 20.B. B) RCC BEAM AT DOUBLE HEIGHT 44.00 Cu.Mt 10980.40
25. 20.C. C) RCC SLAB AT DOUBLE HEIGHT 49.00 Cu.Mt 13661.23
26. 21.A.1 Providing and laying controlled cement 41.00 Cu.Mt 6748.24
concrete M-250 for RCC work as per
detailed drawings including centering,
shuttering (Only Fresh Ply), machine
mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but
excluding cost of reinforcement etc.
I) RCC COLUMN AT GF & FF LEVEL
27. 21.A.2 (A) RCC COLUMN 48.00 Cu.Mt 6788.34
II) RCC COLUMN AT Terrace LEVEL
28. 21.B.1 (B) RCC BEAM 57.00 Cu.Mt 6178.57
I) RCC BEAM AT GF & FF LEVEL
29. 21.B.2 (B) RCC BEAM 52.00 Cu.Mt 6218.67
II) RCC BEAM AT Terrace LEVEL
30. 21.C.1 (C) RCC SLAB 37.00 Cu.Mt 7291.87
I) RCC SLAB AT GF & FF LEVEL
31. 21.C.2 (C) RCC SLAB 72.00 Cu.Mt 7331.96
II) RCC SLAB AT Terrace LEVEL
32. 21.D.1 (D) RCC LINTEL & COPING 56.28 Cu.Mt 6483.82
I) RCC LINTEL & COPING AT GF & FF
33. 21.D.2 (D) RCC LINTEL & COPING 76.00 Cu.Mt 6523.91
II) RCC LINTEL & COPING AT Terrace
34. 21.E.1 (E) RCC CHHAJJA 10.00 Cu.Mt 5971.78
I) RCC CHHAJJA AT GF & FF LEVEL
35. 21.E.2 (E) RCC CHHAJJA 3.00 Cu.Mt 6011.87
II) RCC CHHAJJA AT Terrace LEVEL
36. 21.F (F) RCC STAIRCASE 18.00 Cu.Mt 7029.32
I) RCC STAIRCASE AT GF & FF LEVEL
37. 22. Trimix: Constructing the plinth slab/rcc 1977.00 Sq.Mtr 373.70
road with Ordinary cement concrete M-
250 Grade (excluding the cost of
concrete & reinforcement) mixed with
polyester fiber (12mm) @ rate of
gms. per 50 Kg. of cement with Trimix
Vacuum dewatering system with power
troweling sheet form work with M.S.
channels, shrinking of fair hardness,
non-oxidizing, Nonmetallic, heavy duty
floor hardener of FOSROC or equivalent
at the rate of 4.00 Kg. /Sq.M. with 10 mm
x 10 mm size groove cutting in concrete
as construction joint and 12 mm thick
premix expansion joint at every
Meter length. Providing and pouring
sealant of FOSROC or equivalent with
necessary equipment, labors etc.
38. 23.I Providing Epoxy coated TMT Bar FE- 67652.00 Kg. 76.21
500D reinforcement for R.C.C. work
including bending, binding and placing
in position complete upto floor two level
I) UP TO GF & FF LEVEL
39. 23.II II) ABOVE AT Terrace LEVEL 45550.00 Kg. 77.21
40. 24.I Brickwork using common burnt clay 330.00 Cu.Mt 4295.99
building bricks having crushing strength
not less than 35 Kg./Sq.Cm. cement
Mortar 1:6 (1-Cement :6-fine sand) (B)
Conventional I) UP TO GF & FF LEVEL
41. 24.II II) ABOVE AT Terrace LEVEL 65.00 Cu.Mt 4336.18
42. 25 Half brick masonry in common brunt 271.00 Sq.Mtr 716.37
clay building bricks having crushing
strength not less than 35Kg/Sq.Cm. in
Cement mortar 1:3 (1-Cement:3-
coarsesand) with 2 Nos of 6mm Mild
stee round bars after every three-course
embedded in Cement Mortar in
foundation and plinth I) UP TO GF & FF
43. 26.I Providing 10mm thick cement plaster in 642.00 Sq.Mtr 189.15
single coat on brick/concrete
walls/ceiling for interior plastering upto
two floor level and finished even and
smooth in (ii) Cement mortar 1:4 (1
cement : 4 Sand)& finishing with a
floating coat of neat cement slurry. at GF
I) UP TO GF LEVEL
44. 26.II II) FIRST FLOOR & ABOVE AT 852.00 Sq.Mtr 210.47
45. 27.I Providing 15mm thick Cement Plaster in 2771.00 Sq.Mtr 153.20
single coat on brick/concrete wall for
interior plastering upto floor two level
finished even and smooth in Cement
mortar 1:4 (1-cement :4-sand) at GF I)
UP TO GF & FF LEVEL
46. 27.II II) ABOVE AT Terrace LEVEL 102.00 Sq.Mtr 176.59
47. 28.I Providing 20 mm thick double sand 1526.00 Sq.Mtr 300.66
faced cement plaster on walls up to
height 10 meters above ground level
consisting of 12mm thick backing coat of
CM 1:3 and 8mm thick finishing coat of
CM 1:1 (1cement: 1 sand) etc.
complete.at GF I) UP TO GF & FF LEVEL
48. 28.II II) ABOVE AT Terrace LEVEL 295.00 Sq.Mtr 307.19
49. 29 Rustic Scratch wall texture created by 1821.00 Sq.Mtr 353.50
applying Rustic Scratch material with
the thickness of 2mm to 3mm over
mm outer plaster.
50. 30. Providing throating or plaster drip and 45.00 Rmt. 42.17
mounding to R.C.C. Chhajja or
51. 31. Providing Cement Vata (10cm x 10 cm) 52.00 Rmt. 23.68
size quarter round in cement mortar 1:
1 including neat cement finishing,
watering etc. Complete.
52. 32. Providing and fixing chicken mesh 30 323.00 Sq.Mtr 454.50
cm wide double folded fixed firmly to
wall with nails on vertical or horizontal
junction of RCC and brick wall before
plastering including scaffolding and all
lead & lift ete complete any floor
53. 33. Providing 20 mm thick Water Proof 105.00 Sq.Mtr 277.47
cement plaster for sunk in single coat on
brick / concrete wall for interior
plastering up to floor two level finished
even and smooth (ii) Cement mortar 1:3
(1-cement ,3- sand) and mixing
waterproofing materials of approved
brand and manufacture in cement
mortar in proportion recommended by
the manufacturer for All Floor.
54. 34. Providing and laying cement concrete 105.00 Sq.Mtr 130.48
1:5:10 (1-Cement:5-finesand:10-graded
brickbat aggregates 40mmnominal size)
and curing complete including
waterproofing material excluding cost
of form work - for toilet floor at all levels
55. 35. Providing & Laying CINDER FILLING in 12.00 Sq.Mtr 1054.44
architectural gap and sunk slab
including compacting manually with
rammer and finishing true line & level at
all floor level etc. complete as directed
56. 36. Providing and laying integrated cement 898.00 Sq.Mtr 956.16
based water proofing treatment of
required thickness over the roof, chaina
mosaic fitting and finally finishing the
surface with white cement slurry and
slopping out terrace slabs with
following specification laid to required
slope not flatter than 1:8 (the thickness
of water proofing treatment near
rainwater outlet or the lowest point of
the finished slope shall not be less then
45mm, including treating the vertical
surface of the parapet wall up to 20cms
. height above finished level of terracing
including finishing the top with joint less
water proofing plaster, curing, testing
etc. complete. (No extra shall be paid for
increase in thickness for proper slope).
(A) Applying and grouting a slurry coat
of neat cement using 2.75 kg/sqm. of
cement admixed with properly water
proofing compound conforming to IS -
2645 incl. cleaning the surface before
treatment (B) Providing and laying
mm thick cement concrete 1:5:10 (1-
Cement:5-finesand:10-graded brickbat
aggregates 40mm nominal size) and
curing complete excluding cost of form
working (C) After Two Days of proper
curing applying a second floor of cement
slurry. (D) Finishing the surface with
china mosaic pieces laid on 10mm thick
joint less cement plaster of mix 1:3(1
cement :3 coarse sand) admixed with
proprietary water proofing compound
conforming to IS :2645 and finally
finishing the surface with trowel with
neat cement slurry (E) The whole
terrace so finished shall be flooded with
water for a minimum period of two
weeks for curing for final taste. All above
operation to be done in order and as
directed and specified by the Engineer
In Charge. (The plan area shall be
measured and paid, vatta shall not be
paid separately)
57. 37. Providing & laying GVT Vitrified tiles 843.00 Sq.Mtr 1767.50
flooring over 20 mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse
sand) on new surface or fixing on
existing flooring by adhesive material
and jointed with color cement slurry
including Making 3mm spacer at joint of
tiles and fill the spacer with epoxy
jointing material ,finished with flush
pointing & cleaning the surface etc
complete selection as directed by
Architect/E.IC ( Min. Size -1.20Mt. X
Mt. or Bigger 8’ x 4’ as selected by EIC)
Make: AGL, Nitco, Kajariya or as
selected by authority.
58. 38. Providing and laying polished Kota 71.00 Sq.Mtr 965.59
stone slab flooring over 20mm
(Average) thick base of cement mortar
1:6 (1-cement : 6-coarse sand) or L.M.
1.1.5 (1-Lime putty :1.5 - coarse sand)
laid over and jointed with grey cement
slurry mixed with pigment to match the
shade of slab including rubbing and
polishing etc. complete. (A) 25mm thick
(upto 10 ton). Material should be as per
brand list as selected by authority.
59. 39. Providing and laying polished kota 30.00 Sq.Mtr 1089.67
stone slab 25mm thick in risers of steps,
skirting Dedo and pillars laid on 10mm
thick cement mortar 1:3 (1-Cement:
coarse sand) and jointed with gray
cement slury mixed with pigment to
match the shade of slab including
rubbing and polishing etc. complete.
Material should be as per brand list as
selected by authority.
60. 40. Providing and laying Vitrified tiles 88.00 Sq.Mtr 1073.13
(GVT)8 to 10 mm thick , Min. 24'' x 24''
or bigger (i.e. 2’ x 4’ or 8’ x 4’) as selected
by EIC in flooring treads of steps and
landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with flush pointing in
white cement. etc complete selection as
directed by Architect/E.I.C. Make: AGL,
Nitco, Kajariya or as selected by
61. 41. Providing & laying GVT Vitrified tiles in 256.00 Sq.Mtr 1616.00
Toilet flooring, side wall skirting, risers
of steps and DADO on 10mm thick
cement plaster 1: 3 (1 cement: 3 coarse
sands) & jointed with white cement
slurry. and jointed with color cement
slurry including Making 3mm spacer at
joint of tiles and fill the spacer with
epoxy jointing material or spacer Baar,
finished with flush pointing & cleaning
the surface etc complete selection as
directed by Architect/E.IC IC (Min. Size -
1.20Mt. X 0.60 Mt. or Bigger 8’ x 4’ as
selected by EIC) Make: AGL, Nitco,
Kajariya or as selected by authority.
62. 42. Providing & fixing 18 mm thick first 174.00 Sq.Mtr 1954.25
quality Black Polished Granite stone
approved by Client/Architect for Doors
- windows Frame, Lintel, jambs & sill in
cement mortar (1:4) including cutting,
fixing in cement paste with hairline
joint, filling the joints with white cement
/ pigments / joint filler, rounding of
edges, edge polishing & finishing as
directed by the Engineer. (fixing the
granite in one piece). Material should be
as per brand list as selected by
63. 43. P/F 18 mm avg. thick double polished 4.00 Sq.Mtr 2157.74
(both side) jet black granite slab for
urinal partition incl. making groove in
wall and fixing properly in line & level
incl. all cost of materials & labours etc.
complete at all levels.
64. 44. Providing and fixing 35 mm thick Flush 9.00 Sq.Mtr 3019.90
door shutters excl. door frame ( fitted on
granite frame) , including fixing 1 mm
thick exterior lamination over it on both
sides, peripheral 2 x 3 cm mounding
patti with colour, with Stainless Steel
hinges size - 6" x 1.25", dead lock with
key , SS handle size 30 cm Long, SS
Tower Bolt (Stoper) size 20cm long, as
per detail including one coat of primer
and two coats of oil painting as and
where required, pattern and design is to
be approved by the Architect/EIC.
65. 45. PARTLY GLAZED DOUBLE LEAF DOOR 60.00 Sq.Mtr 7373.00
(LAMINATE FINISH):- Providing &
Fixing Partly Glazed Double leaf Door,
of size as per detail drawing (for each
door.) considering block board flush
door sheet of 35 mm thickness covered
both side by 9 mm ply & finished with
mm thick laminate on both sides of
shutters and having 12 mm clear
toughen glass slits as per given pattern
& size with crystal edges in both
shutters, fixed with Burma border Patti
at joints, Finishing with all necessary S.S
hardwires like DOOR S.S Handles 5PHO
2218SS -FPHO 2218, conceal Door lock
Mortise Body 85x60M S.S , DOOR UK key
CYLI,60MM 1CK S.S 5 KEY M/HL
ROSE SS, cylinders, stoppers, tower
bolt, MS nails, SS-304 screws,
miscellaneous hardware items etc. As
per details given in drawing and as per
instructions of Architect/ consultant/
Engineer In charge.
66. 46. Providing and fixing standard extruded 8.00 Sq.Mtr 1525.00
of aluminum section of size 63.50 x
38.10 x 1.95 mm (of Jindal Section
no:4605, @ Wt 1.094Kg / Rmt with
colour anodized aluminum frame with
mm thick transparent bronze colour
tinted float glass with colour anodized
aluminum frame for ventilation with
mm thick frosted glass as details etc
complete (work for all the floors). As per
details given in drawing and as per
instructions of Architect /consultant/
Engineer In charge.
67. 47. Providing and fixing extruded 10.00 Sq.Mtr 2140.33
aluminum window having extruded
aluminum Colour Powder Coated
section frame main outer size 127mm x
horizontal Four track member size
1.205 Kg/mt, vertical member of size
1.398 Kg/mt with sliding shutters of
horizontal member size 40mm x 18mm
x 1.29mm @ wt. of 0.456Kg/mt, vertical
member of size 40mm x 18mm x
1.29mm @ wt. of 0.456Kg/mt,@ with
mm thick transparent bronze colour
tinted float glass with powder coated
aluminum fittings and fixtures and
transparent silicon sealant glass fixing
to frame as per details etc complete for
window. As per details given in drawing
and as per instructions of Architect
/consultant/ Engineer In charge.
68. 48. Providing and fixing window having 88.00 Sq.Mtr 1591.87
extruded aluminum Colour Powder
Coated section frame main outer size
Kg/mt, horizontal Three track member
size 92mm x 31.75mm x 1.30mm @
Wt.1.07 Kg/mt, vertical member of size
Kg/mt with sliding shutters of
horizontal member size 40 mmx18mm
x1.29mm @ wt.of 0.456 Kg/mt, vertical
member of size 40mm x 18mm x
mm @ wt.of 0.456Kg/mt with 5 mm
thick transparent bronze colour tinted
float glass with powder coated
aluminum fittings and fixtures and
transparent silicon sealant glass fixing
to frame as per details etc. . As per
details given in drawing and as per
instructions of Architect /consultant/
Engineer In charge.
69. 49. Providing and fixing window having 23.00 Sq.Mtr 2020.00
extruded aluminum Colour Powder
Coated section frame including
mosquito net wire mesh shutter with
powder coated aluminum fittings size as
per architectural drawings etc complete
as directed by architect /EIC.
70. 50. Providing & fixing 35 MM thick door 26.00 Sq.Mtr 2152.31
shutter excl. door frame (fitted on
granite frame) consisting of solid core
single or double leaf flush door shutter
of 30 MM thickness, lipped with 15 mm
(5MM x 3) thick x 30 mm width on stiles
& top rails and 10 mm (5 mm x2) other
stiles and bottom rails. The inner panel
laminated with 2 mm thick termite
proof, water proof & fire resistant
mounded PVC sheet with 2,4,6 raised
panel design in different plain and/ or
pre laminated colour on one side after
routing the moulded design on flush
door & 2 MM plain and/ or pre
laminated PVC sheet on other side using
rubber adhesive on flush door and
solvent cement adhesive on the PVC
lapping incl. prov. & fixing stainless steel
matt fixtures, fasteners and lock as per
the detailed drawing etc. complete at all
level (Excl. cost of granite frame). As per
architectural drawings etc complete as
directed by architect /EIC
71. 51. Providing & Fixing 100 mm 107.00 Sq.Mtr 1111.00
vertical/Horizontal blind of NL or
vyoma or equitant make of choice shade
& pattern rate shall be including
necessary NOTCH guard treatment on
both sides, the overlaps shall be uniform
& adequate. As per architectural
drawings etc complete as directed by
72. 52. Providing and fixing eco-friendly light 61.00 Sq.Mtr 1648.96
weight calcium silicate false ceiling tiles
having Tegular edge & 15 mm Thick
Densified edges on the Tile Periphery
for Extra Strength the Light weight
calcium silicate ceiling tiles shall have,
light reflection 85% non-combustible as
per B.S. 476 part IV, 100% humidity
resistance and also having thermal
conductivity0.043° w/m KC. for the best
thermal Insulation. The Light weight
calcium Silicate tile shall be of approved
texture Fine fissured/Spin tone/Cosmos
having NRC value of 0.5 & Globe having
NRC value of 0.75 NRC or equivalent of
size 595 X 595 mm to be laid on true
horizontal level suspended inter locking
metal grid of hot dipped galvanized steel
sections (galvanizing @120 grams per
sqm including both side). consisting of
main ‘T’ runner suitably spaced at joints
to get required length and size of
24X38mm made from 0.30 mm thick
(minimum) sheet, 1200mm center to
center, and cross ‘T’ of size 24X28mm
made out of 0.33mm (Minimum) sheet
spaced 1200mm along spaced between
main ‘T’ at 600mm center to center to
form a grid of 1200X600mm and
secondary cross ’T’ of length 600mm
and size 24x28mm made of 0.30 mm
thick (Minimum) sheet to be interlocked
at middle of the 1200X600mm panel to
form grid of size 600X600mm resting on
periphery walls/partitions on a
perimeter wall angle precoated steel of
size (24X24X3000mm made of 0.40mm
thick (minimum) sheet with the help of
raw plugs at 450mm center to center
with 25mm long dry wall screws @
230mm interval and laying 15mm thick
Densified edges light weight calcium
silicate ceiling tiles of approved texture
(Fine Fissured/Cosmos/Spintone) in
the grid including, cutting /making
opening for services like diffusers, grills,
light fittings, fixtures, smoke detectors
etc., wherever required. Material should
be as per brand list as selected by
authority. As per details given in
drawing and as per instructions of
Architect /consultant/ Engineer In
73. 53. Providing and fixing single layer 437.00 Sq.Mtr 606.95
waterproof Gypsum board moisture
resistant 12.5 mm thick of the make
Newgood Group Co. Ltd. or equivalent &
Newgood Group Co. Ltd. company
sections using waterproof board of size
suspended by G.I suspender of size
mm x 3 mm with intermediate channel
of size 18 mm x 40 mm x 12.5 mm at
1220 mm center to center ceiling
section of size 40 mm x 35 mm x
mm at 457 mm center to center and
perimeter channel A of size 20 mm x
mm x 30 mm x 0.50 mm at edges & drops
including paper tap sand soffit cleat,
anchor fastener, scotch bolt connecting
cleat joining compound top coat on
ceiling including making necessary
opening for light fitting, diffuser etc.
Material should be as per brand list as
selected by authority. As per details
given in drawing and as per instructions
of Architect /consultant/ Engineer In
74. 54. External wall painting (two coats pf 2646.00 Sq.Mtr 134.84
priming coat + two coats of paint) with
APEX exterior paint of Asian paints or
equivalent of required shade or
equivalent including a priming coat of
primer of approved brand and
manufacture on wall & any other
surfaces to give an even shade after
thoroughly brushing the surface &
making the surface free from mortar
droppings and other foreign matter and
sand papered smooth incl. filling the all
small holes, cracks, open joints,
undulations and similar other minor
defects of every kind with ready-made
putty of approved brand and
manufacture and rubbed smooth with
sand paper incl. nece. scaffoldings etc.
complete at all floor levels. Material
should be as per brand list as selected by
authority. As per details given in
drawing and as per instructions of
Architect /consultant/ Engineer In
75. 55. Wall painting with (two coat) plastic 4629.00 Sq.Mtr 120.94
emulsion paint of approved brand and
manufacture on undecorated wall /
Ceiling surfaces to give an even shade
including thoroughly brushing the
surface free from mortar droppings and
other foreign matter and sand papered
smooth including two coat birla putty &
two coat Primer of approved brand.
(work for all the floors). Material should
be as per brand list as selected by
authority. As per details given in
drawing and as per instructions of
Architect /consultant/ Engineer In
76. 56. Applying priming coat over new steel 127.00 Sq.Mtr 122.49
and other metal surface after and
including preparing the surface by
thoroughly cleaning, oil, grease, dirt and
other foreign matter and scoured with
brushes fine steel wood, scrapers and
sand paper with ready mixed priming
paint brushing red lead. Painting two
coats (including 1 Priming coat) on new
steel and other metal surface with
enamel paints brushing, interior to give
an even shade incl. cleaning the surface
of all dirt, dust and other foreign matter.
(work for all the floors)
77. 57. Providing and fixing S.S. (8% nickel, 33.00 Rmt 2901.11
SS304) PIPE RELLING of 0.90m height
as pattern shown in drawings at
STAIRCASE with anchoring 0.075m in
RCC or masonry including 50mm dia. SS
pipe 18 gauge @ 1.40 kg./m as hand rail,
40x40mm SS pipe 18 gauge @
kg./m as vertical support and 16mm dia.
SS pipe 18 gauge @ 0.45 kg./m as
intermediate horizontal member
including welding, grinding, fixing in
position with necessary fixtures and
fastenings (25mm bracket, base SS cap
50mm dia. hole, base SS cap 40x40mm
hole, SS pipe cap 16mm hole & 16mm
long) and polishing etc. completed.
Material should be as per brand list as
selected by authority. As per details
given in drawing and as per instructions
of Architect /consultant/ Engineer In
78. 58. Providing and fixing M.S. grills of 2586.00 Kg. 104.04
required pattern to wooden frames of
windows etc. with M.S. flats at required
spacings and frame alround, square or
round bars with round headed bolts and
nuts or by screws (A) Plain Grill
79. 59. Providing and fixing in position 38.00 Quinta 5785.56
collapsible steel shutters with vertical l
channels 20mm x 10mm x 2mm braced
with flat iron diagonals 20mm x 5mm
size with top & bottom rail soft iron
mm x 40mm x 6mm with 38mm
diameter steel pulleys complete with
bolts, nuts, locking arrangements,
stopper handles including applying a
priming coat of red lead paint. As per
details given in drawing and as per
instructions of Architect /consultant/
Engineer In charge.
80. 60. LOUVERS: Supplying and Installation of 139.00 Sq.Mtr 4545.00
Aluminum powder coated louvers etc
complete as per drawing& selection as
directed by Architect/Engineer in
81. 61. Providing a I.S.I mark 7 levers three keys 2.00 Each 213.98
brass pad lock of NAVTAL (Goderej)
make 75mm dia on completion of
82. 62. Constructing of Cooking platform 14.00 Sq.Mtr 2954.56
(sandwich type) 80cm high resting on
thick sandwiched polish kota stone in
C.M 1:3 with providing and fixing 25 mm
thick rough kota stone at bottom and
25mm thick Polish kota stone/ Granite
stone (single piece) top and polished
kota stone/ granite stone (single piece)
25mm thick on top with 15mm high
machine cut polished kota stone
/granite round moulded facia patty
including polishing etc . complete as per
drawing and specification without
stainless steel sink including necessary
cutting for sink & making hole for gas
pipe and fixing P.V.C bend of 25mm dia.
83. 63. Providing and fixing 5 mm thick PVC 20.00 Nos. 505.00
sheets as signage and display of health
signs/information of required size
having retro reflective letters/design as
per requirement, fixing the same
through approved adhesive etc.
complete work shall be carried out as
per instruction of Engineer-in-charge
(Approved make PVC foamed sheet
only) (25 x 6 cms.)
84. 64. Providing & Fixing Engraved letters, 1.00 Sq.Mtr 20200.00
figures, logo etc. on 1 mm thick S. S.
grade plate (inching plate) and fix on
any surface, wall and at any height.
Plates will be fix with Brass Pins and
nuts in proper line & level. (stops,
comas, hyphens and the like not to be
measured and not paid for separately
(ii) Indian letters-
85. 65. Providing and fixing pre-cast Rubber 318.00 Sq.Mtr 686.90
Dye / steel Dye inter locking concrete
block 60mm thick with grade of
concrete M300 pneumatic compressed /
vibrated mechanically and as per
approved design Confirming to IS
: 2006 including 35 mm Sand layer for
levelling and filling the joint with sand in
proper line and level as per guidelines of
IRC : SP 63-2018 etc. Complete. As per
details given in drawing and as per
instructions of Architect /consultant/
Engineer In charge.
86. 66. Providing and fixing pre-cast concrete 155.00 Rmt 361.84
kerb stone of gray cement based
concrete block 30cm length,30cm height
and 15cm thick of M250 grade concrete
as per approved design and including
excavation for fixing in proper line and
level, filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
87. 67. Providing and fixing in expansion joint 2.00 Sq.Mtr 2982.06
100 mm thick expansion joint board of
best quality and approved make
including cutting to required size and
shape at all levels etc. complete as
88. 68. Box cutting the road surface to proper 144.00 Cu.Mt 104.04
slope and camber for making a base for
road work including removing the
excavated stuff and depositing on the
road side slope as directed up to
89. 69. Construction of granular sub-base by 216.00 Cu.Mt 1888.52
providing & laying of compacted
thickness of 200 mm Grading 5th
Granular sub base (GSB) in layers of
(150 mm with geocell + 50 mm) of
graded granular material consisting of
machine cut black trap stone aggregate
as per grading - V given in table 400-1 of
the specification MORT&H and
compactor to the required density with
vibratory roller in all seasons as per
MORT&H , maintaining the required
slope & grade during the operation as
approved by the engineer in charge &
watering to the proper moisture content
and sprinkled with the help of truck
mounted water tank fitted with suitable
arrangement. (fully saturated having
CBR value minimum 30)
90. 70. Providing, laying, spreading and 144.00 Cu.Mt 2174.33
compacting graded stone aggregate to
wet mix macadam specification
including premixing the materials with
water at OMC in mechanical mix plant
carriage of mixed materials by tipper to
site, laying in uniform layers (Layer
should not be more than 200 mm)with
paver in sub base/base course on well-
prepared surface and camber with
Sensor paver consolidation by vibratory
road roller to achieve the desired
density by using machine crushed chips
as per required gradation mixing with
required optimum quantity of water
incl material, labour, plant and
machinery and equipment etc. complete
by plant mix method. (Using mechanical
91. 71. Construction of dry lean cement 144.00 Cu.Mt 3476.64
concrete Sub- base over a prepared sub-
grade with coarse and fine aggregate
conforming to IS: 383, the size of coarse
aggregate not exceeding 25 mm,
aggregate cement ratio not to exceed
15:1, aggregate gradation after blending
to be as per table 600-1, cement content
not to be less than 150 kg/ cum,
optimum moisture content to be
determined during trial length
construction, concrete strength not to
be less than 10 Mpa at 7 days, mixed in a
batching plant, transported to site, laid
with a paver with electronic sensor,
compacting with 8-10 tonnes vibratory
roller, finishing and curing.
92. 72. Construction of un-reinforced, dowel 287.00 Cu.Mt 8055.61
jointed, plain cement concrete
pavement over a prepared sub base with
approve grade cement @ 400 kg per
cum, coarse and fine aggregate
conforming to IS 383, maximum size of
coarse aggregate not exceeding 25 mm,
mixed in a batching and mixing plant as
per approved mix design, transported to
site, laid with a fixed form or slip form
paver, spread, compacted and finished
in a continuous operation including
provision of contraction, expansion,
construction and longitudinal joints,
joint filler, separation membrane,
sealant primer, joint sealant, debonding
strip, dowel bar, tie rod, admixtures as
approved, curing compound, finishing to
lines and grades as per drawing.
93. 73. LAMINATE FINISH TABLE: Providing & 4.00 Sq.Mtr 17170.00
fixing laminate finish table having given
size with height of 750 mm (as per
attached detail drawing) Table having
40 mm Thick .at top made by 19 mm
thick sandwich ply. Top is cantilever
then its base supports. Base supports
made by 19 mm thick sandwich ply. A
Table having drawers and a shutter in a
pedestal and a key board trey at single
end. Drawers & Keyboard trey rest on
telescopic channels. Shutters & drawers
having thickness of 25 mm which are
made by 19 mm + 6 mm ply to create
conceal grooves as handle. Drawers &
keyboard, sides, Bottom is covered with
19 mm ply & back of pedestal are made
up of 12 mm thick Marin Ply Wood.
Having 3" high Footrest of 19 mm ply.
At Front facade (covered with grooves
as per given patterns.
All internal and external surfaces
covered by 1mm thick laminate. all
complete with given nos of key board
trey, drawers on telescopic channels,
locks, stoppers, SS Screws, MS nails,
Auto hinges, Cable Manager etc as per
shown in detail drawings & as per
instructions of architect/consultant / in
charge engineer. Contractor has to
provide all necessary cut outs for
Electrical works & no extra payment
shall be made for it. Material should be
as per brand list as selected by
authority. As per details given in
drawing and as per instructions of
Architect /consultant/ Engineer In
94. 74. CORIAN TOP VINEER FINISH 8.00 Sq.Mtr 20200.00
CONFERENCE TABLE : Providing &
fixing corian top veneer finish
conference table 750 mm height , see
size as per detail drawing ,Corean Top
based on 19 mm thick Marin plywood
finished by rubbing ,buffing & pasting
(Core an top covers 300 mm bottom of
table at longitunal side & 300 mm
bottom of table at shorter side including
edges) table have base of 19 mm thick
plywood for footrest & supporting
vertical supports made by of 12mm+9
mm thick sandwiched Ply for grooving
as indicated in drawing. (as per details
given in sectional drawing) Base of the
table covered by Burma teak bidding
Patti finished with veneer. All external
& internal surfaces covered by 4mm
thick veneer, complete with PU spray
polish All complete as per shown in
detail drawings & as per instructions of
architect / in charge engineer.
Contractor has to provide all necessary
cut outs for Electrical works & no extra
payment shall be made for it. Material
should be as per brand list as selected by
authority. As per details given in
drawing and as per instructions of
Architect /consultant/ Engineer In
95. 75. DINNING TABLE: - Providing & fixing 4.00 Sq.Mtr 20200.00
DINNING TABLE, having size as per
detail drawing, granite top surface with
proper finished, polished all side
moulding, chamfering & teakwood
frame, support with 12mm ply inside
with polishing, necessary hardware etc
All complete as per shown in detail
drawings, photos or selected by
authority. & Material should be as per
brand list as selected by authority.
96. 76. Providing & fixing plywood frame of 30.00 Sq.Mtr 1668.91
150mm x 38mm thick, fitting & fixing as
per drawing 1.0 mm laminate of
approved colour & shade as approved
97. 77. Providing & fitting toughed 12 mm clear 14.00 Sq.Mtr 1086.18
float glass of modi or equlent makes as
per approved design shall be provide
from f.f. up to 2.4 mt height fixed with
wooden molding on both sides finished
with melamine polish/glass film as
approved by EIC.
98. 78. Providing & fitting toughed 12 mm clear 7.00 Sq.Mtr 2780.71
float fully glass Door of modi or equilent
makes with floor spring heavy duty,
cm long handle both side, locks and
other necessary fittings as per approved
design shall be provide from f.f. up to
mt height fixed with wooden molding on
both sides finished with melamine
polish/glass film as approved by EIC.
99. 79. FABRIC FINISH VISITOR CHAIR - 14.00 Nos. 7575.00
Providing & Supplying of Fabric finish
visitor Chairs, having single touch
adjustable seat of appropriate size,
Frame construction should be of nylon &
black in color having dimension of
1200mm Ht., 475mm width & 431 mm
Depth & Back cushion Ht. should be
mm. It should have Nylon base Arms;
Armrest is T fixed. having ht. of 260mm,
It should have minimum 5 years
warranty. Complete as per instructions
given by the Architect & Engineer In
charge & as per shown in the View.
Samples should be approved by the
Architect & Engineer In charge. Please
see the Attached Make List for Approved
Makes Make: Hoff - Model No. Eone, or
wipro, Godrej. MEDIUM BACK WITH
FABRIC FINISH VISITOR CHAIR WITH
FIBER LEG REVOLVING.
100. 80. HIGH BACK WITH COMPOSITE LATHER 2.00 Nos. 15150.00
CHAIR - Providing & Supplying of High
Back Chairs, having single touch
adjustable seat of size 525mm x 500mm,
having adjustable tilt angle & tension
with lock to find optional position, water
fall seat cushion slopes slightly
downward to help reduce stress on your
legs. Frame construction should be of
aluminum & black in color having
dimension of 1200mm Ht., 700mm
width & 750 mm Depth & Back cushion
Ht. should be 719 mm. It should have
Nylon base Arms, Armrest is 2D. it
should have provision of Gas Lift system,
WITH CROME LEG AND FANCY ARM
REST WARRANTY 1 YEAR Complete as
per instructions given by the Architect &
Engineer In charge & as per shown in the
View. Shape, design, material, colour,
etc. will be selected by
Architect/Engineer In charge. Make:
Hoff - Model No. Spon (H), or Wipro,
Godrej. WITH CROME LEG AND FANCY
ARM REST WARRANTY 1 YEAR
101 81. WOODEN DINNING CHAIR: - Providing 10.00 Nos. 7070.00
& supplying Wooden chair, having solid
teak wood chair etc All complete as per
shown in drawings, photos & as per
instructions of architect / engineer in
102 82. 2-SEATER SOFA: The Inside frame shall 4.00 Nos. 25250.00
be made of seasoned wood with proper
anti-termite treatment. The seat and
back shall be made of foam and finished
in leatherite upholstery. leatherite
colour and type shall be as per approval.
The seat and back shall be made of PU
foam of density 45 ± 2 Kg/m3 . hardness
- 20 ±2 on Hampden machine at 25%
compression with wood inserts for
ensuring long life and optimum comfort
to the users. The complete seat and back
cushion shall be upholstered with satin
repellant “Velveteen fabric”. Under
structure proved S.S. frames made from
50mm x 25mm S.S. with stander Buffing.
All complete as per shown in drawings,
photos & as per instructions of architect
/ engineer in charge.
103 83. LAMINATE FINISH SIDE CREDENZA UP 5.00 Sq.Mtr 16160.00
to 0.75MT HT: Providing & fixing
Laminate Finish Low ht back credenza
having Ht of 750mm. having 18 mm
quartz stone top with ply. base, based on
vertical supports made by 19mm Thick.
comm Ply Wood with all shutters &
horizontal single self (made by 19 mm
thick Marin ply) as per given in detail
drawings. Backside of low ht storage is
covered with 12 mm thick plywood.
Shutters made with 19mm ply with
wooden handles. Credenza have
suggested nos of drawers of suggested
ht and suggested self & shutters. All
exposed and internal Joints complete
with teak wood bidding patti finished
with melamine polish. All exposed and
internal surfaces covered with 1 mm
thick approved shade laminates as
instructed by Architect/ consultant/
Engineer in charge. Sizes and patterns
may be varies as suggested by architect.
All fixtures and fastening must be
approved by architect/EOI as per given
standard make. Complete with all all-
necessary mouldings, hardware like MS
nails, ss-304 screws, magnet, Stoppers, L
- hinges, 19 mm multilocks, table chain,
conceal handles etc.
104 84. Providing and fixing in position cowel 2.00 Nos. 389.74
went to pipes. 75mm dia.
105 85. Providing and fixing in position cowel 12.00 Nos. 501.87
went to pipes. 100mm dia
106 86. Providing and fixing Gun metal check or 2.00 Nos. 186.83
non-return fullway wheel valve.
107 87. Providing and fixing Gun metal check or 3.00 Nos. 420.63
non-return fullway wheel valve.
108 88. Providing and fixing Gun metal check or 5.00 Nos. 314.73
non-return fullway wheel valve.
109 89. Providing and fixing Gun metal check or 3.00 Nos. 663.43
non-return fullway wheel valve.
110 90. Providing and fixing ball cock of 1.00 Nos. 137.89
approved. quality as directed.
(B) Abonite (ii) 50mm dia.
111 91. Providing laying and jointing in true line 245.00 Rmt 72.65
and level 15mm dia. U.P.V.C. Pipe (SCH-
40) for cold water including fittings as
approved by Engineer in Charge. Pipe
shall be fixed on the wall with the help of
clamp at every two-meter C/C or shall
be concealed as directed including
necessary fittings etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost of
all materials. Material should be as per
brand list as selected by authority.
112 92. Providing laying and jointing in true line 120.00 Rmt 91.84
and level 25mm dia. U.P.V.C. Pipe (SCH-
40) for cold water including fittings as
approved by Engineer in Charge. Pipe
shall be fixed on the wall with the help of
clamp at every two-meter C/C or shall
be concealed as directed including
necessary fittings etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost of
all materials. Material should be as per
brand list as selected by authority.
113 93. Providing laying and jointing in true line 150.00 Rmt 119.15
and level 32mm dia. U.P.V.C. Pipe (SCH-
40) for cold water including fittings as
approved by Engineer in Charge. Pipe
shall be fixed on the wall with the help of
clamp at every two-meter C/C or shall
be concealed as directed including
necessary fittings etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost of
all materials. Material should be as per
brand list as selected by authority.
114 94. Providing laying and jointing in true line 100.00 Rmt 148.12
and level 40mm dia. U.P.V.C. Pipe (SCH-
40) for cold water including fittings as
approved by Engineer In Charge. Pipe
shall be fixed on the wall with the help of
clamp at every two-meter C/C or shall
be concealed as directed including
necessary fittings etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost of
all materials. Material should be as per
brand list as selected by authority.
115 95. Providing laying and jointing in true line 140.00 Rmt 195.67
and level 50mm dia. U.P.V.C. Pipe (SCH-
40) for cold water including fittings as
approved by Engineer in Charge. Pipe
shall be fixed on the wall with the help of
clamp at every two-meter C/C or shall
be concealed as directed including
necessary fittings etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost of
all materials. Material should be as per
brand list as selected by authority.
116 96. Providing, laying and jointing in true 275.00 Rmt 836.73
line and level 110 diameter U.P.V.C
(Type B) conforming to IS 13592-1992
with one end plain and other end
socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of
approved make for drainage system
pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall
be fixed on wall using of PVC clamp of
the size 110 mm diameter x 149 mm
length x 145 mm heigh at every
mm center to center or shall be
concealed in walls as directed including
necessary fittings such as bends, shoes
etc. including testing of pipes and joints
and jointed with adhesive solvent
cement including cost of all materials.
Material should be as per brand list as
selected by authority.
117 97. Providing and fixing PVC SWR Nahni 3.00 Nos. 571.08
trap IS 14735 for drain - 100 mm
diameter with jali of the following
nominal diameter of self-cleansing
design with C.I scread down or hinged
grating including the cost of cutting and
making good the walls.
118 98. Providing erecting and fixing double 5000.00 Liter 3.95
coated ISI water tank of required
capacity each with all necessary fittings
and connection etc. complete on terrace.
Material should be as per brand list as
selected by authority.
119 99. Providing and fixing concealed center 35.00 Rmt 166.86
point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water
of following dia. nominal bore tube
fittings and clamps including making
good the wall, ceiling and floor etc.
complete. [A] 15 mm. Material should be
as per brand list as selected by
120 100. Providing and fixing S.W. gully trap with 5.00 Nos. 1292.19
C.I. grating brick masonry chamber and
water tight C.I. cover with
frame of 300mm x 300mm size (inside)
with standard weight. (i) Square mouth
traps. (A) 100mm x 100mm size P type.
121 101. Providing laying (to level or slopes) and 210.00 Rmt 248.67
jointing reinforced concrete Light duty
non-pressure pipes I.S. class NP2 of the
following internal diameter with collars
and butt ends prepared for collar joints
including testing of joints complete.
122 102. Providing laying (to level or slopes) and 10.00 Rmt 348.04
jointing reinforced concrete Light duty
non-pressure pipes I.S. class NP2 of the
following internal diameter with collars
and butt ends prepared for collar joints
including testing of joints
123 103. Constructing Manhole with R.C.C. top 2.00 Nos. 19330.46
slab in 1:2:4 mix (1-cement :2-coarse
sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6
mix (1-cement : 3- coarse sand :6-Brick
bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-
Cement : 3-coarse sand) finished with a
floating coat of neat cement and making
channels in cement concrete 1:2:4 mix
(1-Cement :2-Coarse sand :4-stone
aggregate 20mm nominal size) finished
smooth complete including curing and
festing (i) Inside size 900mm x 1200mm
and 1.5M. deep including C.I. cover with
frame size 560mm diameter total
weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and
Wt. of frame 64 Kg.)(A) With 230mm
thick walls of brick masonry using brick
having crushing strength not less than
35Kg. / Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2) B type depth
1.50 Meter for 150mm diameter sewer.
124 104. (II) Extra rate for constructing B.B. 1.00 Nos. 397.19
masonry for every additional depth of
0.1M. GR Part thereof over item
No.24.27 (I) for depth from 1.50M. to
125 105. Providing and fixing cast iron steps of 35.00 Nos. 203.76
size 500mm x 150mm x 22.5mm and
painting with two coats of Anti-
corrosive paint etc. complete.
126 106. Constructing brick masonry chamber 5.00 Nos. 2932.93
for underground C.I. Inspection
chamber and bends with bricks having
crushing strength not less than
35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm
internal dimensions total weight of
cover with frame to be not less than
38Kg. (Wt. of cover 23 Kg.) and Wt. of
frame 15Kg. ) (R.C.C. top slab with 1:2:4
mix (1-cement :2- coarse sand :4-graded
stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished
smooth with a floating coat of neat
cement on walls and bed concrete etc.
complete. (i) Inside dimensions
455mmx 610mm and 450mm deep for
single pipe line.
127 107. Extra over items 24.44 for every 2.00 Nos. 242.39
additional depth of 0.1M. of part thereof
beyond 450mm depth for Brick
masonry chamber. (i) for 455mm x
128 108. Constructing brick masonry chamber 9.00 Nos. 3660.76
for underground C.I. Inspection
chamber and bends with bricks having
crushing strength not less than
35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm
internal dimensions total weight of
cover with frame to be not less than
38Kg. (Wt. of cover 23 Kg.) and Wt. of
frame 15Kg. ) (R.C.C. top slab with 1:2:4
mix (1-cement :2- coarse sand :4-graded
stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished
smooth with a floating coat of neat
cement on walls and bed concrete etc.
complete. (ii) Inside dimensions 500mm
x 700 mm and 450mm deep for pipe line
with one or two inlets.
129 109. Extra over items 24.44 for every 6.00 Nos. 264.86
additional depth of 0.1M. of part thereof
beyond 450mm depth for Brick
masonry chamber. (ii) for 500mm x
130 110. Constructing brick masonry chamber 6.00 Nos. 7180.44
for underground C.I. Inspection
chamber and bends with bricks having
crushing strength not less than 35Kg/
Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm internal
dimensions total weight of cover with
frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg. )
(R.C.C. top slab with 1:2:4 mix (1-cement
:2- coarse sand :4-graded stone
aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished
smooth with a floating coat of neat
cement on walls and bed concrete etc.
complete. (iii) Inside dimensions
600mm x 850 mm and 450mm deep for
pipe lines with three or more inlets.
131 111. Extra over items 24.44 for every 4.00 Nos. 325.59
additional depth of 0.1M. of part thereof
beyond 450mm depth for Brick
masonry chamber. (iii) for 600mm x
132 112. Providing laying and jointing U PVC 35.00 Rmt 89.89
SCH40 for cold water 20 mm dia (3/4)"
including its accessories.
133 113. Providing laying and jointing PVC SWR 5.00 Rmt 386.83
pipes IS 13592 for Drain - 75 mm dia it's
134 114. Providing and fixing PVC SWR P- Trap IS 25.00 Nos. 357.54
14735 for Drain -110x110 it's
135 115. Providing and fixing Gun metal check or 8.00 Nos. 871.63
non-return full way wheel valve. (A)
136 116. Providing laying and jointing PVC SWR 65.00 Rmt 337.34
pipes IS 13592 for Drain - 50 mm dia it's
137 117. Providing and fixing to the inlet mouth 6.00 Nos. 520.15
of rain water pipe cast iron grating
cm diameter and weighing not less than
138 118. Providing and fixing wash down water 7.00 Nos. 8888.00
closet European type WC pan (Wall
Hung) of Jaquar or Kohler or American
standard like JAQUAR CNS-WHT-
961SPP- SIZE 365x545x360MM and P
trap distance 23.5 cms with integral P
trap including jointing the trap with soil
pipe in cement mortar 1:1 (1 cement:
find sand) etc, complete. Make: Jaquar,
Kohler or American standards only
as selected by authority.
139 119. Providing and fixing Health Faucet hand 7.00 Nos. 1919.00
shower of Jaquar or Kohler or American
standard heavy duty with SS braided
hose 1.2 MT long pipe to water closet
like JAQUAR ALD-CHR-573. Make:
Jaquar, Kohler or American
standards only as selected by
140 120. Providing and fixing Metropole Flush 7.00 Nos. 4040.00
Valve of Jaquar or Kohler or American
standard Regular 32mm Size
(Concealed Body) with Exposed Shut Off
Provision & Round Flange like FLV-CHR-
1095N. Make: Jaquar, Kohler or
American standards only as selected
141 121. Providing and fixing Toilet roll holder - 7.00 Nos. 909.00
like Jaquar -ACN -1151N etc, complete.
Make: Jaquar, Kohler or American
standards only as selected by
142 122. Providing and fixing Urinal of Jaquar or 6.00 Nos. 7878.00
Kohler or American standard approved
quality including connection with trap
and with integral longitudinal flush
pipe. (A) Squatting plate pattern white
earthenware size of urinal
385x325x635 mm like jaquar make
code no URS-WHT-13253N including
(1) Providing and fixing SS finish waste
coupling of 32 mm dia size half thread
with 80mm height like jauar -ALD -
for wash basin with rubber plug etc
completed. Make: Jaquar, Kohler or
American standards only as selected
143 123. Providing and fixing of Jaquar or Kohler 6.00 Nos. 3383.50
or American standard SS finish flush
valve of auto closing system like jaquar
PRS-073 of approved quality and
connection with waste pipe trap etc.
completed. Make: Jaquar, Kohler or
American standards only as selected
144 124. Providing and fixing of Jaquar or Kohler 18.00 Nos. 2415.92
or American standard SS finish bottle
trap with internal partition of 32mm
size with 250mm &190mm long wall
flange connection pipes and wall flange
like jaquar ALD-769 of approved quality
with necessary fitting for wash basin etc.
completed. Make: Jaquar, Kohler or
American standards only as selected
145 125. Providing and fixing of Jaquar or Kohler 12.00 Nos. 3989.50
or American standard Wash Basin
vitreous China table top wash basin size
560mm x 450 mm in white colour. Like
JAQUAR CNS-WHT-903 SIZE OF
425x340x175MM with single hole for
pillar tape with CP or MS brackets
painted white including cutting holes
and making good the same including (1)
Providing and fixing of Jaquar or Kohler
or American standard SS waste coupling
of 32 mm dia size half thread with
80mm height like jaquar -ALD - CHR-
705 for wash basin with rubber plug etc.
completed. Make: Jaquar, Kohler or
American standards only as selected
146 126. Providing and fixing on platform 1.00 Nos. 6110.50
stainless steel Sink glossy ASIS
grade x 1mm thick with overall size
610x460mm & bowl size
560x410x200mm including fixing the
sink in platform & making good the
same including the cost of PVC waste
pipe of 32mm dia. and PVC waste
coupling etc complete as directed by EIC
147 127. Providing and fixing of Jaquar or Kohler 13.00 Nos. 3030.00
or American standard SS Pillar cock with
extension body like JAQUAR FUS-CHR-
29021N etc complete as directed by EIC.
Make: Jaquar, Kohler or American
standards only as selected by
148 128. Providing and fixing of Jaquar or Kohler 7.00 Nos. 2727.00
or American standard Two-way BIB
cock with wall flange of genuine
company brand, in with model no like
FUS-CHR29041, water tap brand or
approved ISI brand quality, fixing in
pipeline and testing the same… etc.,
complete., as directed by EIC. Make:
Jaquar, Kohler or American
standards only as selected by
149 129. Providing and fixing of Jaquar or Kohler 8.00 Nos. 1515.00
or American standard SS finish Angular
Stop cock for wash basin like Jaquar
FUS-29053. Make: Jaquar, Kohler or
American standards only as selected
150 130. Providing and fixing of Jaquar or Kohler 4.00 Nos. 2121.00
or American standard SS finish bib tap
like Jaquar Florentine Bib Cock (Silver)
FUS-CHR-29037. Make: Jaquar, Kohler
or American standards only as
selected by authority.
151 131. Providing and fixing of Jaquar or Kohler 5.00 Nos. 17170.00
or American standard Overhead Shower
ø105mm Round Shape Single Flow with
Air Effect (ABS Body & Face Plate
Chrome Plated) with Rubit Cleaning
System like JAQUAR OHS-1709 &
Shower Arm Casted 160mm Long Light
Body Round Shape for Wall Mounted
Showers with Flange like JAQUAR SHA-
477 & Wall Mixer 3-in-1 System with
Provision for both Hand Shower and
Overhead Shower Complete with
115mm Long Bend Pipe, Connecting
Legs & Wall Flange (without Hand &
Overhead Shower) like JAQUAR QQP-
7281PM, Towel Rack 600mm Long
without Hangers, Stainless Steel like
JAQUAR ACN-1181FS approved ISI
brand quality, fixing in pipeline and
testing the same etc., complete., as
directed by EIC. Make: Jaquar, Kohler
or American standards only as
selected by authority.
152 132. Providing, supplying and fixing Waste 6.00 Nos. 303.00
153 133. Providing, supplying and fixing cement 590.00 Nos. 126.25
Bluster as approved by EIC.
154 134. Providing, supplying and fixing GRC 43.00 Sq.Mtr 3131.00
CIVIL WORK: TOTAL PART-A
ELECTRICAL PART
155 135. Point wiring for Light / Bell with 2-1.5
sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length , in
below type of pipe erected with 6A
Modular type switch / bell push &
accessories and earth continuity of
following type, erected on PVC /
Metallic/Wooden box, single mounting 125 Pt. 449.45
base frame covered with
textured/metallic/white front plate
modules erected on / in wall / ceiling as
per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as
(f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete cat III
156 136. Point wiring for Tissino / Modular
secondary light point with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (green) both
are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires,
in below type of pipe to be erected
complete with earth continuity and
necessary connection with primary 92 Pt. 151.50
light with accessories erected on
Metal / PVC / wooden box covered
with 3 mm thick PC(Polycarbonate)
/ Acrylic sheet for open / concealed
wiring. with necessary Lamp holder /
ceiling rose / H.D.Connector as directed.
Note:- Maximum up to 6 mtrs length,
excess will be considered as Mains for
Secondary Point.
(f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete cat III
157 137. Point wiring for FAN with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (Green) both
are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multi strand copper wires
up to 10 mtr length, in below type of
pipe erected with 6A Modular type
switch and hum free EME step type
electronic fan regulator mounted and
accessories with earth continuity of
following type erected on PVC / 31 Pt. 629.23
Metallic/Wooden box, single mounting
base frame covered with
textured/metallic/white front plate
modules erected on / in wall / ceiling
as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete cat III
158 138. Point wiring for Individual Plug with &
earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up
to 10 mtr length, in below type of pipe
erected complete with Modular type
switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with
appropriate front plate modules erected 7 Pt. 697.91
on / in wall / ceiling as per pipe erected
with following type of accessories [II]
For 16A Plug and 16 amp switch with
2-2.5 sq.mm Cu. Wire from mcb db
(f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete cat III
159 139. Point wiring for Individual Plug with &
1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up
to 10 mtr length, in below type of
pipe erected complete with Modular 36 Pt. 473.69
type switch & 5 pin Plug erected on
PVC / Metallic/Wooden box covered
with appropriate front plate
modules erected on / in wall / ceiling as
per pipe erected with following type of
accessories. [I] For 6A Plug and 6 a
switch with 2-1.5 sq.mm Cu. Wire from
nearby switchboard/mcb db board (f)
with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
160 140. Point wiring for on board Looped Plug
with 6A Modular type switch & 5 pin
socket erected on PVC /
Metallic/Wooden box, single mounting 48 Pt. 241.39
base frame covered with textured /
metallic/white front plate modules
erected on / in wall / ceiling with
following type accessories Cat. III
161 141. Providing & erecting Switch board for
Computer or electric apparatus
consisting of following modular type
accessories mounted with PVC /
Metallic concealed/open box with
single mounting base frame covered 3 Ea 1081.71
with textured/metallic /white front
plate, modules erected with necessary
connections as directed1 no. 6A/16A
universal plug-switch combined. 3 nos.
6A Switch3 nos. 6A 5 pin Plug For
Modular Type Accessories Cat. III
162 142. Providing following type of
Modular Type Accessories mounted
with PVC / metallic/Wooden box, single
mounting base frame covered with
textured / metallic/white front plate, 3 Ea 153.52
modules erected with necessary
connections as per site situation
directed by Engineer In charge.
(8) Computer RJ-45 socket Cat.III
163 143. Supplying & erecting approved make
LAN cable of following size in existing 250 Mtr. 45.45
pipe as per direction [C] CAT -
164 144. Providing following type of
Modular Type Accessories mounted
with PVC / metallic/Wooden box, single
mounting base frame covered with
textured / metallic/white front plate, 4 Ea 153.52
modules erected with necessary
connections as per site situation
directed by Engineer In charge.
(3) Two Pin/RJ-11 Telephone Socket
[A] For One Gang Cat.III
165 145. Supplying & erecting approved make
Telephone Cable electrolytic copper
conductor PE insulation twisted in two
pairs, & wrapped with FRLS PVC tape 300 Mtr. 19.19
& sheathed with FRLS PVC or HFFR
outer Jacket suitable for telephone
wiring & confirming to C-DOT erected in
existing pipe. of following size of
conductors & nos.of pairs. With
necessary connections.
[A] Conductor Size 0.5 mm
166 146. Providing & erecting main Distribution
(MDF) indoor type, back mounted
frame as per DoT standard approved 1 Ea. 949.40
with krone strips
(a) Suitable for 10 pair
167 147. Providing following type of
Modular Type Accessories mounted
with PVC / metallic/Wooden box, single
mounting base frame covered with
textured / metallic/white front plate, 1 Ea 153.52
modules erected with necessary
connections as per site situation
directed by Engineer In charge.
(4) TV Co-axial Socket outlet Cat.III
168 148. Providing & Erecting approved make
following size of TV Co-axial flexible
cable comprising inner conductor of
solid bare copper insulated with Foam
PE & Secondary conductor made of 150 Mtr. 37.37
poly - Aluminum film bonded Al.
Braids @ suitable coverage overall
sheathed with black PVC
169 149. providing and erecting Mains with
ISI marked, 1.5KV grade electrolyte
multi stranded, annealed copper
conductor with heat resistant PVC
insulated conforms to IS 694, IEC -
227 erected in existing pipe of 10 Mtr. 87.87
following size (Specifically for control
panel, relays, power switchgears, motor
starters & control wiring) with
required size of copper lugs, nuts and
bolts if required.
(f) One wire 10.00 sq. mm
170 150. providing and erecting Mains with
ISI marked, 1.5KV grade electrolyte
multi stranded, annealed copper
conductor with heat resistant PVC
insulated conforms to IS 694, IEC -
227 erected in existing pipe of 10 Mtr. 135.34
following size (Specifically for control
panel, relays, power switchgears, motor
starters & control wiring) with
required size of copper lugs, nuts and
bolts if required.
(g) One wire 16.00 sq. mm
171 151. providing and erecting Mains with
ISI marked, 1.5KV grade electrolyte
multi stranded, annealed copper
conductor with heat resistant PVC
insulated conforms to IS 694, IEC -
227 erected in existing pipe of 10 Mtr. 225.23
following size (Specifically for control
panel, relays, power switchgears, motor
starters & control wiring) with
required size of copper lugs, nuts and
bolts if required.(h) One wire 25.00 sq.
172 152. providing and erecting Mains with
ISI marked, 1.5KV grade electrolyte
multi stranded, annealed copper
conductor with heat resistant PVC
insulated conforms to IS 694, IEC -
227 erected in existing pipe of 10 Mtr. 286.84
following size (Specifically for control
panel, relays, power switchgears, motor
starters & control wiring) with
required size of copper lugs, nuts and
bolts if required.
(i) One wire 35.00 sq. mm
173 153. Providing and erecting Mains with
KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in
following type of pipe to be erected
concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS 610 Mtr. 59.59
PVC insulated stranded wire of green
colour for earth continuity of
following size.
(A) With medium class Rigid PVC
pipe and accessories
(a) 2 wire 1.5 sq. mm
174 154. Providing and erecting Mains with
KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in
following type of pipe to be erected
concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS Mtr. 78.78
PVC insulated stranded wire of green
colour for earth continuity of following
size. (A) With medium class Rigid
PVC pipe and accessories (b) 2 wire
175 155. providing and erecting Mains with
KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in
following type of pipe to be erected in / 430 Mtr. 405.01
on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded
wire of green colour for earth continuity
of following size
(A) with medium class Rigid PVC pipe
and accessories
(i) 4 wire 10 sq. mm
(use earth wire of 4 sq.mm)
176 156. Providing and erecting ISI mark
medium class RIGID PVC PIPES of
following size complete to be erected
on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes 350 Mtr. 32.32
fixed with adhesive solution & Clamps
with following dia of pipes, in
approved manner as directed
177 157. Providing & erecting PVC Corrugated
Flexible Conduit with required nos.
of coupling, PVC bushes, Check-nuts 50 Mtr. 20.20
etc. complete of following
sizes. (2) 25 mm
178 158. Providing and erecting Sheet Steel
powder coated MCB distribution board -
flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs 1 Ea 2913.85
should be used of same company of
MCB to be used) suitable for
(B) three phase incoming and single
phase horizontal type outgoing Per
phase isolation type (PPI)
(b) sheet steel double door
179 159. Providing and erecting Sheet Steel
powder coated MCB distribution board -
flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs 1 Ea 3412.79
should be used of same company of
MCB to be used)
suitable for (B) three phase incoming
and single phase horizontal type
outgoing Per phase isolation type (PPI)
(b) sheet steel double door
180 160. providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and 30 Ea 112.11
having breaking capacity 10 KA to be
erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
181 161. Providing & erecting 240 V MCB double
pole switch for lighting Load (B Curve)
having 10 KA breaking capacity & 3 Ea. 278.76
confirms to IS: 8828 in existing box
having following capacity
(A) 6 to 32 Amp. Cat-III
182 162. Providing & erecting 415 V MCB Four
Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & 2 Ea. 668.62
confirms to IS :8828 in existing box
having following capacity (b)40 Amp.
183 163. providing and erecting Approved make
RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and
suitable for operation on single phase
240 V,50Hz. having characteristic of 6 Ea 2235.13
quick action & tripping with all advance
feature & do not incorporate any
electronic component. for following
Max. rating erected as directed
(ii) 40Amps. DP Cat. III
184 164. Supplying & erecting approved make
Four Pole 415V change over switch
interior for panel mounting with 1 Ea 4785.38
operating mechanism A.C.23 duty
confirming to IS for
185 165. Supplying and erecting triple pole &
neutral 440V / 500V panel mounting
Copper Busbars with four equal Nos. of
electrolyte bus having current density
not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly
wrapped with colour insulating tape for 2 1961.42
phase sequence of following current r
carrying capacity, erected with
necessary bus bar supports
/insulators, main cable socket to each
bar, erected in existing cubical panel
with necessary connections.
(A) Suitable for 100 Amp. Capacity
186 166. Providing and erecting Approved make
Four pole moulded case circuit
breaker having breaking capacity ICU
of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with 5 Ea 6172.11
Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s.
with all internal connections, spreader
tinned copper & complete erected in
existing 16 G.M.S. housing.
187 167. Providing & erecting weather proof,
dust & vermin proof, floor mounted
front operated indoor type cubical
panel board necessary IP- 42 and above
protection as per approval from
engineer incharge made from 14 SWG
thick CRC M.S. sheet for outer body &
doors, 16 SWG thick CRC M.S. sheet
for internal partitions with
necessary accessories , supporting
angles/ flats channel including
cutting, bending, drilling, welding,
riveting with internal partitions &
cable alley as per requirements &
instruction of engineer-in- charge
with erection of supplied switch gears,
BUSBARS, suitable size of inter
connecting PVC copper wire / copper-
aluminum strips, rubber grommets, rib,
Bakelite control fuses/MCB for
measuring instruments, earth bus & 3 Sq.Mtr 14902.55
earth bolts, foundation flange - bolts-
base Plates, sufficient nos. of hinged
doors, handles with locking
arrangement and rubber gasket, heavy
duty end terminal connection,
danger notice board, necessary
ventilation, earthing strip complete.
The Panel shall be painted with
epoxy powder coating (The rates
exclude the cost of switchgears, bus
bars, inter connecting mains & Copper
Aluminum strips, meters, Fuses etc.
The dimension shall be measured
excluding base beams) The panel shall
be supplied with following approved
manufacturers with following size. (B)
The standard companies switch gear
shall be used and only manufacturers
at CPRI approved factory. (i) with
350mm depth board
188 168. Providing , erecting , fabricating the
M.S. structure as per requirement
on site incorporating proper size
of M.S. angles, square, round, flats,
bars, channels, sections complete
with cutting, welding, grinding & 20 Kg. 77.77
finishing duly painted with one coat
of red oxide with erection on site
as per direction of engineer in charge
with necessary grouting, cementing,
plastering & finishing complete.
189 169. Providing and erecting multifunctional 1 Ea 14123.84
meter suitable for application of Power
monitoring and showing measurement
of following Voltage, Frequency,
Apparent energy, Apparent power,
Active and reactive energy, Active and
reactive power, Average voltage Vavg,
Peak demand power PM, QM, SM,
Demand power P, Q, S, Apparent power
S, S1, S2, S3, Unbalance current, Power
factor and displacement PF (signed, four
quadrant), Calculated neutral current,
Active, reactive, apparent energy
(signed, four quadrant), Active power P,
P1, P2, P3, Voltage U21, U32, U13, V1,
V2, V3, Phase currents, Average current
Iag, Peak demand currents, Reactive
power Q, Q1, Q2, Q3, Demand current I1,
I2, I3, [Us] rated supply voltage 40...300
V AC 45...65 Hz, 40...300 V DC, Network
frequency 50 Hz, Type of network 3P,
Display type 7 segments LED, Display
colour Red, Messages display capacity
fields of 4 characters, Display digits
digit(s) - 14.2 mm in height
190 170. Supplying and erecting approved make
suitable panel indicator LED type 6 Ea 43.43
lamp, lens cover, complete erected with
necessary connections.
191 171. Providing & erecting L.T. Current
Transformer with bar primary 50/5 to
1000/5 ratio 15 VA burden erected in 1 Ea 274.72
existing CRCA box duly secured with
insulating materials connected to the
192 172. Supplying and erecting, commissioning
and testing of Diesel Generating set
confirming to IS: 4722:1968 & BS:5514
having continuous rating, 3 phase,
volts, 50 cycles A.C. supply comprising
of a totally enclosed air/water cooled
diesel engine with multi-cylinders
developing suitable BHP not less than
following capacity at 1500 RPM with
10% overload for one hour in 24 hours
with standard accessories like fly wheel, 1 Ea 410678.12
lubricating oil cooler, "A" class governor,
heavy duty fuel wheel and lubricating oil
filter, oil bath air filler, lubricating oil
pressure gauge, end exhaust manifold,
standard set of tools with adjustable
spanners, screw drivers, cylinder head
to cover, joint cylinder head to exhaust,
element lube oil filter, 12 / 24 volts
electric starting equipment complete
with standard heavy duty battery,
dynamo, cut-outs, ammeter, necessary
wiring, pressure gauge, starter etc and
heavy duty Residential type exhaust
silencer and vertical hot air duct logged
with asbestos rope, save oil trays,
exhaust piping of required length,
standard wall/floor mounted fuel with
level indicator and piping and drip
proof alternator, self-excited, self-
regulated, screen protected, with
excitation system, capable of delivering
the rated system output at 415 volts,
phase, 0.8 PF, 50 Hz, 4 wire, running at
1500 RPM, conforming to IS-4722-
with voltage regulation +/- 5% of
rated voltage from no load to full load.
Both the engine and alternator fitted on
a common fabricated steel base plate
with antivibration mounting engine
and alternator both connected to each
other by flexible flange coupling and
with floor/wall mounted control panel
box comprising of voltmeter ammeter,
selector switches, ACB / MCCB / MCB of
adequate capacity, indicator lamps duly
wired with HRC fuses. The alternator &
control panel shall be connected with
provided suitable capacity armoured
cable and complete with Acoustic
enclosure (canopy) made out of 16 SWG
CRCA Sheet, sound absorbing material
Rockwool of 64 density & 100 mm thick
conforming to IS:8183 / PU Foam of
Density - at least 40 mm. The resin
bonded rockwool covered from inside
the canopy by perforated sheet with 3/4
mm holes, sound level not more than
dB at a distance of 1 mtr, as per PVCT
norms. Erection, commissioning and
satisfactory testing as per requirement
with first filling of fuel, oil, etc. with
guarantee / Warrantee of complete
system for Two years. & with obtaining
all necessary certificate from Electrical
Inspector. The Capacity and Ratings of
DG sets are as below.
(A) Continuous Rating of 40 KVA, BHP
not less than 52 BHP
193 173. Providing & erecting approved make 1 Ea 97320.57
AMF control panel suitable for following
size of 3 phase, 415 V., 50 cycles, A.C.
diesel generating set complete of scope
as detailed below:
1) Power module: A pair of
electromechanically interlocked
contactors (for mains & generator)
Overload relay for generator contactor
Neutral contactor for mains and
generator Power socket for connections.
2) Control and metering module: Line
voltage monitor. Generator voltage
monitor Ammeter 3 items attempt start
facility. Air circuit breakers/MCB/MCCB
of suitable rating for auto/manual
operation. Auto/manual switch.
Emergency stop pushes buttons. Manual
start push button. frequency meter.
Engine hour meter. Two earthing studs.
3) Protection module: The engine
shutdown in the unlikely event of Low
lube oil pressure High cylinder head
temperature. V belt failure.
4) Indicators with alarm Load on
5) Indicators Load on mains Engine fails
to start. Emergency stop battery
The AMF Panel of following capacity
(A) AMF Control Panel for 50/62.5 KVA
194 174. Providing and erecting Approved make
Earth fault Relay suitable to mount with
inter connection suitable to following
size of moulded case circuit breaker
having CT ratio & MCCB rating as 1 Ea. 4687.41
following along with shunt trip 220V AC.
with all internal connections & complete
erected in existing M.S.housing..
195 175. Providing and erecting metallic vitrified
danger notice board as per language
suggested by engineer incharge for 3 Ea 69.69
MEDIUM VOLTAGE installation to be
erected as per IS-2551.
196 176. Providing following type of Modular
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate, modules 20 Ea 24.24
erected with necessary connections as
per site situation directed by Engineer
(7) Blank Plate Single
197 177. Providing and erecting XLPE(IS:7098)
(I)-88 ISI armoured cable multistrand 150 Mtr. 105.04
Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in
existing trench / pipe of following size of
(C) 3 core 6 Sq. mm
198 178. Providing and erecting XLPE (IS:7098)
(I)-88 ISI armoured cable multistrand /
Solid Aluminum conductor for 1.1 KV.
to be laid on wall with necessary 180 Mtr. 124.23
clamps or in existing trench / pipe of
following size of cables
(B) 4 core 6 Sq. mm
199 179. Providing and erecting XLPE (IS:7098)
(I)-88 ISI armoured cable
multistrand Aluminium conductor for
1.1 KV. to be laid on wall with 200 Mtr. 151.50
necessary clamps or in existing trench /
pipe of following size of cables
(A) 4 core 16 Sq. mm
200 180. Providing and, fixing heavy duty flange
type brass cable gland with rubber ring
for PVC insulated armored cable 8 Ea 38.38
complete without going tails, insulating
tape etc for following size of cables.
(B) 2 to 4 core 6 Sq. mm
201 181. Providing and, fixing heavy duty flange
type brass cable gland with rubber ring
for PVC insulated armored cable 4 Ea 47.47
complete without going tails, insulating
tape etc for following size of cables.
(D) 2 to 4 core 16 Sq. mm
202 182. Solder less crimping type Aluminium
lugs conforming to IS suitable for cable
of following size evenly crimped with
high pressure tool & connected to 28 Ea. 6.06
switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
203 183. Solder less crimping type Aluminium
lugs conforming to IS suitable for cable
of following size evenly crimped with
high pressure tool & connected to 16 Ea. 15.15
switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
204 184. Supplying & erecting earth pit of
minimum bore dia.150mm size
approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free 6 Ea 8636.51
hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of
25 mm having 200-250 Micron
galvanising, connection terminal dia of
12mm with constant ohmic value
surrounded by highly conductive
compound with high charge
dissipation suitable for following
type of applications with chamber
and heavy duty cover. (A)(approved
make OEM has to submit test
certificate including value of earth
resistance of installation duly
stamped and signed by agency and
officer Incharge has to ensure the
value of earthing resistane
mentioned in test Certificate) &
having back filling compound of (B)
Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing
as per IEC 62561-2017, Voltage drop:-
< 1 volt at no load & dry form, Sulphar
<2%(C) Back fill Compound :-
Earthing compound should be capable
to retain moisture for long time
Necessary test report must be
submitted by Agency.
(c) For Electrical Installation
covering Transformer Neutrals,
Lightning arrester Earthing, A.C.Plant
& Sensitive Computer System(like
Automation, SCADA) i.e
independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of
205 185. Providing and erecting required size
Copper strip for earthing of H.T. OCB / 30 Kg. 794.87
ACB/ Transformer, LT panel board,
Motors etc. using copper clamp.
206 186. Providing and erecting required size
HOT deep Galvanised iron strip for
earthing of H.T., OCB/ ACB/ 20 Kg. 77.77
Transformer LT panel board, Motors etc.
using proper clamp.
207 187. Supplying and erecting approved make
oscillating type bracket fan A.C. 23OV.
50cy/s 400/450 mm sweep wall
mounted with height adjustment and 1 Ea 2534.09
rotary tilting device complete with
guard, flexible Core plug top complete
erected with lead wires as directed.
208 188. Providing & erecting Approved make
Power Saving 50-Watt Ceiling Fan with 30 Ea 1948.29
double ball bearing ISI mark with
Condenser 230-volt A.C. 50 Hz
mm sweep complete having 3blades
with aluminium blades with, canopy &
30 cm. down rod erected with earthing.
(Make shall be approved by Engineer in
209 189. Supplying and erecting 19 / 20 mm.
nominal bore Medium Class M.S. Pipe
down rod erected duly painted for 30 Mtr. 108.07
fan complete with proper insulation
without leakage and earthing.
210 190. Supplying & erecting fan hook box of
10 mm M.S. round bar bounded to the
RCC bars up to 50mm length each side
and pierced through a 16 Gauge M.S. 30 Ea 108.07
box / Heavy Duty PVC box complete
erected concealed in Ceiling with
necessary finishing.
211 191. Providing 2. 5mm.thick laminated
acrylic sheet to cover the fan hook or 30 Ea. 18.18
212 192. Supplying & erecting approved make
low noise decorative exhaust fan having
square frame ABS body with inbuilt 8 Ea 1703.87
lowers & square frame.
200mm with 1350RPM Cat.II
213 193. Providing recess in wall or window
frame suitable for erection of Exhaust
fan complete with plastering and colour
washing to match the colour of the wall 8 Ea 189.88
or window complete with expanded
metal in order to render the fitting in
accessible and the room water-proof.
214 194. Supplying and erecting approved make
Instantaneous type water heater with
3Itr.capacity rust free container housed
in ABS plastic body insulated with glass
wool / puff insulation and 3 Kw heating 5 Ea. 4735.89
elements, adjustable thermostat 300 C
to 850 C with set to operate at 850 C (+
/-60 C) auto reset indication lamps,
thermal cut-out, safety valve fusible plug
etc. Premium Category
215 195. Supplying and erecting led lamps with
following wattage capacity of 220 to
voltage, minimum 15000 burning hours
life, 500 V in built-surge protection,
Polycarbonate diffuser, mounting 44 Ea 112.11
suitable for E14 / E27 / B22 lamp
(A) LED Lamps integral type, with PC
diffuser suitable LAMP holder
(ii) 5 to 8 watts cat - III
216 196. Supplying and erecting led lamps with 6 Ea 404.00
following wattage capacity of 220 to
voltage, minimum 15000 burning hours
life, 500 V in built-surge protection,
Polycarbonate diffuser, mounting
suitable for E14 / E27 / B22 lamp
(A) LED Lamps integral type, with PC
diffuser suitable LAMP holder
(v) 21 to 30 watts cat - III
217 197. Supplying and erecting LED indoor
fittings with LEDs of wattage
Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel
conforming to IS: 513/CRCA/
aluminium pressure die cast
powder coated and high U.V. &
corrosion resistance with diffuser
housed in aluminium casted body with
company mark/name 160V to
270V,Power Factor more than 0.95,
THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , 129 Ea 589.84
LED driver efficiency > 85 % ( fitting
required LM-79 & LM-80
Certificates)(NOTE: Below
description have shown ranges of
Wattage capacity of LED fittings.The
Engineer incharge may select any
wattage capacity between the ranges
(A) Square/ Circular shaped
Surface/Recessed Mount Downlight
with provision for spring loaded
mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV cat - III
218 198. Supplying and erecting LED indoor
fittings with LEDs of wattage
Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel
conforming to IS:
513/CRCA/aluminium pressure die
cast powder coated and high U.V. &
corrosion resistance with diffuser
housed in aluminum casted body with 30 Ea 758.51
company mark/name 160V to 270V,
Power Factor more than 0.95, THD <
%, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt, LED driver
efficiency > 85 % (fitting required
LM-79 & LM-80 Certificates)
(NOTE: Below description have
shown ranges of Wattage capacity
of LED fittings. The Engineer in charge
may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped
Surface/Recessed Mount Downlight
with provision for spring loaded
mounting clips complete. IP20
(iv) 22-24 watts, Surge-2 KV cat - III
219 199. Supplying & erecting dual channel
amplifier ,power handling capacity of
180 watt ,four micro phone inputs with
independent level control ,built in FM
tuner, with preset memories, USB drive
& SD card for MP3 playback ,100v 1 Ea. 11128.18
/telephone input with priority and VOX,
frequency response-80 Hz to 18k Hz
Philips / /distortion less than 1% @
rated power up to 50 units [[Approved
by Competent Authority i.e. not Below
the rank of Executive Engineer ]
220 200. SITC of 3LCD Lamp based projector
having wxga (1280x800) or better
resolution with minimum white
brightness of 3800 lumens and color
brightness of 3800 lumens. The
projector should have minimum
1HDMI,1VGA input. Having contrast
ratio of 15000:1 or more. the projector
should have auto vertical key stone
correction of +/- 30 degree and Manual
Horizontal of +/-30 degree. the 1 Ea. 33895.60
projector should have optical lens,
throw ratio 1.30-1.56:1. Zoom Factor of
1.2. Lens focus Manual having focal
length 16.9mm to 20.28mm. projector
should have features like AV mute slide,
quick corner and split function and
should support wireless functionality
with inbuilt wifi or wifi dongle.
[Approved by Competent Authority i.e.
not Below the rank of Executive
221 201. SITC of 100-inch Self Lock MW (7 x 5)
Insta lock Slow Retraction Screen,
Aspect Ratio-4:3 [Approved by 1 Ea. 3810.73
Competent Authority i.e. not Below the
rank of Executive Engineer]
222 202. SITC of Rack Mounting kit for the control
[Approved by Competent Authority i.e. 1 Ea. 4814.67
not Below the rank of Executive
223 203. Providing and erecting water cooler
having storage capacity 80Ltr. & cooling 2 Ea. 41342.33
capacity 40 Ltr. per hour @ an ambient
temp of 45˚ C. The outlet temp. of the
water should drop by 15˚ C within a
hour, The water cooler should be
comprising of hermetically sealed
compressor, fan motor, condensing unit,
water tank surrounded by evaporating
coil, thermostats, relay etc. complete
with necessary inlet & outlet
connection. The body of water cooler
will be made from Stainless Steel. ◦
224 204. Supplying & erecting reverse
osmosis (RO) water purification
system with M.S. powder coated
pedestal frame, prefilter housing carbon
filter suitable buster DC pump, auto low
& high pressure switches with
following size of LPH capacity &
erected as directed
[D] 100 LPH with 1 phase / 3 phase Raw
water pump of 500LPH @ 2.5kg/cm2 2 Ea. 65052.08
- (1N0 - Kirloskar /CRI/Lubi), Dual
media filter 10"x54" - (1 No), Micron
cartridge filter 20" x 2.5" ( 1No), High
pressure pump 500LPH @ 10kg/cm2
- (1No - Shimge /CRI /Lubi), RO
Membrane housing with RO membrane
of 40*40 - (1No), RO pressure tube 4"
x 1E - ( 1No), 0 - 1200LPH Rotameter -(2
Nos), with Recovery Rate 50%.
225 205. Supplying and erecting approved make
Conical Pole (Standard ) Made from HR
sheet steel. The pole should be made as
per IS. and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759
with required base plate and integral
Junction box consist of terminal plate of
min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB
Mounting, stud type terminal and 20 Ea. 6403.40
arrangement for cable terminationas
erected on suitable foundation
(included) with necessary GI nut-
bolts/J-Bolts. as per details given by
manufacturer considering site
requirement.The length of poles are as
(C) 5 Mtr. Long 65mm Top X140 mm
bottom dia, 3mm thickness.
226 206. Providing and erecting street light pole
bracket comprising main B Class MS
pipe of 4.2 cm/require outside dia. 20 Ea 561.56
complete with suitable B Class M.S.
sleeve tubing of approx.
45cms.length and suitable for
mm / 80mm. / require size pole top
having sufficient fasteners for fixing the
brackets and having spread of 1 mtr.
length with suitable rise as per site
condition & suitable welded
stiffener reducer and nipple with check
nut complete painted with one coat of
red oxide / PU base primer and two
coats of Aluminium / PU paint. paint
with following nos of arms.
[A] Single Arm bracket 1 Mtr
227 207. Supplying & erecting approved make
SMC press moulded composite FRP.
loop-in, loop- out approx. 2mm thick
box complete with Bakelite connector
strip 5way(3P+N+E), DIN rail for
mounting mob & hinged doors as
per requirement having locking 20 Ea 898.90
arrangements with mounting clamp
with nuts, bolts & washers suitable for
erection on pole with cable
clamps& earth bolt of following size of
(A) 300mm x 200mm x 100mm [deep]
228 208. Supplying and erecting LED street light
/ Flood light fittings with High power
White LEDs wattage of 3 Watt and
above assembled on single MCPCB,
efficiency more than 130 lm/w and
corrosion free High pressure die
cast aluminum housing with smooth
finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with
toughened glass with company
mark/name engraved or embossed
160 to 270 V,Power Factor more than
5700K,Uniformity ratio >0.45, 20 Ea 3345.12
Luminaire efficacy> 100 lumens/watt
. LED driver efficiency > 85 %. (fittings
79 & LM-80 certificates) (NOTE:
description have shown ranges of
Wattage capacity of LED fittings. The
Engineer in charge may select any
wattage capacity between the ranges
(A) Street Light (IP-65), Surge
protection -4KV integral and, Light
must have 440VAC line
supply with over-voltage protection.
(i) above 36 to 48 watts Cat-lll
229 209. Providing and fixing Terminal board of
size 5.0 x 127 x 152.4 mm. Bakelite
sheet with suitable brass studs with 20 Ea. 146.45
nuts, washers and clamps of size
25mm x 3mm suitable for pole painted
with one coat of red lead paint.
230 210. Supplying & erecting approved make
Digital time switch having lithium
cell 6 years operative and operate
battery backup 1 channel day clock
with 14 memory programme, suitable to
operate on 240V + 5%, 16A with,
floating contacts Minimum switching 1 Ea 3168.37
setup time 1 minimum & LCD display.
Also comprised permanent ON/OFF
switching. Programming switches &
housed in fire proof thermoplastic
enclosure & transparent cover
erected as required with necessary
connection erected as directed.
231 211. Supplying & erecting power
contactor, AC3 duty for time switch 1 Ea 1883.65
complete erected as per direction Cat III
(B) 2 pole 250V 32 Amp.
232 212. Supplying and erecting Flexible PVC
insulated multi strand multi core 1.1 kv
grade ISI marked copper wires of 60 Mtr. 44.44
following size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC
233 213. Supplying and erecting B class
Galvanized iron pipe having smooth
finished bore of the pipe on both ends
erected nuts and bolts along the pole / 80 Rmt 249.47
wall shaping the pipe as per site
requirement. Pipe dia as following.
234 214. Providing and erecting Pipe type
earthing with 40 mm dia 2.5 mtr long 'B'
grade G.I. pipe with necessary coupling
buch buried in specially prepared earth 20 Ea. 994.85
pit & G.I. earth wire of 8 SWG erected &
connected as directed (For panel)
For using salt and charcoal / coke as
required for pipe type earthing.
235 215. Providing & laying approved make
Double walled corrugated pipes
(DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting
accessories of same material at 350 Rmt 62.62
required depth in existing trench for
laying of cable. below ground / road
surface for enclosing cable
(A)50 mm outer dia
236 216. Providing & erecting 240 V MCB double
pole switch for lighting Load (B Curve)
having 10 KA breaking capacity & 20 Ea. 278.76
confirms to IS: 8828 in existing box
having following capacity
(A) 6 to 32 Amp. Cat-III
237 217. Making trench in Hard Murdrum / Tar
Road of suitable width of 90 cm or
required depth for laying any size of 150 Mtr. 62.62
cable or locating the fault all over the
run and back filling the same and
making the surface as normal ground.
238 218. Making trench in soft soil of suitable
width of 90 cm deep for laying cable or
locating the fault all over the run and 180 Mtr. 46.46
back filling the same and making the
surface as normal ground.
239 219. Supplying & erecting carbon dioxide
(CO2) fire extinguisher user of
following capacity with necessary 3 Ea 6591.26
clamps made from 50 x 6 mm M.S. Flat
with nut & bolts grouted in wall
complete. [A] For 4.5 Kg Capacity
240 220. Supplying & erecting ABC powder
type 'Ceasefire’ type Fire extinguisher 3 Ea 848.40
as per IS 13849 or 1 Kg capacity with
necessary clamp for erection on wall
241 221. Providing & erecting open well type
horizontal mono block pump set with
stainless steel body having following
specification (C) 1 H.P. single phase 1 Ea. 9613.18
open well motor pump set suitable for
185 LPM discharge @ 25 mtr. head,
suitable for 32 mm dia. Delivery pipe
with control panel. Cat III
242 222. Providing & erecting open well
horizontal mono block pump set with
cast iron body, complete for three phase
submersible motor having [C] For 3 HP
3 phase open well horizontal mono 1 Ea. 15707.52
block pump set suitable for 85 LPM to
270 LPM @ 11 mtr to 33 mtr head
suitable for 50/65 mm dia delivery pipe
243 223. Supplying & erecting approved make
Automatic liquid level controller 6A.
with sensor testing as per instruction of
Engineer in charge on site complete 2 Ea. 2355.32
with wiring connection with existing
wires, with copper conductor from
pump to upper and lower tank.
244 224. Supplying & erecting approved make
motor control cubical panel [Star delta] 1 Ea. 7250.79
made from 16G CRCA sheet duly epoxy
powder painted inside and outside
with hinged doors and locking with
suitable size of ON - OFF isolator (AC
/ 23 duty) main fuses. Digital volt and
current meter (in a single unit) with
micro controller based control unit
and current sensing single phasing
preventer electronic overload
protection, over voltage
(Programmable) protection and under
voltage (Programmable) protection,
prod less dry run protection
programming facility for setting of all
parameter like overload current, high
voltage limit, low voltage limit, dry run
limit with digital indication on seven
segment LED display for any fault like
over load, high voltage, low voltage,
dry running single crimped, electronic
star delta timer, feather touch start /
stop push buttons to be erected on
angle iron frame. Grouted on wall the
contactors will be of L& T, Siemens, BCH
make only) (A) DOL up to 5.0 H.P.
245 225. SITC of Analogue Addressable Manual
Call Point with Integral Short Circuit
Isolator, Analogue Addressable Protocol
having, Bi-colored status LED (red for
alarm, amber for (short-circuit), non-
frangible element fitted as standard 3 Ea 6060.00
(conforms to EN54), pulsing/non-
pulsing can selectable via panel,
electronically addressed, Approved by
LPCB. (Including Five-year free
maintenance with guarantee)
246 226. SITC of addressable loop powered Base
sounder with integral Beacon, includes
51 user- selectable tones (all tones
EN54-3 compatible), variable sound
output 50 ~ 98 dB(A) (±2 dB(A)) output
at 1 metre, Auto shut down feature 3 Ea 6741.75
prevents noise pollution, 'O' rated
beacon to EN-23, IP21 rated for internal
use, sounder and beacon can operate
independently, Approved by LPCB
(Including Five year free maintenance
with guarantee)
247 227. Supplying & laying of 2x1.5 sqmm fire
alarm armoured cable, 600/1000V
rated with annealed copper conductor 300 Mtr. 124.23
having XLPE insulation, steel wire
armouring & FRLS outer sheath
complete as required.
248 228. SITC of Microprocessor based Net-
workable Analogue Addressable Fire
Alarm Control Panel. The Panel shall be
compliant with EN54-2, EN54-4 and
approved by LPCB. The Fire Alarm
Control Panel shall have inbuilt 3 loops
and expandable upto 4 Loops. The Panel
must have large graphic display. The
Panel must also have the capability to
take Addressable Intelligent Wired and 1 Ea 221190.00
Wireless Devices on same loop. Each
loop shall have a capacity of
analogue Addressable devices and
Base sounders/Base Sounder Beacons.
The Panel shall have 240 V AC power
supply along with automatic Battery
Charger. Approved by LPCB (Including
Five-year free maintenance with
249 229. Supply, Installation, Testing and
Commissioning of 4MP Varifocal Lens
Dome Type Camera, H.265 4MP IR
Turret Dome N/W Camera, Manual
Varifocal 2.8-12mm, 50M, Micro SD,
DC12V/PoE, IP67/IK10, Basic IVA, 4MP
resolution (2560 × 1440), True 8 Ea. 11458.36
day/night, Digital WDR, 3D DNR, HLC &
BLC, Triple streams, Smart codec by ROI,
Built in MIC, Cyber Security, Basic
intelligent video analytics, Audio In,
NDAA Compliance, UL, CE, FCC Certified
(Including Five year free maintenance
with guarantee)
250 230. Supply, Installation, Testing and
Commissioning of 4MP Varifocal Lens
Bullet Camera, H.265 4MP IR Bullet
N/W Camera, Manual Varifocal 2.8-
12mm, 50M, Micro SD, DC12V/PoE,
IP67/IK10, Basic IVA, 4MP resolution
(2560 × 1440), True day/night, Digital 3 Ea. 11458.36
WDR, 3D DNR, HLC & BLC, Triple
streams, Smart codec by ROI, Cyber
Security, Basic intelligent video
analytics, NDAA Compliance, UL, CE, FCC
Certified (Including Five year free
maintenance with guarantee)
251 231. Supply, Installation, Testing and
Commissioning of 16 Channel Network
Video Recorder (NVR), 1, RJ-45
10/100/1000 Mbps self-adaptive 1 Ea. 21417.99
Ethernet interface, Supports H.265+/
H.265/H.264/H.264+ decoding formats,
Embedded NVR, 2 HDD Bays, up to 6TB
capacity each disk, HDMI, VGA output, 1-
ch @ 8 MP / 4- ch @ 1080p, Incoming
bandwidth 160Mbps, Outgoing
Mbps, CE FCC, BIS, Operating Temp -10
deg to 55 deg C, 2xUSB 2.0 1USB and
serial Interface (Including Five year
free maintenance with guarantee)
252 232. SITC of SCREEN SIZE 80 cm diagonal
(32” INCH), RESOLUTION HD
(1366*768), USB INPUT (2.0 SUPPORT)
2*Side(USB2.0), HDMI INPUT
3*Side(HDMI 1.4), USB DEVICE
SUPPORT USB Supported HDD, HOTEL
MODE Yes, Basic, BLUETOOTH Yes (Ver. 1 Ea. 50904.00
4), WIFI TYPE(STANDARD)
802.11a/b/g/n 2.4G 2T2R, Built-in,
WIFI BAND TYPE 2.4GHz, OS & VERSION
INFO Android 'P' - 9.0, MEMORY FLASH
8GB EMMC, RAM 1.5GB , DDR3
Mhz. (Including Five-year free
maintenance with guarantee)
253 233. SITC of 8 x 10/100/1000BASE-T PoE
ports2 x Gigabit SFP ports Advanced L2
switching and security featuresL2+
Static Routing Optional “standard
mode” or “surveillance mode” 2 Ea. 18400.18
management user interface 65W PoE
budget [Approved by Competent
Authority i.e. not Below the rank of
Executive Engineer]
254 234. Supply, Installation, Testing and
commissioning of 4 TB Surveillance 1 Ea. 15821.65
Series Hard disk supporting 24X7
operational efficiency
255 235. Providing & Erecting Network rack with
following capacity with Necessary
cooling fan, Cable manager,6A PDU, 1 Ea. 11555.08
equipment rack with necessary
mounting accessories. (A) 9 U
256 236. Providing and erecting Inverter based
approved make split air-conditioning
unit consisting of condensing unit with
variable speed fan motor, inverter type
hermetically sealed rotary compressor
with accessories etc. duly connected
separately erected evaporating unit and
blower motor with its accessories by 1 Ea. 40254.56
means of extra supplied proper
insulated copper tubing, drain PVC
pipes suitable for ( cost includes Eco
Friendly green gas charging and 15A
plug top & Remote Control & MS Stand)
with necessary core cutting.
(2) For 4/5 Star Rating of current year
(A) for 1.5 ton capacity- Premium Cat.
257 237. Providing and erecting Inverter based
approved make split air-conditioning
unit consisting of condensing unit with
variable speed fan motor, inverter type
hermetically sealed rotary compressor
with accessories etc. duly connected
separately erected evaporating unit and
blower motor with its accessories by 2 Ea. 64649.09
means of extra supplied proper
insulated copper tubing, drain PVC
pipes suitable for ( cost includes Eco
Friendly green gas charging and 15A
plug top & Remote Control & MS Stand)
with necessary core cutting.
(2) For 4/5 Star Rating of current year
(C) for 2.0-ton capacity-Premium Cat.
258 238. Supply, Installation, Testing & 50 Per 42156.39
Commissioning of following size of Grid KW
Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame
Material: Anodized Aluminum alloy
Frame with Twin Wall Profile, Front
Cover: High Transmission Low-Iron
Tempered Glass (AR Coated), High
efficiency and positive power tolerance
Pmax: 0/+5, Module Efficiency should
be approx. 18%-21%, Normal operating
temperature 45'C, Junction Box with
Waterproof IP67 & MC4 Compatible and
Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure
error free Modules, Thep. temp. co-
efficient of the PV module shall equal or
better than -0.45%/degree C. Solar PV
modules of minimum fill factor 75% to
be used. Unit Production: - 4 to 5 Unit
/kw /day (Actual) (1Year Avg) With 10-
year Product warranty and 25-year
Linear Power Warranty.,
Solar Inverter: MPPT Range: 80-1000 V,
Max efficiency: 97.5% - 98.9%, O/p
Frequency: 50/60Hz, Operating Altitude
(m) ≤4000, O/p Power Factor: ~1, O/P
THDi: <3%, Operating Temperature
Range: -25~60°C, Anti-islanding
Protection: Integrated, Input Reverse
Polarity Protection Integrated,
Insulation Resistor Detection
Integrated, Residual Current Monitoring
Unit Integrated, Output Over Current
Protection Integrated, Output Short
Circuit Protection Integrated, Output
Over Voltage Protection Integrated,
Protection Degree: IP65, User Interface
LCD & APP ,Datalogger &
Communication: GPRS / Wi-Fi, Module
Mounting Structure: Seamless Box Pipe
/ 'C' Channel of suitable size for rooftop
solar installations with good stability
against wind & weight load., Hot Dipped
Galvanized steel coils. suitable
arrangement for base plate for
foundation, solar panel mounting, the
structure should be suitable for carry
the load of solar panel, wiring, sprinkler
system etc. with necessary foundation
work/wall mount, j bolt, anchor fastener
etc. the nut bolt used for installation of
structure should be (SS 304) quality.
and Balane of System with necessary
Switchgears (Suitable size and
protection of ACDB & DCDB), inter
connecting wiring, earthing system,
lightening arrester system, all Liaoning
work with various gov. department like
state nodal agency, DISCOM & CEIG is
included in agency scope(Excluding
GEDA Application fees, Solar
connectivity Charges, Meter
connectivity Charges, Meter testing
Charges.) (D) Grid Tied Solar Power
System: 26 - 50 kW (3 - phase)
259 239. Providing & erecting Automatic solar
panel cleaning system for solar power
projects which includes necessary
plumbing work (UPVC pipes and
accessories) from source of water to
project site (up to 30 meters),Suitable
size of sub mercible/ open well motor, 50 3681.45
necessary wiring for motor and KW
sprinkler system with safety, timer
circuit for automatically on/off the
sprinkler system, necessary size and
number of nozzles/JET (minimum
Nozzle/Jet per module). (D) 21KW-
260 240. Booster Pump- Electric Motor Driven:
SITC of: Back Pull-out End Suction Type
-Single Stage, Self Priming, Centrifugal
Pump for booster Fire Pump with
Electric Motor, Mechanical Seal, Base-
frame and Couplings. 1 Set 95000.0
MOC: -Casing-CI, Impeller- Bronze,
Shaft- SS 410, Sleeve-SS410.
Capacity: 450 LPM, 3HP
Speed: 2900 Approx
Pump shall be capable of furnishing not
less than 150% of rated capacity at a
head not less than 65% of rated head
The shut off head shall not exceed 120%
UOM: -Price Per Complete set of Pump +
Motor + Accessories.
Note: -01. Minor civil work like hole/
Core Cutting etc. are in bidder’s scope.
Make: KSB/Kirloskar/Wilo
261 241. Booster Pump Control Panel-
Auto/Manual Type.
Supply, Installation and Testing of:
Electric Control Panel for Booster Pump.
all pumps can be Start Automatically (by 1 Set 23000.0
Pressure Switch) or manually. Design As
per the Detail Specifications given.
UOM: -Price Per Set.
Make: L&T, SIEMENS
262 242. Pressure Gauge with Siphon Tube and
Cock. Supply, Installation and Testing of:
Pressure Gauge with Siphon Tube and
MOC: -4” Dial- Glycerin filled- Stainless 2 No. 1150.0
Steel Body Pressure Gauge with GI
Siphon Tube andBrass Cock.
Size: -Dial: 4” (100 mm)
Range: 0 – 16 Bar (kg/cm2)
UOM:-Price Per Unit
263 243. Pressure Switch with Siphon Tube and 1 No.
Cock. Supply, Installation and Testing of:
Pressure Switch with Siphon Tube and
Size:- Range suitable for System Design
UOM:-Price Per Unit
264 244. Pipe Laying. Supply, Fabrication, 23 R.Mtr
Installation, Hydro Testing & Painting of
Under Ground Pipe. With necessary Pipe
Fitments (Flanges, Bands, Socket etc.),
MS Support/Clamps/Hangers/rapinf- 2120.0
coating etc. Hardware (Gaskets, Nut-
Bolts, Paint etc.), Consumables (Welding
Rod, etc.) and Labour Charge. Quality:
GI, C-Class (Heavy). Paint: UOM:-Price
Per Running Meter Size: 100 mm
265 245. Pipe Laying. Supply, Fabrication, 20 R.Mtr 1907.0
Installation, Hydro Testing & Painting of
Above Ground Pipe. With necessary Pipe
Fitments (Flanges, Bands, Socket etc.),
MS Support/Clamps/Hangers etc.
Hardware (Gaskets, Nut-Bolts, Paint
Consumables (Welding Rod, etc.) and
Quality: GI, C-Class (Heavy).
UOM:-Price Per Running Meter
266 246. Check Valve ( Non Return Valve) 1 No. 4680.0
Supply, Installation and Testing of:
Check Valve (Ball type or Swing type)
with necessary pipe fitments, hardware
and consumables.
MOC:-Body: Cast Iron (With Flange
Standard: ISI Marked.
UOM:-Price Per Each No.
267 247. Butterfly ValveSupply, Installation and 3 No. 2910.0
Testing of: Butterfly Valve with
necessary pipe fitments, hardware and
consumables.MOC:-Body: Cast Iron,
Disk: SS, Seat: Nitrile.UOM:-Price Per
Each No. Size: 100 mm
268 248. Air Release Valve- 25 mm 1 No. 1175.0
Supply, Installation and Testing of: Air
Release Valve Check Valve with
necessary pipe fitments, hardware and
MOC:-Body: Gunmetal / SS.
UOM:-Price Per Each No.
269 249. Fire Hydrant Landing Valve (Stainless 3 No. 3735.0
Steel (SS-304), ISI Marked):
Supply, Installation and Testing of: Fire
Hydrant Landing Valve with necessary
pipe fitments, hardware and
MOC:-Body: Stainless Steel (SS-304),
Working Parts: Stainless Steel (SS-304),
Coupling: Stainless Steel (SS-304),
Standard: -ISI Marked.
Size:-63 mm (Flange End: NB 75 mm,
UOM:-Price Per Each No.
270 250. Fire Hose Pipe (Delivery Hose)- 63 mm 3 No. 3100.0
x 15 m Supply, Installation and Testing
of: Fire Hose with Hose Couplings.
RRL (ISI Mark- Type A) Fire Hose.
Hose Couplings: ISI Marked Stainless
With SS Wire Binding.
Standard: - ISI Marked & TAC Approved
Size:-63 mm dia x 15m long Hose.
UOM:-Price Per Each Set.
271 251. Cabinet For Fire Hose (Hose Box)- Single 3 No. 1850.0
Type Supply, Installation and Testing of:
Fire Hose Cabinet (Hose Box) suitable to
accommodate 01 no. of 15 m long fire
hoses and 01 no. of nozzle. With Lock-n-
key facility. Wall Mounting Design.
MOC: 16 Gauge MS Box with Powder
Standard: - As per Guidelines.
Size:- Suitable for 01 nos. of 15 m long
UOM:-Price Per Each No.
272 252. Fire Hose Nozzle- Short Branch Pipe 3 No. 1150.0
Nozzle. Supply, Installation and Testing
of: Short Branch-pipe Nozzle.
MOC: Stainless Steel (SS-304).
Standard: ISI Marked, Heavy Quality.
Size:- 63 mm X 20 mm
UOM:-Price Per Each No.
273 253. Fire Hose Reel Set (ISI)-19 mm x 30 m - 3 No. 5485.0
Rubber Hose. Supply, Installation and
Testing of: Fire Hose Reel Set with
necessary pipe fitments, hardware and
consumables. MOC:-Drum: 16 G Powder
Coated MS, Hose: 19 mm X 30 m heavy-
duty RUBER hose. Shut-off Nozzle: SS-
304. With Control Valve: SS- 25mm Ball
Valve. Standard: ISI Marked. Heavy
Quality. Size:-19 mm dia x 30m long
Hose. UOM:-Price Per Each No.
274 254. Fire Service In-let (In-let Connection for 1 No. 3590.0
Fire Brigade)-2 Way Type.
Supply, Installation and Testing of: Fire
Service Inlet with necessary hardware
and consumables. MOC:-Body: Heavy-
duty CI. Couplings/NRV: Gunmetal.
Standard: -Made As per IS Standard-
Heavy duty quality. Size:-Couplings:
mm, 100 mm E-table Flange End. UOM:-
Price Per Each No.
275 255. Approval of Fire Hydrant & Entire Fire 1 No. 30000.0
Protection System from Local Fire
Authority and any other relevant
statutory authority at initial and various
other stages of work, including
preparation of report/drawings as per
fire authority requirement. Contractor
shall include cost of all liason work
which are not explicitly mentioned
above but are mandatory to have fire
authority approval (any statutory
charges will be paid extra).
ELECTRICAL WORK: TOTAL Rs.
CIVIL WORK: TOTAL Rs.
1. Unit Rates specified for various items to be executed as per Schedule "B" in the price bid are excluding GST
and inclusive of all labour, materials, testing charges, equipment’s, all incidental charges involved in the
items & 1% Labour Cess and as specified in the mode of measurement & payment of detailed specifications
of items, & all other taxes, royalty, octroi, transportation cost etc. all as applicable presently and as to be
enforced for future by any / all including Central/State Govt. and Statutory bodies from time to time.
2. For round the clock Maintenance clause as per tender of Building work/ Wirings/ Street Lights/ Camera
and necessary equipment etc. minimum persons are to be engaged as suggested by EIC.
3. Rates quoted should be as per minimum wages act, Government of Gujarat and must include PF, ESIC and
Bonus, failing which can result into disqualification of bidder.
I/We agree to carry out above work at __________ % above the estimated Rate put to tender
Percentage in words ( _______________________________)
I/We agree to carry out above work at __________ % below the estimated Rate put to tender
Percentage in words ( _______________________________)
Estimated Amount put to Estimated Amount put to
Tender Rs. 47866458.00 Tender Rs.
Add % Above Rs.________________ Deduct % Below Rs.______________
Net Amount Rs.____________(In figures). Net Amount Rs.____________(In figures)
I/we have read the condition mentioned in this tender and agree to abide by the same.
Signature of contractor. Executive Engineer
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 FIRE STATION DTP-VOL-1 PQ.pdf
2 FIRE STATION DTP-VOL-2 TECHNICAL BID.pdf
3 FIRE STATION DTP-VOL-3 PRICE BID.pdf
4 FIRE STATION DTP-VOL-4 Agreement.pdf
5 FIRE STATION DTP-VOL-5 Drawing.pdf
Schedule B.pdf
B1 Agreement Part 1.pdf
B1 Agreement Part 2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .